Electrospray Ionization for Mass Spectrometry of Large Biomolecules
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Electrospray ionization has recently emerged as a powerful technique for producing intact ions in vacuo from large and complex species in solution. To an extent greater than has previously been possible with the more familiar "soft" ionization methods, this technique makes the power and elegance of mass spectrometric analysis applicable to the large and fragile polar molecules that play such vital roles in biological systems. The distinguishing features of electrospray spectra for large molecules are coherent sequences of peaks whose component ions are multiply charged, the ions of each peak differing by one charge from those of adjacent neighbors in the sequence. Spectra have been obtained for biopolymers including oligonucleotides and proteins, the latter having molecular weights up to 130,000, with as yet no evidence of an upper limit.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electrospray ionization is a soft ionization technique that accomplishes the transfer of ions from solution to a gas phase [51].”
In the citing paper
“Although several ionization techniques are available, ESI is still predominately utilized for top-down proteomics as it is easy to interface with common LC systems [92].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [92]
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Self-citationDole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Self-citationOn the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
On-line mass spectrometric detection for capillary zone electrophoresis
Olivares, J. A., Nguyen, N. T., Yonker, C. R., & Smith, R. D. (1987) · Analytical Chemistry · doi:10.1021/ac00135a034 · Cited by 635
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Self-citationNegative ion production with the electrospray ion source
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a046 · Cited by 581
Self-citation
Research works printed but not linked: 11
- Abuaf, N., Rarefied Gas Dynamics 2: 1317 (1967).
- ANDERSON, J.B., ENTROPIE 18: 33 (1976).
- Karas M. paper presented at the American Society for Mass Spectrometry (ASMS) Workshop on Ion Desorption Mechanisms Sanibel Island FL January (1989).
- Karas M. paper presented at the 11th International Mass Spectrometry Conference Bordeaux France (1988).
- MANN M THESIS YALE U (1989).
- Mann, M., Proceedings of the 36th Annual Conference on Mass Spectrometry and Allied Topics: 771 (1988).
- Mann, M., Proceedings of the 36th Annual Conference on Mass Spectrometry and Allied Topics: 1207 (1988).
- SIMONS, D.S., INT J MASS SPECTROM 15: 291 (1974).
- Smith R. D. paper presented at the 5th (Montreux) Symposium on LC-MS Freidburg November (1988).
- Vestal, M. L., Mass Spectrometry in the Health and Life Sciences: 99 (1985).
- Whitehouse, C. M., Proceedings o fthe 14th Intemational Symposium on Rarefied Gas Dynamics: 857 (1985).
Cited by
Items 501–600 of 1,026
Low‐Temperature Activation of Methane: It also Works Without a Transition Metal
Schröder, D., & Roithová, J. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601273 · Cited by 159
Investigation of chemical reactions in solution using API-MS
Santos, L. S., Knaack, L., & Metzger, J. O. (2005) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2005.08.016 · Cited by 159
Cha, S., Zhang, H., Ilarslan, H., Wurtele, E. S., Brachova, L., Nikolau, B. J., & Yeung, E. S. (2008) · The Plant Journal · doi:10.1111/j.1365-313x.2008.03507.x · Cited by 158
Electrospinning carbon nanotube polymer composite nanofibers
Yeo, L. Y., & Friend, J. R. (2006) · Journal of Experimental Nanoscience · doi:10.1080/17458080600670015 · Cited by 173
“spectrometry [55].”
Schnier, P. D., Klassen, J. S., Strittmatter, E. F., & Williams, E. R. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973534h · Cited by 158
Recent advances in capillary electrophoresis of proteins, peptides and amino acids
Novotný, M. V., Cobb, K. A., & Liu, J. (1990) · Electrophoresis · doi:10.1002/elps.1150110911 · Cited by 158
Paizs, B., & Suhai, S. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2003.09.010 · Cited by 157
Molecular characterization of sulfur-containing compounds in petroleum
Han, Y., Zhang, Y., Xu, C., & Hsu, C. S. (2018) · Fuel · doi:10.1016/j.fuel.2018.02.110 · Cited by 157
Rosenberg, E. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00603-4 · Cited by 191
An Overview of Lung Cancer Genomics and Proteomics
Granville, C. A., & Dennis, P. A. (2005) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.f290 · Cited by 157
Beu, S. C., Senko, M. W., Quinn, J. P., Wampler, F. M., & McLafferty, F. W. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85017-r · Cited by 157
Electrospray cooling for microelectronics
Deng, W., & Gomez, A. (2011) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2011.02.038 · Cited by 156
“All rights reserved.”
Advances in MALDI Mass Spectrometry Imaging Single Cell and Tissues
Zhu, X., Xu, T., Chen, P., & Wu, S. (2022) · Frontiers in Chemistry · doi:10.3389/fchem.2021.782432 · Cited by 166
“Besides, Flint et al. characterized the metabolites, proteins, and metals of a novel aggregated spheroid model, termed “aggregoid,” by DESI-MSI, and they demonstrated that absolute quantification of drugs is achievable in 3D tissue models (Flint et al., 2020).”
BackgroundInfluentialConformations and folding of lysozyme ions in vacuo.
Gross, D. S., Schnier, P. D., Rodriguez‐Cruz, S. E., Fagerquist, C. K., & Williams, E. R. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.7.3143 · Cited by 156
Resolution power of two‐dimensional electrophoresis and identification of proteins from gels
Jungblut, P. R., Thiede, B., Zimny‐Arndt, U., Müller, E., Scheler, C., Wittmann‐Liebold, B., & Otto, A. (1996) · Electrophoresis · doi:10.1002/elps.1150170505 · Cited by 156
Top-down characterization of endogenous protein complexes with native proteomics
Skinner, O. S., Haverland, N. A., Fornelli, L., Melani, R. D., Do Vale, L. H. F., Seckler, H. S., Doubleday, P. F., Schachner, L. F., Srzentić, K., Kelleher, N. L., et al. (2018) · Nature Chemical Biology · doi:10.1038/nchembio.2515 · Cited by 155
Detecting and characterizing reactive metabolites by liquid chromatography/tandem mass spectrometry
Ma, S., & Subramanian, R. (2006) · Journal of Mass Spectrometry · doi:10.1002/jms.1098 · Cited by 155
Biomarkers in cancer screening, research and detection: present and future: a review
Kumar, S., Mohan, A., & Guleria, R. (2006) · Biomarkers · doi:10.1080/13547500600775011 · Cited by 155
“…level of protein; /, an increase in the expression level of protein. such as electrospray ionization (ESI) and matrix-assisted laser-desorption ionization (MALDI) has facilitated the characterization of the proteins by MS (Fenn et al. 1989, Hillenkamp et al. 1991, Karas & Hillenkamp 1998).”
BackgroundSun, Y., Wang, H., Guo, G., Pu, Y., & Yan, B. (2014) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2014.06.058 · Cited by 154
Acid–base-driven matrix-assisted mass spectrometry for targeted metabolomics
Shroff, R., Rulíšek, L., Doubský, J., & Svatoš, A. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0900914106 · Cited by 153
“O to their ‘‘soft’’ nature of ionization, MALDI-MS (1, 2) and electrospray ionization- mass spectrometry (3) (ESI-MS) have been at the forefront of bioanalytical research with farreaching applications in proteomics (4), genomics (5), biological imaging (6), and metabolomics (7).”
BackgroundNumber of Solution States of Bradykinin from Ion Mobility and Mass Spectrometry Measurements
Pierson, N. A., Chen, L., Valentine, S. J., Russell, D. H., & Clemmer, D. E. (2011) · Journal of the American Chemical Society · doi:10.1021/ja203895j · Cited by 153
Charge and Size Distributions of Electrospray Drops
de Juan, L., & de la Mora, J. F. (1997) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1996.4654 · Cited by 153
Differential mobility analysis of molecular ions and nanometer particles
de la Mora, J. F., de Juan, L., Eichler, T., & Rosell-Llompart, J. (1998) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00039-9 · Cited by 153
Top-down proteomics: challenges, innovations, and applications in basic and clinical research
Brown, K. A., Melby, J. A., Roberts, D. S., & Ge, Y. (2020) · Expert Review of Proteomics · doi:10.1080/14789450.2020.1855982 · Cited by 152
“Although several ionization techniques are available, ESI is still predominately utilized for top-down proteomics as it is easy to interface with common LC systems [92].”
MethodThe use of proteomics in meat science
Bendixen, E. (2005) · Meat Science · doi:10.1016/j.meatsci.2005.03.013 · Cited by 152
Bailey, V., Smith, A. P., Tfaily, M., Fansler, S. J., & Bond‐Lamberty, B. (2017) · Soil Biology and Biochemistry · doi:10.1016/j.soilbio.2016.11.025 · Cited by 159
Nold, M. J., Wesdemiotis, C., Yalçın, T., & Harrison, A. G. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00044-x · Cited by 152
Application of Mass Spectrometry in Proteomics
Guerrera, I. C., & Kleiner, O. (2005) · Bioscience Reports · doi:10.1007/s10540-005-2849-x · Cited by 191
“The two most commonly used techniques are matrixassisted laser desorption/ionisation (MALDI) and electrospray ionisation (ESI) [1, 2].”
MethodInfluentialProtein and antibody microarray technology
Glökler, J., & Angenendt, P. (2003) · Journal of Chromatography B · doi:10.1016/j.jchromb.2003.08.034 · Cited by 168
Sizing nanoparticles and ions with a short differential mobility analyzer
Rosell-Llompart, J., Loscertales, I. G., Bingham, D., & de la Mora, J. F. (1996) · Journal of Aerosol Science · doi:10.1016/0021-8502(96)00016-x · Cited by 152
SAG, a Novel Zinc RING Finger Protein That Protects Cells from Apoptosis Induced by Redox Agents
Duan, H., Wang, Y., Aviram, M., Swaroop, M., Loo, J. A., Bian, J., Tian, Y., Mueller, T., Bisgaier, C. L., & Sun, Y. (1999) · Molecular and Cellular Biology · doi:10.1128/mcb.19.4.3145 · Cited by 156
“Electrospray ionization mass spectrometry (ESI-MS) was performed with a double-focusing hybrid mass spectrometer (MAT 900Q; Finnigan, Bremen, Germany) with a mass-to-charge range of 10,000 at 5-kV full acceleration potential.”
MethodInfluentialUPLC–MSE application in disease biomarker discovery: The discoveries in proteomics to metabolomics
Zhao, Y., & Lin, R. (2014) · Chemico-Biological Interactions · doi:10.1016/j.cbi.2014.02.014 · Cited by 151
McDonald, J. G., Thompson, B. M., McCrum, E. C., & Russell, D. W. (2007) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(07)32006-5 · Cited by 166
Application of Fourier transform ion cyclotron resonance mass spectrometry to oligosaccharides
Park, Y., & Lebrilla, C. B. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.20010 · Cited by 151
“The reported performance of ESI (Yamashita & Fenn, 1984; Fenn et al., 1989) and MALDI (Karas & Hillenkamp, 1988; Stahl et al.”
BackgroundMethodInfluentialElectrons on dielectrics and contact electrification
Liu, C., & Bard, A. J. (2009) · Chemical Physics Letters · doi:10.1016/j.cplett.2009.08.045 · Cited by 151
Proteome Analysis by Mass Spectrometry
Ferguson, P. L., & Smith, R. D. (2003) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.32.110601.141854 · Cited by 164
Greis, K. D. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20127 · Cited by 166
Banerjee, S., Yang, Y., Jenkins, I. D., Liang, Y. F., Toutov, A. A., Liu, W., Schuman, D. P., Grubbs, R. H., Stoltz, B. M., Krenske, E. H., et al. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b13032 · Cited by 157
Native Mass Spectrometry: Recent Progress and Remaining Challenges
Karch, K. R., Snyder, D. T., Harvey, S. R., & Wysocki, V. H. (2022) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-092721-085421 · Cited by 150
“Retaining native protein structure during the transfer of analytes from solution to the gas phase is a key stage in the nMS workflow and is typically accomplished by nESI (47, 166).”
Equilibrium drop surface profiles in electric fields
Mugele, F. G., & Buehrle, J. (2007) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/19/37/375112 · Cited by 149
Song, L., Dykstra, A. B., Yao, H., & Bartmess, J. E. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.09.016 · Cited by 149
“These four ionization mechanisms make both NI-DART and NI-APPI capable of ionizing a wider range of compounds than negative ion-atmospheric pressure chemical ionization (APCI) or negative ion-electrospray ionization (ESI).”
BackgroundInfluentialElectrospray ionization mass spectrometry in the study of biomolecular non-covalent interactions
Veenstra, T. D. (1999) · Biophysical Chemistry · doi:10.1016/s0301-4622(99)00037-x · Cited by 149
Gas-Phase Separations of Electrosprayed Peptide Libraries
Barnes, C. A. S., Li, J., Marshall, W. S., & Clemmer, D. E. (1999) · Analytical Chemistry · doi:10.1021/ac9903757 · Cited by 149
Boundaries of Mass Resolution in Native Mass Spectrometry
Lössl, P., Snijder, J., & Heck, A. J. R. (2014) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-0874-3 · Cited by 136
“Efficiency of desolvation in the ESI process, i. e. adduct removal from the analyte.”
InfluentialTfaily, M., Chu, R., Toyoda, J. G., Tolić, N., Robinson, E. W., Paša‐Tolić, L., & Hess, N. J. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.03.031 · Cited by 148
Mass spectrometry–based protein identification in proteomics—a review
Noor, Z., Ahn, S. B., Baker, M. S., Ranganathan, S., & Mohamedali, A. (2019) · Briefings in Bioinformatics · doi:10.1093/bib/bbz163 · Cited by 148
Katta, V., Chowdhury, S. K., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00002a016 · Cited by 149
Peschke, M., Blades, A. T., & Kebarle, P. (2000) · Journal of the American Chemical Society · doi:10.1021/ja002021z · Cited by 148
Buffer Loading for Counteracting Metal Salt-Induced Signal Suppression in Electrospray Ionization
Iavarone, A. T., Udekwu, O. A., & Williams, E. R. (2004) · Analytical Chemistry · doi:10.1021/ac049724+ · Cited by 143
Electrospray mass spectrometry of metal carbonyl complexes †
Henderson, W., McIndoe, J. S., Nicholson, B. K., & Dyson, P. J. (1998) · Journal of the Chemical Society Dalton Transactions · doi:10.1039/a707868d · Cited by 148
Structural and functional characterization of the trifunctional antibody catumaxomab
Chelius, D., Ruf, P., Gruber, P., Plöscher, M., Liedtke, R., Gansberger, E., Heß, J., Wasiliu, M., & Lindhofer, H. (2010) · mAbs · doi:10.4161/mabs.2.3.11791 · Cited by 152
“The development of electrospray ionization in combination with new mass spectrometers allowed mass spectrometry of large molecules, including intact antibody molecules that are approximately 150 kiloDalton (kDa).(16,17) In addition, new LC techniques have been developed for the analysis of intact antibody molecules an…”
MethodWorking towards an exegesis for lipids in biology
Brown, H. A., & Murphy, R. C. (2009) · Nature Chemical Biology · doi:10.1038/nchembio0909-602 · Cited by 143
Hilton, G. R., & Benesch, J. L. P. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0823 · Cited by 140
Bioanalysis of Eukaryotic Organelles
Satori, C. P., Henderson, M. M., Krautkramer, E. A., Košťál, V., Distefano, M. M., & Arriaga, E. A. (2013) · Chemical Reviews · doi:10.1021/cr300354g · Cited by 157
Application and Perspectives of MALDI–TOF Mass Spectrometry in Clinical Microbiology Laboratories
Torres-Sangiao, E., Rodríguez, C. L., & García-Riestra, C. (2021) · Microorganisms · doi:10.3390/microorganisms9071539 · Cited by 159
“Laser desorption/ionization (LDI), matrix-assisted laser desorption ionization (MALDI) or surface-enhanced laser desorption/ionization (SELDI) as well as electrospray ionization (ESI) are currently the most widely used ionization techniques for analyzing chemical structures in biological systems [2].”
BackgroundBielawski, J., Pierce, J. S., Snider, J. M., Rembiesa, B. M., Szulc, Z. M., & Bielawska, A. E. (2010) · Advances in experimental medicine and biology · doi:10.1007/978-1-4419-6741-1_3 · Cited by 147
Indicators of milk and beef quality
Cassandro, M., GALLO, L., Carnier, P., Bittante, G., Povinelli, M., Marcomin, D., R, D. Z., & Valorz, C. (2005) · Wageningen Academic Publishers eBooks · doi:10.3920/978-90-8686-537-6 · Cited by 147
Characterization of amino acid side chain losses in electron capture dissociation
Cooper, H. J., Hudgins, R. R., Håkansson, K., & Marshall, A. G. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(01)00357-9 · Cited by 155
Zhou, M., Lantz, C., Brown, K. A., Ge, Y., Paša-Tolić, L., Loo, J. A., & Lermyte, F. (2020) · Chemical Science · doi:10.1039/d0sc04392c · Cited by 146
Desorption Electrospray Ionization-Mass Spectrometry of Proteins
Shin, Y., Drolet, B. S., Mayer, R. T., Dolence, K., & Basile, F. (2007) · Analytical Chemistry · doi:10.1021/ac062451t · Cited by 146
Increasing charge while preserving noncovalent protein complexes for ESI-MS
Lomeli, S. H., Yin, S., Ogorzalek Loo, R. R., & Loo, J. A. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.11.013 · Cited by 144
“Ahallmark of electrospray ionization (ESI) for the mass spectrometric analysis of large biomolecules is the multiple charging phenomenon described by the early work of John Fenn and others [1].”
Computational Methods for Understanding Mass Spectrometry–Based Shotgun Proteomics Data
Sinitcyn, P., Rudolph, J. D., & Cox, J. (2018) · Annual Review of Biomedical Data Science · doi:10.1146/annurev-biodatasci-080917-013516 · Cited by 143
Weiskopf, A. S., Vouros, P., & Harvey, D. J. (1998) · Analytical Chemistry · doi:10.1021/ac980289r · Cited by 146
High-order structure and dissociation of gaseous peptide aggregates that are hidden in mass spectra
Counterman, A. E., Valentine, S. J., Barnes, C. A. S., Henderson, S. C., Hoaglund‐Hyzer, C. S., & Clemmer, D. E. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00052-x · Cited by 146
Fingerprint IR Spectroscopy to Probe Amino Acid Conformations in the Gas Phase
Bakker, J. M., MacAleese, L., Meijer, G., & von Helden, G. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.203003 · Cited by 146
Pagnotti, V. S., Chubatyi, N. D., & McEwen, C. N. (2011) · Analytical Chemistry · doi:10.1021/ac200556z · Cited by 146
Proteomic definitions of basement membrane composition in health and disease
Randles, M. J., Humphries, M. J., & Lennon, R. (2017) · Matrix Biology · doi:10.1016/j.matbio.2016.08.006 · Cited by 141
Dalmázio, I., Santos, L. S., Moreira, R. P. L., Eberlin, M. N., & Augusti, R. (2005) · Environmental Science & Technology · doi:10.1021/es047985v · Cited by 145
The Na+ affinities of α-amino acids: side-chain substituent effects
Kish, M. M., Ohanessian, G., & Wesdemiotis, C. (2003) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(03)00082-4 · Cited by 145
Clostridium novyi α-Toxin-catalyzed Incorporation of GlcNAc into Rho Subfamily Proteins
Selzer, J., Hofmann, F., Rex, G., Wilm, M., Mann, M., Just, I., & Aktories, K. (1996) · Journal of Biological Chemistry · doi:10.1074/jbc.271.41.25173 · Cited by 144
Self-citationFreitas, M. A., Sklenar, A. R., & Parthun, M. R. (2004) · Journal of Cellular Biochemistry · doi:10.1002/jcb.20106 · Cited by 139
“With the introduction of soft ionization techniques such as Matrix Assisted Laser Desorption Ionization (MALDI) [Karas and Hillenkamp, 1988; Tanaka et al., 1988; Karas et al., 1989] and ElectroSpray Ionization (ESI) [Whitehouse et al., 1985; Karas and Hillenkamp, 1988; Fenn et al., 1989], the mass of intact protein io…”
BackgroundAllosteric mechanisms can be distinguished using structural mass spectrometry
Dyachenko, A., Gruber, R., Shimon, L., Horovitz, A., & Sharon, M. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1302395110 · Cited by 144
“We took advantage of the multiple charging phenomena displayed in the electrospray ionization (ESI) method (14) by using the different charge states as replicas (Fig.”
MethodLy, T., & Julian, R. R. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200900613 · Cited by 144
Mass spectrometry based tools to investigate protein–ligand interactions for drug discovery
Pacholarz, K. J., Garlish, R. A., Taylor, R. J., & Barran, P. E. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35035a · Cited by 141
Lee, S., Kim, H. S., & Beauchamp, J. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973467r · Cited by 144
The role of mass spectrometry in plant systems biology
Glinski, M., & Weckwerth, W. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20063 · Cited by 162
Determination of Noncovalent Docking by Infrared Spectroscopy of Cold Gas-Phase Complexes
Garand, É., Kamrath, M. Z., Jordan, P. A., Wolk, A. B., Leavitt, C. M., McCoy, A. B., Miller, S. J., & Johnson, M. A. (2012) · Science · doi:10.1126/science.1214948 · Cited by 143
Venturi Easy Ambient Sonic-Spray Ionization
Santos, V. G., Regiani, T., Dias, F. F. G., Romão, W., Jara, J. L. P., Klitzke, C. F., Coelho, F., & Eberlin, M. N. (2011) · Analytical Chemistry · doi:10.1021/ac102765z · Cited by 143
Approaching clinical proteomics: current state and future fields of application in fluid proteomics
Apweiler, R., Aslanidis, C., Deufel, T., Gerstner, A., Hansen, J., Hochstrasser, D., Kellner, R., Kubicek, M., Lottspeich, F., Maser, E., et al. (2009) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2009.167 · Cited by 138
Rosu, F. (2002) · Nucleic Acids Research · doi:10.1093/nar/gnf081 · Cited by 143
Formation of Disulfide Bonds in Synthetic Peptides and Proteins
Andreu, D., Alberício, F., Solé, N. A., Munson, M., Ferrer, M., & Bárány, G. (2003) · Humana Press eBooks · doi:10.1385/0-89603-273-6:91 · Cited by 144
Rosati, S., Yang, Y., Barendregt, A., & Heck, A. J. R. (2014) · Nature Protocols · doi:10.1038/nprot.2014.057 · Cited by 153
Glycosaminoglycans detection methods: Applications of mass spectrometry
Kubaski, F., Osago, H., Mason, R. W., Yamaguchi, S., Kobayashi, H., Tsuchiya, M., Orii, T., & Tomatsu, S. (2016) · Molecular Genetics and Metabolism · doi:10.1016/j.ymgme.2016.09.005 · Cited by 155
Verheggen, K., Ræder, H., Berven, F. S., Martens, L., Barsnes, H., & Vaudel, M. (2020) · Mass Spectrometry Reviews · doi:10.1002/mas.21543 · Cited by 132
“Two ionization techniques are principally used in proteomics: electrospray ionization (Fenn et al., 1989) and matrix assisted laser desorption ionization (MALDI) (Karas et al., 1985; Tanaka et al., 1988; Soltwisch et al., 2009).”
MethodWang, X., Ding, C., & Wang, L. (1998) · Physical Review Letters · doi:10.1103/physrevlett.81.3351 · Cited by 142
Serum Proteomics in Cancer Diagnosis and Management
Rosenblatt, K. P., BRYANT-GREENWOOD, P. K., Killian, J. K., Mehta, A. I., Geho, D. H., Espina, V. A., Petricoin, E. F., & Liotta, L. A. (2004) · Annual Review of Medicine · doi:10.1146/annurev.med.55.091902.105237 · Cited by 152
Banoub, J. H., Newton, R. P., Esmans, E. L., Ewing, D. F., & Mackenzie, G. (2005) · Chemical Reviews · doi:10.1021/cr030040w · Cited by 159
Li, D., Wang, L., Fei, F., Hou, Y., Luo, J., Wei‐Chen, Zeng, R., Wu, J., Lu, J., Di, G., et al. (2006) · PROTEOMICS · doi:10.1002/pmic.200500617 · Cited by 149
A Very Stable High Throughput Taylor Cone-jet in Electrohydrodynamics
Morad, M. R., Rajabi, A., Razavi, M., & Pejman, S. R. (2016) · Scientific Reports · doi:10.1038/srep38509 · Cited by 154
Becker, J. S., Zoriy, M. V., Becker, J. S., Dobrowolska, J., & Matusch, A. (2007) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b701558e · Cited by 141
Going beyond electrospray: mass spectrometric studies of chemical reactions in and on liquids
Ingram, A. J., Boeser, C. L., & Zare, R. N. (2016) · Chemical Science · doi:10.1039/c5sc02740c · Cited by 138
All-optical mass sensing with coupled mechanical resonator systems
Li, J., & Zhu, K. (2012) · Physics Reports · doi:10.1016/j.physrep.2012.11.003 · Cited by 140
Role of analytical ultracentrifugation in assessing the aggregation of protein biopharmaceuticals
Berkowitz, S. A. (2006) · The AAPS Journal · doi:10.1208/aapsj080368 · Cited by 140
Investigation of tyrosine nitration in proteins by mass spectrometry
Petersson, A., Steen, H., Kalume, D. E., Caidahl, K., & Roepstorff, P. (2001) · Journal of Mass Spectrometry · doi:10.1002/jms.161 · Cited by 141
Dynamics of Drop Formation in an Electric Field
Notz, P. K., & Basaran, O. A. (1999) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1999.6136 · Cited by 140
Protonation in electrospray mass spectrometry: Wrong-way-round or right-way-round?
Zhou, S., & Cook, K. D. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00174-4 · Cited by 140
Gibson, B. W., Melaugh, W., Phillips, N. J., Apicella, M. A., Campagnari, A. A., & Griffiss, J. M. (1993) · Journal of Bacteriology · doi:10.1128/jb.175.9.2702-2712.1993 · Cited by 140
A novel method for the preparation of starch films and coatings
Pareta, R. A., & Edirisinghe, M. J. (2005) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2005.09.018 · Cited by 139
Vibrational spectral signature of the proton defect in the three-dimensional H + (H 2 O) 21 cluster
Fournier, J. A., Johnson, C. J., Wolke, C. T., Weddle, G. H., Wolk, A. B., & Johnson, M. A. (2014) · Science · doi:10.1126/science.1253788 · Cited by 139
Visible and ultraviolet spectroscopy of gas phase protein ions
Antoine, R., & Dugourd, P. (2011) · Physical Chemistry Chemical Physics · doi:10.1039/c1cp21531k · Cited by 139
Metadata
- Authors
- Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M.
- Affiliations
- Yale University (US)
- Venue
- Science
- Published
- 1989-10-06
- Volume
- 246
- Issue
- 4926
- Pages
- 64-71
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2073292063
- Cited by
- 7,634
- References
- 32
- Citations by year
- 2026: 126 · 2025: 157 · 2024: 177 · 2023: 194 · 2022: 164 · 2021: 213 · 2020: 220 · 2019: 240 · 2018: 227 · 2017: 255 · 2016: 251 · 2015: 316 · 2014: 327 · 2013: 340 · 2012: 395
- FWCI
- 11.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- electrospray ionization, large biomolecules, multiply charged ions, biopolymers, oligonucleotides, proteins, soft ionization
- MeSH terms
- Ions, Molecular Weight, Proteins, Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.