Electrospray Ionization for Mass Spectrometry of Large Biomolecules
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Electrospray ionization has recently emerged as a powerful technique for producing intact ions in vacuo from large and complex species in solution. To an extent greater than has previously been possible with the more familiar "soft" ionization methods, this technique makes the power and elegance of mass spectrometric analysis applicable to the large and fragile polar molecules that play such vital roles in biological systems. The distinguishing features of electrospray spectra for large molecules are coherent sequences of peaks whose component ions are multiply charged, the ions of each peak differing by one charge from those of adjacent neighbors in the sequence. Spectra have been obtained for biopolymers including oligonucleotides and proteins, the latter having molecular weights up to 130,000, with as yet no evidence of an upper limit.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electrospray ionization is a soft ionization technique that accomplishes the transfer of ions from solution to a gas phase [51].”
In the citing paper
“Although several ionization techniques are available, ESI is still predominately utilized for top-down proteomics as it is easy to interface with common LC systems [92].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [92]
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Self-citationDole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Self-citationOn the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
On-line mass spectrometric detection for capillary zone electrophoresis
Olivares, J. A., Nguyen, N. T., Yonker, C. R., & Smith, R. D. (1987) · Analytical Chemistry · doi:10.1021/ac00135a034 · Cited by 635
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Self-citationNegative ion production with the electrospray ion source
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a046 · Cited by 581
Self-citation
Research works printed but not linked: 11
- Abuaf, N., Rarefied Gas Dynamics 2: 1317 (1967).
- ANDERSON, J.B., ENTROPIE 18: 33 (1976).
- Karas M. paper presented at the American Society for Mass Spectrometry (ASMS) Workshop on Ion Desorption Mechanisms Sanibel Island FL January (1989).
- Karas M. paper presented at the 11th International Mass Spectrometry Conference Bordeaux France (1988).
- MANN M THESIS YALE U (1989).
- Mann, M., Proceedings of the 36th Annual Conference on Mass Spectrometry and Allied Topics: 771 (1988).
- Mann, M., Proceedings of the 36th Annual Conference on Mass Spectrometry and Allied Topics: 1207 (1988).
- SIMONS, D.S., INT J MASS SPECTROM 15: 291 (1974).
- Smith R. D. paper presented at the 5th (Montreux) Symposium on LC-MS Freidburg November (1988).
- Vestal, M. L., Mass Spectrometry in the Health and Life Sciences: 99 (1985).
- Whitehouse, C. M., Proceedings o fthe 14th Intemational Symposium on Rarefied Gas Dynamics: 857 (1985).
Cited by
Items 1,001–1,027 of 1,027
Hexameric Supramolecular Scaffold Orients Carbohydrates To Sense Bacteria
Grünstein, D., Maglinao, M., Kikkeri, R. V., Collot, M., Barylyuk, K., Lepenies, B., Kamena, F., Zenobi, R., & Seeberger, P. H. (2011) · Journal of the American Chemical Society · doi:10.1021/ja2036767 · Cited by 93
Strategies for Analysis of the Glycosylation of Proteins: Current Status and Future Perspectives
Brooks, S. A. (2009) · Molecular Biotechnology · doi:10.1007/s12033-009-9184-6 · Cited by 88
“Fast atom bombardment (FAB) and electrospray ionisation (ESI) MS provides data that can be interpreted to determine monosaccharide linkage and position [116].”
BackgroundElschenbroich, S., & Kislinger, T. (2010) · Molecular BioSystems · doi:10.1039/c0mb00159g · Cited by 98
LeDuc, R. D., Fellers, R. T., Early, B. P., Greer, J. B., Thomas, P. M., & Kelleher, N. L. (2014) · Journal of Proteome Research · doi:10.1021/pr401277r · Cited by 85
From QCEIMS to QCxMS: A Tool to Routinely Calculate CID Mass Spectra Using Molecular Dynamics
Koopman, J., & Grimme, S. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.1c00098 · Cited by 80
Electrosprayed polymer particles: Effect of the solvent properties
Park, C. H., & Lee, J. (2009) · Journal of Applied Polymer Science · doi:10.1002/app.30498 · Cited by 80
Polyphyletic photosynthetic reaction centre genes in oligotrophic marine Gammaproteobacteria
Cho, J., Stapels, M. D., Morris, R. M., Vergin, K. L., Schwalbach, M. S., Givan, S. A., Barofsky, D. F., & Giovannoni, S. J. (2007) · Environmental Microbiology · doi:10.1111/j.1462-2920.2007.01264.x · Cited by 72
ClipsMS: An Algorithm for Analyzing Internal Fragments Resulting from Top-Down Mass Spectrometry
(2021) · doi:10.1021/acs.jproteome.0c00952 · Cited by 72
Proteomics in heart failure: top-down or bottom-up?
Gregorich, Z. R., Chang, Y.-H., & Ge, Y. (2014) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-014-1471-9 · Cited by 69
“The minor proteolytic fragment, cTnI A[16-205]K, was observed.”
Valeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Recent Developments in Gas-Phase Ion/Ion Reactions for Analytical Mass Spectrometry
Foreman, D. J., & McLuckey, S. A. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05014 · Cited by 65
“There are several distinct advantages to performing experiments within the confines of an electrodynamic trap: (1) independent control/optimization of reactant species, (2) well defined reaction conditions, and (3) MSn capabilities in conjunction with ion/ion reactions.”
BackgroundInfluentialMass Spectrometric Analysis of Histone Proteoforms
Yuan, Z.-F., Arnaudo, A. M., & Garcia, B. A. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-015959 · Cited by 64
“Then the ion source converts sample molecules to ions, using electrospray ionization (ESI) or matrix-assisted laser desorption/ionization (MALDI) (8, 9).”
MethodHe, S., Xu, Z., & Han, X. (2025) · Molecular Neurodegeneration · doi:10.1186/s13024-025-00803-6 · Cited by 62
“Ionization methods are listed in box (a) ESI [114], electrospray ionization, creates ions by applying high voltage to a liquid to form an aerosol.”
Gavriilidou, A. F. M., Gülbakan, B., & Zenobi, R. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02478 · Cited by 53
Ion-ion proton transfer reactions of bio-ions involving noncovalent interactions: Holomyoglobin
Stephenson, J. L., Van Berkel, G. J., & McLuckey, S. A. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00023-8 · Cited by 51
Konijnenberg, A., Bannwarth, L., Yilmaz, D., Koçer, A., Venien‐Bryan, C., & Sobott, F. (2015) · Protein Science · doi:10.1002/pro.2703 · Cited by 45
Yang, X., Li, Y., Li, Y., Ye, D., Yuan, L., Sun, Y., Han, D., & Hu, Q. (2019) · Marine Drugs · doi:10.3390/md17040203 · Cited by 45
Ugrin, S. A., English, A. M., Syka, J. E. P., Bai, D. L., Anderson, L. C., Shabanowitz, J., & Hunt, D. F. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02290-8 · Cited by 44
“These challenges are simultaneously mitigated and compounded by use of electrospray ionization [1] (ESI), which enables direct coupling to HPLC to reduce sample complexity, but also ionizes each protein analyte to multiple charge states and divides the signal among several m/z peak isotopic envelopes [2].”
Toll, H., Berger, P., Hofmann, A., Hildebrandt, A., Oberacher, H., Lenhof, H. P., & Huber, C. G. (2006) · ELECTROPHORESIS · doi:10.1002/elps.200600022 · Cited by 42
The benefits (and misfortunes) of SDS in top-down proteomics
Kachuk, C., & Doucette, A. A. (2018) · Journal of Proteomics · doi:10.1016/j.jprot.2017.03.002 · Cited by 39
Bertoletti, L., Schappler, J., Colombo, R., Rudaz, S., Haselberg, R., Domínguez-Vega, E., Raimondi, S., Somsen, G. W., & De Lorenzi, E. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.10.010 · Cited by 25
(2022) · doi:10.3390/proteomes10030026 · Cited by 20
Bigler, L., Baumeler, A., Werner, C., & Hesse, M. (1996) · Helvetica Chimica Acta · doi:10.1002/hlca.19960790620 · Cited by 18
Smith, R., Brookes, C., Morris, M., & Barran, P. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c02331 · Cited by 14
Ion-ion proton transfer reactions of multiply-charged oligonucleotide cations
Stephenson, J. L., & McLuckey, S. A. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00176-6 · Cited by 11
Intact stable isotope labeled plasma proteins from the SILAC-labeled HepG2 secretome
Mangrum, J. B., Martin, E. J., Brophy, D. F., & Hawkridge, A. M. (2015) · PROTEOMICS · doi:10.1002/pmic.201400369 · Cited by 8
“The pursuit of clinically useful protein biomarkers has been revolutionized by MS-based proteomics technology since the introduction of electrospray [1] and MALDI [2].”
MethodLi, Y., Cavet, G., Zare, R. N., & Driver, T. (2024) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2409676121 · Cited by 6
“The nanoelectrospray ionization electrode was made of a stainless-steel wire (catalog #W224 from Scientific Instrument Services) mounted in an electrode holder (catalog #ESW-M15P from Warner Instruments with the silver replaced).”
Metadata
- Authors
- Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M.
- Affiliations
- Yale University (US)
- Venue
- Science
- Published
- 1989-10-06
- Volume
- 246
- Issue
- 4926
- Pages
- 64-71
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2073292063
- Cited by
- 7,634
- References
- 32
- Citations by year
- 2026: 126 · 2025: 157 · 2024: 177 · 2023: 194 · 2022: 164 · 2021: 213 · 2020: 220 · 2019: 240 · 2018: 227 · 2017: 255 · 2016: 251 · 2015: 316 · 2014: 327 · 2013: 340 · 2012: 395
- FWCI
- 11.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- electrospray ionization, large biomolecules, multiply charged ions, biopolymers, oligonucleotides, proteins, soft ionization
- MeSH terms
- Ions, Molecular Weight, Proteins, Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.