Electrospray Ionization for Mass Spectrometry of Large Biomolecules
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Electrospray ionization has recently emerged as a powerful technique for producing intact ions in vacuo from large and complex species in solution. To an extent greater than has previously been possible with the more familiar "soft" ionization methods, this technique makes the power and elegance of mass spectrometric analysis applicable to the large and fragile polar molecules that play such vital roles in biological systems. The distinguishing features of electrospray spectra for large molecules are coherent sequences of peaks whose component ions are multiply charged, the ions of each peak differing by one charge from those of adjacent neighbors in the sequence. Spectra have been obtained for biopolymers including oligonucleotides and proteins, the latter having molecular weights up to 130,000, with as yet no evidence of an upper limit.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electrospray ionization is a soft ionization technique that accomplishes the transfer of ions from solution to a gas phase [51].”
In the citing paper
“Although several ionization techniques are available, ESI is still predominately utilized for top-down proteomics as it is easy to interface with common LC systems [92].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [92]
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Self-citationDole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Self-citationOn the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
On-line mass spectrometric detection for capillary zone electrophoresis
Olivares, J. A., Nguyen, N. T., Yonker, C. R., & Smith, R. D. (1987) · Analytical Chemistry · doi:10.1021/ac00135a034 · Cited by 635
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Self-citationNegative ion production with the electrospray ion source
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a046 · Cited by 581
Self-citation
Research works printed but not linked: 11
- Abuaf, N., Rarefied Gas Dynamics 2: 1317 (1967).
- ANDERSON, J.B., ENTROPIE 18: 33 (1976).
- Karas M. paper presented at the American Society for Mass Spectrometry (ASMS) Workshop on Ion Desorption Mechanisms Sanibel Island FL January (1989).
- Karas M. paper presented at the 11th International Mass Spectrometry Conference Bordeaux France (1988).
- MANN M THESIS YALE U (1989).
- Mann, M., Proceedings of the 36th Annual Conference on Mass Spectrometry and Allied Topics: 771 (1988).
- Mann, M., Proceedings of the 36th Annual Conference on Mass Spectrometry and Allied Topics: 1207 (1988).
- SIMONS, D.S., INT J MASS SPECTROM 15: 291 (1974).
- Smith R. D. paper presented at the 5th (Montreux) Symposium on LC-MS Freidburg November (1988).
- Vestal, M. L., Mass Spectrometry in the Health and Life Sciences: 99 (1985).
- Whitehouse, C. M., Proceedings o fthe 14th Intemational Symposium on Rarefied Gas Dynamics: 857 (1985).
Cited by
Items 201–300 of 1,027
JEDLITSCHKY, G., LEIER, I., BUCHHOLZ, U., HUMMEL-EISENBEISS, J., BURCHELL, B., & KEPPLER, D. (1997) · Biochemical Journal · doi:10.1042/bj3270305 · Cited by 303
Protein identification in the post-genome era: the rapid rise of proteomics
JAMES, P. (1997) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583597003399 · Cited by 285
A Review on Quantitative Multiplexed Proteomics
Pappireddi, N., Martin, L., & Wühr, M. (2019) · ChemBioChem · doi:10.1002/cbic.201800650 · Cited by 299
Loo, J. A., Loo, R. R. O., Udseth, H. R., Edmonds, C. G., & Smith, R. D. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050303 · Cited by 291
O-GlcNAc profiling: from proteins to proteomes
Ma, J., & Hart, G. W. (2014) · Clinical Proteomics · doi:10.1186/1559-0275-11-8 · Cited by 276
“Shortly after FAB, the advent of electrospray ionization (ESI) [46] and matrix-assisted laser desorption-ionization (MALDI) [47], two ionization methods which are capable of directly ionizing involatile and labile biomolecules, have revolutionized the characterization of proteins/peptides.”
BackgroundInfluentialQuantitative proteomics: challenges and opportunities in basic and applied research
Schubert, O. T., Röst, H. L., Collins, B. C., Rosenberger, G., & Aebersold, R. (2017) · Nature Protocols · doi:10.1038/nprot.2017.040 · Cited by 274
‘Top down’ protein characterization via tandem mass spectrometry
Reid, G. E., & McLuckey, S. A. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.346 · Cited by 285
Origin of Asymmetric Charge Partitioning in the Dissociation of Gas-Phase Protein Homodimers
Jurchen, J. C., & Williams, E. R. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0211508 · Cited by 284
Mass spectrometry: from proteomics to metabolomics and lipidomics
Griffiths, W. J., & Wang, Y. (2009) · Chemical Society Reviews · doi:10.1039/b618553n · Cited by 271
Chip-based genotyping by mass spectrometry
Tang, K., Fu, D.-J., Julien, D., Braun, A., Cantor, C. R., & Köster, H. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10016 · Cited by 286
Krokhin, O. V., Craig, R., Spicer, V., Ens, W., Standing, K. G., Beavis, R. C., & Wilkins, J. A. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400031-mcp200 · Cited by 284
“However, the optimum conditions for operation of the HPLC and the mass spectrometer are usually different, so on-line coupling of the HPLC to the mass spectrometer, as commonly used for ESI, may require undesirable compromises for both approaches, as well as requiring strict time constraints.”
BackgroundInfluentialSinz, A. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.559 · Cited by 276
Carr, S. A., Huddleston, M. J., & Bean, M. F. (1993) · Protein Science · doi:10.1002/pro.5560020207 · Cited by 284
“Electrospray (ES), in contrast to other mass spectrometry (MS) techniques such as fast atom bombardment MS, produces multiply (as opposed to singly) charged molecular species if the analyte contains more than one possible site for proton attachment (Fenn et al., 1989).”
Santos, L. S., Pavam, C. H., Almeida, W. P., Coelho, F., & Eberlin, M. N. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200460059 · Cited by 280
Atmospheric pressure ion sources
Covey, T. R., Thomson, B. A., & Schneider, B. B. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20246 · Cited by 264
“The appearance of these atmospheric gas phase ions, as indicated by the presence of multiple charges (Covey et al., 1988; Fenn et al., 1989), reflect their solution state chemistry at the time of emission.”
BackgroundMetabolomics as a tool for cardiac research
Griffin, J. L., Atherton, H., Shockcor, J., & Atzori, L. (2011) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.138 · Cited by 278
“In electrospray ionization, macromolecules are dissolved in a liquid that is then turned into a fine aerosol of charged particles by its introduction into the mass spectrometer”
BackgroundProgress in monitoring, modeling and control of bioprocesses during the last 20 years
Schügerl, K. (2001) · Journal of Biotechnology · doi:10.1016/s0168-1656(00)00361-8 · Cited by 278
Whiteaker, J. R., Zhao, L., Zhang, H. Y., Feng, L.-C., Piening, B. D., Anderson, L., & Paulovich, A. G. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2006.12.023 · Cited by 270
“With the development of soft ionization techniques [10,11], it is now possible to extend its application to quantifying peptide components of biomarker candidates in clinical samples.”
BackgroundApplication of ’omics technologies to biomarker discovery in inflammatory lung diseases
Wheelock, C. E., Goss, V. M., Balgoma, D., Nicholas, B., Brandsma, J., Skipp, P. J., Snowden, S., Burg, D., D'Amico, A., Horvath, I., et al. (2013) · European Respiratory Journal · doi:10.1183/09031936.00078812 · Cited by 272
Protein identification: The origins of peptide mass fingerprinting
Henzel, W. J., Watanabe, C., & Stults, J. T. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00214-9 · Cited by 268
“Two new ionization techniques, electrospray ionization (ESI) [ 8 ] and matrix assisted laser desorption/ ionization (MALDI) [9, 10], quickly eclipsed the performance of FAB and PDMS.”
MethodFunctional analysis of natural microbial consortia using community proteomics
VerBerkmoes, N. C., Denef, V. J., Hettich, R. L., & Banfield, J. F. (2009) · Nature Reviews Microbiology · doi:10.1038/nrmicro2080 · Cited by 269
“After LC separation, charged peptides are transferred into the gas phase for MS measurements, either by electrospray ionizatio”
MethodFrontiers in the spectroscopy of mass-selected molecular ions
Duncan, M. A. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00366-3 · Cited by 270
Sonic Spray Ionization Method for Atmospheric Pressure Ionization Mass Spectrometry
Hirabayashi, A., Sakairi, M., & Koizumi, H. (1994) · Analytical Chemistry · doi:10.1021/ac00096a025 · Cited by 273
López-Herrera, J. M., Popinet, S., & Herrada, M. A. (2011) · Journal of Computational Physics · doi:10.1016/j.jcp.2010.11.042 · Cited by 265
“For example, many technical and industrial processes which require supplying liquids in the form of small droplets, such as ink jet printing, fuel atomization, or many biotechnological applications, involve the breakup of charged jets [6, 7, 8], which is referred to as EHD liquid spraying.”
BackgroundSjöström, Lundin, Molberg, Körner, Mcadam, Anthonsen, Quarsten, Norén, Roepstorff, Thorsby, et al. (1998) · Scandinavian Journal of Immunology · doi:10.1046/j.1365-3083.1998.00397.x · Cited by 269
Analysis of Noncovalent Complexes of DNA and RNA by Mass Spectrometry
Hofstadler, S. A., & Griffey, R. H. (2001) · Chemical Reviews · doi:10.1021/cr990105o · Cited by 265
Proteomic landscape of Alzheimer’s Disease: novel insights into pathogenesis and biomarker discovery
Bai, B., Vanderwall, D., Li, Y., Wang, X., Poudel, S., Wang, H., Dey, K. K., Chen, P.-C., Yang, K., & Peng, J. (2021) · Molecular Neurodegeneration · doi:10.1186/s13024-021-00474-z · Cited by 257
The ferritin superfamily: Supramolecular templates for materials synthesis
Uchida, M., Kang, S., Reichhardt, C., Harlen, K., & Douglas, T. (2010) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2009.12.005 · Cited by 263
Brügger, B. (2014) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-060713-035324 · Cited by 264
Collisional Activation of Large Multiply Charged Ions Using Fourier Transform Mass Spectrometry
Senko, M. W., Speir, J. P., & McLafferty, F. W. (1994) · Analytical Chemistry · doi:10.1021/ac00090a003 · Cited by 263
On the structure of an electrostatic spray of monodisperse droplets
Tang, K., & Gomez, A. (1994) · Physics of Fluids · doi:10.1063/1.868182 · Cited by 266
Microbial metabolites in the marine carbon cycle
Moran, M. A., Kujawinski, E. B., Schroer, W. F., Amin, S. A., Bates, N. R., Bertrand, E. M., Braakman, R., Brown, C. T., Covert, M. W., Doney, S. C., et al. (2022) · Nature Microbiology · doi:10.1038/s41564-022-01090-3 · Cited by 249
Redox Proteomics: Chemical Principles, Methodological Approaches and Biological/Biomedical Promises
Bachi, A., Dalle-Donne, I., & Scaloni, A. (2013) · Chemical Reviews · doi:10.1021/cr300073p · Cited by 251
Electrospray and Tandem Mass Spectroscopy As Tools for Anthocyanin Characterization
Giusti, M. M., Rodríguez-Saona, L. E., Griffin, D., & Wrolstad, R. E. (1999) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf981242+ · Cited by 257
Ultrafast dynamics in isolated molecules and molecular clusters
Hertel, I. V., & Radloff, W. (2006) · Reports on Progress in Physics · doi:10.1088/0034-4885/69/6/r06 · Cited by 265
“The conceptually simple device first introduced into molecular beam techniques by Fenn et al. (1989) and (1990) has proven to have tremendous potential for the ”identification and structure analyzes of biological macromolecules” such that the Nobel prize 2002 was awarded to John Fenn for these…”
BackgroundBioinspired Energy Conversion Systems for Hydrogen Production and Storage
Fukuzumi, S. (2008) · European Journal of Inorganic Chemistry · doi:10.1002/ejic.200701369 · Cited by 261
Milk allergens, their characteristics and their detection in food: A review
Monaci, L., Tregoat, V., van Hengel, A. J., & Anklam, E. (2006) · European Food Research and Technology · doi:10.1007/s00217-005-0178-8 · Cited by 259
Tang, L., & Kebarle, P. (1991) · Analytical Chemistry · doi:10.1021/ac00023a009 · Cited by 260
Ifa, D. R., Wiseman, J. M., Song, Q., & Cooks, R. G. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.08.003 · Cited by 261
Gao, L., Cooks, R. G., & Ouyang, Z. (2008) · Analytical Chemistry · doi:10.1021/ac800014v · Cited by 258
Crossing epigenetic frontiers: the intersection of novel histone modifications and diseases
Yao, W., Hu, X., & Wang, X. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01918-w · Cited by 208
“445,446 MS has emerged as the method of choice for the identi fi cation and quanti fi cation of HPTMs due to its objectivity, comprehensiveness, and precise quanti fi cation.”
MethodKachala, V. V., Khemchyan, L. L., Kashin, A. S., Orlov, N. V., Grachev, A. A., Zalesskiy, S. S., & Ananikov, V. P. (2013) · Russian Chemical Reviews · doi:10.1070/rc2013v082n07abeh004413 · Cited by 262
Sato, S., Soga, T., Nishioka, T., & Tomita, M. (2004) · The Plant Journal · doi:10.1111/j.1365-313x.2004.02187.x · Cited by 259
Protein disulfide bond determination by mass spectrometry
Gorman, J. J., Wallis, T. P., & Pitt, J. J. (2002) · Mass Spectrometry Reviews · doi:10.1002/mas.10025 · Cited by 258
van den Heuvel, R. H. H., van Duijn, E., Mazon, H., Synowsky, S. A., Lorenzen, K., Versluis, C., Brouns, S. J. J., Langridge, D., van der Oost, J., Hoyes, J., et al. (2006) · Analytical Chemistry · doi:10.1021/ac061039a · Cited by 252
Romero-Sanz, I., Bocanegra, R., Fernandez de la Mora, J., & Gamero-Castaño, M. (2003) · Journal of Applied Physics · doi:10.1063/1.1598281 · Cited by 257
Liquid Chromatography/Mass Spectrometry of Phospholipids using Electrospray Ionization
Kim, H.-Y., Wang, T.-C. L., & Ma, Y.-C. (1994) · Analytical Chemistry · doi:10.1021/ac00094a020 · Cited by 259
Mass Spectrometric Profiling of Intact Biological Tissue by Using Desorption Electrospray Ionization
Wiseman, J. M., Puolitaival, S. M., Takáts, Z., Cooks, R. G., & Caprioli, R. M. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200502362 · Cited by 255
Unbiased spatial proteomics with single-cell resolution in tissues
Mund, A., Brunner, A.-D., & Mann, M. (2022) · Molecular Cell · doi:10.1016/j.molcel.2022.05.022 · Cited by 259
Self-citationA review of chromatographic methods for the assessment of phospholipids in biological samples
Peterson, B. L., & Cummings, B. S. (2006) · Biomedical Chromatography · doi:10.1002/bmc.563 · Cited by 253
“ESI was developed in 1989 by John Fenn and co-workers (Fenn et al., 1989) and involves dissolving the sample in a solvent that passes through a narrow orifice in the ion source, creating a spray.”
MethodLarsen, M. R., Trelle, M. B., Thingholm, T. E., & Jensen, O. N. (2006) · BioTechniques · doi:10.2144/000112201 · Cited by 251
“The availability of robust and sensitive matrix-assisted laser desorption/ionization MS (MALDIMS) (4) and electrospray ionization MS (ESI-MS) (5) instruments makes advanced MS technology accessible to molecular cell biologists, biochemists, and proteomics researchers.”
BackgroundSchnier, P. D., Gross, D. S., & Williams, E. R. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00532-3 · Cited by 258
Clusters: A bridge across the disciplines of physics and chemistry
Jena, P., & Castleman, A. W. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0601782103 · Cited by 252
Swan, A. L., Mobasheri, A., Allaway, D., Liddell, S., & Bacardit, J. (2013) · OMICS: A Journal of Integrative Biology · doi:10.1089/omi.2013.0017 · Cited by 249
“Electro-spray ionization (ESI) (Fenn et al., 1989) is a common method used for the ionization of molecules, however other methods are becoming increasingly popular, including matrix-assisted laser desorption/ionization (MALDI), from which surface-enhanced laser desorption ionization (SELDI) has been developed (Domon a…”
MethodInfluentialBarnidge, D. R., Goodmanson, M. K., Klee, G. G., & Muddiman, D. C. (2004) · Journal of Proteome Research · doi:10.1021/pr049963d · Cited by 253
Sabino, A. A., Machado, A. H. L., Correia, C. R. D., & Eberlin, M. N. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200353076 · Cited by 254
Proteomics in Early Detection of Cancer
Srinivas, P. R., Srivastava, S., Hanash, S., & Wright, G. L. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.10.1901 · Cited by 254
Electrohydrodynamic atomization for biodegradable polymeric particle production
Xie, J., Lim, L. K., Phua, Y., Hua, J., & Wang, C.-H. (2006) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2006.06.037 · Cited by 251
Collision cross sections for protein ions
Covey, T., & Douglas, D. J. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85025-s · Cited by 253
Rosell-Llompart, J., & Fernández de la Mora, J. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90204-6 · Cited by 252
Infrared multiple photon dissociation spectroscopy of ions in Penning traps
Eyler, J. R. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20217 · Cited by 250
“, 1994) has been the use of IRMPD to dissociate ions formed from large biomolecules by electrospray (Dole et al., 1968; Fenn et al., 1989) or matrix assisted laser desorption (Karas et al.”
Miniaturized continuous flow reaction vessels: influence on chemical reactions
Brivio, M., Verboom, W., & Reinhoudt, D. N. (2006) · Lab on a Chip · doi:10.1039/b510856j · Cited by 249
Gozzo, F. C., Santos, L. S., Augusti, R., Consorti, C. S., Dupont, J., & Eberlin, M. N. (2004) · Chemistry – A European Journal · doi:10.1002/chem.200305742 · Cited by 246
Christofi, E., & Barran, P. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00600 · Cited by 233
SPARC is a source of copper-binding peptides that stimulate angiogenesis
Lane, T. F., Iruela-Arispe, M. L., Johnson, R. S., & Sage, E. H. (1994) · The Journal of cell biology · doi:10.1083/jcb.125.4.929 · Cited by 249
“…used in these experiments were determined by electrospray-mass spectrometry by continuous infusion of sample into a triple quadrapole instrument (SCIEX API Ill; SC1EX, Thornhill, Ontario, Canada) equipped with a nebulization-assisted elcctrospray ion source (Covey et al., 1988; Fenn et al., 1989).”
MethodThe speciation of the proteome
Jungblut, P. R., Holzhütter, H. G., Apweiler, R., & Schlüter, H. (2008) · Chemistry Central Journal · doi:10.1186/1752-153x-2-16 · Cited by 237
Application of mass spectrometry for identification and structural studies of flavonoid glycosides
Stobiecki, M. (2000) · Phytochemistry · doi:10.1016/s0031-9422(00)00091-1 · Cited by 245
Chemical Cross-linking and Mass Spectrometry for Protein Structural Modeling
Back, J. W., de Jong, L., Muijsers, A. O., & de Koster, C. G. (2003) · Journal of Molecular Biology · doi:10.1016/s0022-2836(03)00721-6 · Cited by 240
Statistical Characterization of Ion Trap Tandem Mass Spectra from Doubly Charged Tryptic Peptides
Tabb, D. L., Smith, L. L., Breci, L. A., Wysocki, V. H., Lin, D., & Yates, J. R. (2003) · Analytical Chemistry · doi:10.1021/ac026122m · Cited by 244
Electrospray ionization combined with ion trap mass spectrometry
Van Berkel, G. J., Glish, G. L., & McLuckey, S. A. (1990) · Analytical Chemistry · doi:10.1021/ac00212a016 · Cited by 246
Mass spectrometry–based functional proteomics: from molecular machines to protein networks
Köcher, T., & Superti-Furga, G. (2007) · Nature Methods · doi:10.1038/nmeth1093 · Cited by 241
An Introduction to Mass Spectrometry-Based Proteomics
Shuken, S. R. (2023) · Journal of Proteome Research · doi:10.1021/acs.jproteome.2c00838 · Cited by 223
Cold‐spray ionization mass spectrometry: principle and applications
Yamaguchi, K. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.488 · Cited by 241
Duffin, K. L., Henion, J. D., & Shieh, J. J. (1991) · Analytical Chemistry · doi:10.1021/ac00017a023 · Cited by 241
Automated de novo sequencing of proteins by tandem high-resolution mass spectrometry
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.19.10313 · Cited by 243
Liu, X. R., Zhang, M. M., & Gross, M. L. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00815 · Cited by 242
De Vijlder, T., Valkenborg, D., Lemière, F., Romijn, E. P., Laukens, K., & Cuyckens, F. (2018) · Mass Spectrometry Reviews · doi:10.1002/mas.21551 · Cited by 229
On the Scalability and Requirements of Whole Protein Mass Spectrometry
Compton, P. D., Zamdborg, L., Thomas, P. M., & Kelleher, N. L. (2011) · Analytical Chemistry · doi:10.1021/ac2010795 · Cited by 243
Konermann, L. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1739-3 · Cited by 243
[8] Mass spectrometry of carbohydrate-containing biopolymers
Dell, A., Reason, A. J., Khoo, K.-H., Panico, M., McDowell, R. A., & Morris, H. R. (1994) · Methods in Enzymology · doi:10.1016/0076-6879(94)30010-0 · Cited by 242
Integration of mass spectrometry in analytical biotechnology
Carr, S. A., Hemling, M. E., Bean, M. F., & Roberts, G. D. (1991) · Analytical Chemistry · doi:10.1021/ac00024a003 · Cited by 241
Gas-phase ions of solute species from charged droplets of solutions
Nguyen, S., & Fenn, J. B. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609969104 · Cited by 232
Self-citationMetabolomics: current state and evolving methodologies and tools
Oldiges, M., Lütz, S., Pflug, S., Schroer, K., Stein, N., & Wiendahl, C. (2007) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-007-1029-2 · Cited by 238
“Because of the typically polar to ionic chemical characteristics of metabolites, the electrospray iononisation (ESI; Fenn et al. 1989; Tarr et al. 2000) is one very important technique for metabolome analysis.”
BackgroundCastro-Perez, J. M., Kamphorst, J., DeGroot, J., Lafeber, F., Goshawk, J., Yu, K., Shockcor, J. P., Vreeken, R. J., & Hankemeier, T. (2010) · Journal of Proteome Research · doi:10.1021/pr901094j · Cited by 236
THE SURFACE CHARGE IN ELECTROSPRAYING: ITS NATURE AND ITS UNIVERSAL SCALING LAWS
Gañán-Calvo, A. M. (1999) · Journal of Aerosol Science · doi:10.1016/s0021-8502(98)00780-0 · Cited by 239
Ion/ion chemistry of high-mass multiply charged ions
McLuckey, S. A., & Stephenson, J. L. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:6<369::aid-mas1>3.0.co;2-j · Cited by 233
Aspects of native proteins are retained in vacuum
Ruotolo, B. T., & Robinson, C. V. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.08.020 · Cited by 235
Syntheses of Isoquinoline and Substituted Quinolines in Charged Microdroplets
Banerjee, S., & Zare, R. N. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201507805 · Cited by 230
Recent advances and trends in the liquid-chromatography–mass spectrometry analysis of flavonoids
de Villiers, A., Venter, P., & Pasch, H. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.11.077 · Cited by 228
Valentine, S. J., Anderson, J. G., Ellington, A. D., & Clemmer, D. E. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp970217o · Cited by 234
A proteomic approach for the study ofSaccharomyces cerevisiae cell wall biogenesis
Pardo, M., Ward, M. A., Bains, S., Molina, M., Blackstock, W. P., Gil, C., & Nombela, C. (2000) · Electrophoresis · doi:10.1002/1522-2683(20001001)21:16<3396::aid-elps3396>3.0.co;2-j · Cited by 90
Müller, M. Q., Dreiocker, F., Ihling, C. H., Schäfer, M., & Sinz, A. (2010) · Analytical Chemistry · doi:10.1021/ac101241t · Cited by 231
Accelerated CarbonCarbon Bond‐Forming Reactions in Preparative Electrospray
Müller, T., Badu‐Tawiah, A., & Cooks, R. G. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201206632 · Cited by 230
MALDI-MS-based imaging of small molecules and proteins in tissues
Reyzer, M. L., & Caprioli, R. M. (2007) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.11.035 · Cited by 228
Suckau, D., Mak, M., & Przybylski, M. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5630 · Cited by 230
Recent developments in detection for microfluidic systems
Mogensen, K. B., Klank, H., & Kutter, J. P. (2004) · ELECTROPHORESIS · doi:10.1002/elps.200406108 · Cited by 231
van Honschoten, J. W., Brunets, N., & Tas, N. R. (2010) · Chemical Society Reviews · doi:10.1039/b909101g · Cited by 228
Shackleton, C. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.02.017 · Cited by 226
Conformer-dependent proton-transfer reactions of ubiquitin ions
Valentine, S. J., Counterman, A. E., & Clemmer, D. E. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00085-8 · Cited by 230
Reaction products in mass spectrometry elucidated with infrared spectroscopy
Polfer, N. C., & Oomens, J. (2007) · Physical Chemistry Chemical Physics · doi:10.1039/b702993b · Cited by 227
Metadata
- Authors
- Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M.
- Affiliations
- Yale University (US)
- Venue
- Science
- Published
- 1989-10-06
- Volume
- 246
- Issue
- 4926
- Pages
- 64-71
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2073292063
- Cited by
- 7,634
- References
- 32
- Citations by year
- 2026: 126 · 2025: 157 · 2024: 177 · 2023: 194 · 2022: 164 · 2021: 213 · 2020: 220 · 2019: 240 · 2018: 227 · 2017: 255 · 2016: 251 · 2015: 316 · 2014: 327 · 2013: 340 · 2012: 395
- FWCI
- 11.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- electrospray ionization, large biomolecules, multiply charged ions, biopolymers, oligonucleotides, proteins, soft ionization
- MeSH terms
- Ions, Molecular Weight, Proteins, Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.