Electrospray Ionization for Mass Spectrometry of Large Biomolecules
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Electrospray ionization has recently emerged as a powerful technique for producing intact ions in vacuo from large and complex species in solution. To an extent greater than has previously been possible with the more familiar "soft" ionization methods, this technique makes the power and elegance of mass spectrometric analysis applicable to the large and fragile polar molecules that play such vital roles in biological systems. The distinguishing features of electrospray spectra for large molecules are coherent sequences of peaks whose component ions are multiply charged, the ions of each peak differing by one charge from those of adjacent neighbors in the sequence. Spectra have been obtained for biopolymers including oligonucleotides and proteins, the latter having molecular weights up to 130,000, with as yet no evidence of an upper limit.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electrospray ionization is a soft ionization technique that accomplishes the transfer of ions from solution to a gas phase [51].”
In the citing paper
“Although several ionization techniques are available, ESI is still predominately utilized for top-down proteomics as it is easy to interface with common LC systems [92].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [92]
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Self-citationDole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Self-citationOn the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
On-line mass spectrometric detection for capillary zone electrophoresis
Olivares, J. A., Nguyen, N. T., Yonker, C. R., & Smith, R. D. (1987) · Analytical Chemistry · doi:10.1021/ac00135a034 · Cited by 635
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Self-citationNegative ion production with the electrospray ion source
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a046 · Cited by 581
Self-citation
Research works printed but not linked: 11
- Abuaf, N., Rarefied Gas Dynamics 2: 1317 (1967).
- ANDERSON, J.B., ENTROPIE 18: 33 (1976).
- Karas M. paper presented at the American Society for Mass Spectrometry (ASMS) Workshop on Ion Desorption Mechanisms Sanibel Island FL January (1989).
- Karas M. paper presented at the 11th International Mass Spectrometry Conference Bordeaux France (1988).
- MANN M THESIS YALE U (1989).
- Mann, M., Proceedings of the 36th Annual Conference on Mass Spectrometry and Allied Topics: 771 (1988).
- Mann, M., Proceedings of the 36th Annual Conference on Mass Spectrometry and Allied Topics: 1207 (1988).
- SIMONS, D.S., INT J MASS SPECTROM 15: 291 (1974).
- Smith R. D. paper presented at the 5th (Montreux) Symposium on LC-MS Freidburg November (1988).
- Vestal, M. L., Mass Spectrometry in the Health and Life Sciences: 99 (1985).
- Whitehouse, C. M., Proceedings o fthe 14th Intemational Symposium on Rarefied Gas Dynamics: 857 (1985).
Cited by
Items 301–400 of 1,027
De novo sequencing of peptides by MS/MS
Seidler, J., Zinn, N., Boehm, M. E., & Lehmann, W. D. (2010) · PROTEOMICS · doi:10.1002/pmic.200900459 · Cited by 221
“[44] Armirotti, A., Millo, E., Damonte, G., How to discriminate between leucine and isoleucine by low energy ESI-TRAP MSn. J.”
InfluentialStable-Isotope Dilution LC–MS for Quantitative Biomarker Analysis
Ciccimaro, E., & Blair, I. A. (2010) · Bioanalysis · doi:10.4155/bio.09.185 · Cited by 226
A novel method for the determination of posttranscriptional modification in RNA by mass spectrometry
Kowalak, J. A., Pomerantz, S. C., Crain, P. F., & McCloskey, J. A. (1993) · Nucleic Acids Research · doi:10.1093/nar/21.19.4577 · Cited by 228
Gas-phase folding and unfolding of cytochrome c cations.
Wood, T. D., Chorush, R. A., Wampler, F. M., Little, D. P., O'Connor, P. B., & McLafferty, F. W. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.7.2451 · Cited by 232
Supercharged Protein and Peptide Ions Formed by Electrospray Ionization
Iavarone, A. T., Jurchen, J. C., & Williams, E. R. (2001) · Analytical Chemistry · doi:10.1021/ac001251t · Cited by 229
MALDI-TOF MS: A Reliable Tool in the Real Life of the Clinical Microbiology Laboratory
Calderaro, A., & Chezzi, C. (2024) · Microorganisms · doi:10.3390/microorganisms12020322 · Cited by 188
“Spectra have been obtained for biopolymers including oligonucleotides and proteins, with the latter having molecular weights up to 130,000, with as yet no evidence of an upper limit [18].”
The Role of Dipeptidyl Peptidase IV in the Cleavage of Glucagon Family Peptides
Zhu, L., Tamvakopoulos, C., Xie, D., Dragovic, J., Shen, X., Fenyk-Melody, J. E., Schmidt, K., Bagchi, A., Griffin, P. R., Thornberry, N. A., et al. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m212355200 · Cited by 221
Beck, J. L., Colgrave, M. L., Ralph, S. F., & Sheil, M. M. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.1003 · Cited by 227
Valentine, S. J., Counterman, A. E., & Clemmer, D. E. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00079-3 · Cited by 219
The use of AC potentials in electrospraying and electrospinning processes
Kessick, R., Fenn, J., & Tepper, G. (2004) · Polymer · doi:10.1016/j.polymer.2004.02.056 · Cited by 224
Self-citationThurman, E. M., Ferrer, I., & Barceló, D. (2001) · Analytical Chemistry · doi:10.1021/ac010506f · Cited by 220
Database searching using mass spectrometry data
Yates, J. R. (1998) · ELECTROPHORESIS · doi:10.1002/elps.1150190604 · Cited by 234
Electrospray: Its potential and limitations as an ionization method for biomolecules
Mann, M. (1990) · Organic Mass Spectrometry · doi:10.1002/oms.1210251104 · Cited by 225
Self-citationWorsfold, P. J., Monbet, P., Tappin, A. D., Fitzsimons, M. F., Stiles, D. A., & McKelvie, I. D. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.016 · Cited by 218
Pramanik, B. N., Mirza, U. A., Ing, Y. H., Liu, Y., Bartner, P. L., Weber, P. C., & Bose, A. K. (2002) · Protein Science · doi:10.1110/ps.0213702 · Cited by 224
“…greatly expanded the role of mass spectrometry (MS) in molecular weight determination of intact proteins as well as their post-translationally modified variants, even with molecular masses exceeding 500 kDa (Fenn et al. 1989; Hillenkamp et al. 1991; Chait and Kent 1992; Mirza et al. 2000).”
BackgroundPhotodetachment photoelectron spectroscopy of multiply charged anions using electrospray ionization
Wang, L.-S., Ding, C.-F., Wang, X.-B., & Barlow, S. E. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149694 · Cited by 225
Lipid analysis and lipidomics by structurally selective ion mobility-mass spectrometry
Kliman, M., May, J. C., & McLean, J. A. (2011) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2011.05.016 · Cited by 218
“Additional post-acquisition data treatments, such as charge-state deconvolution [55], can be utilized for ESI-IM-MS data workup to help simplify the data analyses.”
Weakly Bound Clusters of Biological Interest
Desfrançois, C., Carles, S., & Schermann, J. P. (2000) · Chemical Reviews · doi:10.1021/cr990061j · Cited by 225
Arnold, R. J., & Reilly, J. P. (1999) · Analytical Biochemistry · doi:10.1006/abio.1998.3077 · Cited by 220
The diverse and expanding role of mass spectrometry in structural and molecular biology
Lössl, P., van de Waterbeemd, M., & Heck, A. J. (2016) · The EMBO Journal · doi:10.15252/embj.201694818 · Cited by 222
“Although peptide-centric MS is nowadays the most popular variant of biomolecular MS, the initial seminal work introducing ESI and MALDI focused largely on intact proteins with masses up to 130 kDa (Karas & Hillenkamp, 1988; Tanaka et al , 1988; Fenn et al , 1989).”
Mørtz, E., O'Connor, P. B., Roepstorff, P., Kelleher, N. L., Wood, T. D., McLafferty, F. W., & Mann, M. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.16.8264 · Cited by 220
Self-citationMass spectrometry in bioinorganic analytical chemistry
Łobiński, R., Schaumlöffel, D., & Szpunar, J. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20069 · Cited by 212
“Despite the fundamental role that electrospray (Fenn et al., 1989) and MALDI (Karas & Hillenkamp, 1988; Tanaka et al.”
BackgroundMultidimensional Separations-Based Shotgun Proteomics
Fournier, M. L., Gilmore, J. M., Martin-Brown, S. A., & Washburn, M. P. (2007) · Chemical Reviews · doi:10.1021/cr068279a · Cited by 214
von Helden, G., Wyttenbach, T., & Bowers, M. T. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04211-3 · Cited by 214
Peptide Radicals and Cation Radicals in the Gas Phase
Tureček, F., & Julian, R. R. (2013) · Chemical Reviews · doi:10.1021/cr400043s · Cited by 213
Hawkes, J. A., D'Andrilli, J., Agar, J. N., Barrow, M. P., Berg, S. M., Catalán, N., Chen, H., Chu, R. K., Cole, R. B., Dittmar, T., et al. (2020) · Limnology and Oceanography: Methods · doi:10.1002/lom3.10364 · Cited by 206
“In the vast majority of recent DOM research, HRMS has been coupled to electrospray ionization (ESI), as this ‘ soft ’ ionization technique allows intact molecular ions to enter the mass spectrometer without fragmentation (Fenn et al. 1989; Henry et al. 1989; Novotny et al. 2014).”
Comprehensive Overview of Bottom-Up Proteomics Using Mass Spectrometry
Jiang, Y., Rex, D. A. B., Schuster, D., Neely, B. A., Rosano, G. L., Volkmar, N., Momenzadeh, A., Peters-Clarke, T. M., Egbert, S. B., Kreimer, S., et al. (2024) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.3c00068 · Cited by 190
Micro- and nanoparticles via capillary flows
Barrero, A., & Loscertales, I. G. (2007) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.39.050905.110245 · Cited by 219
Electrospray Ionization Using Wooden Tips
Hu, B., So, P.-K., Chen, H., & Yao, Z.-P. (2011) · Analytical Chemistry · doi:10.1021/ac2017713 · Cited by 217
Applications of Mass Spectrometry to Lipids and Membranes
Harkewicz, R., & Dennis, E. A. (2011) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-060409-092612 · Cited by 210
“The development of electrospray ionization (ESI) in the late 1980s (36), for which John Fenn was awarded part of the 2002 Nobel Prize in Harkewicz and Dennis Page 3”
BackgroundManufacturing of recombinant therapeutic proteins in microbial systems
Graumann, K., & Premstaller, A. (2006) · Biotechnology Journal · doi:10.1002/biot.200500051 · Cited by 208
“The introduction of electrospray ionization [266] and matrixassisted laser desorption ionization [267, 268] enabled the ionization and analysis of intact recombinant proteins.”
MethodTahallah, N., Pinkse, M., Maier, C. S., & Heck, A. J. R. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.275 · Cited by 210
Blochet, J.-E., Chevalier, C., Forest, E., Pebay-Peyroula, E., Gautier, M.-F., Joudrier, P., Pézolet, M., & Marion, D. (1993) · FEBS Letters · doi:10.1016/0014-5793(93)80249-t · Cited by 217
Fernández, F. M., Cody, R. B., Green, M. D., Hampton, C. Y., McGready, R., Sengaloundeth, S., White, N. J., & Newton, P. N. (2006) · ChemMedChem · doi:10.1002/cmdc.200600041 · Cited by 215
Lipidomics era: Accomplishments and challenges
Bou Khalil, M., Hou, W., Zhou, H., Elisma, F., Swayne, L. A., Blanchard, A. P., Yao, Z., Bennett, S. A. L., & Figeys, D. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20294 · Cited by 204
“The principles and mechanisms of ESI for lipids have been well summarized in many review articles and books (Fenn et al., 1989; Duffin, Henion, & Shieh, 1991; Hsu, Bohrer, & Turk, 1998a; Hsu & Turk, 2003; Pulfer & Murphy, 2003; Isaac et al., 2007; Postle et al., 2007; Dass, 2007b).”
BackgroundPongratz, M., Schluga, P., Jakupec, M. A., Arion, V. B., Hartinger, C. G., Allmaier, G., & Keppler, B. K. (2004) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b309160k · Cited by 206
The effect of charge emission from electrified liquid cones
De La Mora, J. F. (1992) · Journal of Fluid Mechanics · doi:10.1017/s0022112092002829 · Cited by 212
Fragmentation pathways of polymer ions
Wesdemiotis, C., Solak, N., Polce, M. J., Dabney, D. E., Chaicharoen, K., & Katzenmeyer, B. C. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20282 · Cited by 207
Analysis of the structural heterogeneity of laminarin by electrospray-ionisation-mass spectrometry
Read, S. M., Currie, G., & Bacic, A. (1996) · Carbohydrate Research · doi:10.1016/0008-6215(95)00350-9 · Cited by 208
Fast Photochemical Oxidation of Protein Footprints Faster than Protein Unfolding
Gau, B. C., Sharp, J. S., Rempel, D. L., & Gross, M. L. (2009) · Analytical Chemistry · doi:10.1021/ac901054w · Cited by 210
Electrospray mass spectrometry for protein characterization
Mann, M., & Wilm, M. (1995) · Trends in Biochemical Sciences · doi:10.1016/s0968-0004(00)89019-2 · Cited by 214
Self-citationEmmett, M. R., White, F. M., Hendrickson, C. L., Shi, S. D. H., & Marshall, A. G. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00287-0 · Cited by 211
Generating Electrospray from Microchip Devices Using Electroosmotic Pumping
Ramsey, R. S., & Ramsey, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac971475k · Cited by 209
Mass spectrometry of natural products: current, emerging and future technologies
Bouslimani, A., Sanchez, L. M., Garg, N., & Dorrestein, P. C. (2014) · Natural Product Reports · doi:10.1039/c4np00044g · Cited by 200
Large-scale protein identification using mass spectrometry
Lin, D., Tabb, D. L., & Yates, J. R. (2003) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/s1570-9639(02)00546-0 · Cited by 210
Coaxial electrospray of microparticles and nanoparticles for biomedical applications
Zhang, L., Huang, J., Si, T., & Xu, R. X. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.58 · Cited by 205
Xu, Y.-F., Lu, W., & Rabinowitz, J. D. (2015) · Analytical Chemistry · doi:10.1021/ac504118y · Cited by 202
Mass Spectrometry, Review of the Basics: Ionization
Awad, H., Khamis, M. M., & El-Aneed, A. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2014.954046 · Cited by 176
“Various ionization techniques have been used with MS, including ESI (17, 18), APCI (19, 20), atmospheric pressure photo ionization (APPI) (21), and MALDI (22, 23).”
MethodHolčapek, M., Jirásko, R., & Lísa, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.02.049 · Cited by 205
Santos, L. S. (2008) · European Journal of Organic Chemistry · doi:10.1002/ejoc.200700723 · Cited by 207
Systems Biology in Immunology: A Computational Modeling Perspective
Germain, R. N., Meier-Schellersheim, M., Nita-Lazar, A., & Fraser, I. D. C. (2011) · Annual Review of Immunology · doi:10.1146/annurev-immunol-030409-101317 · Cited by 203
Mass Spectrometry-Based Techniques to Elucidate the Sugar Code
Grabarics, M., Lettow, M., Kirschbaum, C., Greis, K., Manz, C., & Pagel, K. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00380 · Cited by 198
Matrix-Enhanced Secondary Ion Mass Spectrometry: A Method for Molecular Analysis of Solid Surfaces
Wu, K. J., & Odom, R. W. (1996) · Analytical Chemistry · doi:10.1021/ac950717i · Cited by 205
The rod transducin alpha subunit amino terminus is heterogeneously fatty acylated.
Neubert, T. A., Johnson, R. S., Hurley, J. B., & Walsh, K. A. (1992) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)36955-8 · Cited by 208
Electrospray ionization mass spectrometry and ion mobility analysis of the 20S proteasome complex
Loo, J. A., Berhane, B., Kaddis, C. S., Wooding, K. M., Xie, Y., Kaufman, S. L., & Chernushevich, I. V. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.02.017 · Cited by 203
“Specifically, from the initial pioneering development of electrospray ionization (ESI) by 2002 Nobelist John Fenn [5], the application of ESI-MS for studying noncovalent complexes has utility in biology, biochemistry, and biomedical research [6–8].”
BackgroundJiang, D., Men, L., Wang, J., Zhang, Y., Chickenyen, S., Wang, Y., & Zhou, F. (2007) · Biochemistry · doi:10.1021/bi700508n · Cited by 202
“Formation of multiply charged species also decreases the mass-to-charge ratios, shifting molecular ions of large biomolecules to the mass range readily accessible by most mass analyzers (44).”
BackgroundHenderson, S. C., Valentine, S. J., Counterman, A. E., & Clemmer, D. E. (1999) · Analytical Chemistry · doi:10.1021/ac9809175 · Cited by 203
van Baar, B. L. M. (2000) · FEMS Microbiology Reviews · doi:10.1016/s0168-6445(99)00036-4 · Cited by 197
Sequential phosphorylation of rhodopsin at multiple sites
Ohguro, H., Palczewski, K., Ericsson, L. H., Walsh, K. A., & Johnson, R. S. (1993) · Biochemistry · doi:10.1021/bi00072a030 · Cited by 205
Iavarone, A. T., Jurchen, J. C., & Williams, E. R. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00169-0 · Cited by 199
MALDI-TOF MS analysis of plant proanthocyanidins
Monagas, M., Quintanilla-López, J. E., Gómez-Cordovés, C., Bartolomé, B., & Lebrón-Aguilar, R. (2010) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2009.03.035 · Cited by 201
Laskin, J., Laskin, A., Roach, P. J., Slysz, G. W., Anderson, G. A., Nizkorodov, S. A., Bones, D. L., & Nguyen, L. Q. (2010) · Analytical Chemistry · doi:10.1021/ac902801f · Cited by 194
Studying 18 MDa Virus Assemblies with Native Mass Spectrometry
Snijder, J., Rose, R. J., Veesler, D., Johnson, J. E., & Heck, A. J. R. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201210197 · Cited by 193
Probing Free Multiply Charged Anions Using Photodetachment Photoelectron Spectroscopy
Wang, L.-S., & Wang, X.-B. (2000) · The Journal of Physical Chemistry A · doi:10.1021/jp9940093 · Cited by 199
Niessen, W. M. A. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)01112-6 · Cited by 206
Multi-dimensional liquid phase based separations in proteomics
WANG, H., & HANASH, S. (2003) · Journal of Chromatography B · doi:10.1016/s1570-0232(02)00335-5 · Cited by 201
Trapping, detection and reaction of very large single molecular ions by mass spectrometry
Smith, R. D., Cheng, X., Brace, J. E., Hofstadler, S. A., & Anderson, G. A. (1994) · Nature · doi:10.1038/369137a0 · Cited by 200
Characterization of an Electrospray Ion Source as a Controlled-Current Electrolytic Cell
Van Berkel, G. J., & Zhou, F. (1995) · Analytical Chemistry · doi:10.1021/ac00113a028 · Cited by 197
Glavin, D. P., Dworkin, J. P., Aubrey, A., Botta, O., Doty, J. H., Martins, Z., & Bada, J. L. (2006) · Meteoritics & Planetary Science · doi:10.1111/j.1945-5100.2006.tb00493.x · Cited by 193
Characterization of proanthocyanidins from grape seeds
Gabetta, B., Fuzzati, N., Griffini, A., Lolla, E., Pace, R., Ruffilli, T., & Peterlongo, F. (2000) · Fitoterapia · doi:10.1016/s0367-326x(99)00161-6 · Cited by 192
Imaging mass spectrometry: fundamentals and applications to drug discovery
Rubakhin, S. S., Jurchen, J. C., Monroe, E. B., & Sweedler, J. V. (2005) · Drug Discovery Today · doi:10.1016/s1359-6446(05)03458-6 · Cited by 190
Electrospray‐ionization mass spectrometry of intact intrinsic membrane proteins
Whitelegge, J. P., Gundersen, C. B., & Faull, K. F. (1998) · Protein Science · doi:10.1002/pro.5560070619 · Cited by 196
Lipidomics at the Interface of Structure and Function in Systems Biology
Gross, R. W., & Han, X. (2011) · Chemistry & Biology · doi:10.1016/j.chembiol.2011.01.014 · Cited by 191
“Currently, the most commonly employed ionization method for lipidomics is ESI-MS which was developed by the late John Fenn (Fenn et al., 1989) in Nobel Prize winning work.”
Method2D gels still have a niche in proteomics
Rogowska-Wrzesinska, A., Le Bihan, M.-C., Thaysen-Andersen, M., & Roepstorff, P. (2013) · Journal of Proteomics · doi:10.1016/j.jprot.2013.01.010 · Cited by 190
Characterisation of the substituent distribution in starch and cellulose derivatives
Richardson, S., & Gorton, L. (2003) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.08.005 · Cited by 184
Eberlin, M. N. (2007) · European Journal of Mass Spectrometry · doi:10.1255/ejms.837 · Cited by 195
Proton Transfer Reactivity of Large Multiply Charged Ions
Williams, E. R. (1996) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199608)31:8<831::aid-jms392>3.0.co;2-7 · Cited by 195
High resolution mass spectrometry based techniques at the crossroads of metabolic pathways
Junot, C., Fenaille, F., Colsch, B., & Bécher, F. (2014) · Mass Spectrometry Reviews · doi:10.1002/mas.21401 · Cited by 177
“With ESI (Fenn et al., 1989), matrix-assisted laser desorption/ ionization (MALDI) source represents another major soft ionization technique widely used in mass spectrometry for the characterization of biomolecules (Karas & Hillenkamp, 1988; Tanaka et al.”
MethodXu, K., Liu, L., Saad, O. M., Baudys, J., Williams, L., Leipold, D., Shen, B., Raab, H., Junutula, J. R., Kim, A., et al. (2011) · Analytical Biochemistry · doi:10.1016/j.ab.2011.01.004 · Cited by 192
Generation by electrospray of monodisperse water droplets for targeted drug delivery by inhalation
Tang, K., & Gomez, A. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90212-7 · Cited by 192
The electrostatic spray emitted from an electrified conical meniscus
Gañán-Calvo, A. M., Lasheras, J. C., Dávila, J., & Barrero, A. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90205-4 · Cited by 193
Electrospray and tandem mass spectrometry in biochemistry
GRIFFITHS, W. J., JONSSON, A. P., LIU, S., RAI, D. K., & WANG, Y. (2001) · Biochemical Journal · doi:10.1042/bj3550545 · Cited by 187
Debaene, F., Bœuf, A., Wagner-Rousset, E., Colas, O., Ayoub, D., Corvaïa, N., Van Dorsselaer, A., Beck, A., & Cianférani, S. (2014) · Analytical Chemistry · doi:10.1021/ac502593n · Cited by 179
Matrix‐assisted laser‐desorption mass spectrometry using 355 nm radiation
Beavis, R. C., Chait, B. T., & Standing, K. G. (1989) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290031208 · Cited by 190
Neubauer, G., Gottschalk, A., Fabrizio, P., Séraphin, B., Lührmann, R., & Mann, M. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.2.385 · Cited by 193
Self-citationTop‐down MS, a powerful complement to the high capabilities of proteolysis proteomics
McLafferty, F. W., Breuker, K., Jin, M., Han, X., Infusini, G., Jiang, H., Kong, X., & Begley, T. P. (2007) · The FEBS Journal · doi:10.1111/j.1742-4658.2007.06147.x · Cited by 186
Neuroproteomics: understanding the molecular organization and complexity of the brain
Bayés, A., & Grant, S. G. N. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2701 · Cited by 186
Recent Developments in Ion Mobility Spectrometry
Borsdorf, H., Mayer, T., Zarejousheghani, M., & Eiceman, G. A. (2011) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2011.582658 · Cited by 188
“(194) in 1968 that culminated with mass spectrometry studies of Yamashita and Fenn (195) and finally for the analysis of biological macromolecules (196).”
BackgroundRecent progress in thin separators for upgraded lithium ion batteries
Zhong, S., Yuan, B., Guang, Z., Chen, D., Li, Q., Dong, L., Ji, Y., Dong, Y., Han, J., & He, W. (2021) · Energy Storage Materials · doi:10.1016/j.ensm.2021.07.028 · Cited by 191
Activation of large lons in FT‐ICR mass spectrometry
Laskin, J., & Futrell, J. H. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20012 · Cited by 190
Cohen, S. L., & Chait, B. T. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2072 · Cited by 190
Collisional damping interface for an electrospray ionization time-of-flight mass spectrometer
Krutchinsky, A. N., Chernushevich, I. V., Spicer, V. L., Ens, W., & Standing, K. G. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00027-0 · Cited by 187
Sakamoto, S., Fujita, M., Kim, K., & Yamaguchi, K. (2000) · Tetrahedron · doi:10.1016/s0040-4020(99)01092-3 · Cited by 187
Lee, S.-W., Berger, S. J., Martinović, S., Paša-Tolić, L., Anderson, G. A., Shen, Y., Zhao, R., & Smith, R. D. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.082119899 · Cited by 184
Universal scaling laws for the disintegration of electrified drops
Collins, R. T., Sambath, K., Harris, M. T., & Basaran, O. A. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1213708110 · Cited by 187
“In several applications including ESIMS, once charged daughter droplets are produced by EHD tipstreaming, each generation of droplets formed evaporate, reach the Rayleigh limit, and undergo coulombic explosions (12, 23).”
BackgroundMethodDe Novo Sequencing and Homology Searching
Ma, B., & Johnson, R. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.014902 · Cited by 183
“The revolutionary ionization methods of electrospray (13)”
Collisional activation of peptide ions in FT‐ICR mass spectrometry
Laskin, J., & Futrell, J. H. (2003) · Mass Spectrometry Reviews · doi:10.1002/mas.10041 · Cited by 186
Abián, J., Oosterkamp, A. J., & Gelpí, E. (1999) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199904)34:4<255::aid-jms752>3.0.co;2-7 · Cited by 189
Effects of Anions on the Positive Ion Electrospray Ionization Mass Spectra of Peptides and Proteins
Mirza, U. A., & Chait, B. T. (1994) · Analytical Chemistry · doi:10.1021/ac00090a017 · Cited by 188
Applications of electrospray mass spectrometry inorganometallic chemistry
Henderson, W., Nickleson, B. K., & McCaffrey, L. J. (1998) · Polyhedron · doi:10.1016/s0277-5387(98)00246-0 · Cited by 188
Metadata
- Authors
- Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M.
- Affiliations
- Yale University (US)
- Venue
- Science
- Published
- 1989-10-06
- Volume
- 246
- Issue
- 4926
- Pages
- 64-71
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2073292063
- Cited by
- 7,634
- References
- 32
- Citations by year
- 2026: 126 · 2025: 157 · 2024: 177 · 2023: 194 · 2022: 164 · 2021: 213 · 2020: 220 · 2019: 240 · 2018: 227 · 2017: 255 · 2016: 251 · 2015: 316 · 2014: 327 · 2013: 340 · 2012: 395
- FWCI
- 11.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- electrospray ionization, large biomolecules, multiply charged ions, biopolymers, oligonucleotides, proteins, soft ionization
- MeSH terms
- Ions, Molecular Weight, Proteins, Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.