The DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
In Vivo Mammalian Brain Imaging Using One- and Two-Photon Fluorescence Microendoscopy
Open accessAbstract
One of the major limitations in the current set of techniques available to neuroscientists is a dearth of methods for imaging individual cells deep within the brains of live animals. To overcome this limitation, we developed two forms of minimally invasive fluorescence microendoscopy and tested their abilities to image cells in vivo. Both one- and two-photon fluorescence microendoscopy are based on compound gradient refractive index (GRIN) lenses that are 350–1,000 μm in diameter and provide micron-scale resolution. One-photon microendoscopy allows full-frame images to be viewed by eye or with a camera, and is well suited to fast frame-rate imaging. Two-photon microendoscopy is a laser-scanning modality that provides optical sectioning deep within tissue. Using in vivo microendoscopy we acquired video-rate movies of thalamic and CA1 hippocampal red blood cell dynamics and still-frame images of CA1 neurons and dendrites in anesthetized rats and mice. Microendoscopy will help meet the growing demand for in vivo cellular imaging created by the rapid emergence of new synthetic and genetically encoded fluorophores that can be used to label specific brain areas or cell classes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Imaging Neuronal Subsets in Transgenic Mice Expressing Multiple Spectral Variants of GFP
Feng, G., Mellor, R. H., Bernstein, M., Keller-Peck, C., Nguyen, Q. T., Wallace, M., Nerbonne, J. M., Lichtman, J. W., & Sanes, J. R. (2000) · Neuron · doi:10.1016/s0896-6273(00)00084-2 · Cited by 3,042
Creating new fluorescent probes for cell biology
Zhang, J., Campbell, R. E., Ting, A. Y., & Tsien, R. Y. (2002) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm976 · Cited by 1,981
Long-term in vivo imaging of experience-dependent synaptic plasticity in adult cortex
Trachtenberg, J. T., Chen, B. E., Knott, G. W., Feng, G., Sanes, J. R., Welker, E., & Svoboda, K. (2002) · Nature · doi:10.1038/nature01273 · Cited by 1,927
In vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
In vivo two-photon calcium imaging of neuronal networks
Stosiek, C., Garaschuk, O., Holthoff, K., & Konnerth, A. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1232232100 · Cited by 1,312
Intrinsic brain activity triggers trigeminal meningeal afferents in a migraine model
Bolay, H., Reuter, U., Dunn, A. K., Huang, Z., Boas, D. A., & Moskowitz, M. A. (2002) · Nature Medicine · doi:10.1038/nm0202-136 · Cited by 1,214
Long-term dendritic spine stability in the adult cortex
Grutzendler, J., Kasthuri, N., & Gan, W.-B. (2002) · Nature · doi:10.1038/nature01276 · Cited by 1,198
Malonek, D., & Grinvald, A. (1996) · Science · doi:10.1126/science.272.5261.551 · Cited by 1,097
Development and Use of Fluorescent Protein Markers in Living Cells
Lippincott-Schwartz, J., & Patterson, G. H. (2003) · Science · doi:10.1126/science.1082520 · Cited by 992
Cited by
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
In vivo three-photon microscopy of subcortical structures within an intact mouse brain
Horton, N. G., Wang, K., Kobat, D., Clark, C. G., Wise, F. W., Schaffer, C. B., & Xu, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.336 · Cited by 1,505
Grienberger, C., & Konnerth, A. (2012) · Neuron · doi:10.1016/j.neuron.2012.02.011 · Cited by 1,354
Miniaturized integration of a fluorescence microscope
Ghosh, K. K., Burns, L. D., Cocker, E. D., Nimmerjahn, A., Ziv, Y., Gamal, A. E., & Schnitzer, M. J. (2011) · Nature Methods · doi:10.1038/nmeth.1694 · Cited by 1,120
Self-citationImaging large-scale neural activity with cellular resolution in awake, mobile mice
Dombeck, D. A., Khabbaz, A. N., Collman, F., Adelman, T. L., & Tank, D. W. (2007) · Neuron · doi:10.1016/j.neuron.2007.08.003 · Cited by 1,099
“For example, deeper brain structures can be accessed using GRIN lenses ( Jung et al., 2004; Levene et al., 2004).”
Principles of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
Next-Generation Optical Technologies for Illuminating Genetically Targeted Brain Circuits
Deisseroth, K., Feng, G., Majewska, A. K., Miesenböck, G., Ting, A., & Schnitzer, M. J. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.3863-06.2006 · Cited by 812
Self-citationFiber-optic fluorescence imaging
Flusberg, B. A., Cocker, E. D., Piyawattanametha, W., Jung, J. C., Cheung, E. L. M., & Schnitzer, M. J. (2005) · Nature Methods · doi:10.1038/nmeth820 · Cited by 732
Self-citationVSDI: a new era in functional imaging of cortical dynamics
Grinvald, A., & Hildesheim, R. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1536 · Cited by 618
Han, X., & Boyden, E. S. (2007) · PLoS ONE · doi:10.1371/journal.pone.0000299 · Cited by 601
Intracellular Coenzymes as Natural Biomarkers for Metabolic Activities and Mitochondrial Anomalies
Heikal, A. A. (2010) · Biomarkers in Medicine · doi:10.2217/bmm.10.1 · Cited by 458
FUKUMURA, D., DUDA, D. G., MUNN, L. L., & JAIN, R. K. (2010) · Microcirculation · doi:10.1111/j.1549-8719.2010.00029.x · Cited by 451
High-speed, miniaturized fluorescence microscopy in freely moving mice
Flusberg, B. A., Nimmerjahn, A., Cocker, E. D., Mukamel, E. A., Barretto, R. P. J., Ko, T. H., Burns, L. D., Jung, J. C., & Schnitzer, M. J. (2008) · Nature Methods · doi:10.1038/nmeth.1256 · Cited by 385
Self-citationThe Big and the Small: Challenges of Imaging the Brain’s Circuits
Lichtman, J. W., & Denk, W. (2011) · Science · doi:10.1126/science.1209168 · Cited by 370
Lima, S. Q., Hromádka, T., Znamenskiy, P., & Zador, A. M. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006099 · Cited by 360
Cellular Mechanisms of Conscious Processing
Aru, J., Suzuki, M., & Larkum, M. E. (2020) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2020.07.006 · Cited by 321
Imaging in vivo: watching the brain in action
Kerr, J. N. D., & Denk, W. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2338 · Cited by 346
High-resolution, lensless endoscope based on digital scanning through a multimode optical fiber
Papadopoulos, I. N., Farahi, S., Moser, C., & Psaltis, D. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.000260 · Cited by 345
Targeted patch-clamp recordings and single-cell electroporation of unlabeled neurons in vivo
Kitamura, K., Judkewitz, B., Kano, M., Denk, W., & Häusser, M. (2008) · Nature Methods · doi:10.1038/nmeth1150 · Cited by 341
Minimally invasive high-speed imaging of sarcomere contractile dynamics in mice and humans
Llewellyn, M. E., Barretto, R. P. J., Delp, S. L., & Schnitzer, M. J. (2008) · Nature · doi:10.1038/nature07104 · Cited by 337
Self-citationResendez, S. L., Jennings, J. H., Ung, R. L., Namboodiri, V. M. K., Zhou, Z. C., Otis, J. M., Nomura, H., McHenry, J. A., Kosyk, O., & Stuber, G. D. (2016) · Nature Protocols · doi:10.1038/nprot.2016.021 · Cited by 324
Optical Imaging Using Endogenous Contrast to Assess Metabolic State
Georgakoudi, I., & Quinn, K. P. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150108 · Cited by 316
Two-photon imaging of capillary blood flow in olfactory bulb glomeruli
Chaigneau, E., Oheim, M., Audinat, E., & Charpak, S. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2133652100 · Cited by 304
Cahalan, M. D., & Parker, I. (2008) · Annual Review of Immunology · doi:10.1146/annurev.immunol.24.021605.090620 · Cited by 302
Ultra-compact fiber-optic two-photon microscope for functional fluorescence imaging in vivo
Engelbrecht, C. J., Johnston, R. S., Seibel, E. J., & Helmchen, F. (2008) · Optics Express · doi:10.1364/oe.16.005556 · Cited by 279
Advances in Light Microscopy for Neuroscience
Wilt, B. A., Burns, L. D., Wei Ho, E. T., Ghosh, K. K., Mukamel, E. A., & Schnitzer, M. J. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135540 · Cited by 278
Self-citationTechnologies for imaging neural activity in large volumes
Ji, N., Freeman, J., & Smith, S. L. (2016) · Nature Neuroscience · doi:10.1038/nn.4358 · Cited by 278
In vivo fluorescence imaging with high-resolution microlenses
Barretto, R. P. J., Messerschmidt, B., & Schnitzer, M. J. (2009) · Nature Methods · doi:10.1038/nmeth.1339 · Cited by 274
Self-citationDynamic imaging of the immune system: progress, pitfalls and promise
Germain, R. N., Miller, M. J., Dustin, M. L., & Nussenzweig, M. C. (2006) · Nature Reviews Immunology · doi:10.1038/nri1884 · Cited by 274
In vivo brain imaging using a portable 39?gram two-photon fluorescence microendoscope
Flusberg, B. A., Jung, J. C., Cocker, E. D., Anderson, E. P., & Schnitzer, M. J. (2005) · Optics Letters · doi:10.1364/ol.30.002272 · Cited by 260
Self-citationCell-based reporters reveal in vivo dynamics of dopamine and norepinephrine release in murine cortex
Muller, A., Joseph, V., Slesinger, P. A., & Kleinfeld, D. (2014) · Nature Methods · doi:10.1038/nmeth.3151 · Cited by 139
Wang, S., Liu, J., Feng, G., Ng, L. G., & Liu, B. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808365 · Cited by 110
Luo, Z., Volkow, N. D., Heintz, N., Pan, Y., & Du, C. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.2369-11.2011 · Cited by 90
“Recent advances in microprobe techniques [e.g., the gradual refractive index lens (Jung et al., 2004; Levene et al., 2004) and micro-prisms (Chia and Levene, 2009, 2010)] now allow for dynamic [Ca 2 ]i measurements in subcortical brain regions in vivo.”
BackgroundMethodTools for Resolving Functional Activity and Connectivity within Intact Neural Circuits
Jennings, J. H., & Stuber, G. D. (2014) · Current Biology · doi:10.1016/j.cub.2013.11.042 · Cited by 54
Metadata
- Authors
- Jung, J. C., Mehta, A. D., Aksay, E., Stepnoski, R., & Schnitzer, M. J.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2004-11
- Volume
- 92
- Issue
- 5
- Pages
- 3121-3133
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2100061300
- Cited by
- 380
- References
- 67
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.