A Review on MR Image Intensity Inhomogeneity Correction
Open accessThe DOI matches its Crossref record; 84 of the 84 references it cites were found in a registry or an index.
Abstract
Intensity inhomogeneity (IIH) is often encountered in MR imaging, and a number of techniques have been devised to correct this artifact. This paper attempts to review some of the recent developments in the mathematical modeling of IIH field. Low‐frequency models are widely used, but they tend to corrupt the low‐frequency components of the tissue. Hypersurface models and statistical models can be adaptive to the image and generally more stable, but they are also generally more complex and consume more computer memory and CPU time. They are often formulated together with image segmentation within one framework and the overall performance is highly dependent on the segmentation process. Beside these three popular models, this paper also summarizes other techniques based on different principles. In addition, the issue of quantitative evaluation and comparative study are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stochastic relaxation, gibbs distributions, and the bayesian restoration of images.
Geman, S., & Geman, D. (1984) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1984.4767596 · Cited by 17,949 · cited 1×
“A useful tool for spatial modeling is the Markov random field (MRF), which is first employed by Geman and Geman [72] for image segmentation.”
MethodVoxel-Based Morphometry—The Methods
Ashburner, J., & Friston, K. J. (2000) · NeuroImage · doi:10.1006/nimg.2000.0582 · Cited by 8,676 · cited 1×
“In this way, the two different problems, IIH correction and image segmentation, are formulated in one framework and solved simultaneously.”
Fischl, B., Salat, D. H., Busa, E., Albert, M., Dieterich, M., Haselgrove, C., van der Kouwe, A., Killiany, R., Kennedy, D., Klaveness, S., et al. (2002) · Neuron · doi:10.1016/s0896-6273(02)00569-x · Cited by 8,610
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507 · cited 1×
“In addition, there even exist attempts to address these three processes, IIH correction, segmentation, and registration together [93, 94].”
Zhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982 · cited 1×
“A large category of surface fitting approaches search the parameters by fitting with respect to a set of tissue points encoding information about the IIH.”
BackgroundSpatial Interaction and the Statistical Analysis of Lattice Systems
Besag, J. (1974) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1974.tb00999.x · Cited by 6,067
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
Non-Uniform Random Variate Generation
Devroye, L. (1986) · Springer eBooks · doi:10.1007/978-1-4613-8643-8 · Cited by 4,041
Spatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C. D., Poline, J. ‐., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 4,028 · cited 1×
“Image registration has also been utilized to aid the IIH correction [89, 90].”
MethodRoemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Design and construction of a realistic digital brain phantom
Collins, D. L., Zijdenbos, A. P., Kollokian, V., Sled, J. G., Kabani, N. J., Holmes, C. J., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712135 · Cited by 1,822 · cited 4×
“A more comprehensive study was presented in [66], where six algorithms, n3 [74], hum [42], eq [43], bfc [78], spm (statistical parametric mapping)4 [52], and cma5 were compared against BrainWeb-simulated data as well as real volumes including repeated scans of the same subject, scans under different magnetic fields an…”
MethodInfluentialA modified fuzzy c-means algorithm for bias field estimation and segmentation of MRI data
Ahmed, M. N., Yamany, S. M., Mohamed, N., Farag, A. A., & Moriarty, T. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.996338 · Cited by 1,792
Adaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
Magnetic Resonance Image Tissue Classification Using a Partial Volume Model
Shattuck, D. W., Sandor-Leahy, S. R., Schaper, K. A., Rottenberg, D. A., & Leahy, R. M. (2001) · NeuroImage · doi:10.1006/nimg.2000.0730 · Cited by 950 · cited 2×
“A more comprehensive study was presented in [66], where six algorithms, n3 [74], hum [42], eq [43], bfc [78], spm (statistical parametric mapping)4 [52], and cma5 were compared against BrainWeb-simulated data as well as real volumes including repeated scans of the same subject, scans under different magnetic fields an…”
MethodMultimodal Image Coregistration and Partitioning—A Unified Framework
Ashburner, J., & Friston, K. (1997) · NeuroImage · doi:10.1006/nimg.1997.0290 · Cited by 927 · cited 1×
“Since the inhomogeneity field is slowly varying, it is natural to approximate the IIH by a parametric smooth functional [6, 48–58].”
BackgroundBrainSuite: An automated cortical surface identification tool
Shattuck, D. W., & Leahy, R. M. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00054-3 · Cited by 859
Brain development, gender and IQ in children: A volumetric imaging study
Reiss, A. L., Abrams, M. T., Singer, H. S., Ross, J. L., & Denckla, M. B. (1996) · Brain · doi:10.1093/brain/119.5.1763 · Cited by 844 · cited 1×
“In addition, the issue of quantitative evaluation and comparative study are discussed.”
BackgroundAdaptive fuzzy segmentation of magnetic resonance images
Pham, D. L., & Prince, J. L. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.802752 · Cited by 805 · cited 2×
“There are methods [84–88] which consider the IIH as model parameters formulated in a segmentation framework.”
MethodAutomated model-based bias field correction of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811268 · Cited by 583 · cited 1×
“When a statistical classifier, such as Gaussian classifier or random field modeling, is exploited [50, 53, 63], the process is similar to the parameter estimation in Section 4, where the parameters are associated with a probability distribution and can be estimated with common statistical estimation methods such as ma…”
MethodParametric estimate of intensity inhomogeneities applied to MRI
Styner, M., Brechbuhler, C., Szckely, G., & Gerig, G. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845174 · Cited by 527 · cited 1×
“For comparison, the IIH corrected images by a surface fitting technique [6] are given in Figure 1(b), from which the improvement in image quality is clearly visible.”
MethodMarkov Random Field Segmentation of Brain MR Images
Held, K., Kops, E. R., Krause, B. J., Wells, W. M., III, Kikinis, R., & Müller-Gärtner, H.-W. (1997) · Cited by 484
Pham, D. L., & Prince, J. L. (1999) · Pattern Recognition Letters · doi:10.1016/s0167-8655(98)00121-4 · Cited by 472
Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities
Sutton, B. P., Noll, D. C., & Fessler, J. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808360 · Cited by 397 · cited 1×
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
BackgroundInfluentialMarkov random field segmentation of brain MR images
Held, K., Kops, E. R., Krause, B. J., Wells, W. M., Kikinis, R., & Muller-Gartner, H.-W. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650883 · Cited by 381 · cited 1×
“[69] have employed the MRF to model IIH.”
MethodImaging of the active B1 field in vivo
Stollberger, R., & Wach, P. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350217 · Cited by 357 · cited 1×
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
BackgroundInfluentialEstimating the bias field of MR images
Guillemaud, R., & Brady, M. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.585758 · Cited by 329 · cited 4×
“The EM method made excessively large corrections to voxels that fall outside the classifier’s tissue model, as is consistent with that pointed out in [68].”
BackgroundMethodInfluentialAn adaptive spatial fuzzy clustering algorithm for 3-D MR image segmentation
Liew, A. W.-C., & Yan, H. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.816956 · Cited by 316 · cited 1×
“Liew and Yan [58] approximated the IIH as a stack of Bspline surfaces with continuity constraints across slices.”
BackgroundSegmentation of MR Brain Images into Cerebrospinal Fluid Spaces, White and Gray Matter
Lim, K. O., & Pfefferbaum, A. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198907000-00006 · Cited by 309 · cited 1×
“In addition, the issue of quantitative evaluation and comparative study are discussed.”
BackgroundScale-Based Fuzzy Connected Image Segmentation: Theory, Algorithms, and Validation
Saha, P. K., Udupa, J. K., & Odhner, D. (2000) · Computer Vision and Image Understanding · doi:10.1006/cviu.1999.0813 · Cited by 294
Correction of intensity variations in MR images for computer-aided tissue classification
Dawant, B. M., Zijdenbos, A. P., & Margolin, R. A. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.251128 · Cited by 291 · cited 4×
“[97] have compared three IIH correction methods, the expectation maximization (EM) [67], the white matter (WM) [48], and the N3 method [74] using simulated T1, T2, and PD weighted data.”
BackgroundMethodInfluentialA homogeneity correction method for magnetic resonance imaging with time-varying gradients
Noll, D. C., Meyer, C. H., Pauly, J. M., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108599 · Cited by 277 · cited 1×
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
BackgroundInfluentialSources of intensity nonuniformity in spin echo images at 1.5 T
Simmons, A., Tofts, P. S., Barker, G. J., & Arridge, S. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320117 · Cited by 277 · cited 1×
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
BackgroundInfluentialRetrospective correction of MR intensity inhomogeneity by information minimization
Likar, B., Viergever, M. A., & Pernus, F. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974934 · Cited by 267
Comparison of linear and circular polarization for magnetic resonance imaging
Glover, G. H., Hayes, C. E., Pelc, N. J., Edelstein, W. A., Mueller, O. M., Hart, H. R., Hardy, C. J., O'Donnell, M., & Barber, W. D. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90349-x · Cited by 265 · cited 1×
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
BackgroundInfluentialSegmentation of multiple sclerosis lesions in intensity corrected multispectral MRI
Johnston, B., Atkins, M. S., Mackiewich, B., & Anderson, M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491417 · Cited by 260 · cited 1×
“[29] have evaluated four IIH correction methods (a phantom method [17], two lowpass filtering methods [36, 39], and a surface fitting method with reference points selected from white matter [48]) in brain tumor segmentation.”
MethodJernigan, T. L. (1990) · Archives of Neurology · doi:10.1001/archneur.1990.00530010035015 · Cited by 257 · cited 1×
“In addition, the issue of quantitative evaluation and comparative study are discussed.”
BackgroundAn accurate and efficient Bayesian method for automatic segmentation of brain MRI
Marroquin, J. L., Vemuri, B. C., Botello, S., Calderon, E., & Fernandez-Bouzas, A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.803119 · Cited by 251
Intensity correction in surface-coil MR imaging
Axel, L., Costantini, J., & Listerud, J. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.148.2.418 · Cited by 240 · cited 1×
“In addition, the issue of quantitative evaluation and comparative study are discussed.”
BackgroundCorrection of off resonance‐related distortion in echo‐planar imaging using EPI‐based field maps
Reber, P. J., Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390223 · Cited by 223
Optimized homomorphic unsharp masking for MR grayscale inhomogeneity correction
Brinkmann, B. H., Manduca, A., & Robb, R. A. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700729 · Cited by 213 · cited 3×
“Also in [42], the impact of filter width on IIH correction was investigated and it was found that these methods should be used with care to avoid intensity distortion and artificial artifacts in the corrected images.”
BackgroundMethodVolume imaging with MR phased arrays
Hayes, C. E., Hattes, N., & Roemer, P. B. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180206 · Cited by 178 · cited 1×
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
BackgroundInfluentialRetrospective correction of intensity inhomogeneities in MRI
Meyer, C. R., Bland, P. H., & Pipe, J. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.370400 · Cited by 176 · cited 1×
“[49] employed the LCJ method [60] to preliminarily segment the image and then fit a smooth functional over the segmented image.”
MethodArnold, J. B., Liow, J.-S., Schaper, K. A., Stern, J. J., Sled, J. G., Shattuck, D. W., Worth, A. J., Cohen, M. S., Leahy, R. M., Mazziotta, J. C., et al. (2001) · NeuroImage · doi:10.1006/nimg.2001.0756 · Cited by 172 · cited 3×
“It should be pointed out that the spm method used in [66] is the SPM99 version, which has been updated to version SPM2 in 2003 with substantial improvement in theoretical modeling”
BackgroundMethodInhomogeneity correction using an estimated linear field map
Irarrazabal, P., Meyer, C. H., Nishimura, D. G., & Macovski, A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350221 · Cited by 170 · cited 1×
“In addition, the issue of quantitative evaluation and comparative study are discussed.”
BackgroundRapid and effective correction of RF inhomogeneity for high field magnetic resonance imaging
Cohen, M. S., DuBois, R. M., & Zeineh, M. M. (2000) · Human Brain Mapping · doi:10.1002/1097-0193(200008)10:4<204::aid-hbm60>3.0.co;2-2 · Cited by 164 · cited 2×
“In [47], an improvement of a lowpass filtering method [43] was presented.”
MethodCorrection of intensity nonuniformity in MR images of any orientation
Wicks, D., Barker, G. J., & Tofts, P. S. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90023-7 · Cited by 155 · cited 1×
“[29] have evaluated four IIH correction methods (a phantom method [17], two lowpass filtering methods [36, 39], and a surface fitting method with reference points selected from white matter [48]) in brain tumor segmentation.”
MethodEntropy minimization for automatic correction of intensity nonuniformity
Mangin, J. (2002) · IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA) · doi:10.1109/mmbia.2000.852374 · Cited by 149 · cited 2×
“Mangin [55] constrained the solution to minimize the distance between the mean values of the restored and the original image.”
Retrospective shading correction based on entropy minimization
likar, Maintz, Viergever, M. A., & Pernuš (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00669.x · Cited by 145 · cited 1×
“In this way, the two different problems, IIH correction and image segmentation, are formulated in one framework and solved simultaneously.”
Polynomial modeling and reduction of RF body coil spatial inhomogeneity in MRI
Tincher, M., Meyer, C. R., Gupta, R., & Williams, D. M. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.232267 · Cited by 145 · cited 1×
“One can obtain the IIH map from measurement in vivo [8–15], typically of a uniform phantom, [16–20], which often requires extra measurement (and increases the scanning time) or needs additional hardware which may not be readily available in some clinical departments.”
BackgroundAlecci, M., Collins, C. M., Smith, M. B. H., & Jezzard, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1201 · Cited by 144 · cited 1×
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
BackgroundInfluentialLocal histogram correction of MRI spatially dependent image pixel intensity nonuniformity
Decarli, C., Murphy, D. G. M., Teichberg, D., Campbell, G., & Sobering, G. S. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060316 · Cited by 138 · cited 2×
“When GM and WM are combined as one class and the local statistic is estimated from a sample in a local region as done in [76, 77], the method can be regarded as a generalized white matter method by Dawant et al.”
MethodWald, L. L., Carvajal, L. E., Moyher, S. E., Nelson, S. J., Grant, P. E., Barkovich, A. J., & Vigneron, D. B. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340321 · Cited by 132 · cited 1×
“In addition, the issue of quantitative evaluation and comparative study are discussed.”
BackgroundCompensation for surface coil sensitivity variation in magnetic resonance imaging
Narayana, P. A., Brey, W. W., Kulkarni, M. V., & Sievenpiper, C. (1988) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(88)90401-8 · Cited by 131 · cited 1×
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
BackgroundInfluentialCollins, C. M., Yang, Q., Wang, J. H., Zhang, X., Liu, H., Michaeli, S., Zhu, X. H., Adriany, G., Vaughan, J. T., Anderson, P., et al. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10153 · Cited by 131
Image non-uniformity in magnetic resonance imaging: its magnitude and methods for its correction
Condon, B. R., Patterson, J. C., Wyper, D., Jenkins, A., & Hadley, D. M. (1987) · British Journal of Radiology · doi:10.1259/0007-1285-60-709-83 · Cited by 120
Measurement and correction of transmitter and receiver induced nonuniformities in vivo
Wang, J., Qiu, M., Yang, Q., Smith, M. B. H., & Constable, R. T. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20354 · Cited by 118 · cited 1×
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
BackgroundInfluentialInterplay between intensity standardization and inhomogeneity correction in MR image processing
Madabhushi, A., & Udupa, J. K. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.843256 · Cited by 115 · cited 1×
“Madabhushi and Udupa [95] investigated the interplay between IIH correction and intensity standardization, and concluded that the better sequence is IIH correction followed by intensity standardization.”
BackgroundThompson, N., & Campling, J. (1996) · doi:10.1007/978-1-349-13737-4_19 · Cited by 103
A fast model independent method for automatic correction of intensity nonuniformity in MRI data
Vokurka, E. A., Thacker, N. A., & Jackson, A. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199910)10:4<550::aid-jmri8>3.0.co;2-q · Cited by 101 · cited 1×
“However, it is very similar to that in [81].”
BackgroundPhase and sensitivity of receiver coils in magnetic resonance imaging
McVeigh, E. R., Bronskill, M. J., & Henkelman, R. M. (1986) · Medical Physics · doi:10.1118/1.595967 · Cited by 98 · cited 1×
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
InfluentialComparative evaluation of retrospective shading correction methods
Tomaževič, D., Likar, B., & Pernuš, F. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01079.x · Cited by 95 · cited 1×
“An investigation of applying IIH correction methods to deal with the shading problem in microscopic images has been carried out in [31].”
MethodCorrection for intensity falloff in surface coil magnetic resonance imaging
Brey, W. W., & Narayana, P. A. (1988) · Medical Physics · doi:10.1118/1.596255 · Cited by 94 · cited 1×
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
BackgroundInfluentialIntensity correction of phased‐array surface coil images
Murakami, J. W., Hayes, C. E., & Weinberger, E. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350419 · Cited by 93 · cited 1×
“In addition, the issue of quantitative evaluation and comparative study are discussed.”
BackgroundSurface coil MR imaging of the human brain with an analytic reception profile correction
Moyher, S. E., Vigneron, D. B., & Nelson, S. J. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050204 · Cited by 92 · cited 1×
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
BackgroundInfluentialCorrection forB1 andB0 variations in quantitativeT2 measurements using MRI
Sled, J. G., & Pike, G. B. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200004)43:4<589::aid-mrm14>3.0.co;2-2 · Cited by 92
Lin, F., Chen, Y., Belliveau, J. W., & Wald, L. L. (2003) · Human Brain Mapping · doi:10.1002/hbm.10109 · Cited by 89
Gispert, J. D., Reig, S., Pascau, J., Vaquero, J. J., Garcia-Barreno, P., & Desco, M. (2004) · Human Brain Mapping · doi:10.1002/hbm.20013 · Cited by 84 · cited 1×
“This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.”
MethodAn algorithm for compensation of surface-coil images for sensitivity of the surface coil
Haselgrove, J. C., & Prammer, M. G. (1986) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(86)90024-x · Cited by 76 · cited 1×
“In addition, the issue of quantitative evaluation and comparative study are discussed.”
BackgroundPrima, S., Ayache, N., Barrick, T., & Roberts, N. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_97 · Cited by 68 · cited 1×
“When a statistical classifier, such as Gaussian classifier or random field modeling, is exploited [50, 53, 63], the process is similar to the parameter estimation in Section 4, where the parameters are associated with a probability distribution and can be estimated with common statistical estimation methods such as ma…”
MethodMRI intensity inhomogeneity correction by combining intensity and spatial information
Vovk, U., Pernu, F., & Likar, B. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/17/020 · Cited by 65 · cited 1×
“[82, 83] proposed to use the probability distribution of image features for IIH correction, where the image feature includes the intensity and the second spatial derivative of the image.”
MethodGeneralized scale: Theory, algorithms, and application to image inhomogeneity correction
Madabhushi, A., Udupa, J. K., & Souza, A. (2005) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2005.07.010 · Cited by 65
Narayana, P. A., & Borthakur, A. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330312 · Cited by 64
A multi‐scale method for automatic correction of intensity non‐uniformity in MR images
Han, C., Hatsukami, T. S., & Yuan, C. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1062 · Cited by 64 · cited 2×
“Recently, lowpass filtering methods have been extended using the wavelet transform [45, 46] and were shown to be effective in removing IIH in images acquired by surface coils and phase array coils.”
BackgroundMethodStudholme, C., Cardenas, V. A., Song, E., Ezekiel, F., Maudsley, A. A., & Weiner, M. W. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.820029 · Cited by 60 · cited 2×
“In [90], the patient data was registered against a tissue reference template, which allows to estimate the IIH map by direct comparison between two images.”
Correction of intensity nonuniformity in spin-echo T 1 -weighted images
Collewet, G., Davenel, A., Toussaint, C. A., & Akoka, S. (2002) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00502-7 · Cited by 58 · cited 1×
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
BackgroundInfluentialReview and evaluation of MRI nonuniformity corrections for brain tumor response measurements
Velthuizen, R. P., Heine, J., Cantor, A. B., Lin, H., Fletcher, L. M., & Clarke, L. P. (1998) · Medical Physics · doi:10.1118/1.598357 · Cited by 57 · cited 3×
“Although it turned out no improvement in tumor assessment after the IIH correction [29], it does not mean that IIH correction is not an obstacle to automatic medical image processing in general, since the tumor segmentation is characterized by the localization of the tumor region as well as the intensity contrast with…”
BackgroundMethodA comparison of retrospective intensity non-uniformity correction methods for MRI
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1997) · Lecture notes in computer science · doi:10.1007/3-540-63046-5_43 · Cited by 48 · cited 1×
“[97] have compared three IIH correction methods, the expectation maximization (EM) [67], the white matter (WM) [48], and the N3 method [74] using simulated T1, T2, and PD weighted data.”
MethodA Unified Variational Approach to Denoising and Bias Correction in MR
Fan, A. C., Wells, W. M., Fisher, J. S., Çetin, M., Haker, S. J., Mulkern, R. V., Tempany, C. M., & Willsky, A. S. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-45087-0_13 · Cited by 45 · cited 1×
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
BackgroundInfluentialLai, S., & Fang, M. (1999) · Medical Image Analysis · doi:10.1016/s1361-8415(99)80033-4 · Cited by 44
Post‐acquisition correction of MR inhomogeneities
Lee, S., & Vannier, M. W. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360215 · Cited by 42 · cited 2×
“When GM and WM are combined as one class and the local statistic is estimated from a sample in a local region as done in [76, 77], the method can be regarded as a generalized white matter method by Dawant et al.”
BackgroundMethodCorrection of bias field in MR images using singularity function analysis
Luo, J., Zhu, Y., Clarysse, P., & Magnin, I. E. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.852066 · Cited by 38 · cited 1×
“[44] presented a technique to recover lowfrequency components which correspond to anatomic structure and are lost during the lowpass filtering.”
MethodSources of T1 variance in normal human white matter
Harvey, I., Tofts, P. S., Morris, J. K., Wicks, D., & Ron, M. A. (1991) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(91)90096-5 · Cited by 21 · cited 1×
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 49515, Pages 1–11 DOI 10.1155/IJBI/2006/49515”
BackgroundInfluentialCorrecting Nonuniformities in MRI Intensities Using Entropy Minimization Based on an Elastic Model
Bansal, R., Staib, L. H., & Peterson, B. S. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-30135-6_10 · Cited by 17 · cited 1×
“[92] modelled the IIH field as a thin plate deforming elastically under a body force:”
BackgroundGeneralized scale: theory, algorithms, and application to image inhomogeneity correction
Madabhushi, A., Udupa, J. K., & Souza, A. M. C. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.535696 · Cited by 6 · cited 1×
“In [61, 62], segmentation that utilizes local scale as homogeneous criteria has been presented and applied to IIH correction.”
Method
Cited by
N4ITK: Improved N3 Bias Correction
Tustison, N. J., Avants, B. B., Cook, P. A., Zheng, Y., Egan, A., Yushkevich, P. A., & Gee, J. C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2046908 · Cited by 6,073
Minimization of Region-Scalable Fitting Energy for Image Segmentation
Li, C., Kao, C.-Y., Gore, J. C., & Ding, Z. (2008) · IEEE Transactions on Image Processing · doi:10.1109/tip.2008.2002304 · Cited by 1,721
State of the art survey on MRI brain tumor segmentation
Gordillo, N., Montseny, E., & Sobrevilla, P. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2013.05.002 · Cited by 697
Lesion identification using unified segmentation-normalisation models and fuzzy clustering
Seghier, M. L., Ramlackhansingh, A., Crinion, J., Leff, A. P., & Price, C. J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.03.028 · Cited by 317
What are normal relaxation times of tissues at 3 T?
Bojorquez, J. Z., Bricq, S., Acquitter, C., Brunotte, F., Walker, P. M., & Lalande, A. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.08.021 · Cited by 286
Metadata
- Authors
- Hou, Z.
- Venue
- International Journal of Biomedical Imaging
- Publisher
- Wiley
- Published
- 2006-01
- Volume
- 2006
- Issue
- 1
- Pages
- 49515-49515
- ISSN
- 1687-4188 (ISSN-L)
- 1687-4196
- OpenAlex
- W2008101963
- Cited by
- 200
- References
- 84
- FWCI
- 10.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.