Functional Living Trileaflet Heart Valves Grown In Vitro
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Previous tissue engineering approaches to create heart valves have been limited by the structural immaturity and mechanical properties of the valve constructs. This study used an in vitro pulse duplicator system to provide a biomimetic environment during tissue formation to yield more mature implantable heart valves derived from autologous tissue. METHODS AND RESULTS: Trileaflet heart valves were fabricated from novel bioabsorbable polymers and sequentially seeded with autologous ovine myofibroblasts and endothelial cells. The constructs were grown for 14 days in a pulse duplicator in vitro system under gradually increasing flow and pressure conditions. By use of cardiopulmonary bypass, the native pulmonary leaflets were resected, and the valve constructs were implanted into 6 lambs (weight 19+/-2.8 kg). All animals had uneventful postoperative courses, and the valves were explanted at 1 day and at 4, 6, 8, 16, and 20 weeks. Echocardiography demonstrated mobile functioning leaflets without stenosis, thrombus, or aneurysm up to 20 weeks. Histology (16 and 20 weeks) showed uniform layered cuspal tissue with endothelium. Environmental scanning electron microscopy revealed a confluent smooth valvular surface. Mechanical properties were comparable to those of native tissue at 20 weeks. Complete degradation of the polymers occurred by 8 weeks. Extracellular matrix content (collagen, glycosaminoglycans, and elastin) and DNA content increased to levels of native tissue and higher at 20 weeks. CONCLUSIONS: This study demonstrates in vitro generation of implantable complete living heart valves based on a biomimetic flow culture system. These autologous tissue-engineered valves functioned up to 5 months and resembled normal heart valves in microstructure, mechanical properties, and extracellular matrix formation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
Two Improved and Simplified Methods for the Spectrophotometric Determination of Hydroxyproline.
Bergman, I., & Loxley, R. (1963) · Analytical Chemistry · doi:10.1021/ac60205a053 · Cited by 1,525
Vacanti, J. P., & Langer, R. (1999) · The Lancet · doi:10.1016/s0140-6736(99)90247-7 · Cited by 1,323
Self-citationVongpatanasin, W., Hillis, L. D., & Lange, R. A. (1996) · New England Journal of Medicine · doi:10.1056/nejm199608083350607 · Cited by 811
Tissue heart valves: Current challenges and future research perspectives
Schoen, F. J., & Levy, R. J. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19991215)47:4<439::aid-jbm1>3.0.co;2-o · Cited by 498
Self-citationTwelve-Year Comparison of a Bjork–Shiley Mechanical Heart Valve with Porcine Bioprostheses
Bloomfield, P., Wheatley, D. J., Prescott, R. J., & Miller, H. C. (1991) · New England Journal of Medicine · doi:10.1056/nejm199102283240901 · Cited by 428
Preparation of Genomic DNA from Mammalian Tissue
Strauss, W. M. (1998) · Current Protocols in Molecular Biology · doi:10.1002/0471142727.mb0202s42 · Cited by 302
Tissue-engineered valved conduits in the pulmonary circulation
Stock, U. A., Nagashima, M., Khalil, P. N., Nollert, G. D., Herdena, T., Sperling, J. S., Moran, A., Lien, J., Martin, D. P., Schoen, F. J., et al. (2000) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(00)70008-0 · Cited by 251
Self-citationTissue-engineered heart valves. Autologous valve leaflet replacement study in a lamb model.
Shinoka, T., Ma, P. X., Shum‐Tim, D., Breuer, C. K., Cusick, R. A., Zünd, G., Langer, R., Vacanti, J. P., & Mayer, J. E. (1996) · PubMed · Cited by 246
Self-citationSchöen, F. J. (1997) · PubMed · Cited by 176
Cited by
The Emerging Role of Valve Interstitial Cell Phenotypes in Regulating Heart Valve Pathobiology
Liu, A. C., Joag, V. R., & Gotlieb, A. I. (2007) · The American Journal of Pathology · doi:10.2353/ajpath.2007.070251 · Cited by 632
Mikos, A. G., Herring, S. W., Ochareon, P., Elisseeff, J., Lu, H. H., Kandel, R., Schoen, F. J., Toner, M., Mooney, D., Atala, A., et al. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.3307 · Cited by 598
Self-citationElastomeric biomaterials for tissue engineering
Chen, Q., Liang, S., & Thouas, G. A. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.05.003 · Cited by 564
Atala, A., Kasper, F. K., & Mikos, A. G. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004890 · Cited by 544
Medical applications of poly-4-hydroxybutyrate: A strong flexible absorbable biomaterial
Martin, D. P., & Williams, S. F. (2003) · Biochemical Engineering Journal · doi:10.1016/s1369-703x(03)00040-8 · Cited by 510
Self-citationIn vivo vasculogenic potential of human blood-derived endothelial progenitor cells
Melero-Martin, J. M., Khan, Z. A., Picard, A., Wu, X., Paruchuri, S., & Bischoff, J. (2007) · Blood · doi:10.1182/blood-2006-12-062471 · Cited by 501
Duan, B., Kapetanovic, E., Hockaday, L. A., & Butcher, J. T. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.12.005 · Cited by 436
Schoen, F. J. (2008) · Circulation · doi:10.1161/circulationaha.108.805911 · Cited by 421
Tissue engineering: a 21st century solution to surgical reconstruction
Fuchs, J. R., Nasseri, B. A., & Vacanti, J. P. (2001) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(01)02820-x · Cited by 376
Self-citationThree-Dimensional BioAssembly Tool for Generating Viable Tissue-Engineered Constructs
Smith, C. M., Stone, A. L., Parkhill, R. L., Stewart, R. L., Simpkins, M. W., Kachurin, A. M., Warren, W. L., & Williams, S. K. (2004) · Tissue Engineering · doi:10.1089/1076327042500274 · Cited by 373
Udayakumar, G. P., Muthusamy, S., Selvaganesh, B., Sivarajasekar, N., Rambabu, K., Banat, F., Sivamani, S., Sivakumar, N., Hosseini-Bandegharaei, A., & Show, P. L. (2021) · Journal of Environmental Chemical Engineering · doi:10.1016/j.jece.2021.105322 · Cited by 347
Heart Valve Tissue Engineering: Concepts, Approaches, Progress, and Challenges
Mendelson, K., & Schoen, F. J. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9163-z · Cited by 328
Self-citationLiao, J., Joyce, E. M., & Sacks, M. S. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.007 · Cited by 304
From Stem Cells to Viable Autologous Semilunar Heart Valve
Sutherland, F. W. H., Perry, T. E., Yu, Y., Sherwood, M. C., Rabkin, E., Masuda, Y., Garcia, G. A., McLellan, D. L., Engelmayr, G. C., Sacks, M. S., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.498378 · Cited by 297
Self-citationButcher, J. T., Penrod, A. M., García, A. J., & Nerem, R. M. (2004) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000130462.50769.5a · Cited by 295
FLUID MECHANICS OF ARTIFICIAL HEART VALVES
Dasi, L. P., Simon, H. A., Sucosky, P., & Yoganathan, A. P. (2009) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2008.05099.x · Cited by 286
Biomechanical properties of native and tissue engineered heart valve constructs
Hasan, A., Ragaert, K., Swieszkowski, W., Selimović, Š., Paul, A., Camci-Unal, G., Mofrad, M. R. K., & Khademhosseini, A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.09.023 · Cited by 279
Kluin, J., Talacua, H., Smits, A. I. P. M., Emmert, M. Y., Brugmans, M. C. P., Fioretta, E. S., Dijkman, P. E., Söntjens, S. H. M., Duijvelshoff, R., Dekker, S., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.02.007 · Cited by 268
Self-citationNext-generation tissue-engineered heart valves with repair, remodelling and regeneration capacity
Fioretta, E. S., Motta, S. E., Lintas, V., Loerakker, S., Parker, K. K., Baaijens, F. P. T., Falk, V., Hoerstrup, S. P., & Emmert, M. Y. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0422-8 · Cited by 262
Self-citationSubstrates for cardiovascular tissue engineering
Bouten, C. V. C., Dankers, P. Y. W., Driessen-Mol, A., Pedron, S., Brizard, A. M. A., & Baaijens, F. P. T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.007 · Cited by 261
Fibrin as a cell carrier in cardiovascular tissue engineering applications
Mol, A., van Lieshout, M. I., Dam-de Veen, C. G., Neuenschwander, S., Hoerstrup, S. P., Baaijens, F. P. T., & Bouten, C. V. C. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.08.007 · Cited by 257
Self-citationBioengineering Challenges for Heart Valve Tissue Engineering
Sacks, M. S., Schoen, F. J., & Mayer, J. E. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124903 · Cited by 256
Self-citationCrosslinked hyaluronan scaffolds as a biologically active carrier for valvular interstitial cells
Masters, K. S., Shah, D. N., Leinwand, L. A., & Anseth, K. S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.018 · Cited by 256
Valappil, S. P., Misra, S. K., Boccaccini, A. R., & Roy, I. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.6.853 · Cited by 242
Introductory biomechanics: from cells to organisms
(2007) · Choice Reviews Online · doi:10.5860/choice.45-1476 · Cited by 241
Poly(3-hydroxyalkanoate)s: Diversification and biomedical applications
Hazer, D. B., Kılıçay, E., & Hazer, B. (2012) · Materials Science and Engineering: C · doi:10.1016/j.msec.2012.01.021 · Cited by 240
Tissue Engineering of Functional Trileaflet Heart Valves From Human Marrow Stromal Cells
Hoerstrup, S. P., Kadner, A., Melnitchouk, S., Trojan, A., Eid, K., Tracy, J., Sodian, R., Visjager, J. F., Kolb, S. A., Grunenfelder, J., et al. (2002) · Circulation · doi:10.1161/01.cir.0000032872.55215.05 · Cited by 240
Self-citationPolyester elastomers for soft tissue engineering
Ye, H., Zhang, K., Kai, D., Li, Z., & Loh, X. J. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00161h · Cited by 238
Prosthetic heart valves: Catering for the few
Zilla, P., Brink, J., Human, P., & Bezuidenhout, D. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.09.033 · Cited by 236
“Resorption of the porous leaflet scaffold initially led to overshooting fibrosis [182,183] but fine-tuning of the resorption process through the use of poly-glycolic-acid (PGA)/poly-4-hydroxybutyrate (P4HB) instead of polylactic acid (PLA) co-polymers led to living heart valves with a tri-layered structure and many fe…”
BackgroundResultInsights Into Degenerative Aortic Valve Disease
Goldbarg, S. H., Elmariah, S., Miller, M. A., & Fuster, V. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.06.024 · Cited by 233
Wu, X., Rabkin-Aikawa, E., Guleserian, K. J., Perry, T. E., Masuda, Y., Sutherland, F. W. H., Schoen, F. J., Mayer, J. E., & Bischoff, J. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01232.2003 · Cited by 231
Self-citationMedical Application of Microbial Biopolyesters Polyhydroxyalkanoates
Wu, Q., Wang, Y., & Chen, G.-Q. (2009) · Artificial Cells, Blood Substitutes, and Biotechnology · doi:10.1080/10731190802664429 · Cited by 227
Butcher, J. T., & Nerem, R. M. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.905 · Cited by 226
“The persistent transvalvular gradients and increased leaflet stiffness re-ported by this group 11 suggests that some phenotypic dif-912 ferences between the cells in these tissues and native valves may remain.”
Mol, A., Driessen, N. J. B., Rutten, M. C. M., Hoerstrup, S. P., Bouten, C. V. C., & Baaijens, F. P. T. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8025-4 · Cited by 225
Self-citationMinimally-Invasive Implantation of Living Tissue Engineered Heart Valves
Schmidt, D., Dijkman, P. E., Driessen-Mol, A., Stenger, R., Mariani, C., Puolakka, A., Rissanen, M., Deichmann, T., Odermatt, B., Weber, B., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.04.024 · Cited by 221
“Aiming at an autologous approach, vascular cells a ere utilized as they have proven to be successful for heart alve tissue engineering (8,13).”
BackgroundResultSelf-citationBiologically Inspired Scaffolds for Heart Valve Tissue Engineering via Melt Electrowriting
Saidy, N. T., Wolf, F., Bas, O., Keijdener, H., Hutmacher, D. W., Mela, P., & De‐Juan‐Pardo, E. M. (2019) · Small · doi:10.1002/smll.201900873 · Cited by 215
Biodegradable polyester elastomers in tissue engineering
Webb, A. R., Yang, J., & Ameer, G. A. (2004) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.4.6.801 · Cited by 208
“Hoerstrup and co-workers used P4HB that had been solvent coated onto non-woven PGA meshes to increase the degradation rate of the scaffold and eliminate the inflammatory response caused by residual polymer [42,43].”
BackgroundMethodApplication of Stereolithography for Scaffold Fabrication for Tissue Engineered Heart Valves
Sodian, R., Loebe, M., Hein, A., Martin, D. P., Hoerstrup, S. P., Potapov, E. V., Hausmann, H., Lueth, T., & Hetzer, R. (2002) · ASAIO Journal · doi:10.1097/00002480-200201000-00004 · Cited by 206
Self-citationMicrobial Polyhydroxyalkanoates and Nonnatural Polyesters
Choi, S. Y., Cho, I. J., Lee, Y., Kim, Y., Kim, K., & Lee, S. Y. (2020) · Advanced Materials · doi:10.1002/adma.201907138 · Cited by 200
Cardiovascular tissue engineering
Rabkin, E., & Schoen, F. J. (2002) · Cardiovascular Pathology · doi:10.1016/s1054-8807(02)00130-8 · Cited by 200
Self-citationBalguid, A., Rubbens, M. P., Mol, A., Bank, R. A., Bogers, A. J. J. C., van Kats, J. P., de Mol, B. A. J. M., Baaijens, F. P. T., & Bouten, C. V. C. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0279 · Cited by 197
Balguid, A., Mol, A., van Marion, M. H., Bank, R. A., Bouten, C. V. C., & Baaijens, F. P. T. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2007.0294 · Cited by 194
“11,12 Both scaffold materials are approved by the Food and Drug Administration.”
Engelmayr, G. C., Hildebrand, D. K., Sutherland, F. W. H., Mayer, J. E., & Sacks, M. S. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00051-6 · Cited by 193
Self-citationHow to Make a Heart Valve: From Embryonic Development to Bioengineering of Living Valve Substitutes
MacGrogan, D., Luxan, G., Driessen-Mol, A., Bouten, C., Baaijens, F., & de la Pompa, J. L. (2014) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a013912 · Cited by 189
“The porous starter matrix is shaped like a heart valve and supports the formation of neotissue (Hoerstrup et al. 2000).”
Hoerstrup, S. P., Cummings MRCS, I., Lachat, M., Schoen, F. J., Jenni, R., Leschka, S., Neuenschwander, S., Schmidt, D., Mol, A., Günter, C., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.001172 · Cited by 186
Self-citationAdvances and Applications of Biodegradable Elastomers in Regenerative Medicine
Serrano, M. C., Chung, E. J., & Ameer, G. A. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200901040 · Cited by 185
Bioreactors for Cardiovascular Cell and Tissue Growth: A Review
Barron, V., Lyons, E., Stenson-Cox, C., McHugh, P. E., & Pandit, A. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1603260 · Cited by 182
Syedain, Z. H., Weinberg, J. S., & Tranquillo, R. T. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0711217105 · Cited by 179
Cardiac Tissue Engineering for Replacement Therapy
Zimmermann, W.-H., & Eschenhagen, T. (2003) · Heart Failure Reviews · doi:10.1023/a:1024725818835 · Cited by 179
Comparison of aortic valve allograft decellularization techniques in the rat
Meyer, S. R., Chiu, B., Churchill, T. A., Zhu, L., Lakey, J. R. T., & Ross, D. B. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30777 · Cited by 176
Dijkman, P. E., Driessen-Mol, A., Frese, L., Hoerstrup, S. P., & Baaijens, F. P. T. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.03.015 · Cited by 172
Self-citationTissue Engineering Therapy for Cardiovascular Disease
Nugent, H. M., & Edelman, E. R. (2003) · Circulation Research · doi:10.1161/01.res.0000073844.41372.38 · Cited by 172
Krahn, K. N., Bouten, C. V. C., van Tuijl, S., van Zandvoort, M. A. M. J., & Merkx, M. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2006.01.013 · Cited by 171
“As an example, implantable tissue-engineered heart valves that are promising for use in the pulmonary valve position have been generated but do not have suYcient mechanical properties to withstand the higher mechanical loads at the aortic valve position [1].”
Rieder, E., Seebacher, G., Kasimir, M.-T., Eichmair, E., Winter, B., Dekan, B., Wolner, E., Simon, P., & Weigel, G. (2005) · Circulation · doi:10.1161/circulationaha.104.473629 · Cited by 171
Bioreactors for Tissue Engineering: Focus on Mechanical Constraints. A Comparative Review
Bilodeau, K., & Mantovani, D. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2367 · Cited by 170
Scaffolds for tissue engineering of cardiac valves
Jana, S., Tefft, B. J., Spoon, D. B., & Simari, R. D. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.03.014 · Cited by 169
“PGA/PLLA composite fibrous scaffolds were studied to evaluate post-implant characteristics in heart valves [162].”
BackgroundMethodInfluentialEndothelialization of cardiovascular devices
Jana, S. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.08.042 · Cited by 167
Stekelenburg, M., Rutten, M. C. M., Snoeckx, L. H. E. H., & Baaijens, F. P. T. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0183 · Cited by 164
Living, autologous pulmonary artery conduits tissue engineered from human umbilical cord cells
Hoerstrup, S. P., Kadner, A., Breymann, C., Maurus, C. F., Guenter, C. I., Sodian, R., Visjager, J. F., Zund, G., & Turina, M. I. (2002) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(02)03649-4 · Cited by 164
“As a consequence, at the time of implantation, mechanically more appropriate, almost completely autologous replacements were achieved minimizing the issue of adverse foreign material body reactions [6].”
BackgroundMethodSelf-citationWilliams, S. F., Rizk, S., & Martin, D. P. (2013) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2013-0009 · Cited by 163
“first fabricated trileaflet valve scaffolds from PGA meshes coated with P4HB and, then, seeded these scaffolds with autologous ovine myofibroblasts and endothelial cells [ 11 ].”
BackgroundSelf-citationMatrix-dependent adhesion of vascular and valvular endothelial cells in microfluidic channels
Young, E. W. K., Wheeler, A. R., & Simmons, C. A. (2007) · Lab on a Chip · doi:10.1039/b712486d · Cited by 159
Tetralogy of Fallot: Yesterday and Today
Starr, J. P. (2010) · World Journal of Surgery · doi:10.1007/s00268-009-0296-8 · Cited by 158
“Valved conduits have also been created in animal models [82].”
Background(2006) · PubMed · Cited by 149
JetValve: Rapid manufacturing of biohybrid scaffolds for biomimetic heart valve replacement
Capulli, A. K., Emmert, M. Y., Pasqualini, F. S., Kehl, D., Caliskan, E., Lind, J. U., Sheehy, S. P., Park, S. J., Ahn, S., Weber, B., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.04.033 · Cited by 112
Self-citationWang, X., Liu, J., Jing, H., Li, B., Sun, Z., Li, B., Kong, D., Leng, X., & Wang, Z. (2021) · Materials Science and Engineering: C · doi:10.1016/j.msec.2021.111872 · Cited by 25
Metadata
- Authors
- Hoerstrup, S. P., Sodian, R., Daebritz, S., Wang, J., Bacha, E. A., Martin, D. P., Moran, A. M., Guleserian, K. J., Sperling, J. S., Kaushal, S., Vacanti, J. P., Schoen, F. J., & Mayer, J. E.
- Venue
- Circulation
- Published
- 2000-11-07
- Volume
- 102
- Issue
- Supplement 3
- Pages
- III-44-III-49
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2001770837
- Cited by
- 595
- References
- 11
- FWCI
- 19.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.