Background Studies have suggested that restenosis within Palmaz-Schatz stents results from neointimal hyperplasia or chronic stent recoil and occurs more frequently at the articulation. Methods and Results Serial intravascular ultrasound (IVUS) was performed after intervention and at follow-up in 142 stents in 115 lesions. IVUS measurements (external elastic membrane [EEM], stent, and lumen cross-sectional areas [CSAs] and diameters) were performed, and plaque CSA (EEM lumen in reference segments and stent lumen in stented segments), late lumen loss (Δlumen), remodeling (ΔEEM in reference segments and Δstent in stented segments), and tissue growth (Δplaque) were calculated. After intervention, the lumen tended to be smallest at the articulation because of tissue prolapse. At follow-up, tissue growth was uniformly distributed throughout the stent; the tendency for greater neointimal tissue accumulation at the central articulation reached statistical significance only when normalized for the smaller postintervention lumen CSA. In stented segments, late lumen area loss correlated strongly with tissue growth but only weakly with remodeling. Stents affected adjacent vessel segments; remodeling progressively increased and tissue growth progressively decreased at distances from the edge of the stent. These findings were similar in native arteries and saphenous vein grafts and in lesions treated with one or two stents. There was no difference in the postintervention or follow-up lumen (at the junction of the two stents) when overlapped were compared with nonoverlapped stents. Conclusions Late lumen loss and in-stent restenosis were the result of neointimal tissue proliferation, which tended to be uniformly distributed over the length of the stent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Self-citationIntracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance
Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995) · Circulation · doi:10.1161/01.cir.91.6.1676 · Cited by 1,428
Schwartz, R. S., Huber, K. C., Murphy, J. G., Edwards, W. D., Camrud, A. R., Vlietstra, R. E., & Holmes, D. R. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90476-4 · Cited by 1,175
Arterial Remodeling After Coronary Angioplasty: A Serial Intravascular Ultrasound Study
Mintz, G. S., Popma, J. J., Pichard, A. D., Kent, K. M., Satler, L. F., Chiu Wong, S., Hong, M. K., Kovach, J. A., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.1.35 · Cited by 889
Self-citationTobis, J. M., Mallery, J., Mahon, D. J., et al. (1991) · Circulation · doi:10.1161/01.cir.83.3.913 · Cited by 600
Post, M. J., Borst, C., & Kuntz, R. E. (1994) · Circulation · doi:10.1161/01.cir.89.6.2816 · Cited by 409
Intracoronary ultrasound observations during stent implantation.
Nakamura, S., Colombo, A., Gaglione, A., Almagor, Y., Goldberg, S. L., Maiello, L., Finci, L., & Tobis, J. M. (1994) · Circulation · doi:10.1161/01.cir.89.5.2026 · Cited by 394
Kuntz, R. E., Safian, R. D., Carrozza, J. P., Fishman, R. F., Mansour, M., & Baim, D. S. (1992) · Circulation · doi:10.1161/01.cir.86.6.1827 · Cited by 359
Nissen, S. E., Grines, C. L., Gurley, J. C., Sublett, K., Haynie, D., Diaz, C., Booth, D. C., & DeMaria, A. N. (1990) · Circulation · doi:10.1161/01.cir.81.2.660 · Cited by 293
Cited by
Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
Mintz, G. S., Nissen, S. E., Anderson, W. D., Bailey, S. R., Erbel, R., Fitzgerald, P. J., Pinto, F. J., Rosenfield, K., Siegel, R. J., Tuzcu, E. M., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01175-5 · Cited by 2,185
Self-citationAngiographic Patterns of In-Stent Restenosis: Classification and Implications for Long-Term Outcome
Mehran, R., Dangas, G., Abizaid, A. S., Mintz, G. S., Lansky, A. J., Satler, L. F., Pichard, A. D., Kent, K. M., Stone, G. W., & Leon, M. B. (1999) · Circulation · doi:10.1161/01.cir.100.18.1872 · Cited by 1,258
Self-citationThe role of shear stress in the pathogenesis of atherosclerosis
Cunningham, K. S., & Gotlieb, A. I. (2005) · Laboratory Investigation · doi:10.1038/labinvest.3700215 · Cited by 1,151
Schofer, J., Schlüter, M., Gershlick, A. H., Wijns, W., Garcia, E., Schampaert, E., & Breithardt, G. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14462-5 · Cited by 955
Catheter-Based Radiotherapy to Inhibit Restenosis after Coronary Stenting
Teirstein, P. S., Massullo, V., Jani, S., Popma, J. J., Mintz, G. S., Russo, R. J., Schatz, R. A., Guarneri, E. M., Steuterman, S., Morris, N. B., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199706123362402 · Cited by 942
Self-citationKornowski, R., Hong, M. K., Tio, F. O., Bramwell, O., Wu, H., & Leon, M. B. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00450-6 · Cited by 844
Self-citationIntravascular Ultrasound: Novel Pathophysiological Insights and Current Clinical Applications
Nissen, S. E., & Yock, P. (2001) · Circulation · doi:10.1161/01.cir.103.4.604 · Cited by 840
Predictive Factors of Restenosis After Coronary Stent Placement
Kastrati, A., Schömig, A., Elezi, S., Schühlen, H., Dirschinger, J., Hadamitzky, M., Wehinger, A., Hausleiter, J., Walter, H., & Neumann, F.-J. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00334-3 · Cited by 685
A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents
Babapulle, M. N., Joseph, L., Bélisle, P., Brophy, J. M., & Eisenberg, M. J. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16850-5 · Cited by 645
Inflammation and Restenosis in the Stent Era
Welt, F. G. P., & Rogers, C. (2002) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000037100.44766.5b · Cited by 628
Yakacki, C. M., Shandas, R., Lanning, C., Rech, B., Eckstein, A., & Gall, K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.030 · Cited by 618
Smith, S. C., Dove, J. T., Jacobs, A. K., Kennedy, J. W., Kereiakes, D., Kern, M. J., Kuntz, R. E., Popma, J. J., Schaff, H. V., Williams, D. O., et al. (2001) · Circulation · doi:10.1161/01.cir.103.24.3019 · Cited by 608
Self-citationDevelopments in metallic biodegradable stents☆
Hermawan, H., Dubé, D., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.006 · Cited by 604
Schampaert, E., Cohen, E. A., Schlüter, M., Reeves, F., Traboulsi, M., Title, L. M., Kuntz, R. E., & Popma, J. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.024 · Cited by 575
Self-citationACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention
Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., Whitlow, P. L., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.12.001 · Cited by 532
Serruys, P. W., Onuma, Y., Dudek, D., Smits, P. C., Koolen, J., Chevalier, B., de Bruyne, B., Thuesen, L., McClean, D., van Geuns, R.-J., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.05.050 · Cited by 525
Garg, S., & Serruys, P. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.007 · Cited by 501
Nordmann, A. J., Briel, M., & Bucher, H. C. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl282 · Cited by 480
A Paclitaxel-Eluting Stent for the Prevention of Coronary Restenosis
Park, S.-J., Shim, W. H., Ho, D. S., Raizner, A. E., Park, S.-W., Hong, M.-K., Lee, C. W., Choi, D., Jang, Y., Lam, R., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021007 · Cited by 456
Self-citationKornowski, R., Mintz, G. S., Kent, K. M., Pichard, A. D., Satler, L. F., Bucher, T. A., Hong, M. K., Popma, J. J., & Leon, M. B. (1997) · Circulation · doi:10.1161/01.cir.95.6.1366 · Cited by 451
Self-citationOnuma, Y., & Serruys, P. W. (2011) · Circulation · doi:10.1161/circulationaha.110.971606 · Cited by 434
Clinical restenosis after coronary stenting: perspectives from multicenter clinical trials
Cutlip, D. E., Chauhan, M. S., Baim, D. S., Ho, K. K. L., Popma, J. J., Carrozza, J. P., Cohen, D. J., & Kuntz, R. E. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02597-4 · Cited by 423
Self-citationCoronary in-stent restenosis: Current status and future strategies
Lowe, H. C., Oesterle, S. N., & Khachigian, L. M. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01742-9 · Cited by 414
Giustino, G., Colombo, A., Camaj, A., Yasumura, K., Mehran, R., Stone, G. W., Kini, A., & Sharma, S. K. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2022.05.017 · Cited by 413
Grewe, P. H., Deneke, T., Machraoui, A., Barmeyer, J., & Müller, K.-M. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00486-6 · Cited by 401
Anti-inflammatory and immunomodulatory effects of statins
Blanco-Colio, L. M., Tuñón, J., Martín-Ventura, J. L., & Egido, J. (2003) · Kidney International · doi:10.1046/j.1523-1755.2003.00744.x · Cited by 347
Folate Therapy and In-Stent Restenosis after Coronary Stenting
Lange, H., Suryapranata, H., De Luca, G., Börner, C., Dille, J., Kallmayer, K., Pasalary, M. N., Scherer, E., & Dambrink, J.-H. E. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032845 · Cited by 336
Wentzel, J. J., Krams, R., Schuurbiers, J. C. H., Oomen, J. A., Kloet, J., van der Giessen, W. J., Serruys, P. W., & Slager, C. J. (2001) · Circulation · doi:10.1161/01.cir.103.13.1740 · Cited by 335
Restenosis after coronary placement of various stent types
Kastrati, A., Mehilli, J., Dirschinger, J., Pache, J., Ulm, K., Schühlen, H., Seyfarth, M., Schmitt, C., Blasini, R., Neumann, F.-J., et al. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01268-6 · Cited by 324
Coronary stents: historical development, current status and future directions
Iqbal, J., Gunn, J., & Serruys, P. W. (2013) · British Medical Bulletin · doi:10.1093/bmb/ldt009 · Cited by 319
Serruys, P. W., Onuma, Y., Ormiston, J. A., de Bruyne, B., Regar, E., Dudek, D., Thuesen, L., Smits, P. C., Chevalier, B., McClean, D., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.970772 · Cited by 307
Lu, J., Rao, M. P., MacDonald, N. C., Khang, D., & Webster, T. J. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.07.008 · Cited by 290
Predictors of Restenosis After Coronary Stent Implantation
Bauters, C., Hubert, E., Prat, A., Bougrimi, K., Van Belle, E., McFadden, E. P., Amouyel, P., Lablanche, J.-M., & Bertrand, M. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00076-x · Cited by 275
Van Belle, E., Bauters, C., Hubert, E., Bodart, J.-C., Abolmaali, K., Meurice, T., McFadden, E. P., Lablanche, J.-M., & Bertrand, M. E. (1997) · Circulation · doi:10.1161/01.cir.96.5.1454 · Cited by 270
Bioresorbable scaffolds: rationale, current status, challenges, and future
Iqbal, J., Onuma, Y., Ormiston, J., Abizaid, A., Waksman, R., & Serruys, P. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht542 · Cited by 269
Serruys, P. (1999) · European Heart Journal · doi:10.1053/euhj.1998.1150 · Cited by 259
The Road to Bioabsorbable Stents: Reaching Clinical Reality?
Erne, P., Schier, M., & Resink, T. J. (2006) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-004-0341-9 · Cited by 249
Clinical and quantitative coronary angiographic predictors of coronary restenosis
Mercado, N., Boersma, E., Wijns, W., Gersh, B. J., Morillo, C. A., de Valk, V., van Es, G.-A., Grobbee, D. E., & Serruys, P. W. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01431-0 · Cited by 175
Deftereos, S., Giannopoulos, G., Papoutsidakis, N., Panagopoulou, V., Kossyvakis, C., Raisakis, K., Cleman, M. W., & Stefanadis, C. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.08.726 · Cited by 161
Assessment of vascular wall shear stress and implications for atherosclerotic disease
Papaioannou, T. G., Karatzis, E. N., Vavuranakis, M., Lekakis, J. P., & Stefanadis, C. (2006) · International Journal of Cardiology · doi:10.1016/j.ijcard.2006.03.035 · Cited by 126
Danenberg, H. D., Golomb, G., Groothuis, A., Gao, J., Epstein, H., Swaminathan, R. V., Seifert, P., & Edelman, E. R. (2003) · Circulation · doi:10.1161/01.cir.0000097002.69209.cd · Cited by 104
Kotani, K., Tashiro, J., Yamazaki, K., Nakamura, Y., Miyazaki, A., Bujo, H., Saito, Y., Kanno, T., & Maekawa, M. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2015.08.003 · Cited by 24
Metadata
- Authors
- Hoffmann, R., Mintz, G. S., Dussaillant, G. R., Popma, J. J., Pichard, A. D., Satler, L. F., Kent, K. M., Griffin, J., & Leon, M. B.
- Venue
- Circulation
- Published
- 1996-09-15
- Volume
- 94
- Issue
- 6
- Pages
- 1247-1254
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2076552301
- Cited by
- 1,247
- References
- 12
- FWCI
- 71.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.