Management of Hypertension in the Digital Era: Small Wearable Monitoring Devices for Remote Blood Pressure Monitoring
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Out-of-office blood pressure measurement is an essential part of diagnosing and managing hypertension. In the era of advanced digital health information technology, the approach to achieving this is shifting from traditional methods (ambulatory and home blood pressure monitoring) to wearable devices and technology. Wearable blood pressure monitors allow frequent blood pressure measurements (ideally continuous beat-by-beat monitoring of blood pressure) with minimal stress on the patient. It is expected that wearable devices will dramatically change the quality of detection and management of hypertension by increasing the number of measurements in different situations, allowing accurate detection of phenotypes that have a negative impact on cardiovascular prognosis, such as masked hypertension and abnormal blood pressure variability. Frequent blood pressure measurements and the addition of new features such as monitoring of environmental conditions allows interpretation of blood pressure data in the context of daily stressors and different situations. This new digital approach to hypertension contributes to anticipation medicine, which refers to strategies designed to identify increasing risk and predict the onset of cardiovascular events based on a series of data collected over time, allowing proactive interventions to reduce risk. To achieve this, further research and validation is required to develop wearable blood pressure monitoring devices that provide the same accuracy as current approaches and can effectively contribute to personalized medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2018 ESC/ESH Guidelines for the management of arterial hypertension
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy339 · Cited by 10,286
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.11.006 · Cited by 6,616
Mortality risk attributable to high and low ambient temperature: a multicountry observational study
Gasparrini, A., Guo, Y., Hashizume, M., Lavigne, E., Zanobetti, A., Schwartz, J., Tobias, A., Tong, S., Rocklöv, J., Forsberg, B., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(14)62114-0 · Cited by 2,965
The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationKario, K., Pickering, T. G., Umeda, Y., Hoshide, S., Hoshide, Y., Morinari, M., Murata, M., Kuroda, T., Schwartz, J. E., & Shimada, K. (2003) · Circulation · doi:10.1161/01.cir.0000056521.67546.aa · Cited by 1,250
Self-citationEuropean Society of Hypertension practice guidelines for ambulatory blood pressure monitoring
Parati, G., Stergiou, G., O’Brien, E., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000221 · Cited by 1,021
Self-citationWhelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2018.06.010 · Cited by 947
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Nerenberg, K. A., Zarnke, K. B., Leung, A. A., Dasgupta, K., Butalia, S., McBrien, K., Harris, K. C., Nakhla, M., Cloutier, L., Gelfer, M., et al. (2018) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2018.02.022 · Cited by 573
Burke, L. E., Ma, J., Azar, K. M. J., Bennett, G. G., Peterson, E. D., Zheng, Y., Riley, W., Stephens, J., Shah, S. H., Suffoletto, B., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000232 · Cited by 516
Niiranen, T. J., Hänninen, M.-R., Johansson, J., Reunanen, A., & Jula, A. M. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.149336 · Cited by 390
Stergiou, G. S., Asayama, K., Thijs, L., Kollias, A., Niiranen, T. J., Hozawa, A., Boggia, J., Johansson, J. K., Ohkubo, T., Tsuji, I., et al. (2014) · Hypertension · doi:10.1161/hypertensionaha.113.02741 · Cited by 304
Nocturnal Hypertension: New Technology and Evidence
Kario, K. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.10971 · Cited by 298
Self-citationWard, A. M., Takahashi, O., Stevens, R., & Heneghan, C. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32834e4aed · Cited by 296
Pulse Transit Time as an Indicator of Arterial Blood Pressure
Geddes, L. A., Voelz, M. H., Babbs, C. F., Bourland, J. D., & Tacker, W. A. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb01545.x · Cited by 293
A content analysis of smartphone–based applications for hypertension management
Kumar, N., Khunger, M., Gupta, A., & Garg, N. (2015) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2014.12.001 · Cited by 208
McLean, G., Band, R., Saunderson, K., Hanlon, P., Murray, E., Little, P., McManus, R. J., Yardley, L., & Mair, F. S. (2016) · Journal of Hypertension · doi:10.1097/hjh.0000000000000859 · Cited by 168
Kario, K., Kanegae, H., Tomitani, N., Okawara, Y., Fujiwara, T., Yano, Y., Hoshide, S., & on behalf of the J-HOP Study Group (2019) · Hypertension · doi:10.1161/hypertensionaha.118.12740 · Cited by 167
Self-citationKario, K., Shin, J., Chen, C., Buranakitjaroen, P., Chia, Y., Divinagracia, R., Nailes, J., Hoshide, S., Siddique, S., Sison, J., et al. (2019) · The Journal of Clinical Hypertension · doi:10.1111/jch.13652 · Cited by 164
Self-citationKario, K., Saito, I., Kushiro, T., Teramukai, S., Ishikawa, Y., Mori, Y., Kobayashi, F., & Shimada, K. (2014) · Hypertension · doi:10.1161/hypertensionaha.114.04262 · Cited by 162
Self-citationKario, K. (2016) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2016.04.001 · Cited by 144
Self-citationBilo, G., Zorzi, C., Ochoa Munera, J. E., Torlasco, C., Giuli, V., & Parati, G. (2015) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000124 · Cited by 143
Kuwabara, M., Harada, K., Hishiki, Y., & Kario, K. (2019) · The Journal of Clinical Hypertension · doi:10.1111/jch.13499 · Cited by 140
Self-citationNighttime Home Blood Pressure and the Risk of Hypertensive Target Organ Damage
Ishikawa, J., Hoshide, S., Eguchi, K., Ishikawa, S., Shimada, K., Kario, K., & for the Japan Morning Surge-Home Blood Pressure Study Investigators Group (2012) · Hypertension · doi:10.1161/hypertensionaha.112.198101 · Cited by 123
Self-citationPicone, D. S., Deshpande, R. A., Schultz, M. G., Fonseca, R., Campbell, N. R. C., Delles, C., Hecht Olsen, M., Schutte, A. E., Stergiou, G., Padwal, R., et al. (2020) · Hypertension · doi:10.1161/hypertensionaha.120.14719 · Cited by 118
Kario, K., Shimbo, D., Tomitani, N., Kanegae, H., Schwartz, J. E., & Williams, B. (2020) · The Journal of Clinical Hypertension · doi:10.1111/jch.13799 · Cited by 112
Self-citationHome blood pressure monitoring: Australian Expert Consensus Statement
Sharman, J. E., Howes, F. S., Head, G. A., McGrath, B. P., Stowasser, M., Schlaich, M., Glasziou, P., & Nelson, M. R. (2015) · Journal of Hypertension · doi:10.1097/hjh.0000000000000673 · Cited by 83
Hara, A., Tanaka, K., Ohkubo, T., Kondo, T., Kikuya, M., Metoki, H., Hashimoto, T., Satoh, M., Inoue, R., Asayama, K., et al. (2012) · Hypertension · doi:10.1161/hypertensionaha.111.174938 · Cited by 79
Islam, S. M. S., Cartledge, S., Karmakar, C., Rawstorn, J. C., Fraser, S. F., Chow, C., & Maddison, R. (2019) · JMIR mHealth and uHealth · doi:10.2196/14706 · Cited by 57
Cited by
Kumar, Y., Koul, A., Singla, R., & Ijaz, M. F. (2023) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-021-03612-z · Cited by 1,040
RetractedOmboni, S., Padwal, R. S., Alessa, T., Benczúr, B., Green, B. B., Hubbard, I., Kario, K., Khan, N. A., Konradi, A., Logan, A. G., et al. (2022) · Connected Health · doi:10.20517/ch.2021.03 · Cited by 370
Self-citationLi, S., Wang, H., Ma, W., Qiu, L., Xia, K., Zhang, Y., Lu, H., Zhu, M., Liang, X., Wu, X.-E., et al. (2023) · Science Advances · doi:10.1126/sciadv.adh0615 · Cited by 252
Vo, D.-K., & Trinh, K. T. L. (2024) · Biosensors · doi:10.3390/bios14110560 · Cited by 231
“Tracking blood pressure continuously can spot high blood pressure and encourage people to see their doctor sooner [46].”
Continuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos
Kireev, D., Sel, K., Ibrahim, B., Kumar, N., Akbari, A., Jafari, R., & Akinwande, D. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01145-w · Cited by 225
Metadata
- Authors
- Kario, K.
- Venue
- Hypertension
- Published
- 2020-09
- Volume
- 76
- Issue
- 3
- Pages
- 640-650
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W3047559810
- Cited by
- 240
- References
- 32
- FWCI
- 17.74
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.