Effect of Spontaneous Breathing Trial Duration on Outcome of Attempts to Discontinue Mechanical Ventilation
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The duration of spontaneous breathing trials before extubation has been set at 2 h in research studies, but the optimal duration is not known. We conducted a prospective, multicenter study involving 526 ventilator-supported patients considered ready for weaning, to compare clinical outcomes for trials of spontaneous breathing with target durations of 30 and 120 min. Of the 270 and 256 patients in the 30- and 120-min trial groups, respectively, 237 (87.8%) and 216 (84.8%), respectively, completed the trial without distress and were extubated (p = 0.32); 32 (13.5%) and 29 (13.4%), respectively, of these patients required reintubation within 48 h. The percentage of patients who remained extubated for 48 h after a spontaneous breathing trial did not differ in the 30- and 120-min trial groups (75.9% versus 73.0%, respectively, p = 0.43). The 30- and 120-min trial groups had similar within-unit mortality rates (13 and 9%, respectively) and in-hospital mortality rates (19 and 18%, respectively). Reintubation was required in 61 (13.5%) patients, and these patients had a higher mortality (20 of 61, 32.8%) than did patients who tolerated extubation (18 of 392, 4.6%) (p < 0.001). Neither measurements of respiratory frequency, heart rate, systolic blood pressure, and oxygen saturation during the trial, nor other functional measurements before the trial discriminated between patients who required reintubation from those who tolerated extubation. In conclusion, after a first trial of spontaneous breathing, successful extubation was achieved equally effectively with trials targeted to last 30 and 120 min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of serial measurements in medical research.
Matthews, J. N., Altman, D. G., Campbell, M. J., & Royston, P. (1990) · BMJ · doi:10.1136/bmj.300.6719.230 · Cited by 3,136
A Comparison of Four Methods of Weaning Patients from Mechanical Ventilation
Esteban, A., Frutos, F., Tobin, M. J., Alía, I., Solsona, J. F., Valverdu, V., Fernández, R., de la Cal, M. A., Benito, S., Tomás, R., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199502093320601 · Cited by 1,549
Self-citationYang, K. L., & Tobin, M. J. (1991) · New England Journal of Medicine · doi:10.1056/nejm199105233242101 · Cited by 1,378
Self-citationEly, E. W., Baker, A. M., Dunagan, D. P., Burke, H. L., Smith, A. C., Kelly, P. T., Johnson, M. M., Browder, R. W., Bowton, D. L., & Haponik, E. F. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612193352502 · Cited by 1,346
Brochard, L., Rauss, A., Benito, S., Conti, G., Mancebo, J., Rekik, N., Gasparetto, A., & Lemaire, F. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.4.7921460 · Cited by 1,122
Effect of Failed Extubation on the Outcome of Mechanical Ventilation
Epstein, S. K., Ciubotaru, R. L., & Wong, J. B. (1997) · Chest · doi:10.1378/chest.112.1.186 · Cited by 892
Fagon, J.-Y., Chastre, J., Domart, Y., Trouillet, J.-L., Pierre, J., Darne, C., & Gibert, C. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/139.4.877 · Cited by 823
Extubation Outcome after Spontaneous Breathing Trials with T-Tube or Pressure Support Ventilation
ESTEBAN, A., ALÍA, I., GORDO, F., FERNÁNDEZ, R., SOLSONA, J. F., VALLVERDÚ, I., MACÍAS, S., ALLEGUE, J. M., BLANCO, J., CARRIEDO, D., et al. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.2.9610109 · Cited by 795
Self-citationSchwartz, D. E., Matthay, M. A., & Cohen, N. H. (1995) · Anesthesiology · doi:10.1097/00000542-199502000-00007 · Cited by 676
Jubran, A., & Tobin, M. J. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.3.9117025 · Cited by 463
Self-citation
Cited by
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
Dellinger, R. P., Levy, M. M., Carlet, J. M., Bion, J., Parker, M. M., Jaeschke, R., Reinhart, K., Angus, D. C., Brun-Buisson, C., Beale, R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-007-0934-2 · Cited by 6,772
Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock
Dellinger, R. P., Carlet, J. M., Masur, H., Gerlach, H., Calandra, T., Cohen, J., Gea-Banacloche, J., Keh, D., Marshall, J. C., Parker, M. M., et al. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2210-z · Cited by 3,321
Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock
Dellinger, R. P., Carlet, J. M., Masur, H., Gerlach, H., Calandra, T., Cohen, J., Gea-Banacloche, J., Keh, D., Marshall, J. C., Parker, M. M., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000117317.18092.e4 · Cited by 3,018
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Evidence-Based Guidelines for Weaning and Discontinuing Ventilatory Support
MacIntyre, N. R. (2001) · Chest · doi:10.1378/chest.120.6_suppl.375s · Cited by 1,240
Noninvasive Positive-Pressure Ventilation for Respiratory Failure after Extubation
Esteban, A., Frutos-Vivar, F., Ferguson, N. D., Arabi, Y., Apezteguía, C., González, M., Epstein, S. K., Hill, N. S., Nava, S., Soares, M.-A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032736 · Cited by 894
Self-citationEvolution of Mechanical Ventilation in Response to Clinical Research
Esteban, A., Ferguson, N. D., Meade, M. O., Frutos-Vivar, F., Apezteguia, C., Brochard, L., Raymondos, K., Nin, N., Hurtado, J., Tomicic, V., et al. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200706-893oc · Cited by 725
Self-citationEvolution of Mortality over Time in Patients Receiving Mechanical Ventilation
Esteban, A., Frutos-Vivar, F., Muriel, A., Ferguson, N. D., Peñuelas, O., Abraira, V., Raymondos, K., Rios, F., Nin, N., Apezteguía, C., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201212-2169oc · Cited by 676
Self-citationThe Decision to Extubate in the Intensive Care Unit
Thille, A. W., Richard, J.-C. M., & Brochard, L. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201208-1523ci · Cited by 576
Early Noninvasive Ventilation Averts Extubation Failure in Patients at Risk: A Randomized Trial
Ferrer, M., Valencia, M., Nicolas, J. M., Bernadich, O., Badia, J. R., & Torres, A. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200505-718oc · Cited by 573
Self-citationNoninvasive ventilation to prevent respiratory failure after extubation in high-risk patients*
Nava, S., Gregoretti, C., Fanfulla, F., Squadrone, E., Grassi, M., Carlucci, A., Beltrame, F., & Navalesi, P. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000186416.44752.72 · Cited by 552
Soummer, A., Perbet, S., Brisson, H., Arbelot, C., Constantin, J.-M., Lu, Q., & Rouby, J.-J. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31824e68ae · Cited by 519
Advances in Mechanical Ventilation
Tobin, M. J. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106283442606 · Cited by 475
Self-citationKhamiees, M., Raju, P., DeGirolamo, A., Amoateng-Adjepong, Y., & Manthous, C. A. (2001) · Chest · doi:10.1378/chest.120.4.1262 · Cited by 466
BERSTEN, A. D., EDIBAM, C., HUNT, T., MORAN, J., & GROUP, T. A. A. N. Z. I. C. S. C. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.4.2101124 · Cited by 455
Pontes-Arruda, A., Aragão, A. M. A., & Albuquerque, J. D. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000234033.65657.b6 · Cited by 423
Risk Factors for Extubation Failure in Patients Following a Successful Spontaneous Breathing Trial
Frutos-Vivar, F., Ferguson, N. D., Esteban, A., Epstein, S. K., Arabi, Y., Apezteguía, C., González, M., Hill, N. S., Nava, S., D’Empaire, G., et al. (2006) · Chest · doi:10.1378/chest.130.6.1664 · Cited by 406
Self-citationPredictors of Successful Extubation in Neurosurgical Patients
NAMEN, A. M., WESLEY ELY, E., TATTER, S. B., DOUGLAS CASE, L., LUCIA, M. A., SMITH, A., LANDRY, S., WILSON, J. A., GLAZIER, S. S., BRANCH, C. L., et al. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2003060 · Cited by 355
Peñuelas, O., Frutos-Vivar, F., Fernández, C., Anzueto, A., Epstein, S. K., Apezteguía, C., González, M., Nin, N., Raymondos, K., Tomicic, V., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201011-1887oc · Cited by 350
Self-citationFerrer, M., Sellarés, J., Valencia, M., Carrillo, A., Gonzalez, G., Badia, J. R., Nicolas, J. M., & Torres, A. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61038-2 · Cited by 341
Self-citationGarnacho-Montero, J., Amaya-Villar, R., García-Garmendía, J. L., Madrazo-Osuna, J., & Ortiz-Leyba, C. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000153521.41848.7e · Cited by 338
Weaning and extubation readiness in pediatric patients*
Newth, C. J. L., Venkataraman, S., Willson, D. F., Meert, K. L., Harrison, R., Dean, J. M., Pollack, M., Zimmerman, J., Anand, K. J. S., Carcillo, J. A., et al. (2009) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e318193724d · Cited by 328
A Prospective, Controlled Trial of a Protocol-based Strategy to Discontinue Mechanical Ventilation
Krishnan, J. A., Moore, D., Robeson, C., Rand, C. S., & Fessler, H. E. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200306-761oc · Cited by 309
Subirà, C., Hernández, G., Vázquez, A., Rodríguez-García, R., González-Castro, A., García, C., Rubio, O., Ventura, L., López, A., de la Torre, M.-C., et al. (2019) · JAMA · doi:10.1001/jama.2019.7234 · Cited by 309
Self-citationMechanical Ventilator Weaning Protocols Driven by Nonphysician Health-Care Professionals
Ely, E. W., Meade, M. O., Haponik, E. F., Kollef, M. H., Cook, D. J., Guyatt, G. H., & Stoller, J. K. (2001) · Chest · doi:10.1378/chest.120.6_suppl.454s · Cited by 288
Epstein, S. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1268-8 · Cited by 288
Incidence and outcome of weaning from mechanical ventilation according to new categories
Funk, G.-C., Anders, S., Breyer, M.-K., Burghuber, O. C., Edelmann, G., Heindl, W., Hinterholzer, G., Kohansal, R., Schuster, R., Schwarzmaier-D'Assie, A., et al. (2010) · European Respiratory Journal · doi:10.1183/09031936.00056909 · Cited by 274
Weaning Patients from the Ventilator
McConville, J. F., & Kress, J. P. (2012) · New England Journal of Medicine · doi:10.1056/nejmra1203367 · Cited by 270
Ely, E. W., Wheeler, A. P., Thompson, B. T., Ancukiewicz, M., Steinberg, K. P., Bernard, G. R., & for the Acute Respiratory Distress Syndrome Network (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-136-1-200201010-00007 · Cited by 268
Uchino, S., Bellomo, R., Morimatsu, H., Morgera, S., Schetz, M., Tan, I., Bouman, C., Macedo, E., Gibney, N., Tolwani, A., et al. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a38241 · Cited by 266
Thille, A. W., Boissier, F., Ben Ghezala, H., Razazi, K., Mekontso-Dessap, A., & Brun-Buisson, C. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000000748 · Cited by 261
Burns, K. E., Meade, M. O., Premji, A., & Adhikari, N. K. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004127.pub3 · Cited by 220
Effect of Unplanned Extubation on Outcome of Mechanical Ventilation
EPSTEIN, S. K., NEVINS, M. L., & CHUNG, J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.6.9908068 · Cited by 219
“Extubation failure resulting from either upper airway obstruction or an inability to protect the airway has little impact on outcome ( 12 , 13, 15).”
BackgroundElkins, M., & Dentice, R. (2015) · Journal of Physiotherapy · doi:10.1016/j.jphys.2015.05.016 · Cited by 204
Physiologic Determinants of Ventilator Dependence in Long-term Mechanically Ventilated Patients
PURRO, A., APPENDINI, L., DE GAETANO, A., GUDJONSDOTTIR, M., DONNER, C. F., & ROSSI, A. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.4.9812160 · Cited by 189
“The circuit included the pneumotachograph, connectors with the side port to sample Pao, and a T-tube (4).”
BackgroundInfluentialNavalesi, P., Frigerio, P., Moretti, M. P., Sommariva, M., Vesconi, S., Baiardi, P., & Levati, A. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31818b35f2 · Cited by 188
Determinants of tracheostomy decannulation: an international survey
Stelfox, H. T., Crimi, C., Berra, L., Noto, A., Schmidt, U., Bigatello, L. M., & Hess, D. (2008) · Critical Care · doi:10.1186/cc6802 · Cited by 180
“The incidence of extubation failure is reported to be between 2% and 25% of extubation attempts and is associated with increased hospital mortality, prolonged ICU and hospital stays, and more frequent need for long-term acute care [27-29].”
BackgroundTracheostomy practice in adults with acute respiratory failure
Freeman, B. D., & Morris, P. E. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31825bc948 · Cited by 176
Mechanical Ventilation in ARDS
Girard, T. D., & Bernard, G. R. (2007) · Chest · doi:10.1378/chest.06-1515 · Cited by 174
Prediction of extubation outcome in critically ill patients: a systematic review and meta-analysis
Torrini, F., Gendreau, S., Morel, J., Carteaux, G., Thille, A. W., Antonelli, M., & Mekontso Dessap, A. (2021) · Critical Care · doi:10.1186/s13054-021-03802-3 · Cited by 163
Spadaro, S., Grasso, S., Mauri, T., Dalla Corte, F., Alvisi, V., Ragazzi, R., Cricca, V., Biondi, G., Di Mussi, R., Marangoni, E., et al. (2016) · Critical Care · doi:10.1186/s13054-016-1479-y · Cited by 163
“The enrolled patients underwent a SBT that comprised spontaneous ventilation through a T-tube circuit with the FiO2 set at the same level used during mechanical ventilation [33].”
MethodGirault, C., Bubenheim, M., Abroug, F., Diehl, J. L., Elatrous, S., Beuret, P., Richecoeur, J., L'Her, E., Hilbert, G., Capellier, G., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201101-0035oc · Cited by 163
“Bronchial hypersecretion 7 (10) 12 (17) 6 (9) 0.”
BackgroundInfluentialBurns, K. E. A., Adhikari, N. K. J., Keenan, S. P., & Meade, M. (2009) · BMJ · doi:10.1136/bmj.b1574 · Cited by 162
Farghaly, S., & Hasan, A. A. (2017) · Australian Critical Care · doi:10.1016/j.aucc.2016.03.004 · Cited by 159
Spontaneous-Breathing Trials with Pressure-Support Ventilation or a T-Piece
Thille, A. W., Gacouin, A., Coudroy, R., Ehrmann, S., Quenot, J.-P., Nay, M.-A., Guitton, C., Contou, D., Labro, G., Reignier, J., et al. (2022) · New England Journal of Medicine · doi:10.1056/nejmoa2209041 · Cited by 159
Vidotto, M. C., Sogame, L. C. M., Calciolari, C. C., Nascimento, O. A., & Jardim, J. R. (2008) · Neurocritical Care · doi:10.1007/s12028-008-9059-x · Cited by 47
Dellinger, R. P., Levy, M. M., Carlet, J. M., Bion, J., Parker, M. M., Jaeschke, R., Reinhart, K., Angus, D. C., Brun-Buisson, C., Beale, R., et al. (2008) · Critical Care Medicine · doi:10.1097/01.ccm.0000298158.12101.41 · Cited by 9
LIU, Y., MU, Y., LI, G.-Q., YU, X., LI, P.-J., SHEN, Z.-Q., WANG, H.-X., & WEI, L.-Q. (2015) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2015.2678 · Cited by 8
Metadata
- Authors
- ESTEBAN, A., ALÍA, I., TOBIN, M. J., GIL, A., GORDO, F., VALLVERDÚ, I., BLANCH, L., BONET, A., VÁZQUEZ, A., de PABLO, R., TORRES, A., de la CAL, M. A., & MACÍAS, S.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-02-01
- Volume
- 159
- Issue
- 2
- Pages
- 512-518
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2140771005
- Cited by
- 773
- References
- 15
- FWCI
- 21.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.