A Review of the Foreign-body Response to Subcutaneously-implanted Devices: The Role of Macrophages and Cytokines in Biofouling and Fibrosis
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
The biological response to implanted biomaterials in mammals is a complex series of events that involves many biochemical pathways. Shortly after implantation, fibrinogen and other proteins bind to the device surface, a process known as biofouling. Macrophages then bind to receptors on the proteins, join into multinucleated giant cells, and release transforming growth factor β and other inflammatory cytokines. In response to these signals, quiescent fibroblasts are transformed into myofibroblasts, which synthesize procollagen via activation of Smad mediators. The procollagen becomes crosslinked after secretion into the extracellular space. Mature crosslinked collagen and other extracellular matrix proteins gradually contribute to formation of a hypocellular dense fibrous capsule that becomes impermeable or hypopermeable to many compounds. Porous substrates and angiogenic growth factors can stimulate formation of microvessels, which to some extent can maintain analyte delivery to implanted sensors. However, stimulation by vascular endothelial growth factor alone may lead to formation of leaky, thin-walled, immature vessels. Other growth factors are most probably needed to act upon these immature structures to create more robust vessels. During implantation of foreign bodies, the foreign-body response is difficult to overcome, and thousands of biomaterials have been tested. Biomimicry (i.e., creating membranes whose chemical structure mimics natural cellular compounds) may diminish the response, but as of this writing, it has not been possible to create a stealth material that circumvents the ability of the mammalian surveillance systems to distinguish foreign from self.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mussel-inspired surface chemistry for multifunctional coatings
Lee, H., Dellatore, S. M., Miller, W. M., & Messersmith, P. B. (2007) · Science · doi:10.1126/science.1147241 · Cited by 10,965
Tumor angiogenesis: therapeutic implications
Sherwood, L. M., Parris, E. E., & Folkman, J. (1971) · New England Journal of Medicine · doi:10.1056/nejm197111182852108 · Cited by 10,187
Cellular and molecular mechanisms of fibrosis
Wynn, T. (2008) · The Journal of Pathology · doi:10.1002/path.2277 · Cited by 4,495
Renal fibrosis: New insights into the pathogenesis and therapeutics
Liu, Y. (2006) · Kidney International · doi:10.1038/sj.ki.5000054 · Cited by 1,089
Smad3 as a mediator of the fibrotic response
Flanders, K. C. (2004) · International Journal of Experimental Pathology · doi:10.1111/j.0959-9673.2004.00377.x · Cited by 608
Neovascularization of synthetic membranes directed by membrane microarchitecture
Brauker, J. H., Carr‐Brendel, V. E., Martinson, L. A., Crudele, J., Johnston, W. D., & Johnson, R. C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291208 · Cited by 517
Khan, R., & Sheppard, R. (2006) · Immunology · doi:10.1111/j.1365-2567.2006.02336.x · Cited by 501
Fibrin(ogen) mediates acute inflammatory responses to biomaterials.
Tang, L., & Eaton, J. W. (1993) · The Journal of experimental medicine · doi:10.1084/jem.178.6.2147 · Cited by 449
The lightweight and large porous mesh concept for hernia repair
Klosterhalfen, B., Junge, K., & Klinge, U. (2005) · Expert Review of Medical Devices · doi:10.1586/17434440.2.1.103 · Cited by 380
HAO, X., SILVA, E., MANSSONBROBERG, A., GRINNEMO, K., SIDDIQUI, A., DELLGREN, G., WARDELL, E., BRODIN, L., MOONEY, D., & SYLVEN, C. (2007) · Cardiovascular Research · doi:10.1016/j.cardiores.2007.03.028 · Cited by 377
Cited by
Zwitterionic hydrogels implanted in mice resist the foreign-body reaction
Zhang, L., Cao, Z., Bai, T., Carr, L., Ella-Menye, J.-R., Irvin, C., Ratner, B. D., & Jiang, S. (2013) · Nature Biotechnology · doi:10.1038/nbt.2580 · Cited by 1,035
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Continuous glucose monitoring and metrics for clinical trials: an international consensus statement
Battelino, T., Alexander, C. M., Amiel, S. A., Arreaza-Rubin, G., Beck, R. W., Bergenstal, R. M., Buckingham, B. A., Carroll, J., Ceriello, A., Chow, E., et al. (2023) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00319-9 · Cited by 831
Biomaterials: Foreign Bodies or Tuners for the Immune Response?
Mariani, E., Lisignoli, G., Borzì, R. M., & Pulsatelli, L. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20030636 · Cited by 706
“Even if biomaterial implants have the ability to induce a FBR according to context specific features, the clinical manifestations widely differ for gravity and for the resulting implant outcome [6,12,19,20].”
BackgroundThe Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Hydrogel interfaces for merging humans and machines
Yuk, H., Wu, J., & Zhao, X. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00483-4 · Cited by 661
Vegas, A. J., Veiseh, O., Doloff, J. C., Ma, M., Tam, H. H., Bratlie, K., Li, J., Bader, A. R., Langan, E., Olejnik, K., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3462 · Cited by 551
Extracellular matrix-based biomaterial scaffolds and the host response
Aamodt, J. M., & Grainger, D. W. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.02.003 · Cited by 509
The Formation and Function of Granulomas
Pagán, A. J., & Ramakrishnan, L. (2018) · Annual Review of Immunology · doi:10.1146/annurev-immunol-032712-100022 · Cited by 430
From Wearable Sensors to Smart Implants-–Toward Pervasive and Personalized Healthcare
Andreu-Perez, J., Leff, D. R., Ip, H. M. D., & Yang, G.-Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2422751 · Cited by 383
A prevascularized subcutaneous device-less site for islet and cellular transplantation
Pepper, A. R., Gala-Lopez, B., Pawlick, R., Merani, S., Kin, T., & Shapiro, A. M. J. (2015) · Nature Biotechnology · doi:10.1038/nbt.3211 · Cited by 381
Zhang, D., Chen, Q., Shi, C., Chen, M., Ma, K., Wan, J., & Liu, R. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202007226 · Cited by 303
Doloff, J. C., Veiseh, O., de Mezerville, R., Sforza, M., Perry, T. A., Haupt, J., Jamiel, M., Chambers, C., Nash, A., Aghlara-Fotovat, S., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00739-4 · Cited by 302
Doloff, J. C., Veiseh, O., Vegas, A. J., Tam, H. H., Farah, S., Ma, M., Li, J., Bader, A., Chiu, A., Sadraei, A., et al. (2017) · Nature Materials · doi:10.1038/nmat4866 · Cited by 283
Fang, H., Yu, K. J., Gloschat, C., Yang, Z., Song, E., Chiang, C.-H., Zhao, J., Won, S. M., Xu, S., Trumpis, M., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0038 · Cited by 278
Hernandez, J. L., & Woodrow, K. A. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202102087 · Cited by 259
Domesticating the foreign body response: recent advances and applications
Veiseh, O., & Vegas, A. J. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.08.010 · Cited by 245
Zwitterionic polymers and hydrogels for antibiofouling applications in implantable devices
Erathodiyil, N., Chan, H.-M., Wu, H., & Ying, J. Y. (2020) · Materials Today · doi:10.1016/j.mattod.2020.03.024 · Cited by 226
Examination of the foreign body response to biomaterials by nonlinear intravital microscopy
Dondossola, E., Holzapfel, B. M., Alexander, S., Filippini, S., Hutmacher, D. W., & Friedl, P. (2016) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0007 · Cited by 215
The Foreign Body Response Demystified
Chandorkar, Y., K, R., & Basu, B. (2019) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00252 · Cited by 201
Discoidal Porous Silicon Particles: Fabrication and Biodistribution in Breast Cancer Bearing Mice
Godin, B., Chiappini, C., Srinivasan, S., Alexander, J. F., Yokoi, K., Ferrari, M., Decuzzi, P., & Liu, X. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201200869 · Cited by 195
Implant Fibrosis and the Underappreciated Role of Myofibroblasts in the Foreign Body Reaction
Noskovicova, N., Hinz, B., & Pakshir, P. (2021) · Cells · doi:10.3390/cells10071794 · Cited by 184
Farah, S., Doloff, J. C., Müller, P., Sadraei, A., Han, H. J., Olafson, K., Vyas, K., Tam, H. H., Hollister-Lock, J., Kowalski, P. S., et al. (2019) · Nature Materials · doi:10.1038/s41563-019-0377-5 · Cited by 181
Smart Biomaterials: Recent Advances and Future Directions
Kowalski, P. S., Bhattacharya, C., Afewerki, S., & Langer, R. (2018) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00889 · Cited by 181
Masquelet's induced membrane technique: Review of current concepts and future directions
Alford, A. I., Nicolaou, D., Hake, M., & McBride‐Gagyi, S. (2021) · Journal of Orthopaedic Research · doi:10.1002/jor.24978 · Cited by 173
Foreign Body Reaction to Implantable Biosensors: Effects of Tissue Trauma and Implant Size
Wang, Y., Vaddiraju, S., Gu, B., Papadimitrakopoulos, F., & Burgess, D. J. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815601869 · Cited by 107
Amperometric Glucose Sensors: Sources of Error and Potential Benefit of Redundancy
Castle, J. R., & Ward, W. K. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400127 · Cited by 95
Self-citationShokouhi, B., Coban, C., Hasirci, V., Aydin, E., Dhanasingh, A., Shi, N., Koyama, S., Akira, S., Zenke, M., & Sechi, A. S. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.015 · Cited by 77
Prevention of the foreign body response to implantable medical devices by inflammasome inhibition
Barone, D. G., Carnicer-Lombarte, A., Tourlomousis, P., Hamilton, R. S., Prater, M., Rutz, A. L., Dimov, I. B., Malliaras, G. G., Lacour, S. P., Robertson, A. A. B., et al. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2115857119 · Cited by 67
Development of Cationic Polymer Coatings to Regulate Foreign‐Body Responses
Ma, M., Liu, W. F., Hill, P. S., Bratlie, K. M., Siegwart, D. J., Chin, J., Park, M., Guerreiro, J., & Anderson, D. G. (2011) · Advanced Materials · doi:10.1002/adma.201100513 · Cited by 59
Carnicer-Lombarte (2019) · doi:10.1101/829648 · Cited by 46
Investigating Immunomodulatory Biomaterials for Preventing the Foreign Body Response
Kim, A., Downer, M. A., Berry, C. E., Valencia, C., Fazilat, A. Z., & Griffin, M. (2023) · Bioengineering · doi:10.3390/bioengineering10121411 · Cited by 38
Printable microscale interfaces for long-term peripheral nerve mapping and precision control
Otchy, T. M., Michas, C., Lee, B., Gopalan, K., Nerurkar, V., Gleick, J., Semu, D., Darkwa, L., Holinski, B. J., Chew, D. J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18032-4 · Cited by 35
“, 2014) and correlates with a low immune response (Maiti et al., 2007; Salatino et al., 2017; Ward, 2008).”
BackgroundLong-term functionality of transversal intraneural electrodes is improved by dexamethasone treatment
de la Oliva, N., del Valle, J., Delgado-Martinez, I., Mueller, M., Stieglitz, T., & Navarro, X. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2897256 · Cited by 26
In Vivo Evaluation of the Biocompatibility of Biomaterial Device
Frazão, L. P., Vieira de Castro, J., & Neves, N. M. (2020) · Advances in Experimental Medicine and Biology · doi:10.1007/978-981-15-3262-7_8 · Cited by 23
Metadata
- Authors
- Ward, W. K.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2008-09
- Volume
- 2
- Issue
- 5
- Pages
- 768-777
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2165248259
- Cited by
- 325
- References
- 62
- FWCI
- 4.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.