Noninvasive detection of lung cancer by analysis of exhaled breath
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Background: Lung cancer is one of the leading causes of death in Europe and the western world. At present, diagnosis of lung cancer very often happens late in the course of the disease since inexpensive, non-invasive and sufficiently sensitive and specific screening methods are not available. Even though the CT diagnostic methods are good, it must be assured that "screening benefit outweighs risk, across all individuals screened, not only those with lung cancer". An early non-invasive diagnosis of lung cancer would improve prognosis and enlarge treatment options. Analysis of exhaled breath would be an ideal diagnostic method, since it is non-invasive and totally painless. Methods: Exhaled breath and inhaled room air samples were analyzed using proton transfer reaction mass spectrometry (PTR-MS) and solid phase microextraction with subsequent gas chromatography mass spectrometry (SPME-GCMS). For the PTR-MS measurements, 220 lung cancer patients and 441 healthy volunteers were recruited. For the GCMS measurements, we collected samples from 65 lung cancer patients and 31 healthy volunteers. Lung cancer patients were in different disease stages and under treatment with different regimes. Mixed expiratory and indoor air samples were collected in Tedlar bags, and either analyzed directly by PTR-MS or transferred to glass vials and analyzed by gas chromatography mass spectrometry (GCMS). Only those measurements of compounds were considered, which showed at least a 15% higher concentration in exhaled breath than in indoor air. Compounds related to smoking behavior such as acetonitrile and benzene were not used to differentiate between lung cancer patients and healthy volunteers. Results: Isoprene, acetone and methanol are compounds appearing in everybody's exhaled breath. These three main compounds of exhaled breath show slightly lower concentrations in lung cancer patients as compared to healthy volunteers (p < 0.01 for isoprene and acetone, p = 0.011 for methanol; PTR-MS measurements). A comparison of the GCMS-results of 65 lung cancer patients with those of 31 healthy volunteers revealed differences in concentration for more than 50 compounds. Sensitivity for detection of lung cancer patients based on presence of (one of) 4 different compounds not arising in exhaled breath of healthy volunteers was 52% with a specificity of 100%. Using 15 (or 21) different compounds for distinction, sensitivity was 71% (80%) with a specificity of 100%. Potential marker compounds are alcohols, aldehydes, ketones and hydrocarbons. Conclusion: GCMS-SPME is a relatively insensitive method. Hence compounds not appearing in exhaled breath of healthy volunteers may be below the limit of detection (LOD). PTR-MS, on the other hand, does not need preconcentration and gives much more reliable quantitative results then GCMS-SPME. The shortcoming of PTR-MS is that it cannot identify compounds with certainty. Hence SPME-GCMS and PTR-MS complement each other, each method having its particular advantages and disadvantages. Exhaled breath analysis is promising to become a future non-invasive lung cancer screening method. In order to proceed towards this goal, precise identification of compounds observed in exhaled breath of lung cancer patients is necessary. Comparison with compounds released from lung cancer cell cultures, and additional information on exhaled breath composition in other cancer forms will be important.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solid phase microextraction with thermal desorption using fused silica optical fibers
Arthur, C. L., & Pawliszyn, J. (1990) · Analytical Chemistry · doi:10.1021/ac00218a019 · Cited by 4,997
Solid phase microextraction : theory and practice
Pawliszyn, J. B. (1997) · Medical Entomology and Zoology · Cited by 2,277
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Self-citationVolatile organic compounds in breath as markers of lung cancer: a cross-sectional study
Phillips, M., Gleeson, K., Hughes, J. M. B., Greenberg, J., Cataneo, R. N., Baker, L., & McVay, W. P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)07552-7 · Cited by 918
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801
Human exhaled air analytics: biomarkers of diseases
Buszewski, B., Kęsy, M., Ligor, T., & Amann, A. (2007) · Biomedical Chromatography · doi:10.1002/bmc.835 · Cited by 792
Self-citationLindinger, W., & Jordan, A. (1998) · Chemical Society Reviews · doi:10.1039/a827347z · Cited by 751
Variation in volatile organic compounds in the breath of normal humans
Phillips, M., Herrera, J., Krishnan, S., Zain, M., Greenberg, J., & Cataneo, R. N. (1999) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(99)00127-9 · Cited by 738
Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04294-u · Cited by 727
Cited by
Structural and Chemical Biology of Terpenoid Cyclases
Christianson, D. W. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00287 · Cited by 1,223
Carbon Nanotube Chemical Sensors
Schroeder, V., Savagatrup, S., He, M., Lin, S., & Swager, T. M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00340 · Cited by 1,131
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
“by Rudnicka et al [45], by Bajtarevic et al [7] and by Filipiak et al [12].”
BackgroundMethodSelf-citationVolatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Self-citationAmann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Self-citationPeng, G., Hakim, M., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., Tisch, U., & Haick, H. (2010) · British Journal of Cancer · doi:10.1038/sj.bjc.6605810 · Cited by 775
Assessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Self-citationSensors for Breath Testing: From Nanomaterials to Comprehensive Disease Detection
Konvalina, G., & Haick, H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400070m · Cited by 561
Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors
Righettoni, M., Amann, A., & Pratsinis, S. E. (2015) · Materials Today · doi:10.1016/j.mattod.2014.08.017 · Cited by 487
Self-citationReview—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Nondestructive Sampling of Living Systems Using in Vivo Solid-Phase Microextraction
Ouyang, G., Vuckovic, D., & Pawliszyn, J. (2011) · Chemical Reviews · doi:10.1021/cr100203t · Cited by 426
Breath Sensors for Health Monitoring
Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00937 · Cited by 410
Solid-state gas sensors for breath analysis: A review
Di Natale, C., Paolesse, R., Martinelli, E., & Capuano, R. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.014 · Cited by 365
The versatile use of exhaled volatile organic compounds in human health and disease
Boots, A. W., van Berkel, J. J. B. N., Dallinga, J. W., Smolinska, A., Wouters, E. F., & van Schooten, F. J. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/2/027108 · Cited by 352
A review of breath analysis for diagnosis of human health
Kim, K.-H., Jahan, S. A., & Kabir, E. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.09.013 · Cited by 345
Breath acetone monitoring by portable Si:WO3 gas sensors
Righettoni, M., Tricoli, A., Gass, S., Schmid, A., Amann, A., & Pratsinis, S. E. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.06.002 · Cited by 317
Self-citationIs breath acetone a biomarker of diabetes? A historical review on breath acetone measurements
Wang, Z., & Wang, C. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/3/037109 · Cited by 309
Breath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
VOC breath biomarkers in lung cancer
Saalberg, Y., & Wolff, M. (2016) · Clinica Chimica Acta · doi:10.1016/j.cca.2016.05.013 · Cited by 293
Hybrid Volatolomics and Disease Detection
Broza, Y. Y., Mochalski, P., Ruzsanyi, V., Amann, A., & Haick, H. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201500153 · Cited by 290
Self-citationExhaled breath analysis: a review of ‘breath-taking’ methods for off-line analysis
Lawal, O., Ahmed, W. M., Nijsen, T. M. E., Goodacre, R., & Fowler, S. J. (2017) · Metabolomics · doi:10.1007/s11306-017-1241-8 · Cited by 288
Drabińska, N., Flynn, C., Ratcliffe, N., Belluomo, I., Myridakis, A., Gould, O., Fois, M., Smart, A., Devine, T., & Costello, B. D. L. (2021) · Journal of Breath Research · doi:10.1088/1752-7163/abf1d0 · Cited by 288
Nanostructured Metal Oxide-Based Acetone Gas Sensors: A Review
Amiri, V., Roshan, H., Mirzaei, A., Neri, G., & Ayesh, A. I. (2020) · Sensors · doi:10.3390/s20113096 · Cited by 287
On-Line Analysis of Exhaled Breath: Focus Review
Bruderer, T., Gaisl, T., Gaugg, M. T., Nowak, N., Streckenbach, B., Müller, S., Moeller, A., Kohler, M., & Zenobi, R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00005 · Cited by 278
A nanomaterial-based breath test for distinguishing gastric cancer from benign gastric conditions
Xu, Z.-Q., Broza, Y. Y., Ionsecu, R., Tisch, U., Ding, L., Liu, H., Song, Q., Pan, Y.-Y., Xiong, F.-X., Gu, K.-S., et al. (2013) · British Journal of Cancer · doi:10.1038/bjc.2013.44 · Cited by 271
Filipiak, W., Sponring, A., Baur, M. M., Filipiak, A., Ager, C., Wiesenhofer, H., Nagl, M., Troppmair, J., & Amann, A. (2012) · BMC Microbiology · doi:10.1186/1471-2180-12-113 · Cited by 252
Self-citationClinical use of exhaled volatile organic compounds in pulmonary diseases: a systematic review
van de Kant, K. D., van der Sande, L. J., Jöbsis, Q., van Schayck, O. C., & Dompeling, E. (2012) · Respiratory Research · doi:10.1186/1465-9921-13-117 · Cited by 252
Mazzone, P. J., Wang, X.-F., Xu, Y., Mekhail, T., Beukemann, M. C., Na, J., Kemling, J. W., Suslick, K. S., & Sasidhar, M. (2012) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e318233d80f · Cited by 247
Wilson, A. (2015) · Metabolites · doi:10.3390/metabo5010140 · Cited by 242
Hanna, G. B., Boshier, P. R., Markar, S. R., & Romano, A. (2019) · JAMA Oncology · doi:10.1001/jamaoncol.2018.2815 · Cited by 237
Quartz-enhanced photoacoustic spectroscopy for multi-gas detection: A review
Sampaolo, A., Patimisco, P., Giglio, M., Zifarelli, A., Wu, H., Dong, L., & Spagnolo, V. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338894 · Cited by 229
Silicon Nanowire Sensors Enable Diagnosis of Patients via Exhaled Breath
Shehada, N., Cancilla, J. C., Torrecilla, J. S., Pariente, E. S., Brönstrup, G., Christiansen, S., Johnson, D. W., Leja, M., Davies, M. P. A., Liran, O., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b03127 · Cited by 227
Nanomaterial-based gas sensors used for breath diagnosis
Zhou, X., Xue, Z., Chen, X., Huang, C., Bai, W., Lu, Z., & Wang, T. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02518a · Cited by 227
The State of Molecular Biomarkers for the Early Detection of Lung Cancer
Hassanein, M., Callison, J. C., Callaway-Lane, C., Aldrich, M. C., Grogan, E. L., & Massion, P. P. (2012) · Cancer Prevention Research · doi:10.1158/1940-6207.capr-11-0441 · Cited by 215
Analysis of Exhaled Breath for Disease Detection
Amann, A., Miekisch, W., Schubert, J., Buszewski, B., Ligor, T., Jezierski, T., Pleil, J., & Risby, T. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020043 · Cited by 214
Self-citationDetection of precancerous gastric lesions and gastric cancer through exhaled breath
Amal, H., Leja, M., Funka, K., Skapars, R., Sivins, A., Ancans, G., Liepniece-Karele, I., Kikuste, I., Lasina, I., & Haick, H. (2016) · Gut · doi:10.1136/gutjnl-2014-308536 · Cited by 213
Sun, X., Shao, K., & Wang, T. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-9200-6 · Cited by 211
“2-Butanol, 2,3-dimethylGC–MS and PTR–MS [62]”
BackgroundInfluentialCurrent Challenges in Volatile Organic Compounds Analysis as Potential Biomarkers of Cancer
Schmidt, K., & Podmore, I. (2015) · Journal of Biomarkers · doi:10.1155/2015/981458 · Cited by 208
van der Schee, M. P., Paff, T., Brinkman, P., van Aalderen, W. M. C., Haarman, E. G., & Sterk, P. J. (2015) · Chest · doi:10.1378/chest.14-0781 · Cited by 203
Hanf, S., Keiner, R., Yan, D., Popp, J., & Frosch, T. (2014) · Analytical Chemistry · doi:10.1021/ac404162w · Cited by 200
Breath acetone as a potential marker in clinical practice
Ruzsányi, V., & Péter Kalapos, M. (2017) · Journal of Breath Research · doi:10.1088/1752-7163/aa66d3 · Cited by 195
Rudnicka, J., Kowalkowski, T., Ligor, T., & Buszewski, B. (2011) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.09.001 · Cited by 194
Self-citationKing, J., Mochalski, P., Kupferthaler, A., Unterkofler, K., Koc, H., Filipiak, W., Teschl, S., Hinterhuber, H., & Amann, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/008 · Cited by 189
Self-citationDetection of cancer through exhaled breath: a systematic review
Krilaviciute, A., Heiss, J. A., Leja, M., Kupcinskas, J., Haick, H., & Brenner, H. (2015) · Oncotarget · doi:10.18632/oncotarget.5938 · Cited by 188
“Also, two classification models on the same study population showed exactly same performance while including 4 [21] and 8 [22] VOCs.”
MethodThe application of statistical methods using VOCs to identify patients with lung cancer
Ulanowska, A., Kowalkowski, T., Trawińska, E., & Buszewski, B. (2011) · Journal of Breath Research · doi:10.1088/1752-7155/5/4/046008 · Cited by 183
Self-citationFilipiak, W., Filipiak, A., Sponring, A., Schmid, T., Zelger, B., Ager, C., Klodzinska, E., Denz, H., Pizzini, A., Lucciarini, P., et al. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/2/027111 · Cited by 173
“Furthermore, a link between 2-methylpentane and LC has already been shown [30, 31] who reported significantly higher concentration of this compound in the breath of NSCLC patients (compared to healthy controls).”
BackgroundSelf-citationBreathPrint: Breathing Acoustics-based User Authentication
Chauhan, J., Hu, Y., Seneviratne, S., Misra, A., Seneviratne, A., & Lee, Y. (2017) · Proceedings of the 15th Annual International Conference on Mobile Systems, Applications, and Services · doi:10.1145/3081333.3081355 · Cited by 170
Kumar, S., Huang, J., Abbassi-Ghadi, N., Španěl, P., Smith, D., & Hanna, G. B. (2013) · Analytical Chemistry · doi:10.1021/ac4010309 · Cited by 164
Lung cancer biomarkers in exhaled breath
Amann, A., Corradi, M., Mazzone, P., & Mutti, A. (2011) · Expert Review of Molecular Diagnostics · doi:10.1586/erm.10.112 · Cited by 163
Self-citationEmission rates of selected volatile organic compounds from skin of healthy volunteers
Mochalski, P., King, J., Unterkofler, K., Hinterhuber, H., & Amann, A. (2014) · Journal of Chromatography B · doi:10.1016/j.jchromb.2014.04.006 · Cited by 163
Self-citationLubes, G., & Goodarzi, M. (2018) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2017.07.013 · Cited by 162
Solid-phase microextraction in metabolomics
Bojko, B., Reyes-Garcés, N., Bessonneau, V., Goryński, K., Mousavi, F., Souza Silva, E. A., & Pawliszyn, J. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.07.005 · Cited by 161
Taking your breath away: metabolomics breathes life in to personalized medicine
Rattray, N. J. W., Hamrang, Z., Trivedi, D. K., Goodacre, R., & Fowler, S. J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.08.003 · Cited by 160
Breathomics for the clinician: the use of volatile organic compounds in respiratory diseases
Ibrahim, W., Carr, L., Cordell, R., Wilde, M. J., Salman, D., Monks, P. S., Thomas, P., Brightling, C. E., Siddiqui, S., & Greening, N. J. (2021) · Thorax · doi:10.1136/thoraxjnl-2020-215667 · Cited by 115
Binson, V. A., & Subramoniam, M. (2022) · Journal of Biomimetics, Biomaterials and Biomedical Engineering · doi:10.4028/p-dab04j · Cited by 14
Metadata
- Authors
- Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Schwarz, K., Ligor, M., Ligor, T., Filipiak, W., Denz, H., Fiegl, M., Hilbe, W., Weiss, W., Lukas, P., Jamnig, H., Hackl, M., Haidenberger, A., Buszewski, B., Miekisch, W., Schubert, J., & Amann, A.
- Venue
- BMC Cancer
- Published
- 2009-09-29
- Volume
- 9
- Issue
- 1
- Pages
- 348-348
- ISSN
- 1471-2407 (ISSN-L)
- OpenAlex
- W2148765323
- Cited by
- 597
- References
- 53
- FWCI
- 16.89
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.