Pedometer Measures of Free-Living Physical Activity: Comparison of 13 Models
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
PURPOSE: The purpose of this study was to compare the step values of multiple brands of pedometers over a 24-h period. The following 13 electronic pedometers were assessed in the study: Accusplit Alliance 1510 (AC), Freestyle Pacer Pro (FR), Colorado on the Move (CO), Kenz Lifecorder (KZ), New-Lifestyles NL-2000 (NL), Omron HJ-105 (OM), Oregon Scientific PE316CA (OR), Sportline 330 (SL330) and 345 (SL345), Walk4Life LS 2525 (WL), Yamax Skeletone EM-180 (SK), Yamax Digi-Walker SW-200 (YX200), and the Yamax Digi-Walker SW-701 (YX701). METHODS: Ten males (39.5 +/- 16.6 yr, mean +/- SD) and 10 females (43.3 +/- 16.6 yr) ranging in BMI from 19.8 to 35.4 kg.m-2 wore two pedometers for a 24-h period. The criterion pedometer (YX200) was worn on the left side of the body, and a comparison pedometer was worn on the right. Steps counted by each device were recorded at the end of the day for each of the thirteen pedometers. RESULTS: Subjects took an average of 9244 steps.d-1. The KZ, YX200, NL, YX701, and SL330 yielded mean values that were not significantly different from the criterion. The FR, AC, SK, CO, and SL345 significantly underestimated steps (P < 0.05) and the WL, OM, and OR significantly overestimated steps (P < 0.05) when compared with the criterion. In addition, some pedometers underestimated by 25% whereas others overestimated by 45%. CONCLUSION: The KZ, YX200, NL, and YX701 appear to be suitable for most research purposes. Given the potential for pedometers in physical activity research, it is necessary that there be consistency across studies in the measurement of "steps per day."
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Obesity and the Environment: Where Do We Go from Here?
Hill, J. O., Wyatt, H. R., Reed, G. W., & Peters, J. C. (2003) · Science · doi:10.1126/science.1079857 · Cited by 2,180
How Many Steps/Day Are Enough?: Preliminary Pedometer Indices for Public Health
Tudor-Locke, C., & Bassett, D. R. (2004) · Sports Medicine · doi:10.2165/00007256-200434010-00001 · Cited by 2,054
Self-citationPHYSICAL ACTIVITY AS AN INDEX OF HEART ATTACK RISK IN COLLEGE ALUMNI1
PAFFENBARGER, R. S., WING, A. L., & HYDE, R. T. (1978) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a112608 · Cited by 1,980
Research Methods in Physical Activity
Thomas, J. R., & Nelson, J. K. (1990) · Cited by 1,562
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899
Self-citationGrace, S. L., Abbey, S. E., Shnek, Z. M., Irvine, J., Franche, R.-L., & Stewart, D. E. (2002) · General Hospital Psychiatry · doi:10.1016/s0163-8343(02)00179-2 · Cited by 685
Accuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m Walk
SCHNEIDER, P. L., CROUTER, S. E., LUKAJIC, O., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000089342.96098.c4 · Cited by 633
Self-citationMeasuring Physical Activity and Energy Expenditure
Kemper, H. C. G., & Saris, W. H. M. (1996) · Cited by 554
Accuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Self-citation
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Using mobile phones to determine transportation modes
Reddy, S., Mun, M., Burke, J., Estrin, D., Hansen, M., & Srivastava, M. (2010) · ACM Transactions on Sensor Networks · doi:10.1145/1689239.1689243 · Cited by 852
Accuracy of Smartphone Applications and Wearable Devices for Tracking Physical Activity Data
Case, M. A., Burwick, H. A., Volpp, K. G., & Patel, M. S. (2015) · JAMA · doi:10.1001/jama.2014.17841 · Cited by 694
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
“We focused our interpretation of measurement accuracy based on predefined acceptable limits for measurement accuracy in controlled settings as a percentage difference of ±3% and acceptable limits for relative accuracy in free-living settings as a percentage difference of ±10% [19-22].”
MethodWarren, J. M., Ekelund, U., Besson, H., Mezzani, A., Geladas, N., & Vanhees, L. (2010) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e32832ed875 · Cited by 587
Assessment of Physical Activity and Energy Expenditure: An Overview of Objective Measures
Hills, A. P., Mokhtar, N., & Byrne, N. M. (2014) · Frontiers in Nutrition · doi:10.3389/fnut.2014.00005 · Cited by 575
Integrating Physical Activity Into Mental Health Services for Persons With Serious Mental Illness
Richardson, C. R., Faulkner, G., McDevitt, J., Skrinar, G. S., Hutchinson, D. S., & Piette, J. D. (2005) · Psychiatric Services · doi:10.1176/appi.ps.56.3.324 · Cited by 493
How many days of pedometer monitoring predict weekly physical activity in adults?
TUDORLOCKE, C., BURKETT, L., REIS, J., AINSWORTH, B., MACERA, C., & WILSON, D. (2005) · Preventive Medicine · doi:10.1016/j.ypmed.2004.06.003 · Cited by 479
Quantifying physical activity in daily life with questionnaires and motion sensors in COPD
Pitta, F., Troosters, T., Probst, V. S., Spruit, M. A., Decramer, M., & Gosselink, R. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00064105 · Cited by 473
How many days of monitoring predict physical activity and sedentary behaviour in older adults?
Hart, T. L., Swartz, A. M., Cashin, S. E., & Strath, S. J. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-62 · Cited by 473
Translating Physical Activity Recommendations into a Pedometer-Based Step Goal
Marshall, S. J., Levy, S. S., Tudor-Locke, C. E., Kolkhorst, F. W., Wooten, K. M., Ji, M., Macera, C. A., & Ainsworth, B. E. (2009) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2009.01.021 · Cited by 447
Pedometer-Measured Physical Activity and Health Behaviors in U.S. Adults
BASSETT, D. R., WYATT, H. R., THOMPSON, H., PETERS, J. C., & HILL, J. O. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181dc2e54 · Cited by 411
Self-citationDowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“Various approaches were used to examine the concurrent validity of pedometers, with 14 studies comparing pedometer step count with steps determined from other pedometers [432, 451, 458] and activity monitors [77, 298, 391, 422, 433, 434, 444, 455– 457, 459] and 4 studies comparing pedometer determined energy expenditu…”
MethodPrescribing exercise as preventive therapy
Warburton, D. E. R. (2006) · Canadian Medical Association Journal · doi:10.1503/cmaj.1040750 · Cited by 374
Accelerometers and pedometers: methodology and clinical application
Corder, K., Brage, S., & Ekelund, U. (2007) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/mco.0b013e328285d883 · Cited by 339
Reliability and Validity of the IPAQ-Chinese: The Guangzhou Biobank Cohort Study
DENG, H. B., MACFARLANE, D. J., THOMAS, G. N., LAO, X. Q., JIANG, C. Q., CHENG, K. K., & LAM, T. H. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815b0db5 · Cited by 319
Physical Activity in Preschoolers: Understanding Prevalence and Measurement Issues
Oliver, M., Schofield, G. M., & Kolt, G. S. (2007) · Sports Medicine · doi:10.2165/00007256-200737120-00004 · Cited by 315
Activity-Monitor Accuracy in Measuring Step Number and Cadence in Community-Dwelling Older Adults
Grant, P. M., Dall, P. M., Mitchell, S. L., & Granat, M. H. (2008) · Journal of Aging and Physical Activity · doi:10.1123/japa.16.2.201 · Cited by 297
“The SW-200 was used as the criterion pedometer in a previous study (Schneider et al., 2004) and, irrespective of body-mass index, was found to be accurate in measuring step numbers in healthy young adults walking on a treadmill at speeds in excess of 1.33 m/s (Swartz et al., 2003) and walking…”
MethodInfluentialSpring-Levered versus Piezo-Electric Pedometer Accuracy in Overweight and Obese Adults
CROUTER, S. E., SCHNEIDER, P. L., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000181677.36658.a8 · Cited by 295
Self-citationSafe To Walk? Neighborhood Safety and Physical Activity Among Public Housing Residents
Bennett, G. G., McNeill, L. H., Wolin, K. Y., Duncan, D. T., Puleo, E., & Emmons, K. M. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040306 · Cited by 295
Impact of preschool environment upon children's physical activity and sun exposure
Boldemann, C., Blennow, M., Dal, H., Mårtensson, F., Raustorp, A., Yuen, K., & Wester, U. (2006) · Preventive Medicine · doi:10.1016/j.ypmed.2005.12.006 · Cited by 290
Validity and Reliability of the Global Physical Activity Questionnaire (GPAQ)
Herrmann, S. D., Heumann, K. J., Der Ananian, C. A., & Ainsworth, B. E. (2013) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2013.805139 · Cited by 240
de Blok, B. M. J., de Greef, M. H. G., ten Hacken, N. H. T., Sprenger, S. R., Postema, K., & Wempe, J. B. (2006) · Patient Education and Counseling · doi:10.1016/j.pec.2005.02.005 · Cited by 231
“Subsequently, the SW-200 pedometer was found to be 1 of the 4 models (among 13) that accurately measures steps taken during free-living physical activity [22].”
MethodValidity and Reliability of the International Physical Activity Questionnaire in College Students
Dinger, M. K., Behrens, T. K., & Han, J. L. (2006) · American Journal of Health Education · doi:10.1080/19325037.2006.10598924 · Cited by 222
Using Activity Monitors to Measure Physical Activity in Free-Living Conditions
Berlin, J. E., Storti, K. L., & Brach, J. S. (2006) · Physical Therapy · doi:10.1093/ptj/86.8.1137 · Cited by 209
Tudor-Locke, C., & Lutes, L. (2009) · Sports Medicine · doi:10.2165/11319600-000000000-00000 · Cited by 209
Silva, M. N., Markland, D., Minderico, C. S., Vieira, P. N., Castro, M. M., Coutinho, S. R., Santos, T. C., Matos, M. G., Sardinha, L. B., & Teixeira, P. J. (2008) · BMC Public Health · doi:10.1186/1471-2458-8-234 · Cited by 207
“This pedometer is a highly accurate and a reliable step counter and is effective for both walking and running [40,41].”
Daily Step Target to Measure Adherence to Physical Activity Guidelines in Children
COLLEY, R. C., JANSSEN, I., & TREMBLAY, M. S. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31823f23b1 · Cited by 206
Hajna, S., Ross, N. A., Brazeau, A.-S., Bélisle, P., Joseph, L., & Dasgupta, K. (2015) · BMC Public Health · doi:10.1186/s12889-015-2082-x · Cited by 192
“that have been validated for use in adults [36–42].”
MethodIntegrated behavioral health in primary care: Step-by-step guidance for assessment and intervention.
Hunter, C. L., Goodie, J. L., Oordt, M. S., & Dobmeyer, A. C. (2017) · American Psychological Association eBooks · doi:10.1037/0000017-000 · Cited by 190
Expected values for steps/day in special populations
Tudor-Locke, C., Washington, T. L., & Hart, T. L. (2009) · Preventive Medicine · doi:10.1016/j.ypmed.2009.04.012 · Cited by 178
“The Yamax pedometer is considered a criterion research quality pedometer (Schneider et al., 2004), the Lifecorder's validity is well documented (Crouter et al.”
Methodon behalf of the DEDIPAC consortium, Van Hecke, L., Loyen, A., Verloigne, M., van der Ploeg, H. P., Lakerveld, J., Brug, J., De Bourdeaudhuij, I., Ekelund, U., Donnelly, A., et al. (2016) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-016-0396-4 · Cited by 173
“For example, consensus still has to be reached regarding the accuracy of steps recorded by different pedometers [12], as well as the specific accelerometer intensity thresholds [11, 13] that correspond with low intensity physical activity (LPA), MVPA or VPA in youth.”
Verloigne, M., Loyen, A., Van Hecke, L., Lakerveld, J., Hendriksen, I., De Bourdheaudhuij, I., Deforche, B., Donnelly, A., Ekelund, U., Brug, J., et al. (2016) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-016-0395-5 · Cited by 175
Number of Pedometer-Assessed Steps Taken Per Day by Adults: A Descriptive Meta-Analysis
Bohannon, R. W. (2007) · Physical Therapy · doi:10.2522/ptj.20060037 · Cited by 174
“Meta-analysis is an alternative approach in which individual studies addressing a common issue are statistically combined to arrive at a conclusion about the body of research.53,54 Meta-analysis provides the opportunity to: (1) increase power for primary outcomes and subgroup analysis, ( 2 ) help resolve uncertainty w…”
BackgroundMethodInfluentialCombined Influence of Physical Activity and Screen Time Recommendations on Childhood Overweight
Laurson, K. R., Eisenmann, J. C., Welk, G. J., Wickel, E. E., Gentile, D. A., & Walsh, D. A. (2008) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2008.02.042 · Cited by 173
“These recommendaions are usually formed based on a combination of expert opinion and existing evidence.(8) ut the initial risk of a child meeting or not meeting a recommendation or clinical utpoint should be assessed to provide an indication of the utility of the cutpoint.”
BackgroundCan implementation intentions and text messages promote brisk walking? A randomized trial.
Prestwich, A., Perugini, M., & Hurling, R. (2010) · Health Psychology · doi:10.1037/a0016993 · Cited by 158
Lee, J. A., Williams, S. M., Brown, D. D., & Laurson, K. R. (2015) · Journal of Sports Sciences · doi:10.1080/02640414.2014.981848 · Cited by 169
“However, the present study utilised the YX, which is commonly used in free-living settings as a referent monitor for counting steps (Schneider et al., 2004), and selected a sample that the YX accurately estimates step counts in Crouter et al.”
MethodResultInfluentialHospes, G., Bossenbroek, L., ten Hacken, N. H. T., van Hengel, P., & de Greef, M. H. G. (2009) · Patient Education and Counseling · doi:10.1016/j.pec.2008.10.005 · Cited by 169
“Pedometers are also key in triggering enhancement of daily physical activity [9–12].”
BackgroundThe Accuracy of Pedometer Steps and Time during Walking in Children
BEETS, M. W., PATTON, M. M., & EDWARDS, S. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000155395.49960.31 · Cited by 166
Position-sensing technologies for movement analysis in stroke rehabilitation
Zheng, H., Black, N. D., & Harris, N. D. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344720 · Cited by 165
“…have been successfully applied in the measurement of physical activity in free-living populations (BALOGH et al., 2004; BASSETT et al., 2000; CROTEAU, 2004; GROVES, 1988; HOODLESS et al., 1994; SAGAWA et al., 2000; SCHNEIDER et al., 2004; SEQUEIRA et al., 1995; STEELE et al., 2003; TALBOT, 2003).”
MethodEffects of abdominal massage in management of constipation—A randomized controlled trial
Lämås, K., Lindholm, L., Stenlund, H., Engström, B., & Jacobsson, C. (2009) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.01.007 · Cited by 165
“The Yamax pedometers are considered to be suitable for research (Schneider et al., 2004; Tudor-Locke et al., 2006).”
BackgroundGapin, J., & Etnier, J. L. (2010) · Journal of Sport and Exercise Psychology · doi:10.1123/jsep.32.6.753 · Cited by 160
Nocturnal non-invasive ventilation in addition to rehabilitation in hypercapnic patients with COPD
Duiverman, M. L., Wempe, J. B., Bladder, G., Jansen, D. F., Kerstjens, H. A. M., Zijlstra, J. G., & Wijkstra, P. J. (2008) · Thorax · doi:10.1136/thx.2008.099044 · Cited by 158
Video-Recorded Validation of Wearable Step Counters under Free-living Conditions
TOTH, L. P., PARK, S., SPRINGER, C. M., FEYERABEND, M. D., STEEVES, J. A., & BASSETT, D. R. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001569 · Cited by 154
Self-citationAltenburg, W. A., ten Hacken, N. H. T., Bossenbroek, L., Kerstjens, H. A. M., de Greef, M. H. G., & Wempe, J. B. (2015) · Respiratory Medicine · doi:10.1016/j.rmed.2014.10.020 · Cited by 143
“Physical activity was assessed in all patients in daily steps using a pedometer (Digiwalker SW-2000, Yamax; Tokyo Japan) and in daily physical activity [19].”
MethodÉvaluation de la qualité des podomètres commerciaux
Tudor-Locke, C., Sisson, S. B., Lee, S. M., Craig, C. L., Plotnikoff, R. C., & Bauman, A. (2006) · Canadian Journal of Public Health · doi:10.1007/bf03405359 · Cited by 142
Tedesco, S., Sica, M., Ancillao, A., Timmons, S., Barton, J., & O'Flynn, B. (2019) · JMIR mHealth and uHealth · doi:10.2196/13084 · Cited by 139
“Some studies recommend that an acceptable measurement error under controlled conditions or for research purposes is within ±3% [41,42] and under free-living conditions is within ±10% [41,42].”
BackgroundComparison of two waist-mounted and two ankle-mounted electronic pedometers
Karabulut, M., Crouter, S. E., & Bassett, D. R. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0018-3 · Cited by 139
Self-citationA Persuasive and Social mHealth Application for Physical Activity: A Usability and Feasibility Study
Al Ayubi, S. U., Parmanto, B., Branch, R., & Ding, D. (2014) · JMIR mHealth and uHealth · doi:10.2196/mhealth.2902 · Cited by 108
Reactivity: an issue for short-term pedometer studies?: Figure 1
Clemes, S. A., Matchett, N., & Wane, S. L. (2008) · British Journal of Sports Medicine · doi:10.1136/bjsm.2007.038521 · Cited by 106
Furlanetto, K. C., Bisca, G. W., Oldemberg, N., Sant'Anna, T. J., Morakami, F. K., Camillo, C. A., Cavalheri, V., Hernandes, N. A., Probst, V. S., Ramos, E. M., et al. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.10.024 · Cited by 87
Time Trends for Step-Determined Physical Activity among Japanese Adults
INOUE, S., OHYA, Y., TUDOR-LOCKE, C., TANAKA, S., YOSHIIKE, N., & SHIMOMITSU, T. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31821a5225 · Cited by 81
Duncan, M. J., Wunderlich, K., Zhao, Y., & Faulkner, G. (2018) · Journal of Sports Sciences · doi:10.1080/02640414.2017.1409855 · Cited by 76
Tierney, M., Fraser, A., Purtill, H., & Kennedy, N. (2013) · Arthritis Care & Research · doi:10.1002/acr.21914 · Cited by 56
Vanroy, C., Vissers, D., Cras, P., Beyne, S., Feys, H., Vanlandewijck, Y., & Truijen, S. (2014) · Disability and Rehabilitation · doi:10.3109/09638288.2013.859307 · Cited by 46
Effects of Body Mass Index and Step Rate on Pedometer Error in a Free-Living Environment
TYO, B. M., FITZHUGH, E. C., BASSETT, D. R., JOHN, D., FEITO, Y., & THOMPSON, D. L. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e9b133 · Cited by 46
Self-citationFour-week pedometer-determined activity patterns in normal weight and overweight UK adults
Clemes, S. A., Griffiths, P. L., & Hamilton, S. L. (2007) · International Journal of Obesity · doi:10.1038/sj.ijo.0803420 · Cited by 36
Dasgupta, K., Hajna, S., Joseph, L., Da Costa, D., Christopoulos, S., & Gougeon, R. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-125 · Cited by 32
The Impact of Different Degrees of Feedback on Physical Activity Levels: A 4-Week Intervention Study
Van Hoye, K., Boen, F., & Lefevre, J. (2015) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph120606561 · Cited by 30
“Previous research has identified this pedometer as one of the most accurate and reliable electronic pedometers available [33,34].”
Baran, J., Weres, A., Wyszyńska, J., Pitucha, G., Czenczek-Lewandowska, E., Rusek, W., Leszczak, J., & Mazur, A. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17238918 · Cited by 30
Giansanti, D., Maccioni, G., & Morelli, S. (2008) · Telemedicine and e-Health · doi:10.1089/tmj.2007.0078 · Cited by 27
(2007) · Cited by 25
Inoue, S., Ohya, Y., Tudor-Locke, C., Yoshiike, N., & Shimomitsu, T. (2012) · Journal of Physical Activity and Health · doi:10.1123/jpah.9.8.1117 · Cited by 23
Southard, V., & Gallagher, R. (2013) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e318264b5e8 · Cited by 18
Metadata
- Authors
- SCHNEIDER, P. L., CROUTER, S. E., & BASSETT, D. R.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2004-02
- Volume
- 36
- Issue
- 2
- Pages
- 331-335
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2030299181
- Cited by
- 752
- References
- 20
- FWCI
- 18.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.