The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Ion Suppression in Mass Spectrometry
Abstract
Background: Mass spectrometry (MS) is being introduced into a large number of clinical laboratories. It provides specificity because of its ability to monitor selected mass ions, sensitivity because of the enhanced signal-to-noise ratio, and speed because it can help avoid the need for intensive sample cleanup and long analysis times. However, MS is not without problems related to interference, especially through ion suppression effects. Ion suppression results from the presence of less volatile compounds that can change the efficiency of droplet formation or droplet evaporation, which in turn affects the amount of charged ion in the gas phase that ultimately reaches the detector. Content: This review discusses materials shown to cause ion suppression, including salts, ion-pairing agents, endogenous compounds, drugs, metabolites, and proteins. Experimental protocols for examining ion suppression, which should include, at a minimum, signal recovery studies using specimen extracts with added analyte, are also discussed, and a more comprehensive approach is presented that uses postcolumn infusion of the analyte to evaluate protracted ionization effects. Finally, this review presents options for minimizing or correcting ion suppression, which include enhanced specimen cleanup, chromatographic changes, reagent modifications, and effective internal standardization. Summary: Whenever mass spectrometric assays are developed, ion suppression studies should be performed using expected physiologic concentrations of the analyte under investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanistic investigation of ionization suppression in electrospray ionization
King, R., Bonfiglio, R., Fernandez-Metzler, C., Miller-Stein, C., & Olah, T. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00163-x · Cited by 1,086
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (1998) · Analytical Chemistry · doi:10.1021/ac971078+ · Cited by 880
Apffel, A., Fischer, S., Goldberg, G., Goodley, P. C., & Kuhlmann, F. E. (1995) · Journal of Chromatography A · doi:10.1016/0021-9673(95)00175-m · Cited by 344
The Dominance of Arginine-Containing Peptides in MALDI-Derived Tryptic Mass Fingerprints of Proteins
Krause, E., Wenschuh, H., & Jungblut, P. R. (1999) · Analytical Chemistry · doi:10.1021/ac990298f · Cited by 287
Müller, C., Schäfer, P., Störtzel, M., Vogt, S., & Weinmann, W. (2002) · Journal of Chromatography B · doi:10.1016/s1570-0232(02)00142-3 · Cited by 253
Gharahdaghi, F., Kirchner, M., Fernandez, J., & Mische, S. M. (1996) · Analytical Biochemistry · doi:10.1006/abio.1996.0012 · Cited by 110
Eshraghi, J., & Chowdhury, S. K. (1993) · Analytical Chemistry · doi:10.1021/ac00071a035 · Cited by 104
Sterner, J. L., Johnston, M. V., Nicol, G. R., & Ridge, D. P. (2000) · Journal of Mass Spectrometry · Cited by 99
Bruins, C. H. P., Jeronimus‐Stratingh, C. M., Ensing, K., van Dongen, W. D., & de Jong, G. J. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00959-0 · Cited by 51
Cited by
Peters, F. T., Drummer, O. H., & Musshoff, F. (2007) · Forensic Science International · doi:10.1016/j.forsciint.2006.05.021 · Cited by 1,343
Taylor, P. J. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.11.007 · Cited by 1,248
Alseekh, S., Aharoni, A., Brotman, Y., Contrepois, K., D’Auria, J., Ewald, J., C. Ewald, J., Fraser, P. D., Giavalisco, P., Hall, R. D., et al. (2021) · Nature Methods · doi:10.1038/s41592-021-01197-1 · Cited by 1,128
An overview of matrix effects in liquid chromatography–mass spectrometry
Trufelli, H., Palma, P., Famiglini, G., & Cappiello, A. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20298 · Cited by 811
Deuterium‐ and Tritium‐Labelled Compounds: Applications in the Life Sciences
Atzrodt, J., Derdau, V., Kerr, W. J., & Reid, M. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201704146 · Cited by 810
Validation of bioanalytical LC–MS/MS assays: Evaluation of matrix effects
Van Eeckhaut, A., Lanckmans, K., Sarre, S., Smolders, I., & Michotte, Y. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.01.003 · Cited by 763
Reproducible molecular networking of untargeted mass spectrometry data using GNPS
Aron, A. T., Gentry, E. C., McPhail, K. L., Nothias, L.-F., Nothias-Esposito, M., Bouslimani, A., Petras, D., Gauglitz, J. M., Sikora, N., Vargas, F., et al. (2020) · Nature Protocols · doi:10.1038/s41596-020-0317-5 · Cited by 725
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry
Gosetti, F., Mazzucco, E., Zampieri, D., & Gennaro, M. C. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.060 · Cited by 680
Hebert, A. S., Richards, A. L., Bailey, D. J., Ulbrich, A., Coughlin, E. E., Westphall, M. S., & Coon, J. J. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.034769 · Cited by 528
The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry
Hoofnagle, A. N., & Wener, M. H. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2009.06.003 · Cited by 561
Ion suppression; A critical review on causes, evaluation, prevention and applications
Furey, A., Moriarty, M., Bane, V., Kinsella, B., & Lehane, M. (2013) · Talanta · doi:10.1016/j.talanta.2013.03.048 · Cited by 521
Quantification of protein modification by oxidants
Hawkins, C. L., Morgan, P. E., & Davies, M. J. (2009) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2009.01.007 · Cited by 487
Genome-Scale Proteomics Reveals Arabidopsis thaliana Gene Models and Proteome Dynamics
Baerenfaller, K., Grossmann, J., Grobei, M. A., Hull, R., Hirsch-Hoffmann, M., Yalovsky, S., Zimmermann, P., Grossniklaus, U., Gruissem, W., & Baginsky, S. (2008) · Science · doi:10.1126/science.1157956 · Cited by 484
Metabolite Measurement: Pitfalls to Avoid and Practices to Follow
Lu, W., Su, X., Klein, M. S., Lewis, I. A., Fiehn, O., & Rabinowitz, J. D. (2017) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-061516-044952 · Cited by 462
Lindberg, R., Jarnheimer, P.-Å., Olsen, B., Johansson, M., & Tysklind, M. (2004) · Chemosphere · doi:10.1016/j.chemosphere.2004.09.015 · Cited by 455
Liu, X., & Locasale, J. W. (2017) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2017.01.004 · Cited by 453
Wu, L., Mashego, M. R., van Dam, J. C., Proell, A. M., Vinke, J. L., Ras, C., van Winden, W. A., van Gulik, W. M., & Heijnen, J. J. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2004.09.001 · Cited by 421
Measuring cortisol in serum, urine and saliva—Are our assays good enough?
El-Farhan, N., Rees, D. A., & Evans, C. (2017) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/0004563216687335 · Cited by 395
Nelson, R. E., Grebe, S. K., O’Kane, D. J., & Singh, R. J. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.025478 · Cited by 359
Kuehnbaum, N. L., & Britz-McKibbin, P. (2013) · Chemical Reviews · doi:10.1021/cr300484s · Cited by 354
Vidova, V., & Spacil, Z. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.01.059 · Cited by 352
The MALDI-TOF Mass Spectrometric View of the Plasma Proteome and Peptidome
Hortin, G. L. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2006.069252 · Cited by 351
Review on metabolomics for food authentication
Cubero-Leon, E., Peñalver, R., & Maquet, A. (2014) · Food Research International · doi:10.1016/j.foodres.2013.11.041 · Cited by 334
Wallace, A. M., Gibson, S., de la Hunty, A., Lamberg-Allardt, C., & Ashwell, M. (2010) · Steroids · doi:10.1016/j.steroids.2010.02.012 · Cited by 311
Wang, M., Wang, C., & Han, X. (2017) · Mass Spectrometry Reviews · doi:10.1002/mas.21492 · Cited by 301
Strategies for analysis of glycoprotein glycosylation
Geyer, H., & Geyer, R. (2006) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2006.10.007 · Cited by 299
A new ESI-LC/MS approach for comprehensive metabolic profiling of phytocannabinoids in Cannabis
Berman, P., Futoran, K., Lewitus, G. M., Mukha, D., Benami, M., Shlomi, T., & Meiri, D. (2018) · Scientific Reports · doi:10.1038/s41598-018-32651-4 · Cited by 292
Vogeser, M., & Seger, C. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.138602 · Cited by 290
Advances in Urinary Proteome Analysis and Biomarker Discovery
Fliser, D., Novak, J., Thongboonkerd, V., Argile[Combining Acute Accent]s, A. G. A., Jankowski, V., Girolami, M. A., Jankowski, J., & Mischak, H. (2007) · Journal of the American Society of Nephrology · doi:10.1681/asn.2006090956 · Cited by 286
Kushnir, M. M., Blamires, T., Rockwood, A. L., Roberts, W. L., Yue, B., Erdogan, E., Bunker, A. M., & Meikle, A. W. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.143222 · Cited by 283
Cortese, M., Gigliobianco, M. R., Magnoni, F., Censi, R., & Di Martino, P. (2020) · Molecules · doi:10.3390/molecules25133047 · Cited by 280
Advantages and challenges of mass spectrometry assays for steroid hormones
Stanczyk, F. Z., & Clarke, N. J. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.05.001 · Cited by 265
Metabolomic approaches toward understanding nitrogen metabolism in plants
Kusano, M., Fukushima, A., Redestig, H., & Saito, K. (2011) · Journal of Experimental Botany · doi:10.1093/jxb/erq417 · Cited by 259
Current role of liquid chromatography–mass spectrometry in clinical and forensic toxicology
Maurer, H. H. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1248-5 · Cited by 257
Overcoming Matrix Effects in Liquid Chromatography−Mass Spectrometry
Cappiello, A., Famiglini, G., Palma, P., Pierini, E., Termopoli, V., & Trufelli, H. (2008) · Analytical Chemistry · doi:10.1021/ac8018312 · Cited by 253
Dysregulation of lipids in Alzheimer’s disease and their role as potential biomarkers
Wong, M. W., Braidy, N., Poljak, A., Pickford, R., Thambisetty, M., & Sachdev, P. S. (2017) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2017.01.008 · Cited by 223
Rauh, M., Gröschl, M., Rascher, W., & Dörr, H. G. (2006) · Steroids · doi:10.1016/j.steroids.2006.01.015 · Cited by 170
Ehrenshaft, M., Deterding, L. J., & Mason, R. P. (2015) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2015.08.003 · Cited by 158
Draper, J., Lloyd, A. J., Goodacre, R., & Beckmann, M. (2013) · Metabolomics · doi:10.1007/s11306-012-0449-x · Cited by 144
Yue, B., Rockwood, A. L., Sandrock, T., La’ulu, S. L., Kushnir, M. M., & Meikle, A. W. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.098293 · Cited by 127
Standardization of testosterone measurements in humans
Vesper, H. W., & Botelho, J. C. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.03.032 · Cited by 113
Wu, C., Xiong, W., Dai, J., & Wu, Q. (2015) · Plant Physiology · doi:10.1104/pp.114.250688 · Cited by 108
Carvalho, V. M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.08.027 · Cited by 90
Ray, J. A., Kushnir, M. M., Yost, R. A., Rockwood, A. L., & Wayne Meikle, A. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.07.036 · Cited by 88
Mass spectrometry and 3‐nitrotyrosine: Strategies, controversies, and our current perspective
Tsikas, D., & Duncan, M. W. (2014) · Mass Spectrometry Reviews · doi:10.1002/mas.21396 · Cited by 76
Janzen, N., Sander, S., Terhardt, M., Steuerwald, U., Peter, M., Das, A. M., & Sander, J. (2011) · Steroids · doi:10.1016/j.steroids.2011.07.013 · Cited by 66
Johnsen, E., Leknes, S., Wilson, S. R., & Lundanes, E. (2015) · Scientific Reports · doi:10.1038/srep09308 · Cited by 65
Empirical evaluation of bone extraction protocols
Cleland, T. P., Voegele, K., & Schweitzer, M. H. (2012) · PLoS ONE · doi:10.1371/journal.pone.0031443 · Cited by 60
Turgeon, C. T., Moser, A. B., Mørkrid, L., Magera, M. J., Gavrilov, D. K., Oglesbee, D., Raymond, K., Rinaldo, P., Matern, D., & Tortorelli, S. (2015) · Molecular Genetics and Metabolism · doi:10.1016/j.ymgme.2014.11.013 · Cited by 60
Hoofnagle, A. N. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.134049 · Cited by 57
Multi-steroid profiling by UHPLC-MS/MS with post-column infusion of ammonium fluoride
Schiffer, L., Shaheen, F., Gilligan, L. C., Storbeck, K.-H., Hawley, J. M., Keevil, B. G., Arlt, W., & Taylor, A. E. (2022) · Journal of Chromatography B · doi:10.1016/j.jchromb.2022.123413 · Cited by 52
Barco, S., Bandettini, R., Maffia, A., Tripodi, G., Castagnola, E., & Cangemi, G. (2015) · Journal of Chemotherapy · doi:10.1179/1973947814y.0000000209 · Cited by 46
Nardin, T., Barnaba, C., Abballe, F., Trenti, G., Malacarne, M., & Larcher, R. (2017) · Journal of Separation Science · doi:10.1002/jssc.201700579 · Cited by 37
Hawley, J. M., Owen, L. J., MacKenzie, F., Mussell, C., Cowen, S., & Keevil, B. G. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.243576 · Cited by 36
Metadata
- Authors
- Annesley, T. M.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-07-01
- Volume
- 49
- Issue
- 7
- Pages
- 1041-1044
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2140695271
- Cited by
- 1,591
- References
- 10
- FWCI
- 19.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.