Neural machine interfaces for controlling multifunctional powered upper-limb prostheses
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
This article investigates various neural machine interfaces for voluntary control of externally powered upper-limb prostheses. Epidemiology of upper limb amputation, as well as prescription and follow-up studies of externally powered upper-limb prostheses are discussed. The use of electromyographic interfaces and peripheral nerve interfaces for prosthetic control, as well as brain machine interfaces suitable for prosthetic control, are examined in detail along with available clinical results. In addition, studies on interfaces using muscle acoustic and mechanical properties and the problem of interfacing sensory information to the nervous system are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Self-citationBrain oscillations control hand orthosis in a tetraplegic
Pfurtscheller, G., Guger, C., Müller, G., Krausz, G., & Neuper, C. (2000) · Neuroscience Letters · doi:10.1016/s0304-3940(00)01471-3 · Cited by 472
A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415
Self-citationDhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301
BION ™ system for distributed neural prosthetic interfaces
Loeb, G. E., Peck, R. A., Moore, W. H., & Hood, K. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00011-x · Cited by 243
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234
The application of implant technology for cybernetic systems
Warwick, K., Gasson, M., Hutt, B., Goodhew, I., Kyberd, P., Andrews, B., Teddy, P., & Shad, A. (2003) · Archives of Neurology · doi:10.1001/archneur.60.10.1369 · Cited by 206
Dhillon, G. S., Krüger, T. B., Sandhu, J. S., & Horch, K. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00937.2004 · Cited by 183
Lago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177 · cited 2×
“66 Wolpaw JR, Birbaumer N, McFarland DJ, Pfurtscheller G, Vaughan TM. Brain–computer interfaces for communication and control.”
BackgroundRegeneration microelectrode array for peripheral nerve recording and stimulation
Kovacs, G. T. A., Storment, C. W., & Rosen, J. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.256422 · Cited by 168
Lawrence, S. M., Dhillon, G. S., Jensen, W., Yoshida, K., & Horch, K. W. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.831491 · Cited by 106
Riso, R. R. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7604 · Cited by 98
Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode
Lawrence, S. M., Dhillon, G. S., & Horch, K. W. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00231-0 · Cited by 93
Neuroprosthetics: Theory and Practice
Horch, K. W., & Dhillon, G. S. (2004) · Series on Bioengineering and Biomedical Engineering · doi:10.1142/4987 · Cited by 70
Long‐term biocompatibility of implanted polymer‐based intrafascicular electrodes
Lawrence, S. M., Larsen, J. O., Horch, K. W., Riso, R., & Sinkjær, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10303 · Cited by 55
Research works printed but not linked: 65
- Esquenazia, Arch. Phys. Med. Rehabil., 77
- Esquenazia, 2004, Disabil. Rehabil., 26, 831, 10.1080/09638280410001708850 · DOI · Paper page
- Dillingham, 1998, Arch. Phys. Med. Rehabil., 79, 279, 10.1016/S0003-9993(98)90007-7 · DOI
- Atroshi, 2001, Hand Clin., 17, 343, 10.1016/S0749-0712(21)00515-1 · DOI
- Ephraim, 2003, Arch. Phys. Med. Rehabil., 84, 747, 10.1016/S0003-9993(02)04932-8 · DOI · Paper page
- Smith, 2004, Atlas of Amputations and Limb Deficiencies: Surgical, Prosthetic, and Rehabilitation Principles.
- Atkins, 1996, J. Prosthet. & Orthot., 8, 2, 10.1097/00008526-199600810-00003 · DOI · Paper page
- Gaine, 1997, J. Hand Surg, 73, 10.1016/S0266-7681(97)80023-X · DOI · Paper page
- Davidson, 2004, Disabil. Rehabil., 26, 917, 10.1080/09638280410001708940 · DOI
- Parker, 1986, Crit. Rev. Biomed. Eng., 13, 283
- Basmajian, 1985, Muscle Alive.
- 2004, Powered upper limb prostheses: Control, implementation and clinical application.
- Englehart, 1999, Med. Eng. Phys., 2, 431, 10.1016/S1350-4533(99)00066-1 · DOI · Paper page
- Chu JU, Moon I, Mun MS. A real-time EMG pattern recognition based on linear-nonlinear feature projection for multifunction myoelectric hand.Proceedings of 2005 IEEE 9th Int. Conf. on Rehabil. Robotics.Chicago, IL, USA, 295–298 (2005).
- Petterson, 1999, Biomed Sci Instrum.
- 10.1109/TNSRE.2002.806831 · DOI · Paper page
- 10.1109/TBME.2003.818469 · DOI · Paper page
- 10.1080/03091900412331289906 · DOI
- 10.1109/TBME.2004.836492 · DOI · Paper page
- 10.1109/TBME.2005.856295 · DOI · Paper page
- Bu, 2003, J. Intelligent Infor. Syst., 21, 113, 10.1023/A:1024706431807 · DOI
- Englehart K, Hudgins B, Parker P. Multifunction control of prostheses using the myoelectric signal. Chapter 5, In:Intelligent Systems and Technologies in Rehabilitation Engineering,Teodorescu H-N , Jain LC (Ed), CRC Press, Boca Raton, FL, USA, 153–208 (2000). · DOI
- Farrell TR, Weir RFff, Heckathorne CW. The effect of controller delay on box and block test performance.Conf. Proceedings of the Univ. of New Brunswick’s MyoElectric Controls / Powered Prosthetics Symposium (MEC’05).New Brunswick, Canada, 244–247 (2005).
- Lock BA, Englehart K, Hudgin B. Real-time myoelectric control in a virtual environment to relate usability vs. Accuracy.Conf. Proceedings of the Univ. of New Brunswick’s MyoElectric Controls / Powered Prosthetics Symposium (MEC’05).New Brunswick, Canada, 122–126 (2005).
- 10.1023/A:1024758415877 · DOI
- Sebelius, 2005, J. Hand Surg., 780, 10.1016/j.jhsa.2005.01.002 · DOI
- 10.1109/TRA.2003.808873 · DOI · Paper page
- Kuruganti, 1995, IEEE Trans. Biomed. Eng., 42, 109, 10.1109/10.362912 · DOI
- Cote, 2000, Electromyogr. Clin. Neurophysiol., 40, 215
- Weir RFff, Troyk PR, DeMichele G, Kuiken T. Implantable Myoelectric Sensors (IMES) for upper-extremity prosthesis control – preliminary work.Proceedings of the 25th Annual International Conference of the IEEE EMBS,Cancun, Mexico, 1562–1565 (2003). · DOI
- Weir RFff, Troyk PR, DeMichele G, Lowery M, Kuiken T. Implantable myoelectric sensors (IMES).Conf. Proceedings of the Univ. of New Brunswick’s MyoElectric Controls / Powered Prosthetics Symposium (MEC’05).New Brunswick, Canada, 93–97 (2005).
- Arcos, 2002, Artif. Organs, 26, 228, 10.1046/j.1525-1594.2002.06938.x · DOI · Paper page
- Stykov NS, Lowery MM, Heckman CJ, Taflove A, Kuiken TA. Recording Intramuscular EMG signals using surface electrodes.Proceedings of the 2005 IEEE 9th Int Conf. on Rehabil. Robotics,Chicago, IL, USA, 291–294 (2005) · doi:10.1109/icorr.2005.1501104
- Kuiken, 2003, Technol. Disabil., 15, 105, 10.3233/TAD-2003-15206 · DOI · Paper page
- Lipschutz RD, Miller LA, Stubblefield KA, Dumanian G, Phillips ME, Kuiken TA. Transhumeral level fitting and outcomes following targeted hyper-reinnervation nerve transfer surgery.Conf. Proceedings of the Univ. of New Brunswick’s MyoElectric Controls / Powered Prosthetics Symposium (MEC’05).New Brunswick, Canada, 2–5 (2005).
- Miller LA, Lipschutz RD, Stubblefield KA, Kuiken TA. Fitting and outcomes of a bilateral shoulder disarticulation amputee following targeted hyper-reinnervation nerve transfer surgery.Conf. Proceedings of the Univ. of New Brunswick’s MyoElectric Controls / Powered Prosthetics Symposium (MEC’05).New Brunswick, Canada, 6–10 (2005).
- Kyberd, 1994, J. Rehabil. Res. Dev., 31, 326
- 10.1080/03091900210142459 · DOI · Paper page
- Okuno, 2005, IEEE Eng. Med. Biol. Mag., 24, 48, 10.1109/MEMB.2005.1463396 · DOI
- 10.1007/BF02349973 · DOI
- Crampon, 2002, Biomed. Mater. Eng., 12, 397
- De Lucca, 1978, J. Med. Eng. Technol., 2, 57, 10.3109/03091907809161756 · DOI
- Lichtenberg, 1979, IEEE Trans. Biomed. Eng., 26, 228, 10.1109/TBME.1979.326507 · DOI · Paper page
- DiLorenzo DJ, Edell DJ, Koris MJ, Riso RR. Chronic intraneural electrical stimulation for prosthetic sensory feedback.Proceedings of the 1st Int. IEEE EMBS Conf. on Neural Eng.Capri Island, Italy, 116–119 (2003). · DOI
- Stieglitz, 2002, Biosens. Bioelectron., 17, 685, 10.1016/S0956-5663(02)00019-2 · DOI
- Gasson, 2005, Int. J. Adaptive Control Signal Proc., 19, 365, 10.1002/acs.854 · DOI · Paper page
- 10.1109/TRE.2000.847807 · DOI · Paper page
- Vaughan, 2003, IEEE Trans. Neural Syst. Rehabil. Eng., 11, 94, 10.1109/TNSRE.2003.814799 · DOI · Paper page
- 10.1038/nrn1105 · DOI · Paper page
- 10.1038/nn947 · DOI · Paper page
- 10.1161/01.STR.0000143235.93497.03 · DOI · Paper page
- Lauer, 2000, IEEE Trans. Rehabil. Eng., 8, 205, 10.1109/86.847817 · DOI · Paper page
- Pfurtscheller, 200, IEEE Trans. Neural Syst. Rehabil. Eng., 11, 177
- Abboudi, 1999, IEEE Trans. Rehabil. Eng., 7, 121, 10.1109/86.769401 · DOI
- Curcie, 200, IEEE Trans. Neural Syst. Rehabil. Eng., 9, 69, 10.1109/7333.918278 · doi:10.1109/7333.918278
- Silva, 2005, Arch. Phys. Med. Rehabil., 86, 2066, 10.1016/j.apmr.2005.03.034 · DOI
- Gregori, 2003, . Med. Biol. Eng. Comput., 41, 665, 10.1007/BF02349974 · DOI
- Heath, 2003, Technol. Disabil., 15, 73, 10.3233/TAD-2003-15203 · doi:10.3233/tad-2003-15203
- Davalli, 2000, Technol. Disabil., 13, 161, 10.3233/TAD-2000-13303 · DOI
- Lundborg, 1999, J. Hand Surg., 24, 219, 10.1053/jhsu.1999.0219 · DOI
- Kuiken TA, Sensinger JW, Farrell TR, Weir RFff. Phantom limb sensory f eedback through nerve transfer surgery.Conf. Proceedings of the Univ. of New Brunswick’s MyoElectric Controls/Powered Prosthetics Symposium (MEC’05). New Brunswick, Canada, 25–29 (2005).
- 2001, Hand Clin., 17, 481, 10.1016/S0749-0712(21)00526-6 · DOI
- 10.1109/TNSRE.2005.856072 · DOI · Paper page
- 10.1016/S0896-6273(00)81156-3 · DOI · Paper page
- Maruishi, 2004, NeuroImage, 21, 1604, 10.1016/j.neuroimage.2003.12.001 · DOI
Cited by
Losey, D. P., McDonald, C. G., Battaglia, E., & O'Malley, M. K. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4039145 · Cited by 392
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationTopological analysis of population activity in visual cortex
Singh, G., Memoli, F., Ishkhanov, T., Sapiro, G., Carlsson, G., & Ringach, D. L. (2008) · Journal of Vision · doi:10.1167/8.8.11 · Cited by 213
Innovations in Prosthetic Interfaces for the Upper Extremity
Kung, T. A., Bueno, R. A., Alkhalefah, G. K., Langhals, N. B., Urbanchek, M. G., & Cederna, P. S. (2013) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3182a97e5f · Cited by 71
Frost, C. M., Ursu, D. C., Flattery, S. M., Nedic, A., Hassett, C. A., Moon, J. D., Buchanan, P. J., Brent Gillespie, R., Kung, T. A., Kemp, S. W. P., et al. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0452-1 · Cited by 68
Metadata
- Authors
- Ohnishi, K., Weir, R. F., & Kuiken, T. A.
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2007-01
- Volume
- 4
- Issue
- 1
- Pages
- 43-53
- ISSN
- 1743-4440 (ISSN-L)
- 1745-2422
- OpenAlex
- W2048620870
- Cited by
- 102
- References
- 22
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.