The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Real-Time PCR for mRNA Quantitation
Open accessAbstract
Real-time PCR has become one of the most widely used methods of gene quantitation because it has a large dynamic range, boasts tremendous sensitivity, can be highly sequence-specific, has little to no post-amplification processing, and is amenable to increasing sample throughput. However, optimal benefit from these advantages requires a clear understanding of the many options available for running a real-time PCR experiment. Starting with the theory behind real-time PCR, this review discusses the key components of a real-time PCR experiment, including one-step or two-step PCR, absolute versus relative quantitation, mathematical models available for relative quantitation and amplification efficiency calculations, types of normalization or data correction, and detection chemistries. In addition, the many causes of variation as well as methods to calculate intra- and inter-assay variation are addressed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT Method
Livak, K. J., & Schmittgen, T. D. (2001) · Methods · doi:10.1006/meth.2001.1262 · Cited by 180,860
A new mathematical model for relative quantification in real-time RT-PCR
Pfaffl, M. W. (2001) · Nucleic Acids Research · doi:10.1093/nar/29.9.e45 · Cited by 34,610
Vandesompele, J., De Preter, K., Pattyn, F., Poppe, B., Van Roy, N., De Paepe, A., & Speleman, F. (2002) · Genome Biology · doi:10.1186/gb-2002-3-7-research0034 · Cited by 20,038
Pfaffl, M. W. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.9.e36 · Cited by 7,376
Heid, C. A., Stevens, J., Livak, K. J., & Williams, P. M. (1996) · Genome Research · doi:10.1101/gr.6.10.986 · Cited by 6,174
Pfaffl, M. W., Tichopad, A., Prgomet, C., & Neuvians, T. P. (2004) · Biotechnology Letters · doi:10.1023/b:bile.0000019559.84305.47 · Cited by 5,065
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Bustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
Quantification of mRNA using real-time reverse transcription PCR (RT-PCR): trends and problems
Bustin, S. (2002) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0290023 · Cited by 2,546
Kinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G., & Watson, R. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,159
A novel method for real time quantitative RT-PCR.
Gibson, U. E., Heid, C. A., & Williams, P. M. (1996) · Genome Research · doi:10.1101/gr.6.10.995 · Cited by 2,075
Product Differentiation by Analysis of DNA Melting Curves during the Polymerase Chain Reaction
Ririe, K. M., Rasmussen, R. P., & Wittwer, C. T. (1997) · Analytical Biochemistry · doi:10.1006/abio.1996.9916 · Cited by 1,654
An Overview of Real-Time Quantitative PCR: Applications to Quantify Cytokine Gene Expression
Giulietti, A., Overbergh, L., Valckx, D., Decallonne, B., Bouillon, R., & Mathieu, C. (2001) · Methods · doi:10.1006/meth.2001.1261 · Cited by 1,411
Processing of gene expression data generated by quantitative real-time RT-PCR.
Muller, P. Y., Janovjak, H., Miserez, A. R., & Dobbie, Z. (2002) · PubMed · Cited by 1,394
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (2013) · BioTechniques · doi:10.2144/000114043 · Cited by 1,274
Schmittgen, T. D., & Zakrajsek, B. A. (2000) · Journal of Biochemical and Biophysical Methods · doi:10.1016/s0165-022x(00)00129-9 · Cited by 1,242
Quantitative RT-PCR: Pitfalls and Potential
Freeman, W. M., Walker, S. J., & Vrana, K. E. (1999) · BioTechniques · doi:10.2144/99261rv01 · Cited by 1,147
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (1997) · BioTechniques · doi:10.2144/97221bi01 · Cited by 1,143
Schmittgen, T. D., Zakrajsek, B. A., Mills, A. G., Gorn, V., Singer, M. J., & Reed, M. W. (2000) · Analytical Biochemistry · doi:10.1006/abio.2000.4753 · Cited by 1,035
Quantification of low-copy transcripts by continuous SYBR Green I monitoring during amplification.
Morrison, T. B., Weis, J. J., & Wittwer, C. T. (1998) · PubMed · Cited by 958
Quantification on the LightCycler
Rasmussen, R. (2001) · Rapid Cycle Real-Time PCR · doi:10.1007/978-3-642-59524-0_3 · Cited by 892
Peirson, S. N. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng073 · Cited by 843
3'-Minor groove binder-DNA probes increase sequence specificity at PCR extension temperatures
Kutyavin, I. V. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.2.655 · Cited by 797
[18] Fluorescence resonance energy transfer and nucleic acids
Clegg, R. M. (1992) · Methods in Enzymology · doi:10.1016/0076-6879(92)11020-j · Cited by 735
Detection of PCR products using self-probing amplicons and fluorescence
Whitcombe, D., Theaker, J., Guy, S. P., Brown, T., & Little, S. (1999) · Nature Biotechnology · doi:10.1038/11751 · Cited by 697
Thermodynamic basis of the enhanced specificity of structured DNA probes
Bonnet, G., Tyagi, S., Libchaber, A., & Kramer, F. R. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.11.6171 · Cited by 658
Rapid Cycle Real-Time PCR: Methods and Applications
Wittwer, C. (2001) · Rapid Cycle Real-Time PCR · doi:10.1007/978-3-642-59524-0_1 · Cited by 630
Palmer, S., Wiegand, A. P., Maldarelli, F., Bazmi, H., Mican, J. M., Polis, M., Dewar, R. L., Planta, A., Liu, S., Metcalf, J. A., et al. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.10.4531-4536.2003 · Cited by 604
Tricarico, C., Pinzani, P., Bianchi, S., Paglierani, M., Distante, V., Pazzagli, M., Bustin, S. A., & Orlando, C. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00311-1 · Cited by 581
Liu, W., & Saint, D. A. (2002) · Analytical Biochemistry · doi:10.1006/abio.2001.5530 · Cited by 516
Standardized determination of real-time PCR efficiency from a single reaction set-up
Tichopad, A. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng122 · Cited by 455
Validation of a quantitative method for real time PCR kinetics
Liu, W., & Saint, D. A. (2002) · Biochemical and Biophysical Research Communications · doi:10.1016/s0006-291x(02)00478-3 · Cited by 359
Northern blot normalization with a 28S rRNA olinucleotide probe
Barbu, V., & Dautry, F. (1989) · Nucleic Acids Research · doi:10.1093/nar/17.17.7115 · Cited by 352
A closed tube format for amplification and detection of DNA based on energy transfer
Nazarenko, I. A., Bhatnagar, S. K., & Hohman, R. J. (1997) · Nucleic Acids Research · doi:10.1093/nar/25.12.2516 · Cited by 350
Lekanne Deprez, R. H., Fijnvandraat, A. C., Ruijter, J. M., & Moorman, A. F. M. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00021-0 · Cited by 338
Mode of action and application of Scorpion primers to mutation detection
Thelwell, N. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.19.3752 · Cited by 337
Real-time fluorescence genotyping of factor V Leiden during rapid-cycle PCR
Lay, M. J., & Wittwer, C. T. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.12.2262 · Cited by 331
Retinal VEGF mRNA measured by SYBR green I fluorescence: A versatile approach to quantitative PCR.
Simpson, D. A. C., Feeney, S. A., Boyle, C., & Stitt, A. W. (2000) · PubMed · Cited by 326
Multiplex quantitative PCR using self-quenched primers labeled with a single fluorophore
Nazarenko, I. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.9.e37 · Cited by 279
Multiplex detection of single-nucleotide variations using molecular beacons
Marras, S. A. E., Russell Kramer, F., & Tyagi, S. (1999) · Genetic Analysis: Biomolecular Engineering · doi:10.1016/s1050-3862(98)00018-7 · Cited by 270
Medhurst, A. D., Harrison, D. C., Read, S. J., Campbell, C. A., Robbins, M. J., & Pangalos, M. N. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00178-3 · Cited by 262
Hamalainen, H. K., Tubman, J. C., Vikman, S., Kyrölä, T., Ylikoski, E., Warrington, J. A., & Lahesmaa, R. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5369 · Cited by 260
Vandesompele, J., De Paepe, A., & Speleman, F. (2002) · Analytical Biochemistry · doi:10.1006/abio.2001.5564 · Cited by 231
Fronhoffs, S., Totzke, G., Stier, S., Wernert, N., Rothe, M., Brüning, T., Koch, B., Sachinidis, A., Vetter, H., & Ko, Y. (2002) · Molecular and Cellular Probes · doi:10.1006/mcpr.2002.0405 · Cited by 214
Wang, T., & Brown, M. J. (1999) · Analytical Biochemistry · doi:10.1006/abio.1999.4022 · Cited by 196
Quantitative RT-PCR: Limits and Accuracy
Souazé, F., Ntodou-Thomé, A., Tran, C. Y., Rostène, W., & Forgez, P. (1996) · BioTechniques · doi:10.2144/96212rr01 · Cited by 194
WU, D. Y., UGOZZOLI, L., PAL, B. K., QIAN, J., & WALLACE, R. B. (1991) · DNA and Cell Biology · doi:10.1089/dna.1991.10.233 · Cited by 192
Spanakis, E. (1993) · Nucleic Acids Research · doi:10.1093/nar/21.16.3809 · Cited by 175
Homogeneous Multiplex Genotyping of Hemochromatosis Mutations with Fluorescent Hybridization Probes
Bernard, P. S., Ajioka, R. S., Kushner, J. P., & Wittwer, C. T. (1998) · American Journal Of Pathology · doi:10.1016/s0002-9440(10)65650-7 · Cited by 148
Improved quantitative real-time RT-PCR for expression profiling of individual cells
Liss, B. (2002) · Nucleic Acids Research · doi:10.1093/nar/gnf088 · Cited by 140
Measurement of DNA copy number at microsatellite loci using quantitative PCR analysis.
Ginzinger, D. G., Godfrey, T. E., Nigro, J. M., Moore, D. H., Suzuki, S., Pallavicini, M. G., Gray, J. W., & Jensen, R. H. (2000) · PubMed · Cited by 139
Duplex Scorpion primers in SNP analysis and FRET applications
Solinas, A. (2001) · Nucleic Acids Research · doi:10.1093/nar/29.20.e96 · Cited by 139
Inhibition of real-time RT–PCR quantification due to tissue-specific contaminants
Tichopád, A., Didier, A., & Pfaffl, M. W. (2003) · Molecular and Cellular Probes · doi:10.1016/j.mcp.2003.09.001 · Cited by 128
Marino, J. H., Cook, P., & Miller, K. S. (2003) · Journal of Immunological Methods · doi:10.1016/s0022-1759(03)00103-0 · Cited by 116
ZHANG, J., & Byrne, C. D. (1999) · Biochemical Journal · doi:10.1042/bj3370231 · Cited by 107
High-Resolution Semi-Quantitative Real-Time PCR without the Use of a Standard Curve
Gentle, A., Anastasopoulos, F., & McBrien, N. A. (2001) · BioTechniques · doi:10.2144/01313st03 · Cited by 96
Brooks, E. M., Sheflin, L. G., & Spaulding, S. W. (1995) · PubMed · Cited by 87
Evaluation of RNA Isolation Methods and Reference Genes for RT-PCR Analyses of Rare Target RNA
Mannhalter, C., Koizar, D., & Mitterbauer, G. (2000) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2000.026 · Cited by 81
Research works printed but not linked: 11
- 10.1093/clinchem/45.5.694 · doi:10.1093/clinchem/45.5.694
- 10.1038/sj.bmt.1701405 · doi:10.1038/sj.bmt.1701405
- Gerard, C.J., K.Olsson, R.Ramanathan, C.Reading, and E.G.Hanania. 1998. Improved quantitation of minimal residual disease in multiple myeloma using real-time polymerase chain reaction and plasmid-DNA complementarity determining region III standards. Cancer Res.58:3957–3964.
- Livak, K. 1997. ABI Prism 7700 Sequence Detection System, User Bulletin 2. PE Applied Biosystems, Foster City, CA.
- 10.1007/978-1-4615-1325-4_92 · doi:10.1007/978-1-4615-1325-4_92
- Technical Bulletin #151 . Use of Internal and External Standards or Reference RNAs for Accurate Quantitation of RNA Levels. Ambion, Austin, TX, USA.
- 10.1046/j.1365-3083.2003.01250.x · doi:10.1046/j.1365-3083.2003.01250.x
- 10.1093/clinchem/46.2.147 · doi:10.1093/clinchem/46.2.147
- 10.1038/81192 · doi:10.1038/81192
- 10.1016/0735-0651(89)90022-8 · doi:10.1016/0735-0651(89)90022-8
- 10.1007/s004180100253 · doi:10.1007/s004180100253
Cited by
(2012) · doi:10.1016/j.jmoldx.2011.08.002 · Cited by 2,567
A genome-wide transgenic RNAi library for conditional gene inactivation in Drosophila
Dietzl, G., Chen, D., Schnorrer, F., Su, K.-C., Barinova, Y., Fellner, M., Gasser, B., Kinsey, K., Oppel, S., Scheiblauer, S., et al. (2007) · Nature · doi:10.1038/nature05954 · Cited by 2,644
Diagnosing COVID-19: The Disease and Tools for Detection
Udugama, B., Kadhiresan, P., Kozlowski, H. N., Malekjahani, A., Osborne, M., Li, V. Y. C., Chen, H., Mubareka, S., Gubbay, J. B., & Chan, W. C. W. (2020) · ACS Nano · doi:10.1021/acsnano.0c02624 · Cited by 1,754
RNA integrity and the effect on the real-time qRT-PCR performance
Fleige, S., & Pfaffl, M. W. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.003 · Cited by 1,487
Environmental DNA: For Biodiversity Research and Monitoring
Taberlet, P., Bonin, A., Zinger, L., & Coissac, E. (2018) · doi:10.1093/oso/9780198767220.001.0001 · Cited by 1,059
Metadata
- Authors
- Wong, M. L., & Medrano, J. F.
- Venue
- BioTechniques
- Publisher
- Informa UK Limited
- Published
- 2005-07
- Volume
- 39
- Issue
- 1
- Pages
- 75-85
- ISSN
- 0736-6205 (ISSN-L)
- 1940-9818
- OpenAlex
- W2122749842
- Cited by
- 1,786
- References
- 59
- FWCI
- 27.08
- Type
- journal article
- Language
- en
- Open access
- gold
- Funders
- National Institutes of Health (NIH T32-GM08799-01)
- U.S. Department of Agriculture (2001-52100-11211)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.