Acoustic Inversion in Optoacoustic Tomography: A Review
Open accessThe DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Abstract
Optoacoustic tomography enables volumetric imaging with optical contrast in biological tissue at depths beyond the optical mean free path by the use of optical excitation and acoustic detection. The hybrid nature of optoacoustic tomography gives rise to two distinct inverse problems: The optical inverse problem, related to the propagation of the excitation light in tissue, and the acoustic inverse problem, which deals with the propagation and detection of the generated acoustic waves. Since the two inverse problems have different physical underpinnings and are governed by different types of equations, they are often treated independently as unrelated problems. From an imaging standpoint, the acoustic inverse problem relates to forming an image from the measured acoustic data, whereas the optical inverse problem relates to quantifying the formed image. This review focuses on the acoustic aspects of optoacoustic tomography, specifically acoustic reconstruction algorithms and imaging-system practicalities. As these two aspects are intimately linked, and no silver bullet exists in the path towards high-performance imaging, we adopt a holistic approach in our review and discuss the many links between the two aspects. Four classes of reconstruction algorithms are reviewed: time-domain (so called back-projection) formulae, frequency-domain formulae, time-reversal algorithms, and model-based algorithms. These algorithms are discussed in the context of the various acoustic detectors and detection surfaces which are commonly used in experimental studies. We further discuss the effects of non-ideal imaging scenarios on the quality of reconstruction and review methods that can mitigate these effects. Namely, we consider the cases of finite detector aperture, limited-view tomography, spatial under-sampling of the acoustic signals, and acoustic heterogeneities and losses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331 · cited 1×
“[55-60] and the references contained therein.”
Photoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700 · cited 3×
“[61] it was noted that over-sampling in the spatial domain, i.”
Influentialk-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields
Treeby, B. E., & Cox, B. T. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3360308 · Cited by 2,337
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896 · cited 1×
“[55-60] and the references contained therein.”
Self-citationFunctional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854 · cited 4×
“3), high-resolution imaging with large-area detectors requires that the detectors be spherically focused [3].”
InfluentialWang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700 · cited 5×
“Over the past two decades, optoacoustic imaging has seen steady growth and has demonstrated notable capabilities to visualize living biological tissues with multiple applications emerging in both small-animal and clinical imaging [1-10].”
InfluentialCarbon nanotubes as photoacoustic molecular imaging agents in living mice
De La Zerda, A., Zavaleta, C., Keren, S., Vaithilingam, S., Bodapati, S., Liu, Z., Levi, J., Smith, B. R., Ma, T.-J., Oralkan, O., et al. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.231 · Cited by 1,271
Universal back-projection algorithm for photoacoustic computed tomography
Xu, M., & Wang, L. V. (2005) · Physical Review E · doi:10.1103/physreve.71.016706 · Cited by 1,243
A Wavelet Tour of Signal Processing, Third Edition: The Sparse Way
Mallat, S. (2008) · Academic Press eBooks · Cited by 947
Molecular Imaging by Means of Multispectral Optoacoustic Tomography (MSOT)
Ntziachristos, V., & Razansky, D. (2010) · Chemical Reviews · doi:10.1021/cr9002566 · Cited by 776
Self-citationOptical-resolution photoacoustic microscopy for in vivo imaging of single capillaries
Maslov, K., Zhang, H. F., Hu, S., & Wang, L. V. (2008) · Optics Letters · doi:10.1364/ol.33.000929 · Cited by 763 · cited 3×
“Over the past two decades, optoacoustic imaging has seen steady growth and has demonstrated notable capabilities to visualize living biological tissues with multiple applications emerging in both small-animal and clinical imaging [1-10].”
Quantitative spectroscopic photoacoustic imaging: a review
Cox, B., Laufer, J. G., Arridge, S. R., & Beard, P. C. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.6.061202 · Cited by 720 · cited 1×
“[55-60] and the references contained therein.”
Multispectral opto-acoustic tomography of deep-seated fluorescent proteins in vivo
Razansky, D., Distel, M., Vinegoni, C., Ma, R., Perrimon, N., Köster, R. W., & Ntziachristos, V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.98 · Cited by 644
Self-citationZhang, E., Laufer, J. G., & Beard, P. C. (2008) · Applied Optics · doi:10.1364/ao.47.000561 · Cited by 611 · cited 6×
“In recent years, optical interferometric detection of ultrasound has emerged as a possible alternative to conventional piezoelectric technology, which shows promise for future miniaturization of optoacoustic imaging systems [34, 39, 47-50].”
InfluentialPhotoacoustic ultrasound (PAUS)—Reconstruction tomography
Kruger, R. A., Liu, P., Fang, Y. “., & Appledorn, C. R. (1995) · Medical Physics · doi:10.1118/1.597429 · Cited by 572 · cited 2×
“With the adoption of analytical inversion formulae from the field of computerized tomography, two- and threedimensional optoacoustic tomographies have later become possible [16].”
Time-domain reconstruction for thermoacoustic tomography in a spherical geometry
Xu, M., & Wang, L. V. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.801176 · Cited by 461 · cited 4×
“Accordingly, in the cases of cylindrical and spherical geometries [25, 32, 98], the waves are cylindrical and spherical, and the detection surfaces are a cylinder and a sphere, respectively.”
InfluentialThree-dimensional photoacoustic imaging of blood vessels in tissue
Hoelen, C. G. A., de Mul, F. F. M., Pongers, R., & Dekker, A. (1998) · Optics Letters · doi:10.1364/ol.23.000648 · Cited by 446
Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo
Yang, J.-M., Favazza, C., Chen, R., Yao, J., Cai, X., Maslov, K., Zhou, Q., Shung, K. K., & Wang, L. V. (2012) · Nature Medicine · doi:10.1038/nm.2823 · Cited by 429 · cited 1×
“Over the past two decades, optoacoustic imaging has seen steady growth and has demonstrated notable capabilities to visualize living biological tissues with multiple applications emerging in both small-animal and clinical imaging [1-10].”
In vivo dark-field reflection-mode photoacoustic microscopy
Maslov, K., Stoica, G., & Wang, L. V. (2005) · Optics Letters · doi:10.1364/ol.30.000625 · Cited by 413 · cited 1×
“Keywords: Optoacoustic imaging, photoacoustic imaging, tomography, inverse problems, ultrasound detectors, algorithms, acoustic waves.”
Determining a Function from Its Mean Values Over a Family of Spheres
Finch, D., & Patch, S. K. (2004) · SIAM Journal on Mathematical Analysis · doi:10.1137/s0036141002417814 · Cited by 410
Reconstructions in limited‐view thermoacoustic tomography
Xu, Y., Wang, L. V., Ambartsoumian, G., & Kuchment, P. (2004) · Medical Physics · doi:10.1118/1.1644531 · Cited by 398 · cited 3×
“[126] as it affects objects of all scales, and is not limited to only sharp boundaries, as shown in (Fig.”
Photoacoustic tomography in absorbing acoustic media using time reversal
Treeby, B. E., Zhang, E. Z., & Cox, B. T. (2010) · Inverse Problems · doi:10.1088/0266-5611/26/11/115003 · Cited by 354 · cited 3×
“Specifically, the loss term in the original equation turns into a gain term in the time-reversed equation [104].”
The Application of Compressed Sensing for Photo-Acoustic Tomography
Provost, J., & Lesage, F. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2007825 · Cited by 338 · cited 3×
“When the acoustic signals are spatially under-sampled, streak artifacts often appear in the image [115, 116].”
Hristova, Y., Kuchment, P., & Nguyen, L. (2008) · Inverse Problems · doi:10.1088/0266-5611/24/5/055006 · Cited by 335 · cited 2×
“Specifically, time-reversal algorithms have been demonstrated with arbitrary detection boundaries [81], acoustic heterogeneities [105, 106] and acoustic absorption and dispersion [104].”
Laufer, J., Delpy, D., Elwell, C., & Beard, P. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/1/010 · Cited by 319
Volumetric real-time multispectral optoacoustic tomography of biomarkers
Razansky, D., Buehler, A., & Ntziachristos, V. (2011) · Nature Protocols · doi:10.1038/nprot.2011.351 · Cited by 309 · cited 8×
“For example, piezoelectric detector arrays are commonly manufactured over flat [83, 84] or curved surfaces [8, 24, 36], and”
InfluentialSelf-citationIn vivo preclinical photoacoustic imaging of tumor vasculature development and therapy
Laufer, J. G., Zhang, E. Z., Treeby, B. E., Cox, B. T., Beard, P. C., Johnson, P., & Pedley, B. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.5.056016 · Cited by 308 · cited 4×
“Point [25], [26] [32], [33] [10], [39], [40]”
InfluentialWhole-body three-dimensional optoacoustic tomography system for small animals
Brecht, H.-P. F., Su, R., Fronheiser, M. P., Ermilov, S. A., Conjusteau, A., & Oraevsky, A. A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3259361 · Cited by 304 · cited 2×
“the breast [26] or skin [10], rather than in wholebody imaging scenarios [30].”
Photoacoustic angiography of the breast
Kruger, R. A., Lam, R. B., Reinecke, D. R., Del Rio, S. P., & Doyle, R. P. (2010) · Medical Physics · doi:10.1118/1.3497677 · Cited by 302 · cited 3×
“Point [25], [26] [32], [33] [10], [39], [40]”
Ultrasound Transducers for Pulse-Echo Medical Imaging
HUNT, J. W., Arditi, M., & Foster, F. S. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325150 · Cited by 293 · cited 3×
“First, these equations have been developed for focused transducers in 3D space with circular apertures (focused disks) [67].”
Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system
Kim, C., Erpelding, T. N., Jankovic, L., Pashley, M. D., & Wang, L. V. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000278 · Cited by 289 · cited 1×
“Keywords: Optoacoustic imaging, photoacoustic imaging, tomography, inverse problems, ultrasound detectors, algorithms, acoustic waves.”
Fast Semi-Analytical Model-Based Acoustic Inversion for Quantitative Optoacoustic Tomography
Rosenthal, A., Razansky, D., & Ntziachristos, V. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2044584 · Cited by 285 · cited 8×
“Numerical simulations have shown that these artifacts are most apparent when back-projection algorithms are used, whereas model-based inversion is less affected by streak artifacts [111, 113].”
InfluentialSelf-citationHuang, C., Wang, K., Nie, L., Wang, L. V., & Anastasio, M. A. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2254496 · Cited by 276
Xu, M., Xu, Y., & Wang, L. V. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.816081 · Cited by 274 · cited 2×
“Point [25], [26] [32], [33] [10], [39], [40]”
Iterative reconstruction algorithm for optoacoustic imaging
Paltauf, G., Viator, J. A., Prahl, S. A., & Jacques, S. L. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1501898 · Cited by 269 · cited 2×
“Namely, because the connection between the measured acoustic field and optoacoustic source is linear, its discretization may be written in a matrix form [107]:”
Zharov, V. P., Galanzha, E. I., Shashkov, E. V., Khlebtsov, N. G., & Tuchin, V. V. (2006) · Optics Letters · doi:10.1364/ol.31.003623 · Cited by 229 · cited 1×
“optical resolution microscopy [6] and flow cytometry [23], the focus of this review is solely on tomographic imaging scenarios, such as those found in Refs.”
Photoacoustic tomography: fundamentals, advances and prospects
Yao, J., & Wang, L. V. (2011) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.443 · Cited by 226 · cited 1×
“[55-60] and the references contained therein.”
Burgholzer, P., Matt, G. J., Haltmeier, M., & Paltauf, G. (2007) · Physical Review E · doi:10.1103/physreve.75.046706 · Cited by 216 · cited 3×
“generalized the far-field inversion equation to arbitrary closed surfaces and obtained the following equation [81]:”
Accurate Model-Based Reconstruction Algorithm for Three-Dimensional Optoacoustic Tomography
Dean-Ben, X. L., Buehler, A., Ntziachristos, V., & Razansky, D. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2208471 · Cited by 210 · cited 3×
“f n r ( ) , one obtains the model matrix M [31, 107, 111-113].”
Self-citationMultispectral photoacoustic imaging of fluorochromes in small animals
Razansky, D., Vinegoni, C., & Ntziachristos, V. (2007) · Optics Letters · doi:10.1364/ol.32.002891 · Cited by 193 · cited 2×
“Optically, the large variations in the optical scattering and absorption coefficient of biological tissue lead to a highly complex non-linear inverse problem, whereas the processing of multi-spectral data often requires some a priori knowledge of the background spectrum [51] and accounting for depth-dependant variatio…”
Self-citationInvestigation of iterative image reconstruction in three-dimensional optoacoustic tomography
Wang, K., Su, R., Oraevsky, A. A., & Anastasio, M. A. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/17/5399 · Cited by 191 · cited 2×
“Many regularization techniques have been demonstrated for optoacoustic tomography, including Tikhonov regularization [113, 115], singular value decomposition (SVD) [115], multi-scale techniques [115, 116], limited-iteration LSQR [117], and total-variation (TV) regularization [118].”
Photoacoustic Spectroscopy of Biological Materials
Rosencwaig, A. (1973) · Science · doi:10.1126/science.181.4100.657 · Cited by 181 · cited 1×
“In the 1970s, the effect was first suggested for sensing biological tissue [13].”
Estimating chromophore distributions from multiwavelength photoacoustic images
Cox, B. T., Arridge, S. R., & Beard, P. C. (2009) · Journal of the Optical Society of America A · doi:10.1364/josaa.26.000443 · Cited by 174 · cited 2×
“Optically, the large variations in the optical scattering and absorption coefficient of biological tissue lead to a highly complex non-linear inverse problem, whereas the processing of multi-spectral data often requires some a priori knowledge of the background spectrum [51] and accounting for depth-dependant variatio…”
Pulsed near-infrared laser diode excitation system for biomedical photoacoustic imaging
Allen, T. J., & Beard, P. C. (2006) · Optics Letters · doi:10.1364/ol.31.003462 · Cited by 174 · cited 1×
“In optoacoustic microscopy and other superficial applications, where such high per-pulse energies are not required, other types of sources in the microjoule and nanojoule ranges are considered as well, including high repetition rate lasers [20], laser diodes [21] and fiber lasers [22].”
Compressed sensing in photoacoustic tomography in vivo
Guo, Z., Li, C., Song, L., & Wang, L. V. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3381187 · Cited by 172 · cited 3×
“When the acoustic signals are spatially under-sampled, streak artifacts often appear in the image [115, 116].”
Intravascular photoacoustic imaging using an IVUS imaging catheter
Sethuraman, S., Aglyamov, S., Amirian, J., Smalling, R., & Emelianov, S. (2007) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.343 · Cited by 166 · cited 1×
“Over the past two decades, optoacoustic imaging has seen steady growth and has demonstrated notable capabilities to visualize living biological tissues with multiple applications emerging in both small-animal and clinical imaging [1-10].”
Noninvasive photoacoustic imaging of the developing vasculature during early tumor growth
Lao, Y., Xing, D., Yang, S., & Xiang, L. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/013 · Cited by 153 · cited 1×
“Keywords: Optoacoustic imaging, photoacoustic imaging, tomography, inverse problems, ultrasound detectors, algorithms, acoustic waves.”
Taruttis, A., Morscher, S., Burton, N. C., Razansky, D., & Ntziachristos, V. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030491 · Cited by 144 · cited 1×
“Keywords: Optoacoustic imaging, photoacoustic imaging, tomography, inverse problems, ultrasound detectors, algorithms, acoustic waves.”
Self-citationHalf-time image reconstruction in thermoacoustic tomography
Anastasio, M. A., Zhang, J., Pan, X., Zou, Y. S., Ku, G., & Wang, L. V. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.839682 · Cited by 138 · cited 1×
“the detection field of finite-size detectors [31, 74] or acoustic heterogeneities [108-110].”
Blind source unmixing in multi-spectral optoacoustic tomography
Glatz, J., Deliolanis, N. C., Buehler, A., Razansky, D., & Ntziachristos, V. (2011) · Optics Express · doi:10.1364/oe.19.003175 · Cited by 121 · cited 1×
“In many cases, multispectral measurements may be used to extract quantified information on the distribution of tissue chromophores based on their optical absorption spectrum [51-54].”
Self-citationPhotoacoustic imaging of the microvasculature with a high-frequency ultrasound array transducer
Zemp, R. J., Bitton, R. R., Shung, K. K., Li, M.-L., Stoica, G., & Wang, L. V. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2709850 · Cited by 118 · cited 1×
“For example, piezoelectric detector arrays are commonly manufactured over flat [83, 84] or curved surfaces [8, 24, 36], and”
Gâteau, J., Caballero, M. Á. A., Dima, A., & Ntziachristos, V. (2012) · Medical Physics · doi:10.1118/1.4770292 · Cited by 112
Self-citationArtifact Trapping During Time Reversal Photoacoustic Imaging for Acoustically Heterogeneous Media
Cox, B., & Treeby, B. E. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2032358 · Cited by 106 · cited 3×
“Specifically, time-reversal algorithms have been demonstrated with arbitrary detection boundaries [81], acoustic heterogeneities [105, 106] and acoustic absorption and dispersion [104].”
Quantitative Optoacoustic Signal Extraction Using Sparse Signal Representation
Rosenthal, A., Razansky, D., & Ntziachristos, V. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2027116 · Cited by 94 · cited 1×
“Although the low-frequency data in the reconstruction generally does not reveal much interesting structure, it plays a major role in the optical inverse problem of optoacoustics [122].”
Self-citationThree-dimensional photoacoustic imaging using fiber-based line detectors
Grün, H., Berer, T., Burgholzer, P., et al. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3381186 · Cited by 70
Three-dimensional optoacoustic tomography at video rate
Buehler, A., Deán‐Ben, X. L., Claussen, J., Ntziachristos, V., & Razansky, D. (2012) · Optics Express · doi:10.1364/oe.20.022712 · Cited by 68 · cited 3×
“in small animal imaging applications, imaging speed might be favored over spatial resolution in order to enable high throughput and reduce motion artifacts [24, 77], whereas in some stationary clinical applications, it may be preferable to have longer imaging sessions in order to obtain the highest resolution possible…”
Self-citationIntegrated intravascular ultrasound and photoacoustic imaging scan head
Hsieh, B., Chen, S., Ling, T., Guo, L. J., & Li, P. (2010) · Optics Letters · doi:10.1364/ol.35.002892 · Cited by 64 · cited 1×
“Ad hoc solutions such as the application of the Hilbert transform may lead to positive images [121], but cannot truly restore the lost low-frequency data.”
Weight factors for limited angle photoacoustic tomography
Paltauf, G., Nuster, R., & Burgholzer, P. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/11/002 · Cited by 63 · cited 2×
“For regions outside the detection region, some features may be lost in the reconstructed source [94], [126].”
Oraevsky, E. A., & Anastasio, M. A. (2016) · Cited by 48
Model-based optoacoustic imaging using focused detector scanning
Caballero, M. Á. A., Rosenthal, A., Gâteau, J., Razansky, D., & Ntziachristos, V. (2012) · Optics Letters · doi:10.1364/ol.37.004080 · Cited by 40 · cited 1×
“face of cylindrically [128] and spherically [129] focused detector was included in the model.”
Self-citationWang, K., & Anastasio, M. A. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/n493 · Cited by 39 · cited 1×
“[99] for the spherical case could potentially offer an attractive alternative to the back-projection approach.”
Optoacoustic determination of spatio- temporal responses of ultrasound sensors
Caballero, M. Á. A., Rosenthal, A., Buehler, A., Razansky, D., & Ntziachristos, V. (2013) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.2687 · Cited by 38 · cited 1×
“11 is valid, a hybrid method based on both measurement and simulation may be used [114].”
Self-citationPetschke, A., & Rivière, P. J. L. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.001188 · Cited by 36 · cited 1×
“using modulated continuous wave sources [18], methods relying on pulsed excitation exhibit significantly better imaging performance in terms of sensitivity [19].”
Cited by
Photoacoustic clinical imaging
Steinberg, I., Huland, D. M., Vermesh, O., Frostig, H. E., Tummers, W. S., & Gambhir, S. S. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.05.001 · Cited by 553
Fully Dense UNet for 2-D Sparse Photoacoustic Tomography Artifact Removal
Guan, S., Khan, A. A., Sikdar, S., & Chitnis, P. V. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2912935 · Cited by 538
Deep learning for photoacoustic tomography from sparse data
Antholzer, S., Haltmeier, M., & Schwab, J. (2019) · Inverse Problems in Science and Engineering · doi:10.1080/17415977.2018.1518444 · Cited by 301
Deep learning optoacoustic tomography with sparse data
Davoudi, N., Deán-Ben, X. L., & Razansky, D. (2019) · Nature Machine Intelligence · doi:10.1038/s42256-019-0095-3 · Cited by 276
Self-citation
Metadata
- Authors
- Rosenthal, A., Ntziachristos, V., & Razansky, D.
- Venue
- Current Medical Imaging Reviews
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2014-01-31
- Volume
- 9
- Issue
- 4
- Pages
- 318-336
- ISSN
- 1573-4056 (ISSN-L)
- OpenAlex
- W2050261554
- Cited by
- 236
- References
- 64
- FWCI
- 9.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.