Biodegradable synthetic polymers for tissue engineering
Open accessThe DOI matches its Crossref record; 96 of the 97 references it cites were found in a registry or an index; 1 of the 146 sources its claims cite were checked for support.
Abstract
This review focuses on biodegradable synthetic polymers, discussing synthesis, properties and biodegradability, especially within the polyester family including polylactides.
Overview
CoChat Summary
TL;DR
This review surveys biodegradable synthetic polymers for tissue engineering, emphasizing polyesters (PGA, PLA, PLGA), polylactones, poly(propylene fumarate), polyanhydrides, tyrosine-derived polycarbonates, polyorthoesters, polyurethanes, and polyphosphazenes. It concludes that polyesters dominate clinically, while injectable in situ curable systems such as PPF and photocrosslinkable polyanhydrides are promising but face challenges in biocompatibility, degradation control, and heat generation.
Key findings
- Polyesters are the most studied biodegradable polymers. PGA has 46–50% crystallinity, Tg 36°C, Tm 225°C; in Dexon sutures in vitro, first-stage degradation predominates for 21 days, crystalline degradation takes a further 28 days, and after 49 days weight loss was about 42% with complete loss of mechanical properties.
- PLA/PGA copolymer behavior depends on composition: 25–75% (l)LA/GA and 0–70% (dl)LA/GA are amorphous; 70/30 GA/LA has the highest water uptake, while 50/50 is reported as most unstable to hydrolysis; Vicryl is 8% (l)LA and 92% GA.
- Poly(caprolactone) degrades slowly: homopolymer degradation is on the order of 2–3 years, and PCL with initial average molecular weight 50,000 takes about 3 years for complete in vitro degradation.
- Poly(propylene fumarate) degrades to fumaric acid and propylene glycol; time to 20% original weight loss ranged from 84 days (PPF/β-TCP composite) to over 200 days (PPF/CaSO4 composite). PPF formulations showed maximum curing temperatures of 38–48°C versus 94°C for PMMA cements, curing times of 1–121 min, and compressive strengths of 1–12 MPa.
- Polyanhydrides degrade by surface erosion; poly(sebacic acid) degrades in about 54 days in saline, while poly(1,6-bis(p-carboxyphenoxy)hexane) is estimated at 1 year. Poly[1,6-bis(carboxyphenoxy)hexane] has a Young’s modulus of 1.3 MPa versus human bone at 40–60 MPa; poly(anhydride-co-imides) reached compressive strengths of 50–60 MPa, and photocrosslinked systems showed compressive strengths of 30–40 MPa and tensile strengths of 15–27 MPa.
- Degradable polyurethanes based on lysine diisocyanate showed varied properties: dl-lactide networks were rigid (Tg = 60°C) with ultimate tensile strengths of ~40–70 MPa, caprolactone triol networks were low-modulus elastomers with tensile strengths of 1–4 MPa, and copolymer networks had elongation up to 600% with compressive strengths of 3–25 MPa. In vivo, porous polyurethane artificial skin degraded almost completely 4–8 weeks after implantation in guinea pigs with no adverse tissue reaction.
Methods
- Design: narrative literature review; no primary experimental study or systematic review protocol is reported.
- Data/sample: published literature on biodegradable synthetic polymers, including synthesis, properties, degradation, biocompatibility, and injectable polymer systems; Tables 1–3 summarize polymer properties and precursors.
- Analysis: qualitative synthesis of major polymer classes, their degradation modes/products, mechanical properties, biocompatibility, and potential for injectable tissue-engineering compositions.
Limitations
- Stated: the paper notes that Table 2 data “should be used as a guide only” and that sufficient data are not available to provide a comprehensive list of properties for polyanhydrides, polycarbonates, polyurethanes, and polyphosphazenes.
- Stated: for polyanhydrides, no data are reported about polymer sterilizability and heat generation during polymerization; for degradable polyurethanes, the effect of degradation products and how they are removed from the body are not clearly understood.
- Evident: as a narrative review, it lacks systematic search criteria, study quality appraisal, and meta-analysis, so conclusions depend on the cited literature and may not comprehensively cover all biodegradable polymers or tissue-engineering applications.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
1 Valid · 20 Not valid · 105 Not checked · 89 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“A meniscal replica implanted contained only fibro-cartilage after 18 weeks and decreased the degradation of the articular cartilage.”
What the sources say
- Supportedcites De Groot et al.., 1996 source
The Aliphatic PU network passage (page not provided) reports that articular-cartilage degeneration was less severe with the prosthesis than in meniscectomized control knees. It also says the prostheses contained only fibrocartilage after 18 weeks. Degeneration was reduced, not eliminated. (LLM, conf=0.91)
plainstates a causeSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
In the paper
“The compressive strengths varied between 1 and 12 MPa”
What the sources say
- Not matchedcites Peter et al., 1998a
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Cross-linking characteristics reported for PPF, N-vinyl pyrrolidone (N-VP), benzoyl peroxide, sodium chloride, and TCP indicate that for a range of formulations, the maximum temperature varied within 38 to about 48ºC, compared to 94ºC observed for polymethylmethacrylate (PMMA) cements.”
What the sources say
- Not matchedcites Peter et al., 1998a
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper in Crossref, so there is nothing to check it against.
In the paper
“Based on in-vitro studies, the time required to reach 20% loss in original weight ranged from 84 (PPF/ß-TCP composite) to over 200 days (PPF/CaSO 4 composite)”
What the sources say
- Not matchedcites Peter et al., 1997b
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Not matchedcites Kharas et al., 1997
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“These composite materials exhibit compressive strengths in the range 2 to 30 MPa.”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
94 more claims
Create a free account to see all 215 claims and to verify the 2 references still open.
- It may state two separate claims as one. 62
- Probably not a substantial claim. 76
- The quote only partly states this claim. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Advantages include a tightly controlled manufacturing process, accurate reproducibility, adjustable biodegradability, and a wide variety of both chemical and physical properties.[ 171 ]”
From Unraveling and Harnessing the Immune Response at the Cell–Biomaterial Interface for Tissue Engineering Purposes (2024) · cites this paper as [171]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Polyanhydrides
“Polyanhydrides degrades by surface erosion (Kohn and Langer, 1997) and their main applications are in controlled drug delivery.”
§ Conclusions
“Polyanhydride degrade by bulk erosion and their main applications are in controlled drug delivery.”
Citations
Cites
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741 · cited 4×
“…developments in siloxane-based polyurethanes, which have greater in-vivo stability than conventional polyetherurethanes (e.g., poly(tetramethylene oxide) (PTMO)-based) have provided opportunities for development of a range of medical implants for chronic applications (Gunatillake et al., 2001).”
BackgroundInfluentialBiomaterial developments for bone tissue engineering
Burg, K. J. L., Porter, S., & Kellam, J. F. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00102-2 · Cited by 1,643 · cited 1×
“Polyesters have also been considered for development of tissue engineering applications (Hubbell, 1995; Thomson et al 1995a, Yazemski et al. 1996; Wong and Mooney, 1997), particularly for bone tissue engineering (Kohn and Langer, 1997; Burg et al., 2000).”
BackgroundChandra, R. (1998) · Progress in Polymer Science · doi:10.1016/s0079-6700(97)00039-7 · Cited by 1,462
Biodegradable polymers for use in surgery—polyglycolic/poly(actic acid) homo- and copolymers: 1
Gilding, D. K., & Reed, A. M. (1979) · Polymer · doi:10.1016/0032-3861(79)90009-0 · Cited by 1,345
Biomaterials in Tissue Engineering
Hubbell, J. A. (1995) · Nature Biotechnology · doi:10.1038/nbt0695-565 · Cited by 1,060 · cited 1×
“Polyesters have also been considered for development of tissue engineering applications (Hubbell, 1995; Thomson et al 1995a, Yazemski et al. 1996; Wong and Mooney, 1997), particularly for bone tissue engineering (Kohn and Langer, 1997; Burg et al., 2000).”
BackgroundPolylactic Acid for Surgical Implants
KULKARNI, R. K. (1966) · Archives of Surgery · doi:10.1001/archsurg.1966.01330050143023 · Cited by 841
Evolution of bone transplantation: molecular, cellular and tissue strategies to engineer human bone
Yaszemski, M. J., Payne, R. G., Hayes, W. C., Langer, R., & Mikos, A. G. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85762-0 · Cited by 729
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722 · cited 2×
“For the (l)LA/GA copolymers, resistance to hydrolysis is more pronounced at either end of the copolymers compositions range (Miller et al., 1977; Gilding and Reed, 1979; Reed and Gilding, 1981; Vert et al., 1984).”
BackgroundInjectable biodegradable materials for orthopedic tissue engineering
Temenoff, J. S., & Mikos, A. G. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00108-3 · Cited by 554 · cited 8×
“A number of methods have been reported to prepare PPF, and each results in different polymer properties (Peter et al., 1997a,b, 1999; Temenoff and Mikos 2000).”
BackgroundMethodInfluentialLeong, K. W., Brott, B. C., & Langer, R. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190806 · Cited by 541 · cited 12×
“The polyurethanes ranged from elastomers with elongations at break as high as 780 %, but with low tensile strengths (5.8 to 8.1 MPa).”
BackgroundInfluential
Research works printed but not linked: 5
- Scranton A, Bowman C, Peiffer R, eds. ACS Symposium Series 673; American Chemical Society, Washington DC. pp 189-202.
- Ratner BD, Hoffman AS, Schoen FJ, Lemon JE, eds. Aca- demic Press, San Diego. pp 65-73.
- Lamba NMK, Woodhouse KA, Cooper SL (1998) Poly- urethanes in Biomedical Applications. CRC Press: New York p 205-241.
- Mark JE, Alcock HR, West R (1992) Inorganic Poly- mers. Prentice Hall, Upper Saddle River, NJ. Chapter
- Ng SY, Vandamme T, Tayler MS, Heller J (1997) Syn- thesis and erosion studies of self-catalysed poly(orthoester)s. Macromolecules 30: 770-772.
Cited by
Items 1,501–1,600 of 1,762
Green Materials for 3D Printing in Dentistry
Banakar, M., Sijanivandi, S., Mousavi, S. M., Hashemi, S. A., & Lai, C. W. (2024) · Encyclopedia of Green Materials · doi:10.1007/978-981-97-4618-7_69 · Cited by 1
Badania wpływu wielofunkcyjnego oligomeru na niektóre właściwości polilaktydu
Malinowski, R., Zenkiewicz, M., & Dzwonkowski, J. (2012) · Przetwórstwo Tworzyw
Allo, B. A. (2013) · Scholarship@Western (Western University)
Bone graft substitutes as drug–device combination products
Koller, G., Buranawat, B., & Silvio, L. D. (2010) · Elsevier eBooks · doi:10.1533/9781845697488.2.230
Biopolymers Based on Carboxylic Acids Derived from Renewable Resources
Kumar, S., Prakash, N., & Datta, D. (2011) · Biopolymers · doi:10.1002/9781118164792.ch7
Novel Design of a Gradual Portosystemic Shunt Occluder
Cushman, E. A., Ladd, M. R., Watson, G. I., & Weinberg, D. L. (2005)
Designed Biodegradable and Osteoconductive Porous Scaffolds for Human Trabecular Bone
Saito, E. (2011) · Deep Blue (University of Michigan)
Dynamic Materials Mimic Developmental and Disease Changes in Tissues
Ondeck, M. G., & Engler, A. J. (2014) · Wiley eBooks · doi:10.1002/9781118843499.ch2
Industrial Water Soluble Polymers in Packaging
Bragança, R., & Fowler, P. (2007) · Wiley eBooks · doi:10.1002/9780470988701.ch10
Biomedical Applications of Single‐Walled Carbon Nanotubes
Cai, W., Gao, T., & Hong, H. (2011) · Wiley eBooks · doi:10.1002/9780470767047.ch20 · Cited by 1
Three-dimensional porous polymer scaffolds for tissue engineering application
Wang, J. (2010) · Figshare
The delivery of IGF-1 for skeletal muscle regeneration within abdominal wall hernias
Falco, E. E. (2009) · University Libraries (University of Maryland)
Zhang, L., Li, Q., Liu, Y., et al. (2011) · InTech eBooks · doi:10.5772/19884
Witthayaprapakorn, C., Thananukul, K., Suttenun, N., Punyamoonwongsa, P., & Molloy, R. (2015) · Progress in Applied Science and Technology
In vitro and in vivo evaluation of novel biodegradable polymer adjuvants for vaccine delivery
Wilson‐Welder, J. H. (2009) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/etd-180810-561 · Cited by 1
Regulation of angiogenesis by adhesive and mechanical cues from the extracellular matrix
Shen, C. J. (2010) · Scholarly Commons (University of Pennsylvania)
King, C. H.-Y. (2007) · DSpace@MIT (Massachusetts Institute of Technology)
Ishiy, F. A. A. (2012) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.41.2012.tde-15102012-163902
Selected polymeric materials for orbital reconstruction
Wentrup‐Byrne, E., & GEORGE, K. (2010) · Elsevier eBooks · doi:10.1533/9781845697433.3.473
Boucher, C. (2010) · PolyPublie (École Polytechnique de Montréal)
Holthoff, W. G., Tan, L. T., Holthoff, E. L., Cardone, E. M., & Bright, F. V. (2009) · Springer eBooks · doi:10.1007/978-0-387-73713-3_16
A Muscle Stent for Damage Repair
Kimes, J., Jaouen, N., Koerner, R., Kondo, T., & Nabity, J. (2005)
Birdi, G. (2014) · University of Birmingham Institutional Research Archive (University of Birmingham)
Design of hybrid fibers for bone tissue engineering
Sachot, N. (2014) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-95602
Soleimani, R. (2013) · Scholarship@Western (Western University)
Cao, H. (2011) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/46428
Fabrication of PLGA/MWNTs/HA Scaffolds for Biomedical Application
Li, W. H. (2013) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.395-396.15
Time programming of material’s properties via self-irradiation phenomena
Luchnikov, V. A. (2009) · Journal of Materials Science · doi:10.1007/s10853-009-3867-z
Sansurin, P., Buakem, K., Kalaithong, W., et al. (2012) · Advanced materials research · doi:10.4028/www.scientific.net/amr.506.53
Diban, N., Haimi, S. P., -Verteeg, L. B., et al. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.08.684
Biodegradable gelatin microcarriers in tissue engineering : In vitro studies on cartilage and bone
Pettersson, S. (2009) · DiVA (Linkoping University) · Cited by 1
The Effects of Thin Patterned Poly(caprolactone) Films on Cell Behavior
Luu, Y., & Tan, J. (2006) · Proceedings of the IEEE Annual Northeast Bioengineering Conference · doi:10.1109/nebc.2006.1629729
“Furthermore, different approaches for creation of scaffolds include solid freeform fabrication, electrospinning, as well as microembossing [8-10].”
BackgroundMethodBiotechnology, 6. Special Applications
Doelle, H. W., Fiechter, A., van Griensven, M., Kasper, C., Pörtner, R., Schlegel, G., Shimizu, S., Stahl, F., Suck, K., Yamada, H., et al. (2009) · Ullmann's Encyclopedia of Industrial Chemistry · doi:10.1002/14356007.n04_n06 · Cited by 1
Bennewitz, N. L. (2004) · SMARTech Repository (Georgia Institute of Technology)
Sachinis, N. P., Chalidis, B. E., Willis-Owen, C. A., et al. (2015) · International Journal of Orthopaedics · doi:10.6051/ijo.v2i5.1164
Tummala, S., Sureshkumar, R., Prakash, A., et al. (2014)
The perspective of polymers use as excipients in solid dosage forms production
Kovalevska, І. V., & Рубан, О. А. (2015) · ScienceRise · doi:10.15587/2313-8416.2015.54891
SÍNTESE E CARACTERIZAÇÃO DE POLIURETANOS BIOESTÁVEIS COM POTENCIAL APLICAÇÃO NA ÁREA CARDIOVASCULAR
de Engenharia, F., Física, F. D. E., & de Química, F. (2012)
BIODEGRADABLE POLY(ESTER-URETHANE) SCAFFOLDS FOR BONE TISSUE ENGINEERING
Kızıltay, A. (2011)
Progenitor Cell Transplantation for Retinal Disease
Klassen, H. J. (2008) · Springer eBooks · doi:10.1007/978-1-4020-8502-4_2
“Examples include polylactic acid (PLA), polylactic-co-glycolic acid (PLGA), polycaprolactone (PCL), and polyglycerol sebacate (PGS), to name a few [ 71 ].”
BackgroundDeveloping a novel biocomposite on selective laser sintering for tissue engineering
Wiria, F. E. (2007) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/5280
Biohajoavien ja biostabiilien polymeerien aiheuttamat pehmytkudosreaktiot
Randén, R. (2007) · Jyväskylä University Digital Archive (University of Jyväskylä) · Cited by 1
Nojehdehian, H., Ekrami, M., Shahriari, M. H., et al. (2016) · Biomedical Research-tokyo
Applied electrokinetics for tissue engineering applications
Tully-Dartez, S. R. (2009)
Antimicrobial peptides engineering and their immobilization studies for catheter coating development
Lim, K. (2015) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/65658 · Cited by 1
DISSERTAÇÃO PARA A OBTENÇÃO DO TÍTULO DE MESTRE EM ENGENHARIA E TECNOLOGIA DE MATERIAIS
de Engenharia, F., Física, F. D. E., & de Química, F. (2009)
Developing vascularization in cardiac decellularized porcine ECM graft using bioreactor
Wang, Y. (2015) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/62522
Assessing viscoelastic properties of chitosan scaffolds and validating sequential and cyclical tests
Ratakonda, S. (2011) · SHAREOK (University of Oklahoma; Oklahoma State University; Central Oklahoma University)
Short communication tendon regeneration and repair: The role of mesenchymal stem cells
Oragui, E., Sachinis, N. P., Hope, N., et al. (2012) · UCL Discovery (University College London)
Voda, A. S., Magniez, K., Salim, N. V., Wong, C. S., & Guo, Q. (2016) · RSC Advances · doi:10.1039/c6ra03718f
Review article Silk as a potential candidate for bone tissue engineering
Mottaghitalab, F., Hosseinkhani, H., & Yang, M. (2015)
ENGINEERING APPROACHES FOR SUPPRESSING DELETERIOUS HOST RESPONSES TO MEDICAL IMPLANTS
McCarthy, C. W. (2015) · Digital Commons - Michigan Tech (Michigan Technological University) · doi:10.37099/mtu.dc.etdr/31
Reinermann, M. (2016) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-5604
Development of tissue-inspired scaffolds : integrating biology with materials science
Luo, B. (2015) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/62517
Sachinis, N., Chalidis, B. E., Willis-Owen, C. A., & Givissis, P. (2015) · International Journal of Orthopaedics · doi:10.17554/j.issn.2311-5106.2015.02.86
Shahbazi, S., Jafari, Y., Moztarzadeh, F., & Sadeghi, G. M. M. (2016) · Polyolefins journal · doi:10.22063/poj.2016.1354
“Poly(propylene fumarate) (PPF) as one of the most important biodegradable polymers is a linear unsaturated polyester consisting of alternating propylene glycol and fumaric acid units [4].”
The Synthesis of Poly(Propylene Fumarate)
Fitch, B. N. (2016)
Evolving Concepts for Use of Stem Cells and Tissue Engineering for Cardiac Regeneration
Jahnavi, S., Santhakumar, R., & Verma, R. S. (2015) · Advances in medical technologies and clinical practice book series · doi:10.4018/978-1-4666-9530-6.ch011
The production and characterisation of cell-laden microparticles for bone tissue engineering
Luetchford, K. (2016) · The University of Bath Online Publications Store (The University of Bath)
Osteochondral Tissue Engineering — Regeneration of Articular Condyle from Mesenchymal Stem Cells
Alhadlaq, A., & Mao, J. J. (2005) · CRC Press eBooks · doi:10.1201/9781420027563.ch35
Future Developments in Prosthetic Surgery
Georgiades, F., & Albersen, M. (2016) · Springer eBooks · doi:10.1007/978-3-319-13859-6_20 · Cited by 1
Shahbazi, S., Jafari, Y., Moztarzadeh, F., et al. (2016)
Adulte Stammzellen des Fettgewebes in der regenerativen Medizin
Pallua, N., Suschek, C. V., & Volkmar, C. M. (2016) · Springer eBooks · doi:10.1007/978-3-662-48849-2_1
Investigating Mechanical Interactions of Cells with Their Environment
Molladavoodi, S. (2015) · UWSpace (University of Waterloo)
Development of functionally graded biomaterial scaffolds using selective laser sintering
Sudarmadji, N. (2010) · doi:10.32657/10356/40749
“66 years [147]), it can be compatibly blended with other polymers such as PLA, PLGA or polyhydroxybutyrate (PHB) to tailor the degradation time [148-149].”
BackgroundFranzone, A., Piccolo, R., & Windecker, S. (2016) · Interventional Cardiology · doi:10.1002/9781118983652.ch35
Lim, J. (2014) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/65562
Smart Biomaterials in Tissue-Engineering Applications
Bajpai, A., Bajpai, J., Saini, R., Agrawal, P., & Tiwari, A. (2016) · doi:10.1201/9781315371559-12 · Cited by 1
Rational scaffold design for skeletal tissue engineering: a modelling and experimental approach
Hendrikson, W. J. (2016) · University of Twente Research Information · doi:10.3990/1.9789462334472
Smart Biomaterials in Biomedical Applications
Bajpai, A., Bajpai, J., Saini, R., Agrawal, P., & Tiwari, A. (2016) · CRC Press eBooks · doi:10.1201/9781315371559-7
Kanitkar, A. (2014) · Louisiana State University · doi:10.31390/gradschool_dissertations.435 · Cited by 1
“Synthetic polymers, on the other hand can be tailored for specific applications, are cheaper than natural scaffolds and can be made on a large scale with desired mechanical properties (Gomes, 2008; Gunatillake and Adhikari, 2003).”
BackgroundInfluentialGonzález, D. L. (2015) · Gredos (University of Salamanca) · doi:10.14201/gredos.128219
Osteochondral Repair Using a Hybrid Implant Composed of Stem Cells and Biomaterial
Shimomura, K., Fujie, H., Hart, D. A., et al. (2017) · Springer eBooks · doi:10.1007/978-3-662-54181-4_53
Wang, W., Mei, L., Wang, F., Pei, B., & Li, X. (2017) · Springer eBooks · doi:10.1007/978-981-10-3554-8_2 · Cited by 1
Performance of Biodegradable Polymers used in Mechanically Loaded Implants
Andersen, L. U., Lauritzen, J. B., & Brøndsted, P. (2013)
Biomaterials Degradation and Bioabsorbability: Biomedical Potentials of Marine Enzymes
Guo, K. W. (2017) · Springer eBooks · doi:10.1007/978-3-319-48281-1_160-1 · Cited by 1
“Theoretically, the hydrolysis of carbonate groups yields two alcohols and CO2, thus eliminating the problem of the acid burst seen in polyesters [44].”
BackgroundA NANOFIBER-STRUCTURED BIOPOLYMER FOR ADVANCED DRUG DELIVERY SYSTEMS
박천권 (2014) · Seoul National University Open Repository (Seoul National University)
Paul, B., Barber, G., Schall, J. D., Sanusei, S., Li, T., & Qu, P. (2017) · International Journal of Orthopaedics · doi:10.17554/j.issn.2311-5106.2017.04.217
Progress in Regenerative Research of the Larynx and Trachea
Omori, K. (2017) · Practica Oto-Rhino-Laryngologica · doi:10.5631/jibirin.111.1
Hybrid bioengineering of tubular constructs for esophagus by melt-drawing and 3D bioprinting
Tan, Y. J. (2018) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/73186 · Cited by 2
Sumaray, C. C., Ngan, E. T., & Reyes, L. Q. (2018) · Defect and diffusion forum/Diffusion and defect data, solid state data. Part A, Defect and diffusion forum · doi:10.4028/www.scientific.net/ddf.382.31
“PEU50, PEU10 and PEU0 are a viscous liquid material which may find applications as injectable hydrogel scaffolds for cell, drug and nucleic acid delivery [15], [16].”
BackgroundChinnasami, H. (2017) · Louisiana State University · doi:10.31390/gradschool_dissertations.4422
Regenerative Medicine Approaches for the Kidney
Ko, I. K., Yoo, J. J., & Atala, A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-809880-6.00066-7
Kuna, V. K. (2018) · Gothenburg University Publications Electronic Archive (Gothenburg University)
Alqahtani, W. S. S. (2017) · Pittsburg State University Digital Commons (Pittsburg State University)
Multifunctional Nanocomposites for Biotherapeutic Applications
Souto, E. B., Fernandes, A. R., Dias-Ferreira, J., da Silva, C. F., Severino, P. B., Martins‐Gomes, C., & Silva, A. M. (2018) · Advances in medical technologies and clinical practice book series · doi:10.4018/978-1-5225-4781-5.ch012
Metadata
- Authors
- CSIRO Molecular Science, B. 1., & Gunatillake, P.
- Corresponding author
- CSIRO Molecular Science, Bag 10, Clayton South MDC, Vic 3169, Australia
- Venue
- European Cells and Materials
- Publisher
- Forum Multimedia Publishing LLC
- Published
- 2003-10-01
- Volume
- 5
- Pages
- 1-16
- ISSN
- 1473-2262 (ISSN-L)
- OpenAlex
- W2106035984
- Cited by
- 1,765
- References
- 97
- Citations by year
- 2026: 43 · 2025: 61 · 2024: 59 · 2023: 80 · 2022: 90 · 2021: 112 · 2020: 102 · 2019: 115 · 2018: 105 · 2017: 128 · 2016: 110 · 2015: 106 · 2014: 110 · 2013: 91 · 2012: 86
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- European Cells and Materials (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
- Keywords
- tissue engineering, polyesters, polyglycolic acid, polylactic acid, polyanhydrides, polyphosphazenes, polyurethane, poly(propylene fumarate), injectable polymers, orthopedic tissue engineering, biodegradation, biocompatibility, degradation products
- MeSH terms
- Biocompatible Materials, Models, Chemical, Polymers, Tissue Engineering
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.