Biodegradable synthetic polymers for tissue engineering
Open accessThe DOI matches its Crossref record; 96 of the 97 references it cites were found in a registry or an index; 1 of the 146 sources its claims cite were checked for support.
Abstract
This review focuses on biodegradable synthetic polymers, discussing synthesis, properties and biodegradability, especially within the polyester family including polylactides.
Overview
CoChat Summary
TL;DR
This review surveys biodegradable synthetic polymers for tissue engineering, emphasizing polyesters (PGA, PLA, PLGA), polylactones, poly(propylene fumarate), polyanhydrides, tyrosine-derived polycarbonates, polyorthoesters, polyurethanes, and polyphosphazenes. It concludes that polyesters dominate clinically, while injectable in situ curable systems such as PPF and photocrosslinkable polyanhydrides are promising but face challenges in biocompatibility, degradation control, and heat generation.
Key findings
- Polyesters are the most studied biodegradable polymers. PGA has 46–50% crystallinity, Tg 36°C, Tm 225°C; in Dexon sutures in vitro, first-stage degradation predominates for 21 days, crystalline degradation takes a further 28 days, and after 49 days weight loss was about 42% with complete loss of mechanical properties.
- PLA/PGA copolymer behavior depends on composition: 25–75% (l)LA/GA and 0–70% (dl)LA/GA are amorphous; 70/30 GA/LA has the highest water uptake, while 50/50 is reported as most unstable to hydrolysis; Vicryl is 8% (l)LA and 92% GA.
- Poly(caprolactone) degrades slowly: homopolymer degradation is on the order of 2–3 years, and PCL with initial average molecular weight 50,000 takes about 3 years for complete in vitro degradation.
- Poly(propylene fumarate) degrades to fumaric acid and propylene glycol; time to 20% original weight loss ranged from 84 days (PPF/β-TCP composite) to over 200 days (PPF/CaSO4 composite). PPF formulations showed maximum curing temperatures of 38–48°C versus 94°C for PMMA cements, curing times of 1–121 min, and compressive strengths of 1–12 MPa.
- Polyanhydrides degrade by surface erosion; poly(sebacic acid) degrades in about 54 days in saline, while poly(1,6-bis(p-carboxyphenoxy)hexane) is estimated at 1 year. Poly[1,6-bis(carboxyphenoxy)hexane] has a Young’s modulus of 1.3 MPa versus human bone at 40–60 MPa; poly(anhydride-co-imides) reached compressive strengths of 50–60 MPa, and photocrosslinked systems showed compressive strengths of 30–40 MPa and tensile strengths of 15–27 MPa.
- Degradable polyurethanes based on lysine diisocyanate showed varied properties: dl-lactide networks were rigid (Tg = 60°C) with ultimate tensile strengths of ~40–70 MPa, caprolactone triol networks were low-modulus elastomers with tensile strengths of 1–4 MPa, and copolymer networks had elongation up to 600% with compressive strengths of 3–25 MPa. In vivo, porous polyurethane artificial skin degraded almost completely 4–8 weeks after implantation in guinea pigs with no adverse tissue reaction.
Methods
- Design: narrative literature review; no primary experimental study or systematic review protocol is reported.
- Data/sample: published literature on biodegradable synthetic polymers, including synthesis, properties, degradation, biocompatibility, and injectable polymer systems; Tables 1–3 summarize polymer properties and precursors.
- Analysis: qualitative synthesis of major polymer classes, their degradation modes/products, mechanical properties, biocompatibility, and potential for injectable tissue-engineering compositions.
Limitations
- Stated: the paper notes that Table 2 data “should be used as a guide only” and that sufficient data are not available to provide a comprehensive list of properties for polyanhydrides, polycarbonates, polyurethanes, and polyphosphazenes.
- Stated: for polyanhydrides, no data are reported about polymer sterilizability and heat generation during polymerization; for degradable polyurethanes, the effect of degradation products and how they are removed from the body are not clearly understood.
- Evident: as a narrative review, it lacks systematic search criteria, study quality appraisal, and meta-analysis, so conclusions depend on the cited literature and may not comprehensively cover all biodegradable polymers or tissue-engineering applications.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
1 Valid · 20 Not valid · 105 Not checked · 89 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“A meniscal replica implanted contained only fibro-cartilage after 18 weeks and decreased the degradation of the articular cartilage.”
What the sources say
- Supportedcites De Groot et al.., 1996 source
The Aliphatic PU network passage (page not provided) reports that articular-cartilage degeneration was less severe with the prosthesis than in meniscectomized control knees. It also says the prostheses contained only fibrocartilage after 18 weeks. Degeneration was reduced, not eliminated. (LLM, conf=0.91)
plainstates a causeSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
In the paper
“The compressive strengths varied between 1 and 12 MPa”
What the sources say
- Not matchedcites Peter et al., 1998a
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Cross-linking characteristics reported for PPF, N-vinyl pyrrolidone (N-VP), benzoyl peroxide, sodium chloride, and TCP indicate that for a range of formulations, the maximum temperature varied within 38 to about 48ºC, compared to 94ºC observed for polymethylmethacrylate (PMMA) cements.”
What the sources say
- Not matchedcites Peter et al., 1998a
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper in Crossref, so there is nothing to check it against.
In the paper
“Based on in-vitro studies, the time required to reach 20% loss in original weight ranged from 84 (PPF/ß-TCP composite) to over 200 days (PPF/CaSO 4 composite)”
What the sources say
- Not matchedcites Peter et al., 1997b
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Not matchedcites Kharas et al., 1997
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“These composite materials exhibit compressive strengths in the range 2 to 30 MPa.”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
94 more claims
Create a free account to see all 215 claims and to verify the 2 references still open.
- It may state two separate claims as one. 62
- Probably not a substantial claim. 76
- The quote only partly states this claim. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Advantages include a tightly controlled manufacturing process, accurate reproducibility, adjustable biodegradability, and a wide variety of both chemical and physical properties.[ 171 ]”
From Unraveling and Harnessing the Immune Response at the Cell–Biomaterial Interface for Tissue Engineering Purposes (2024) · cites this paper as [171]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Polyanhydrides
“Polyanhydrides degrades by surface erosion (Kohn and Langer, 1997) and their main applications are in controlled drug delivery.”
§ Conclusions
“Polyanhydride degrade by bulk erosion and their main applications are in controlled drug delivery.”
Citations
Cites
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741 · cited 4×
“…developments in siloxane-based polyurethanes, which have greater in-vivo stability than conventional polyetherurethanes (e.g., poly(tetramethylene oxide) (PTMO)-based) have provided opportunities for development of a range of medical implants for chronic applications (Gunatillake et al., 2001).”
BackgroundInfluentialBiomaterial developments for bone tissue engineering
Burg, K. J. L., Porter, S., & Kellam, J. F. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00102-2 · Cited by 1,643 · cited 1×
“Polyesters have also been considered for development of tissue engineering applications (Hubbell, 1995; Thomson et al 1995a, Yazemski et al. 1996; Wong and Mooney, 1997), particularly for bone tissue engineering (Kohn and Langer, 1997; Burg et al., 2000).”
BackgroundChandra, R. (1998) · Progress in Polymer Science · doi:10.1016/s0079-6700(97)00039-7 · Cited by 1,462
Biodegradable polymers for use in surgery—polyglycolic/poly(actic acid) homo- and copolymers: 1
Gilding, D. K., & Reed, A. M. (1979) · Polymer · doi:10.1016/0032-3861(79)90009-0 · Cited by 1,345
Biomaterials in Tissue Engineering
Hubbell, J. A. (1995) · Nature Biotechnology · doi:10.1038/nbt0695-565 · Cited by 1,060 · cited 1×
“Polyesters have also been considered for development of tissue engineering applications (Hubbell, 1995; Thomson et al 1995a, Yazemski et al. 1996; Wong and Mooney, 1997), particularly for bone tissue engineering (Kohn and Langer, 1997; Burg et al., 2000).”
BackgroundPolylactic Acid for Surgical Implants
KULKARNI, R. K. (1966) · Archives of Surgery · doi:10.1001/archsurg.1966.01330050143023 · Cited by 841
Evolution of bone transplantation: molecular, cellular and tissue strategies to engineer human bone
Yaszemski, M. J., Payne, R. G., Hayes, W. C., Langer, R., & Mikos, A. G. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85762-0 · Cited by 729
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722 · cited 2×
“For the (l)LA/GA copolymers, resistance to hydrolysis is more pronounced at either end of the copolymers compositions range (Miller et al., 1977; Gilding and Reed, 1979; Reed and Gilding, 1981; Vert et al., 1984).”
BackgroundInjectable biodegradable materials for orthopedic tissue engineering
Temenoff, J. S., & Mikos, A. G. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00108-3 · Cited by 554 · cited 8×
“A number of methods have been reported to prepare PPF, and each results in different polymer properties (Peter et al., 1997a,b, 1999; Temenoff and Mikos 2000).”
BackgroundMethodInfluentialLeong, K. W., Brott, B. C., & Langer, R. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190806 · Cited by 541 · cited 12×
“The polyurethanes ranged from elastomers with elongations at break as high as 780 %, but with low tensile strengths (5.8 to 8.1 MPa).”
BackgroundInfluential
Research works printed but not linked: 5
- Scranton A, Bowman C, Peiffer R, eds. ACS Symposium Series 673; American Chemical Society, Washington DC. pp 189-202.
- Ratner BD, Hoffman AS, Schoen FJ, Lemon JE, eds. Aca- demic Press, San Diego. pp 65-73.
- Lamba NMK, Woodhouse KA, Cooper SL (1998) Poly- urethanes in Biomedical Applications. CRC Press: New York p 205-241.
- Mark JE, Alcock HR, West R (1992) Inorganic Poly- mers. Prentice Hall, Upper Saddle River, NJ. Chapter
- Ng SY, Vandamme T, Tayler MS, Heller J (1997) Syn- thesis and erosion studies of self-catalysed poly(orthoester)s. Macromolecules 30: 770-772.
Cited by
The return of a forgotten polymer—Polycaprolactone in the 21st century
Woodruff, M. A., & Hutmacher, D. W. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.002 · Cited by 4,033
Biodegradable and bioactive porous polymer/inorganic composite scaffolds for bone tissue engineering
Rezwan, K., Chen, Q. Z., Blaker, J. J., & Boccaccini, A. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.039 · Cited by 3,839
“Surface erodative polymers Poly(anhydrides) [31,40,41] 150–200 Surface 25–27 0.”
BackgroundAn Overview of Poly(lactic-co-glycolic) Acid (PLGA)-Based Biomaterials for Bone Tissue Engineering
Gentile, P., Chiono, V., Carmagnola, I., & Hatton, P. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms15033640 · Cited by 1,593
Silk fibroin biomaterials for tissue regenerations
Kundu, B., Rajkhowa, R., Kundu, S. C., & Wang, X. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.043 · Cited by 1,391
A Comparative Review of Natural and Synthetic Biopolymer Composite Scaffolds
Reddy, M. S. B., Ponnamma, D., Choudhary, R., & Sadasivuni, K. K. (2021) · Polymers · doi:10.3390/polym13071105 · Cited by 1,104
Agarwal, S., Curtin, J., Duffy, B., & Jaiswal, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.06.020 · Cited by 955
“PLA is highly biocompatible, semi crystalline and hydrophobic in nature [24].”
BackgroundInfluentialBiocompatibility of hydrogel-based scaffolds for tissue engineering applications
Naahidi, S., Jafari, M., Logan, M., Wang, Y., Yuan, Y., Bae, H., Dixon, B., & Chen, P. (2017) · Biotechnology Advances · doi:10.1016/j.biotechadv.2017.05.006 · Cited by 907
Microbial enzymes: industrial progress in 21st century
Singh, R., Kumar, M., Mittal, A., & Mehta, P. K. (2016) · 3 Biotech · doi:10.1007/s13205-016-0485-8 · Cited by 904
“Biopolymers, such as polyesters, polycarbonates and polyphosphates are used in various biomedical applications, e.g., orthopedic devices, tissue engineering, adhesion barriers, control drug delivery, etc. (Gunatillake and Adhikari 2003; Ulery et al. 2011).”
BackgroundScaffold Fabrication Technologies and Structure/Function Properties in Bone Tissue Engineering
Collins, M. N., Ren, G., Young, K., Pina, S., Reis, R. L., & Oliveira, J. M. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202010609 · Cited by 867
Biodegradable Materials for Bone Repair and Tissue Engineering Applications
Sheikh, Z., Najeeb, S., Khurshid, Z., Verma, V., Rashid, H., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095273 · Cited by 782
“Although PLGA has been extensive used in a variety of clinical applications, its use is limited in the field of orthopedics [262].”
BackgroundBiodegradable Polymers-A Review on Recent Trends and Emerging Perspectives
Luckachan, G. E., & Pillai, C. K. S. (2011) · Journal of Polymers and the Environment · doi:10.1007/s10924-011-0317-1 · Cited by 767
Shirazi, S. F. S., Gharehkhani, S., Mehrali, M., Yarmand, H., Metselaar, H. S. C., Adib Kadri, N., & Osman, N. A. A. (2015) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/16/3/033502 · Cited by 755
“An important synthetic biodegradable polymer material is polycaprolactone (PCL) This material is semi-crystalline with high thermal stability and a degradation period of approximately two years [43].”
BackgroundAdditive manufacturing of biomaterials
Bose, S., Ke, D., Sahasrabudhe, H., & Bandyopadhyay, A. (2018) · Progress in Materials Science · doi:10.1016/j.pmatsci.2017.08.003 · Cited by 738
Polycaprolactone as biomaterial for bone scaffolds: Review of literature
Dwivedi, R., Kumar, S., Pandey, R., Mahajan, A., Nandana, D., Katti, D. S., & Mehrotra, D. (2020) · Journal of Oral Biology and Craniofacial Research · doi:10.1016/j.jobcr.2019.10.003 · Cited by 717
Multifunctional nanostructured PLA materials for packaging and tissue engineering
Armentano, I., Bitinis, N., Fortunati, E., Mattioli, S., Rescignano, N., Verdejo, R., Lopez-Manchado, M. A., & Kenny, J. M. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.05.010 · Cited by 645
“been incorporated in some established applications such as medical implants and drugdelivery systems [14-22].”
BackgroundAbrigo, M., McArthur, S. L., & Kingshott, P. (2014) · Macromolecular Bioscience · doi:10.1002/mabi.201300561 · Cited by 622
Cell membrane-camouflaged nanoparticles for drug delivery
Luk, B. T., & Zhang, L. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.07.019 · Cited by 610
“vide a safe and non-toxic means of delivery for in vivo administration [19,20].”
BackgroundFabrication of Scaffolds for Bone-Tissue Regeneration
Chocholata, P., Kulda, V., & Babuska, V. (2019) · Materials · doi:10.3390/ma12040568 · Cited by 603
“On the other hand, synthetic polymers feature lower values of strength (about 10 GPa) [33], and natural polymers even lower (about 70 MPa) [16].”
BackgroundSelf‐Healing Hydrogels: The Next Paradigm Shift in Tissue Engineering?
Talebian, S., Mehrali, M., Taebnia, N., Pennisi, C. P., Kadumudi, F. B., Foroughi, J., Hasany, M., Nikkhah, M., Akbari, M., Orive, G., et al. (2019) · Advanced Science · doi:10.1002/advs.201801664 · Cited by 602
Graphene and graphene oxide as nanomaterials for medicine and biology application
Priyadarsini, S., Mohanty, S., Mukherjee, S., Basu, S., & Mishra, M. (2018) · Journal of Nanostructure in Chemistry · doi:10.1007/s40097-018-0265-6 · Cited by 570
“Moreover, the degradation of these materials may cause induction of an autocatalytic ester breakdown that lowers the pH, which is not suitable for cell viability [129, 130].”
BackgroundGonzález-Henríquez, C. M., Sarabia-Vallejos, M. A., & Rodriguez-Hernandez, J. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2019.03.001 · Cited by 562
Scaffold: A Novel Carrier for Cell and Drug Delivery
Garg, T., Singh, O., Arora, S., & Murthy, R. S. R. (2012) · Critical Reviews in Therapeutic Drug Carrier Systems · doi:10.1615/critrevtherdrugcarriersyst.v29.i1.10 · Cited by 549
Advances in 3D cell culture technologies enabling tissue‐like structures to be created in vitro
Knight, E., & Przyborski, S. (2015) · Journal of Anatomy · doi:10.1111/joa.12257 · Cited by 530
“Hyaluronic acid has also been used in hydrogels to maintain the growth of hESCs in culture (Gerecht et al. 2007).”
BackgroundPolymeric composites for powder-based additive manufacturing: Materials and applications
Yuan, S., Shen, F., Chua, C. K., & Zhou, K. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.11.001 · Cited by 525
“, polyvinyl alcohol (PVA), poly- ε -caprolactone (PCL), poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV), polylactide (PLA), polyglycolide (PGA), and their co-polymers [69,70].”
Current status of prosthetic bypass grafts: A review
Kannan, R. Y., Salacinski, H. J., Butler, P. E., Hamilton, G., & Seifalian, A. M. (2005) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30247 · Cited by 527
Mondal, D., Griffith, M., & Venkatraman, S. S. (2016) · International Journal of Polymeric Materials and Polymeric Biomaterials · doi:10.1080/00914037.2015.1103241 · Cited by 515
Biodegradable Materials and Metallic Implants—A Review
Prakasam, M., Locs, J., Salma-Ancane, K., Loca, D., Largeteau, A., & Berzina-Cimdina, L. (2017) · Journal of Functional Biomaterials · doi:10.3390/jfb8040044 · Cited by 493
Mondschein, R. J., Kanitkar, A., Williams, C. B., Verbridge, S. S., & Long, T. E. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.06.005 · Cited by 475
Overview of Silk Fibroin Use in Wound Dressings
Farokhi, M., Mottaghitalab, F., Fatahi, Y., Khademhosseini, A., & Kaplan, D. L. (2018) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.04.004 · Cited by 474
Medical applications of membranes: Drug delivery, artificial organs and tissue engineering
Stamatialis, D. F., Papenburg, B. J., Gironés, M., Saiful, S., Bettahalli, S. N. M., Schmitmeier, S., & Wessling, M. (2008) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.09.059 · Cited by 473
“For in-depth nformation on materials used for scaffold fabrication, excellent eviews are available [249,251,256–258].”
BackgroundPolymer carriers for drug delivery in tissue engineering
Sokolsky-Papkov, M., Agashi, K., Olaye, A., Shakesheff, K., & Domb, A. J. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.04.001 · Cited by 452
Samantaray, P. K., Little, A., Haddleton, D. M., McNally, T., Tan, B., Sun, Z., Huang, W., Ji, Y., & Wan, C. (2020) · Green Chemistry · doi:10.1039/d0gc01394c · Cited by 450
Plasma Surface Modification of Biodegradable Polymers: A Review
Morent, R., De Geyter, N., Desmet, T., Dubruel, P., & Leys, C. (2011) · Plasma Processes and Polymers · doi:10.1002/ppap.201000153 · Cited by 434
Hsieh, F.-Y., Lin, H.-H., & Hsu, S.-H. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.08.028 · Cited by 420
Riboldi, S. A., Sampaolesi, M., Neuenschwander, P., Cossu, G., & Mantero, S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.035 · Cited by 408
“Nevertheless, the limited elastic character exhibited by the above-cited scaffolds makes them hardly applicable in dynamic culture experiments performed in bioreactors: they usually exhibit excessively high tensile modulus (in the order of magnitude of 1GPa) and low-yield elongation (3–4%) [21–24].”
BackgroundDesigning of PLA scaffolds for bone tissue replacement fabricated by ordinary commercial 3D printer
Gregor, A., Filová, E., Novák, M., Kronek, J., Chlup, H., Buzgo, M., Blahnová, V., Lukášová, V., Bartoš, M., Nečas, A., et al. (2017) · Journal of Biological Engineering · doi:10.1186/s13036-017-0074-3 · Cited by 406
“Besides this, modification with inorganic compounds or proteins follow in order to tailor physico-chemico properties and to improve cell growth or differentiation [4, 17, 21, 22].”
BackgroundMethodWiria, F. E., Leong, K. F., Chua, C. K., & Liu, Y. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2006.07.008 · Cited by 405
Surface engineered and drug releasing pre-fabricated scaffolds for tissue engineering
Chung, H. J., & Park, T. G. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.015 · Cited by 401
“Biodegradable synthetic polymers widely used for preparing tissue engineering matrices include poly(α-hydroxyester)s, polyanhydrides, and polyorthoesters [20].”
BackgroundApproaches to neural tissue engineering using scaffolds for drug delivery
Willerth, S. M., & Sakiyama-Elbert, S. E. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.014 · Cited by 392
“Poly (glycolic acid)/Poly (lactic acid)/Poly (lactic-co-glycolic acid) Poly (glycolic acid) (PGA), poly (lactic acid) (PLA) are biodegradable synthetic polymers, which can reacted to form the copolymer poly (lactic-co-glycolic acid) [28–30].”
BackgroundA biodegradable porous composite scaffold of PGA/β-TCP for bone tissue engineering
Cao, H., & Kuboyama, N. (2010) · Bone · doi:10.1016/j.bone.2009.09.031 · Cited by 391
“On the other hand, biodegradable synthetic polyesters, such as poly(lactic acid)(PLA), poly(glycolic acid)(PGA) and their copolymer poly(lactide-co-glycolide) (PLGA), have a relatively long history of use in a number of clinical applications [8].”
BackgroundScaffolds for Tissue Engineering and 3D Cell Culture
Carletti, E., Motta, A., & Migliaresi, C. (2011) · Methods in Molecular Biology · doi:10.1007/978-1-60761-984-0_2 · Cited by 387
Biomaterials in cardiac tissue engineering: Ten years of research survey
Chen, Q.-Z., Harding, S. E., Ali, N. N., Lyon, A. R., & Boccaccini, A. R. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.08.001 · Cited by 382
Kannan, R. Y., Salacinski, H. J., Sales, K., Butler, P., & Seifalian, A. M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.006 · Cited by 373
Functionalizing PLGA and PLGA Derivatives for Drug Delivery and Tissue Regeneration Applications
Martins, C., Sousa, F., Araújo, F., & Sarmento, B. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701035 · Cited by 362
Pillai, C. K. S., & Sharma, C. P. (2010) · Journal of Biomaterials Applications · doi:10.1177/0885328210384890 · Cited by 353
“A part of the GA is also excreted by urine [112,134].”
BackgroundThe application of nanofibrous scaffolds in neural tissue engineering
Cao, H., Liu, T., & Chew, S. Y. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.07.009 · Cited by 350
“Polyesters can be degraded by hydrolysis of the ester bond leading to degradation products that can be resorbed through metabolic pathways, causing minimal toxicity to the hosts [28].”
BackgroundBiodegradable polymers—an overview
Doppalapudi, S., Jain, A., Khan, W., & Domb, A. J. (2014) · Polymers for Advanced Technologies · doi:10.1002/pat.3305 · Cited by 348
Ngiam, M., Liao, S., Patil, A. J., Cheng, Z., Chan, C. K., & Ramakrishna, S. (2009) · Bone · doi:10.1016/j.bone.2009.03.674 · Cited by 341
“Yet one of the disadvantages of using such materials is the release of acidic byproducts during degradation [9].”
BackgroundThe biological applications of DNA nanomaterials: current challenges and future directions
Ma, W., Zhan, Y., Zhang, Y., Mao, C., Xie, X., & Lin, Y. (2021) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-021-00727-9 · Cited by 331
Fibrin Gel as an Injectable Biodegradable Scaffold and Cell Carrier for Tissue Engineering
Li, Y., Meng, H., Liu, Y., & Lee, B. P. (2015) · The Scientific World Journal · doi:10.1155/2015/685690 · Cited by 320
“Although synthetic polymers such as polyglycolic acid, polylactic acid, and polyurethanes are widely used to fabricate tissue engineering scaffolds, these synthetic materials are limited by biocompatibility concerns, the inability to support cell attachment, toxic degradation products, and undesirable degradation rate…”
BackgroundPreparation of poly(ε-caprolactone)-based tissue engineering scaffolds by stereolithography
Elomaa, L., Teixeira, S., Hakala, R., Korhonen, H., Grijpma, D. W., & Seppälä, J. V. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.06.039 · Cited by 311
Systemic Review of Biodegradable Nanomaterials in Nanomedicine
Su, S., & Kang, P. M. (2020) · Nanomaterials · doi:10.3390/nano10040656 · Cited by 312
The use of composite materials in modern orthopaedic medicine and prosthetic devices: A review
Scholz, M.-S., Blanchfield, J. P., Bloom, L. D., Coburn, B. H., Elkington, M., Fuller, J. D., Gilbert, M. E., Muflahi, S. A., Pernice, M. F., Rae, S. I., et al. (2011) · Composites Science and Technology · doi:10.1016/j.compscitech.2011.08.017 · Cited by 311
Skeletal muscle tissue engineering
Bach, A. D., Beier, J. P., Stern‐Staeter, J., & Horch, R. E. (2004) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2004.tb00466.x · Cited by 303
Wu, Y., Wan, S., Yang, S., Hu, H., Zhang, C., Lai, J., Zhou, J., Chen, W., Tang, X., Luo, J., et al. (2022) · Journal of Nanobiotechnology · doi:10.1186/s12951-022-01746-6 · Cited by 301
“Subsequently, they are rapidly cleared by RES and MPS, which limits their delivery and distribution [5].”
BackgroundVaccine adjuvants: Current challenges and future approaches
Wilson-Welder, J. H., Torres, M. P., Kipper, M. J., Mallapragada, S. K., Wannemuehler, M. J., & Narasimhan, B. (2009) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21523 · Cited by 296
Gupta, D., Venugopal, J., Prabhakaran, M. P., Dev, V. R. G., Low, S., Choon, A. T., & Ramakrishna, S. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.01.039 · Cited by 295
Print Me An Organ! Why We Are Not There Yet
Ng, W. L., Chua, C. K., & Shen, Y.-F. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2019.101145 · Cited by 287
3D bioprinting of skin: a state-of-the-art review on modelling, materials, and processes
Vijayavenkataraman, S., Lu, W. F., & Fuh, J. Y. H. (2016) · Biofabrication · doi:10.1088/1758-5090/8/3/032001 · Cited by 273
Engineering biomaterials to integrate and heal: The biocompatibility paradigm shifts
Bryers, J. D., Giachelli, C. M., & Ratner, B. D. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24559 · Cited by 271
“A wide variety of biomaterials, synthetic and natural, have been fabricated into porous 3D matrices and are described in many review articles (Badylak, 2007; Gunatillake and Adhikari, 2003; Malafaya et al., 2007).”
BackgroundZhang, P., Hong, Z., Yu, T., Chen, X., & Jing, X. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.08.041 · Cited by 268
Hajiali, F., Tajbakhsh, S., & Shojaei, A. (2018) · Polymer Reviews · doi:10.1080/15583724.2017.1332640 · Cited by 267
Recent Advances in Scaffold Design and Material for Vascularized Tissue‐Engineered Bone Regeneration
Yin, S., Zhang, W., Zhang, Z., & Jiang, X. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801433 · Cited by 262
Mierke, C. T. (2019) · Reports on Progress in Physics · doi:10.1088/1361-6633/ab1628 · Cited by 262
Natural and genetically engineered proteins for tissue engineering
Gomes, S., Leonor, I. B., Mano, J. F., Reis, R. L., & Kaplan, D. L. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.07.003 · Cited by 261
“Besides autologous and allogenic grafts, synthetic materials have also been used for controlled drug delivery systems, scaffolds design and orthopaedic fixation as screws, pins or rods [7,8].”
Bhattarai, D. P., Aguilar, L. E., Park, C. H., & Kim, C. S. (2018) · Membranes · doi:10.3390/membranes8030062 · Cited by 261
Liu, H., Slamovich, E. B., & Webster, T. J. (2006) · International Journal of Nanomedicine · doi:10.2147/nano.2006.1.4.541 · Cited by 258
“Since the 1990s, the applications of poly(glycolic acid) (PGA), poly(lactic acid) (PLA), and their copolymers (PLGA) in bone tissue engineering have been investigated extensively (Gunatillake and Adhikari 2003).”
Polymeric Systems for Bioprinting
Bedell, M. L., Navara, A. M., Du, Y., Zhang, S., & Mikos, A. G. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00834 · Cited by 258
Precheur, H. V. (2007) · Dental Clinics of North America · doi:10.1016/j.cden.2007.03.004 · Cited by 258
Mumme, M., Barbero, A., Miot, S., Wixmerten, A., Feliciano, S., Wolf, F., Asnaghi, A. M., Baumhoer, D., Bieri, O., Kretzschmar, M., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31658-0 · Cited by 257
Divergent immune responses to synthetic and biological scaffolds
Sadtler, K., Wolf, M. T., Ganguly, S., Moad, C. A., Chung, L., Majumdar, S., Housseau, F., Pardoll, D. M., & Elisseeff, J. H. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.11.002 · Cited by 256
Critical evaluation of biodegradable polymers used in nanodrugs
Caballero-George, C., Marin, & Briceño (2013) · International Journal of Nanomedicine · doi:10.2147/ijn.s47186 · Cited by 252
Pharmapolymers in the 21st century: Synthetic polymers in drug delivery applications
Englert, C., Brendel, J. C., Majdanski, T. C., Yildirim, T., Schubert, S., Gottschaldt, M., Windhab, N., & Schubert, U. S. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.07.005 · Cited by 247
Nanotechnology-based biomaterials for orthopaedic applications: Recent advances and future prospects
Kumar, S., Nehra, M., Kedia, D., Dilbaghi, N., Tankeshwar, K., & Kim, K.-H. (2020) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.110154 · Cited by 246
Chen, Q., Zhu, C., & Thouas, G. A. (2012) · Progress in Biomaterials · doi:10.1186/2194-0517-1-2 · Cited by 240
“To address this problem, aliphatic diisocyanates (e.g., lysine diisocyanate (LDI) and 1,4-diisocyanatobutane (BDI)) have been used as the replacements of aromatic diisocyanates (Gunatillake et al. 2003b; Lamba et al. 1998; Pinchuk 1994) in PUs that are designed to be biodegradable.”
BackgroundMethodKuperkar, K., Atanase, L., Bahadur, A., Crivei, I., & Bahadur, P. (2024) · Polymers · doi:10.3390/polym16020206 · Cited by 240
“Similarly, hydroxyalkanoate composites with silicate and borate with acrylic acid matrixes show enhanced mechanical properties [452–464].”
BackgroundRavichandran, R., Venugopal, J. R., Sundarrajan, S., Mukherjee, S., & Ramakrishna, S. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.030 · Cited by 238
“Besides, the scaffold should also be non-cytotoxic and biodegradable to non-toxic products [8].”
BackgroundInjectable Hydrogels for Cardiac Tissue Engineering
Peña, B., Laughter, M., Jett, S., Rowland, T. J., Taylor, M. R. G., Mestroni, L., & Park, D. (2018) · Macromolecular Bioscience · doi:10.1002/mabi.201800079 · Cited by 235
Smart hydrogels as functional biomimetic systems
Lim, H. L., Hwang, Y., Kar, M., & Varghese, S. (2014) · Biomater. Sci. · doi:10.1039/c3bm60288e · Cited by 233
A review of bioceramic porous scaffolds for hard tissue applications: Effects of structural features
Jodati, H., Yılmaz, B., & Evis, Z. (2020) · Ceramics International · doi:10.1016/j.ceramint.2020.03.192 · Cited by 232
Baroli, B. (2009) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21528 · Cited by 226
Kumar, A., Mandal, S., Barui, S., Vasireddi, R., Gbureck, U., Gelinsky, M., & Basu, B. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.01.001 · Cited by 225
Christen, M.-O., & Vercesi, F. (2020) · Clinical, Cosmetic and Investigational Dermatology · doi:10.2147/ccid.s229054 · Cited by 218
“6,7 The present paper therefore shows how PCL, a well-known polymer, has, decades after its fi rst synthesis, led to the creation of an innovative, safe and long-lasting collagen stimulator (PCL fi ller) playing an important role in the expanding fi eld of esthetics.”
Examination of the foreign body response to biomaterials by nonlinear intravital microscopy
Dondossola, E., Holzapfel, B. M., Alexander, S., Filippini, S., Hutmacher, D. W., & Friedl, P. (2016) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0007 · Cited by 215
Poly lactic acid (PLA) polymers: from properties to biomedical applications
Ebrahimi, F., & Ramezani Dana, H. (2022) · International Journal of Polymeric Materials and Polymeric Biomaterials · doi:10.1080/00914037.2021.1944140 · Cited by 214
Aortic valve disease and treatment: The need for naturally engineered solutions
Butcher, J. T., Mahler, G. J., & Hockaday, L. A. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.008 · Cited by 210
“An additional concern is that the end products from the degrading acidic polymers change local pH, causing undesired cell death and differentiation [442].”
BackgroundNanoparticle-Based Therapeutic Approach for Diabetic Wound Healing
Ezhilarasu, H., Vishalli, D., Dheen, S. T., Bay, B.-H., & Srinivasan, D. K. (2020) · Nanomaterials · doi:10.3390/nano10061234 · Cited by 210
Polyglycolic Acid-Induced Inflammation: Role of Hydrolysis and Resulting Complement Activation
Ceonzo, K., Gaynor, A., Shaffer, L., Kojima, K., Vacanti, C. A., & Stahl, G. L. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.301 · Cited by 209
“17,29 For example, approximately 10% of patients treated with rods made of PGA or polylactic acid (PLA) developed an inflammatory response requiring draining, with drainage consisting of a sterile fluid containing degraded PGA or PLA and inflammatory cells.”
Antimicrobial delivery systems for local infection prophylaxis in orthopedic- and trauma surgery
ter Boo, G.-J. A., Grijpma, D. W., Moriarty, T. F., Richards, R. G., & Eglin, D. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.020 · Cited by 209
Díez-Pascual, A. M., & Díez-Vicente, A. L. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b05635 · Cited by 208
Kim, B. S., Kim, H., Gao, G., Jang, J., & Cho, D.-W. (2017) · Biofabrication · doi:10.1088/1758-5090/aa7e98 · Cited by 206
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
Hung, K., Tseng, C., & Hsu, S. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201400018 · Cited by 202
The Foreign Body Response Demystified
Chandorkar, Y., K, R., & Basu, B. (2019) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00252 · Cited by 201
Singh, R. K., Patel, K. D., Lee, J. H., Lee, E.-J., Kim, J.-H., Kim, T.-H., & Kim, H.-W. (2014) · PLoS ONE · doi:10.1371/journal.pone.0091584 · Cited by 201
“Desirable characteristics of these biopolymer nanofiber scaffolds include nanotopology, biodegradability, high porosity, and a high surface area to volume ratio, which facilitates cellular anchorage, migration and proliferation, as well as stimulating differentiation associated with nanotopological cues [25].”
BackgroundHu, C.-M. J., Fang, R. H., Luk, B. T., & Zhang, L. (2014) · Nanoscale · doi:10.1039/c3nr05444f · Cited by 201
Recent Advancement of Biopolymers and Their Potential Biomedical Applications
Biswas, M. C., Jony, B., Nandy, P. K., Chowdhury, R. A., Halder, S., Kumar, D., Ramakrishna, S., Hassan, M., Ahsan, M. A., Hoque, M. E., et al. (2022) · Journal of Polymers and the Environment · doi:10.1007/s10924-021-02199-y · Cited by 202
“1 3 like poly(α-hydroxyesters), polyanhydrides, and polyorthoesters, have found more versatile and diverse biomedical applications owing to their tailorable designs or modifications and extensively used for fabricating tissue engineering matrices [11].”
BackgroundSilk‐Based Biomaterials in Biomedical Textiles and Fiber‐Based Implants
Li, G., Li, Y., Chen, G., He, J., Han, Y., Wang, X., & Kaplan, D. L. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500002 · Cited by 199
Cell colonization in degradable 3D porous matrices
Lawrence, B. J., & Madihally, S. V. (2008) · Cell Adhesion & Migration · doi:10.4161/cam.2.1.5884 · Cited by 197
Ferreira, F. V., Dufresne, A., Pinheiro, I. F., Souza, D. H. S., Gouveia, R. F., Mei, L. H. I., & Lona, L. M. F. (2018) · European Polymer Journal · doi:10.1016/j.eurpolymj.2018.08.045 · Cited by 196
Metadata
- Authors
- CSIRO Molecular Science, B. 1., & Gunatillake, P.
- Corresponding author
- CSIRO Molecular Science, Bag 10, Clayton South MDC, Vic 3169, Australia
- Venue
- European Cells and Materials
- Publisher
- Forum Multimedia Publishing LLC
- Published
- 2003-10-01
- Volume
- 5
- Pages
- 1-16
- ISSN
- 1473-2262 (ISSN-L)
- OpenAlex
- W2106035984
- Cited by
- 1,765
- References
- 97
- Citations by year
- 2026: 43 · 2025: 61 · 2024: 59 · 2023: 80 · 2022: 90 · 2021: 112 · 2020: 102 · 2019: 115 · 2018: 105 · 2017: 128 · 2016: 110 · 2015: 106 · 2014: 110 · 2013: 91 · 2012: 86
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- European Cells and Materials (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
- Keywords
- tissue engineering, polyesters, polyglycolic acid, polylactic acid, polyanhydrides, polyphosphazenes, polyurethane, poly(propylene fumarate), injectable polymers, orthopedic tissue engineering, biodegradation, biocompatibility, degradation products
- MeSH terms
- Biocompatible Materials, Models, Chemical, Polymers, Tissue Engineering
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.