Limitations of Conventional Methods of Self-Monitoring of Blood Glucose
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
OBJECTIVE—Children with type 1 diabetes are usually asked to perform self-monitoring of blood glucose (SMBG) before meals and at bedtime, and it is assumed that if results are in target range, along with HbA1c measurements, then overall glycemic control is adequate. However, the brief glimpses in the 24-h glucose profile provided by SMBG may miss marked glycemic excursions. The MiniMed Continuous Glucose Monitoring System (CGMS) has provided a new method to obtain continuous glucose profiles and opportunities to examine limitations of conventional monitoring. RESEARCH DESIGN AND METHODS—A total of 56 children with type 1 diabetes (age 2–18 years) wore the CGMS for 3 days. Patients entered four fingerstick blood samples into the monitor for calibration and kept records of food intake, exercise, and hypoglycemic symptoms. Data were downloaded, and glycemic patterns were identified. RESULTS—Despite satisfactory HbA1c levels (7.7 ± 1.4%) and premeal glucose levels near the target range, the CGMS revealed profound postprandial hyperglycemia. Almost 90% of the peak postprandial glucose levels after every meal were >180 mg/dl (above target), and almost 50% were >300 mg/dl. Additionally, the CGMS revealed frequent and prolonged asymptomatic hypoglycemia (glucose <60 mg/dl) in almost 70% of the children. CONCLUSIONS—Despite excellent HbA1c levels and target preprandial glucose levels, children often experience nocturnal hypoglycemia and postprandial hyperglycemia that are not evident with routine monitoring. Repeated use of the CGMS may provide a means to optimize basal and bolus insulin replacement in patients with type 1 diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
The MiniMed Continuous Glucose Monitoring System
Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050214078 · Cited by 393
Peters, A. L. (1996) · JAMA · doi:10.1001/jama.1996.03540150048030 · Cited by 303
Performance Evaluation of the MiniMed® Continuous Glucose Monitoring System During Patient Home Use
Gross, T. M., Bode, B. W., Einhorn, D., Kayne, D. M., Reed, J. H., White, N. H., & Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/152091500316737 · Cited by 303
Peters, A. L. (1996) · JAMA · doi:10.1001/jama.276.15.1246 · Cited by 289
The post-prandial state and cardiovascular disease: relevance to diabetes mellitus
Ceriello, A. (2000) · Diabetes/Metabolism Research and Reviews · doi:10.1002/(sici)1520-7560(200003/04)16:2<125::aid-dmrr90>3.0.co;2-4 · Cited by 264
Bode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232 · cited 1×
“in both adults (12) and children (13) have”
BackgroundContinuous Subcutaneous Glucose Monitoring in Children With Type 1 Diabetes
Chase, H. P., Kim, L. M., Owen, S. L., MacKenzie, T. A., Klingensmith, G. J., Murtfeldt, R., & Garg, S. K. (2001) · Pediatrics · doi:10.1542/peds.107.2.222 · Cited by 194
Cited by
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Cryer, P. E., Davis, S. N., & Shamoon, H. (2003) · Diabetes Care · doi:10.2337/diacare.26.6.1902 · Cited by 1,160
Hypoglycaemia: the limiting factor in the glycaemic management of type I and type II diabetes.
Cryer, P. (2002) · Diabetologia · doi:10.1007/s00125-002-0822-9 · Cited by 794
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Giri, B., Dey, S., Das, T., Sarkar, M., Banerjee, J., & Dash, S. K. (2018) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2018.07.157 · Cited by 635
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
A Novel Approach to Continuous Glucose Analysis Utilizing Glycemic Variation
McDonnell, C. M., Donath, S. M., Vidmar, S. I., Werther, G. A., & Cameron, F. J. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.253 · Cited by 358
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
“n events (n seizure or loss of consciousness) 8 (3) 3 (2)”
Performance Evaluation of the MiniMed® Continuous Glucose Monitoring System During Patient Home Use
Gross, T. M., Bode, B. W., Einhorn, D., Kayne, D. M., Reed, J. H., White, N. H., & Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/152091500316737 · Cited by 303
Sensor-Augmented Insulin Pump Therapy: Results of the First Randomized Treat-to-Target Study
Hirsch, I. B., Abelseth, J., Bode, B. W., Fischer, J. S., Kaufman, F. R., Mastrototaro, J., Parkin, C. G., Wolpert, H. A., & Buckingham, B. A. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0068 · Cited by 297
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Yoo, H. J., An, H. G., Park, S. Y., Ryu, O. H., Kim, H. Y., Seo, J. A., Hong, E. G., Shin, D. H., Kim, Y. H., Kim, S. G., et al. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.06.015 · Cited by 244
Raccah, D., Sulmont, V., Reznik, Y., Guerci, B., Renard, E., Hanaire, H., Jeandidier, N., & Nicolino, M. (2009) · Diabetes Care · doi:10.2337/dc09-0750 · Cited by 237
“Consequently, postprandial hyperglycemia and nocturnal hypoglycemia often remain unnoticed even in wellcontrolled individuals (9-11).”
BackgroundXie, X., Doloff, J. C., Yesilyurt, V., Sadraei, A., McGarrigle, J. J., Omami, M., Veiseh, O., Farah, S., Isa, D., Ghani, S., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0273-3 · Cited by 235
Chico, A., Vidal-Ríos, P., Subirà, M., & Novials, A. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1153 · Cited by 235
“It is often difficult to achieve optimal control (3,4), despite intensive insulin therapy and frequent self-monitoring of blood glucose, partly because of the limitations of the glycemic profile obtained from intermittent fingersticks (5).”
BackgroundA View Beyond HbA1c: Role of Continuous Glucose Monitoring
Chehregosha, H., Khamseh, M. E., Malek, M., Hosseinpanah, F., & Ismail-Beigi, F. (2019) · Diabetes Therapy · doi:10.1007/s13300-019-0619-1 · Cited by 235
Young Children with Type 1 Diabetes: Challenges, Research, and Future Directions
Streisand, R., & Monaghan, M. (2014) · Current Diabetes Reports · doi:10.1007/s11892-014-0520-2 · Cited by 216
Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline
Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2756 · Cited by 211
Self-citationContinuous monitoring of circadian glycemic patterns in patients receiving prednisolone for COPD
Burt, M. G., Roberts, G. W., Aguilar-Loza, N. R., Frith, P., & Stranks, S. N. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2729 · Cited by 203
“CGMS provide detailed information regarding nocturnal and postprandial glycemia, whereas standard finger-prick blood glucose monitoring regimens do not (11).”
BackgroundGlucose fluctuations and activation of oxidative stress in patients with type 1 diabetes
Wentholt, I. M. E., Kulik, W., Michels, R. P. J., Hoekstra, J. B. L., & DeVries, J. H. (2007) · Diabetologia · doi:10.1007/s00125-007-0842-6 · Cited by 203
Cerebral ischemic damage in diabetes: an inflammatory perspective
Shukla, V., Shakya, A. K., Perez-Pinzon, M. A., & Dave, K. R. (2017) · Journal of Neuroinflammation · doi:10.1186/s12974-016-0774-5 · Cited by 200
“<65 mg/dl) hypoglycemia in almost 70% of patients [12].”
BackgroundBode, B., Gross, K., Rikalo, N., Schwartz, S., Wahl, T., Page, C., Gross, T., & Mastrototaro, J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504773731285 · Cited by 190
Assessment and management of hypoglycemia in children and adolescents with diabetes
Clarke, W., Jones, T., Rewers, A., Dunger, D., & Klingensmith, G. J. (2008) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2008.00405.x · Cited by 189
Neural Network-Based Real-Time Prediction of Glucose in Patients with Insulin-Dependent Diabetes
Pappada, S. M., Cameron, B. D., Rosman, P. M., Bourey, R. E., Papadimos, T. J., Olorunto, W., & Borst, M. J. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0104 · Cited by 182
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-2081 · Cited by 180
Poolsup, N., Suksomboon, N., & Kyaw, A. M. (2013) · Diabetology & Metabolic Syndrome · doi:10.1186/1758-5996-5-39 · Cited by 179
“In addition, SMBG gives a single instant reading without any information on glucose trends and thus may miss important and significant glucose fluctuations [10-12].”
BackgroundInsulin therapy and hypoglycemia
McCall, A. L. (2012) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2012.03.001 · Cited by 177
Ahern, J. A. H., Boland, E. A., Doane, R., Ahern, J. J., Rose, P., Vincent, M., & Tamborlane, W. V. (2002) · Pediatric Diabetes · doi:10.1034/j.1399-5448.2002.30103.x · Cited by 174
“Preliminary results of studies with continuous glucose monitoring systems have shown that conventional SMBG often misses marked postprandial hyperglycemia and asymptomatic nocturnal hypoglycemia in young people with type 1 diabetes (16, 17).”
Self-citationPrevention of Nocturnal Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension
Buckingham, B., Chase, H. P., Dassau, E., Cobry, E., Clinton, P., Gage, V., Caswell, K., Wilkinson, J., Cameron, F., Lee, H., et al. (2010) · Diabetes Care · doi:10.2337/dc09-2303 · Cited by 169
Cobry, E., McFann, K., Messer, L., Gage, V., VanderWel, B., Horton, L., & Chase, H. P. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0112 · Cited by 164
Diabetes and psychiatric disorders
Balhara, Y. P. (2011) · Indian Journal of Endocrinology and Metabolism · doi:10.4103/2230-8210.85579 · Cited by 163
Hypoglycemia, Diabetes, and Cardiovascular Disease
Snell-Bergeon, J. K., & Wadwa, R. P. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0031 · Cited by 161
Hay, L. C., Wilmshurst, E. G., & Fulcher, G. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503763816427 · Cited by 143
Glycemic Characteristics in Continuously Monitored Patients With Type 1 and Type 2 Diabetes
Bode, B. W., Schwartz, S., Stubbs, H. A., & Block, J. E. (2005) · Diabetes Care · doi:10.2337/diacare.28.10.2361 · Cited by 137
Assessment and management of hypoglycemia in children and adolescents with diabetes
Clarke, W., Jones, T., Rewers, A., Dunger, D., & Klingensmith, G. J. (2009) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2009.00583.x · Cited by 135
Seidu, S., Kunutsor, S. K., Ajjan, R. A., & Choudhary, P. (2024) · Diabetes Care · doi:10.2337/dc23-1520 · Cited by 124
Paterson, M. A., Smart, C. E. M., Lopez, P. E., McElduff, P., Attia, J., Morbey, C., & King, B. R. (2016) · Diabetic Medicine · doi:10.1111/dme.13011 · Cited by 111
Amin, R., Ross, K., Acerini, C. L., Edge, J. A., Warner, J., & Dunger, D. B. (2003) · Diabetes Care · doi:10.2337/diacare.26.3.662 · Cited by 106
“CONCLUSIONS — Use of the Medtronic Minimed CGMS detects glucose variability that is not identified by conventional finger-prick measurements (23) and has been used to previously confirm the high prevalence of childhood hypoglycemia (24).”
Defective awakening response to nocturnal hypoglycemia in patients with type 1 diabetes mellitus
Schultes, B., Jauch-Chara, K., Gais, S., Hallschmid, M., Reiprich, E., Kern, W., Oltmanns, K. M., Peters, A., Fehm, H. L., & Born, J. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040069 · Cited by 100
“Although these episodes appear to be asymptomatic most of the time [7,8,11], hypoglycemic episodes during sleep constitute a particular problem in the management of T1DM, since even a single hypoglycemic episode can reduce awareness of, and neuroendocrine counterregulation against, subsequent hypoglycemia [13,14].”
BackgroundIntrinsic imperfections of endocrine replacement therapy
Romijn, J., Smit, J., & Lamberts, S. (2003) · European Journal of Endocrinology · doi:10.1530/eje.0.1490091 · Cited by 85
“Continuous monitoring with subcutaneous glucosensors indicated that patients with type 1 diabetes mellitus have frequent episodes of both hyper- and hypoglycaemic episodes that are not evident with routine testing ( 7 ).”
BackgroundChetty, V. T., Almulla, A., Odueyungbo, A., & Thabane, L. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.02.014 · Cited by 85
“It should be noted that hypoglycemia unawareness increases with the duration of diabetes [7,8].”
BackgroundHenriksen, M. M., Andersen, H. U., Thorsteinsson, B., & Pedersen-Bjergaard, U. (2018) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2018-00142 · Cited by 57
Cosson, E., Hamo-Tchatchouang, E., Dufaitre-Patouraux, L., Attali, J.-R., Pariès, J., & Schaepelynck-Bélicar, P. (2009) · Diabetes & Metabolism · doi:10.1016/j.diabet.2009.02.006 · Cited by 57
Ahmet, A., Dagenais, S., Barrowman, N. J., Collins, C. J., & Lawson, M. L. (2011) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2011.01.064 · Cited by 42
Kong, S.-Y., & Cho, M.-K. (2024) · Healthcare · doi:10.3390/healthcare12050571 · Cited by 36
Baroreflex sensitivity impairment during hypoglycemia: implications for cardiovascular control
Rao, A. D., Bonyhay, I., Dankwa, J., Baimas-George, M., Kneen, L., Ballatori, S., Freeman, R., & Adler, G. K. (2016) · Diabetes · doi:10.2337/db15-0871 · Cited by 25
“These episodes can last up to 10% of a 24-h period (21).”
BackgroundKim, S. K., Kim, H. J., Kim, T., Hur, K. Y., Kim, S. W., Lee, M.-K., Min, Y.-K., Kim, K.-W., Chung, J. H., & Kim, J. H. (2014) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2014.38.6.449 · Cited by 23
“Previous randomized, controlled trials have compared the effects of CGMS with those of frequent capillary monitoring for improving metabolic control and have studied the effects of additional information obtained from the use of CGMS with SMBG on the improvement of metabolic control [17,18].”
BackgroundContinuous Glucose Monitoring During Pregnancy in Women With Polycystic Ovary Syndrome
Dmitrovic, R., Katcher, H. I., Kunselman, A. R., & Legro, R. S. (2011) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e31822c887f · Cited by 23
Schechter, A., Eyal, O., Zuckerman-Levin, N., Amihai-Ben-Yaacov, V., Weintrob, N., & Shehadeh, N. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0002 · Cited by 12
Meng, R., Gu, T., Yang, F., Liu, J., Sun, Q., & Zhu, D. (2021) · Diabetes Therapy · doi:10.1007/s13300-021-01171-2 · Cited by 11
Metadata
- Authors
- Boland, E., Monsod, T., Delucia, M., Brandt, C. A., Fernando, S., & Tamborlane, W. V.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2001-11-01
- Volume
- 24
- Issue
- 11
- Pages
- 1858-1862
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2112025233
- Cited by
- 423
- References
- 12
- FWCI
- 17.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.