The DOI matches its Crossref record; 138 of the 138 references it cites were found in a registry or an index.
Gait Analysis Using Wearable Sensors
Open accessAbstract
Gait analysis using wearable sensors is an inexpensive, convenient, and efficient manner of providing useful information for multiple health-related applications. As a clinical tool applied in the rehabilitation and diagnosis of medical conditions and sport activities, gait analysis using wearable sensors shows great prospects. The current paper reviews available wearable sensors and ambulatory gait analysis methods based on the various wearable sensors. After an introduction of the gait phases, the principles and features of wearable sensors used in gait analysis are provided. The gait analysis methods based on wearable sensors is divided into gait kinematics, gait kinetics, and electromyography. Studies on the current methods are reviewed, and applications in sports, rehabilitation, and clinical diagnosis are summarized separately. With the development of sensor technology and the analysis method, gait analysis using wearable sensors is expected to play an increasingly important role in clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sensitivity and False Alarm Rate of a Fall Sensor in Long-Term Fall Detection in the Elderly
Kangas, M., Korpelainen, R., Vikman, I., Nyberg, L., & Jämsä, T. (2015) · Gerontology · doi:10.1159/000362720 · Cited by 18,909
OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement
Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.901024 · Cited by 4,933
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
Karantonis, D. M., Narayanan, M. R., Mathie, M., Lovell, N. H., & Celler, B. G. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.856864 · Cited by 1,236
An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo
Lloyd, D. G., & Besier, T. F. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00010-1 · Cited by 1,199
Gait Analysis: Normal and Pathological Function
Perry, J., k, S., & Davids, J. R. (1992) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-199211000-00023 · Cited by 1,121
Analysis of musculoskeletal systems in the AnyBody Modeling System
Damsgaard, M., Rasmussen, J., Christensen, S. T., Surma, E., & de Zee, M. (2006) · Simulation Modelling Practice and Theory · doi:10.1016/j.simpat.2006.09.001 · Cited by 1,031
Recent developments in human motion analysis
Wang, L., Hu, W., & Tan, T. (2003) · Pattern Recognition · doi:10.1016/s0031-3203(02)00100-0 · Cited by 962
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Quaternion-Based Extended Kalman Filter for Determining Orientation by Inertial and Magnetic Sensing
Sabatini, A. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.875664 · Cited by 887
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r01 · Cited by 829
Static and dynamic optimization solutions for gait are practically equivalent
Anderson, F. C., & Pandy, M. G. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00155-x · Cited by 788
Determining Muscle??s Force and Action in Multi-Articular Movement
ZAJAC, F. E., & GORDON, M. E. (1989) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-198900170-00009 · Cited by 738
Gait Analysis Using a Shoe-Integrated Wireless Sensor System
Bamberg, S., Benbasat, A. Y., Scarborough, D. M., Krebs, D. E., & Paradiso, J. A. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2007.899493 · Cited by 737
3-D model-based tracking of humans in action: a multi-view approach
Gavrila, D. M., & Davis, L. S. (1996) · Proceedings CVPR IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1996.517056 · Cited by 702
Wearable Assistant for Parkinson’s Disease Patients With the Freezing of Gait Symptom
Bachlin, M., Plotnik, M., Roggen, D., Maidan, I., Hausdorff, J. M., Giladi, N., & Troster, G. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2036165 · Cited by 693
Abnormality of Gait as a Predictor of Non-Alzheimer's Dementia
Verghese, J., Lipton, R. B., Hall, C. B., Kuslansky, G., Katz, M. J., & Buschke, H. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa020441 · Cited by 690
Gait Assessment in Parkinson's Disease: Toward an Ambulatory System for Long-Term Monitoring
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Dehollain, C., Blanc, Y., Burkhard, P. R., & Aminian, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827933 · Cited by 659
Magnetic Position and Orientation Tracking System
Raab, F., Blood, E., Steiner, T., & Jones, H. (1979) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.1979.308860 · Cited by 614
A method for positioning electrodes during surface EMG recordings in lower limb muscles
Rainoldi, A., Melchiorri, G., & Caruso, I. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.014 · Cited by 610
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 600
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Frequency Parameters of the Myoelectric Signal as a Measure of Muscle Conduction Velocity
Stulen, F. B., & De Luca, C. J. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324738 · Cited by 576
Automatic detection of gait events using kinematic data
O’Connor, C. M., Thorpe, S. K., O’Malley, M. J., & Vaughan, C. L. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.05.016 · Cited by 557
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., & Howard, D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2006190 · Cited by 551
Ambulatory monitoring of freezing of gait in Parkinson’s disease
Moore, S. T., MacDougall, H. G., & Ondo, W. G. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.08.023 · Cited by 526
A threshold-based fall-detection algorithm using a bi-axial gyroscope sensor
Bourke, A. K., & Lyons, G. M. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.12.001 · Cited by 509
A reliable gait phase detection system
Pappas, I. P. I., Popovic, M. R., Keller, T., Dietz, V., & Morari, M. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.928571 · Cited by 495
Comparison of low-complexity fall detection algorithms for body attached accelerometers
Kangas, M., Konttila, A., Lindgren, P., Winblad, I., & Jämsä, T. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.01.003 · Cited by 493
A practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460
Human movement analysis using stereophotogrammetry
Chiari, L., Croce, U. D., Leardini, A., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.04.004 · Cited by 441
Magnetoresistive-based biosensors and biochips
Graham, D. L., Ferreira, H. A., & Freitas, P. P. (2004) · Trends in Biotechnology · doi:10.1016/j.tibtech.2004.06.006 · Cited by 435
The measurement of human motion: A comparison of commercially available systems
Richards, J. G. (1999) · Human Movement Science · doi:10.1016/s0167-9457(99)00023-8 · Cited by 434
Human movement analysis using stereophotogrammetryPart 1: theoretical background
CAPPOZZO, A., DELLACROCE, U., LEARDINI, A., & CHIARI, L. (2005) · Gait & Posture · doi:10.1016/s0966-6362(04)00025-6 · Cited by 398
Driven gait orthosis for improvement of locomotor training in paraplegic patients
Colombo, G., Wirz, M., & Dietz, V (2001) · Spinal Cord · doi:10.1038/sj.sc.3101154 · Cited by 396
Wearable sensors/systems and their impact on biomedical engineering
Bonato, P. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213622 · Cited by 382 · cited 1×
“force sensors, strain gauges, inclinometers, goniometers, and so on, can measure various characteristics of the human gait [20,21].”
BackgroundGait recognition: a challenging signal processing technology for biometric identification
Boulgouris, N. V., Hatzinakos, D., & Plataniotis, K. N. (2005) · IEEE Signal Processing Magazine · doi:10.1109/msp.2005.1550191 · Cited by 362
Patient specific ankle-foot orthoses using rapid prototyping
Mavroidis, C., Ranky, R. G., Sivak, M. L., Patritti, B. L., DiPisa, J., Caddle, A., Gilhooly, K., Govoni, L., Sivak, S., Lancia, M., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-1 · Cited by 361
Jensen, J., Lundin-Olsson, L., Nyberg, L., & Gustafson, Y. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-136-10-200205210-00008 · Cited by 359
Methods for gait event detection and analysis in ambulatory systems
Rueterbories, J., Spaich, E. G., Larsen, B., & Andersen, O. K. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.03.007 · Cited by 350
Clinical gait analysis: A review
Whittle, M. W. (1996) · Human Movement Science · doi:10.1016/0167-9457(96)00006-1 · Cited by 349
Range of joint motion and disability in patients with osteoarthritis of the knee or hip
Steultjens, M. P. M., Dekker, J., van Baar, M. E., Oostendorp, R. A. B., & Bijlsma, J. W. J. (2000) · Rheumatology · doi:10.1093/rheumatology/39.9.955 · Cited by 327
Accelerometry—A technique for the measurement of human body movements
Morris, J. R. W. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90029-8 · Cited by 325
Inclination measurement of human movement using a 3-D accelerometer with autocalibration
Luinge, H. J., & Veltink, P. H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.822759 · Cited by 307
Casadio, M., Morasso, P. G., & Sanguineti, V. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.005 · Cited by 302
Kim, C. M., & Eng, J. J. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2003.07.002 · Cited by 301
Milne, A. D., Chess, D. G., Johnson, J. A., & King, G. J. W. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)83335-5 · Cited by 299
An inertial and magnetic sensor based technique for joint angle measurement
O’Donovan, K. J., Kamnik, R., O’Keeffe, D. T., & Lyons, G. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.12.010 · Cited by 281
Capturing human motion using body‐fixed sensors: outdoor measurement and clinical applications
Aminian, K., & Najafi, B. (2004) · Computer Animation and Virtual Worlds · doi:10.1002/cav.2 · Cited by 280
Foot pressure distribution during walking in young and old adults
Hessert, M. J., Vyas, M., Leach, J., Hu, K., Lipsitz, L. A., & Novak, V. (2005) · BMC Geriatrics · doi:10.1186/1471-2318-5-8 · Cited by 272
Wearable, Redundant Fabric-Based Sensor Arrays for Reconstruction of Body Segment Posture
Lorussi, F., Rocchia, W., Scilingo, E. P., Tognetti, A., & De Rossi, D. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.837498 · Cited by 265
Development of a wearable sensor system for quantitative gait analysis
Liu, T., Inoue, Y., & Shibata, K. (2009) · Measurement · doi:10.1016/j.measurement.2009.02.002 · Cited by 262
Self-citationGhoussayni, S., Stevens, C., Durham, S., & Ewins, D. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2003.10.001 · Cited by 244
Ambulatory monitoring of physical activities in patients with Parkinson’s disease
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Burkhard, P. R., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.896591 · Cited by 217
Piezoresistivity of a short fiber/elastomer matrix composite
Taya, M., Kim, W. J., & Ono, K. (1998) · Mechanics of Materials · doi:10.1016/s0167-6636(97)00064-1 · Cited by 216
An Update on the Treatment of Gait Problems in Cerebral Palsy
Gage, J. R., & Novacheck, T. F. (2001) · Journal of Pediatric Orthopaedics, Part B · doi:10.1097/00009957-200110000-00001 · Cited by 202
Determination of simple thresholds for accelerometry-based parameters for fall detection
Kangas, M., Konttila, A., Winblad, I., & Jamsa, T. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352552 · Cited by 202
Strain-sensing fabrics for wearable kinaesthetic-like systems
Scilingo, E. P., Lorussi, F., Mazzoldi, A., & De Rossi, D. (2003) · IEEE Sensors Journal · doi:10.1109/jsen.2003.815771 · Cited by 200
Finley, M. A., & Lee, R. Y. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2003.50087 · Cited by 197
Gait posture estimation using wearable acceleration and gyro sensors
Takeda, R., Tadano, S., Natorigawa, A., Todoh, M., & Yoshinari, S. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.07.016 · Cited by 197
Miyazaki, S. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.605434 · Cited by 194
Real-time gait event detection using wearable sensors
Hanlon, M., & Anderson, R. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.07.128 · Cited by 187
Ambulatory Assessment of Ankle and Foot Dynamics
Schepers, H. M., Koopman, H. F. J. M., & Veltink, P. H. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889769 · Cited by 186
Use of pressure insoles to calculate the complete ground reaction forces
Forner Cordero, A., Koopman, H. J. F. M., & van der Helm, F. C. T. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.016 · Cited by 177
Fall Prediction Index for Patients in Stroke Rehabilitation
Nyberg, L., & Gustafson, Y. (1997) · Stroke · doi:10.1161/01.str.28.4.716 · Cited by 175
POPE, M. H., BEVINS, T., WILDER, D. G., & FRYMOYER, J. W. (1985) · Spine · doi:10.1097/00007632-198509000-00009 · Cited by 171
Application of tilt sensors in functional electrical stimulation
Dai, R., Stein, R. B., Andrews, B. J., James, K. B., & Wieler, M. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506403 · Cited by 167
Real-time gait event detection for paraplegic FES walking
Skelly, M., & Chizeck, H. J. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.918277 · Cited by 165
Ambulatory measurement of ground reaction forces
Veltink, P. H., Liedtke, C., Droog, E., & van der Kooij, H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847359 · Cited by 161
Gait Event Detection on Level Ground and Incline Walking Using a Rate Gyroscope
Catalfamo, P., Ghoussayni, S., & Ewins, D. (2010) · Sensors · doi:10.3390/s100605683 · Cited by 159
Sensitivity and specificity of fall detection in people aged 40 years and over
Kangas, M., Vikman, I., Wiklander, J., Lindgren, P., Nyberg, L., & Jämsä, T. J. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2008.12.008 · Cited by 156
Mobility assessment in older people: new possibilities and challenges
Zijlstra, W., & Aminian, K. (2007) · European Journal of Ageing · doi:10.1007/s10433-007-0041-9 · Cited by 155
A treadmill ergometer for three-dimensional ground reaction forces measurement during walking
Belli, A., Bui, P., Berger, A., GEYSSANT, A., & Lacour, J.-R. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00125-1 · Cited by 153
Static optimization of muscle forces during gait in comparison to EMG-to-force processing approach
Heintz, S., & Gutierrez-Farewik, E. M. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2006.09.074 · Cited by 152
Automatic Detection of Temporal Gait Parameters in Poststroke Individuals
Lopez‐Meyer, P., Fulk, G. D., & Sazonov, E. E. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2112773 · Cited by 148
Heel to toe motion characteristics in Parkinson patients during free walking
Kimmeskamp, S., & Hennig, E. M. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(01)00069-9 · Cited by 142
Recent developments and trends in biomedical sensors
Engin, M., Demirel, A., Engın, E. Z., & Fedakar, M. (2004) · Measurement · doi:10.1016/j.measurement.2004.11.002 · Cited by 142
Bachmann, E. R. (2000) · Cited by 140
Davis, R. B. (1988) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.7933 · Cited by 137
The evolution of clinical gait analysis part III – kinetics and energy assessment
Sutherland, D. H. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2004.07.008 · Cited by 136
Saremi, K., Marehbian, J., Yan, X., Régnaux, J.-P., Elashoff, R. E., Bussel, B., & Dobkin, B. H. (2006) · Neurorehabilitation and neural repair · doi:10.1177/1545968306287171 · Cited by 133
Stair climbing detection during daily physical activity using a miniature gyroscope
Coley, B., Najafi, B., Paraschiv-Ionescu, A., & Aminian, K. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2004.08.008 · Cited by 131
Real-time gait assessment utilizing a new way of accelerometry
Willemsen, A., van Alste, J. A., & Boom, H. B. K. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90033-y · Cited by 130
Gait Analysis Alters Decision-Making in Cerebral Palsy
Cook, R. E., Schneider, I., Hazlewood, M. E., Hillman, S. J., & Robb, J. (2003) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-200305000-00004 · Cited by 126
Sensing Movement: Microsensors for Body Motion Measurement
Zeng, H., & Zhao, Y. (2011) · Sensors · doi:10.3390/s110100638 · Cited by 124
Evaluation of instrumented shoes for ambulatory assessment of ground reaction forces
Liedtke, C. B., Fokkenrood, S. A. W., Menger, J. T., van der Kooij, H., & Veltink, P. H. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2006.07.017 · Cited by 117
Savelberg, H. H. C. M., & Lange, A. L. H. D. (1999) · Clinical Biomechanics · doi:10.1016/s0268-0033(99)00036-4 · Cited by 114
An EMG-to-force processing approach for determining ankle muscle forces during normal human gait
Bogey, R. A., Perry, J., & Gitter, A. J. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.851768 · Cited by 114
Liu, T., INOUE, Y., & SHIBATA, K. (2010) · Sensors · doi:10.3390/s101110240 · Cited by 113
Self-citationGhasemzadeh, H. G., & Jafari, R. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2048205 · Cited by 113
Pincivero, D. M., Gandhi, V. V., Timmons, M. K., & Coelho, A. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.11.023 · Cited by 112
Skeletal Muscle Structure and Function
McNally, E. M., Lapidos, K. A., & Wheeler, M. T. (2007) · Humana Press eBooks · doi:10.1007/978-1-59259-963-9_67 · Cited by 106
Calibration of position and angular data from a magnetic tracking device
Day, J. S., Murdoch, D. J., & Dumas, G. A. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00044-0 · Cited by 100
Bächlin, M., Roggen, D., Tröster, G., Plotnik, M., Inbar, N., Meidan, I., Herman, T., Brozgol, M., Shaviv, E., Giladi, N., et al. (2009) · International Symposium on Wearable Computers · doi:10.1109/iswc.2009.14 · Cited by 100
deFOG — A real time system for detection and unfreezing of gait of Parkinson’s patients
Jovanov, E., Wang, E. Q., Verhagen, L., Fredrickson, M., & Fratangelo, R. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334257 · Cited by 98
Lower extremity angle measurement with accelerometers-error and sensitivity analysis
Willemsen, A., Frigo, C., & Boom, H. B. K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.137284 · Cited by 92
Measuring spinal motion in rowers: the use of an electromagnetic device
Bull, A. M. J., & McGregor, A. H. (2000) · Clinical Biomechanics · doi:10.1016/s0268-0033(00)00043-7 · Cited by 89
M, D., Palange, E., Nicola, F. D., Bucci, G., & Ciancetta, F. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2008.925336 · Cited by 88
Kinematical analysis and measurement of sports form
Watanabe, K., & HOKARI, M. (2006) · IEEE Transactions on Systems Man and Cybernetics - Part A Systems and Humans · doi:10.1109/tsmca.2005.855777 · Cited by 82
Mills, P., Morrison, S., Lloyd, D. G., & Barrett, R. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.06.017 · Cited by 81
Turcot, K., Aïssaoui, R., Boivin, K., Pelletier, M., Hagemeister, N., & de Guise, J. A. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912428 · Cited by 79
Stokić, D. S., Horn, T. S., Ramshur, J. M., & Chow, J. W. (2009) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e3181a5b1ec · Cited by 78
Determining the centre of pressure during walking and running using an instrumented treadmill
Verkerke, G. J., Hof, A. L., Zijlstra, W., et al. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.08.015 · Cited by 77
Automatic detection of gait events: a case study using inductive learning techniques
Kirkwood, C. A., Andrews, B. J., & Mowforth, P. (1989) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(89)90046-0 · Cited by 76
Assessment of human locomotion by using an insole measurement system and artificial neural networks
Zhang, K., Sun, M., Lester, D. K., Pi-Sunyer, X., Boozer, C. N., & Longman, R. W. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.07.036 · Cited by 75
Lai, D. T. H., Levinger, P., Begg, R. K., Gilleard, W., & Palaniswami, M. S. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2022927 · Cited by 73
Combining body sensors and visual sensors for motion training
Kwon, D. Y., & Groß, M. H. (2005) · International Conference on Advances in Computer Entertainment Technology (ACE) · doi:10.1145/1178477.1178490 · Cited by 71
Ayrulu, B., & Barshan, B. (2011) · Sensors · doi:10.3390/s110201721 · Cited by 68
Classifying Human Leg Motions with Uniaxial Piezoelectric Gyroscopes
Tunçel, O., Altun, K., & Barshan, B. (2009) · Sensors · doi:10.3390/s91108508 · Cited by 67
Filho, M. C. D. M., Yoshida, R., Carvalho, W. D. S., Stein, H. E., & Novo, N. F. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.01.013 · Cited by 66
Application of wearable sensors for human gait analysis using fuzzy computational algorithm
Alaqtash, M., Yu, H., Brower, R. D., Abdelgawad, A. H. K., & Sarkodie-Gyan, T. (2011) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2011.04.010 · Cited by 65
Body segment position reconstruction and posture classification by smart textiles
Tognetti, A., Bartalesi, R., Lorussi, F., & Rossi, D. D. (2007) · Transactions of the Institute of Measurement and Control · doi:10.1177/0142331207069487 · Cited by 64
Bourke, A. K., van de Ven, P. W. J., Gamble, M., O'Connor, R., Murphy, K., Bogan, E., McQuade, E., Finucane, P. M., OLaighin, G. M., & Nelson, J. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626364 · Cited by 57
A Wearable Sensor Network for Gait Analysis: A Six-Day Experiment of Running Through the Desert
Chelius, G., Braillon, C., Pasquier, M., et al. (2011) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2161324 · Cited by 53
Kinematics of rotational mobilisation of the lumbar spine
Lee, R. Y. W. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(01)00036-5 · Cited by 52
Tracking people in three dimensions using a hierarchical model of dynamics
Karaulova, I. A., Hall, P. M., & Marshall, A. D. (2002) · Image and Vision Computing · doi:10.1016/s0262-8856(02)00059-8 · Cited by 48
Observing Recovery from Knee-Replacement Surgery by Using Wearable Sensors
Atallah, L., Jones, G. G., Ali, R., Leong, J., Lo, B. P. L., & Yang, G. (2011) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2011.10 · Cited by 48
Kim, K. J., Chang, Y. M., Yoon, S., & Kim, H. J. (2009) · Integrated ferroelectrics · doi:10.1080/10584580903324493 · Cited by 47
Automatic identification of gait events using an instrumented sock
Preece, S. J., Kenney, L. P. J., Major, M. J., Dias, T., Lay, E., & Fernandes, B. T. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-32 · Cited by 47
The study of kinematic transients in locomotion using the integrated kinematic sensor
Wu, G., & Ladin, Z. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.536775 · Cited by 46
Woodburn, J., Turner, D. E., Helliwell, P., & Barker, S. (1999) · Lara D. Veeken · doi:10.1093/rheumatology/38.12.1260 · Cited by 43
Robotic-assessment of walking in individuals with gait disorders
Hidler, J. M. (2005) · doi:10.1109/iembs.2004.1404336 · Cited by 41
Design and test of a long-term fall detection system incorporated into a custom vest for the elderly
Bourke, A. K., van de Ven, P. W. J., Chaya, A. E., et al. (2008) · IET Irish Signals and Systems Conference (ISSC) · doi:10.1049/cp:20080680 · Cited by 33
A new system for three-dimensional gait recording using electromagnetic tracking
Kobayashi, K., Gransberg, L., KNUTSSON, E., & Nolén, P. (1997) · Gait & Posture · doi:10.1016/s0966-6362(96)01102-2 · Cited by 33
Neural Network Gait Classification for On-Body Inertial Sensors
Hanson, M., Powell, H. C., Jr., Barth, A. T., et al. (2009) · International Workshop on Wearable and Implantable Body Sensor Networks (BSN) · doi:10.1109/bsn.2009.48 · Cited by 30
Erni, T., & Colombo, G. (1998) · Electroencephalography and Clinical Neurophysiology/Electromyography and Motor Control · doi:10.1016/s0924-980x(98)00005-8 · Cited by 27
A multimodal approach for insole motion measurement and analysis
Jagoš, H., Oberzaucher, J., Reichel, M., Zagler, W. L., & Hlauschek, W. (2010) · Procedia Engineering · doi:10.1016/j.proeng.2010.04.118 · Cited by 24
Bourke, A. K., van de Ven, P. W. J., Chaya, A. E., OLaighin, G. M., & Nelson, J. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649793 · Cited by 23
Han, J., Jeon, H. S., Yi, W. J., Jeon, B. S., & Park, K. S. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0521-5 · Cited by 20
Efficient FES triggering applying Kalman filter during sensory supported treadmill walking
Cikajlo, I., Matjačić, Z., & Bajd, T. (2008) · Journal of Medical Engineering & Technology · doi:10.1080/03091900601029627 · Cited by 20
Flexible angular sensor [and biomechanical application]
Roduit, R., Besse, P.-A., & Micallef, J. P. (1998) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.744661 · Cited by 19
Kinetics Analysis of Ankle, Knee and Hip Joints Using a Wearable Sensor System
Zheng, R., Liu, T., INOUE, Y., SHIBATA, K., & Liu, K. (2008) · Journal of Biomechanical Science and Engineering · doi:10.1299/jbse.3.343 · Cited by 19
Self-citationJoint moments: Evaluation of ground reaction, inertial and segmental weight effects
Davis, R. B., Õunpuu, S., & DeLuca, P. A. (1994) · Gait & Posture · doi:10.1016/0966-6362(94)90062-0 · Cited by 14
Roduit, R., & Micallef, J. (1998) · Cited by 12
Ambulatory Hip Angle Estimation using Gaussian Particle Filter
Zhang, Z., Huang, Z., & Wu, J. (2009) · Journal of Signal Processing Systems · doi:10.1007/s11265-009-0373-0 · Cited by 11
Development of a Telemetric Goniometer
Laskoski, G. T., Martins, L. D., Pichorim, S. F., et al. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03889-1_61 · Cited by 7
Method for monitoring acceleration of the trunk during gait
Villanueva, D., Trujillo, A. P., Fermon, E., Cardiel, E., & Hedz, P.-R. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2002.1106638 · Cited by 6
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Muro-de-la-Herran, A., Garcia-Zapirain, B., & Mendez-Zorrilla, A. (2014) · Sensors · doi:10.3390/s140203362 · Cited by 1,172
Wearable Flexible Sensors: A Review
Nag, A., Mukhopadhyay, S. C., & Kosel, J. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2705700 · Cited by 526
Photonic crystals: emerging biosensors and their promise for point-of-care applications
Inan, H., Poyraz, M., Inci, F., Lifson, M. A., Baday, M., Cunningham, B. T., & Demirci, U. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00206d · Cited by 480
Zhu, M., Shi, Q., He, T., Yi, Z., Ma, Y., Yang, B., Chen, T., & Lee, C. (2019) · ACS Nano · doi:10.1021/acsnano.8b08329 · Cited by 411
Metadata
- Authors
- Tao, W., Liu, T., Zheng, R., & Feng, H.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2012-02-16
- Volume
- 12
- Issue
- 2
- Pages
- 2255-2283
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2158764002
- Cited by
- 1,165
- References
- 138
- FWCI
- 23.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.