Wearables in Medicine

Open access
Yetisen, Ali K., Martinez‐Hurtado, Juan Leonardo, Ünal, Barış, Khademhosseini, Ali, Butt, Haider · 2018 · Advanced Materials

The DOI matches its Crossref record; 258 of the 258 references it cites were found in a registry or an index; 59 of the 218 sources its claims cite were checked for support.

Abstract

Wearables as medical technologies are becoming an integral part of personal analytics, measuring physical status, recording physiological parameters, or informing schedule for medication. These continuously evolving technology platforms do not only promise to help people pursue a healthier life style, but also provide continuous medical data for actively tracking metabolic status, diagnosis, and treatment. Advances in the miniaturization of flexible electronics, electrochemical biosensors, microfluidics, and artificial intelligence algorithms have led to wearable devices that can generate real-time medical data within the Internet of things. These flexible devices can be configured to make conformal contact with epidermal, ocular, intracochlear, and dental interfaces to collect biochemical or electrophysiological signals. This article discusses consumer trends in wearable electronics, commercial and emerging devices, and fabrication methods. It also reviews real-time monitoring of vital signs using biosensors, stimuli-responsive materials for drug delivery, and closed-loop theranostic systems. It covers future challenges in augmented, virtual, and mixed reality, communication modes, energy management, displays, conformity, and data safety. The development of patient-oriented wearable technologies and their incorporation in randomized clinical trials will facilitate the design of safe and effective approaches.

Overview

CoChat Summary

## TL;DR

This review surveys wearable technologies in medicine, focusing on sensing, data handling, drug delivery, and clinical translation. It argues that wearables are moving toward real-time, closed-loop patient care, but major barriers remain in calibration, power, biocompatibility, data security, and clinical validation.

## Key findings

  • The paper frames wearables as medical technologies for continuous tracking of physical and biochemical status, with interfaces spanning epidermal, ocular, intracochlear, and dental sites.
  • It reports several performance examples from the literature, including embroidered textile glucose sensors that shifted current by 0.9 mA as glucose increased from 0 to 40 mmol L−1, and textiled Na+/K+ sensors with a limit of detection of ≈10−5 m.
  • For in vivo sensing, it notes a saliva bacteria-detection device with a detection limit of ≈100 cells, and contact-lens glucose sensing in rabbits with a 10 min delay and in vivo sensitivity of 40 × 10−6 m.
  • Market figures cited in the paper include 125 million wearable device units sold in 2016 (55% more than 2015), projected sales of 237 million by 2020, and $33B in industry revenue in 2016.

## Methods

  • This is a narrative review of wearable medicine, covering consumer trends, commercial and emerging devices, fabrication methods, biosensing, drug delivery, closed-loop theranostics, and regulatory issues.
  • The paper synthesizes examples drawn from prior studies across device classes such as textiles, tattoos, contact lenses, shoes, hearing aids, glucose monitors, and virtual reality systems; no new dataset is reported.
  • Its analysis is descriptive and comparative, using reported device metrics, market statistics, and regulatory examples rather than a single experimental protocol.

## Limitations

  • The paper states that limitations in existing sensing technologies include sensor drift from biofouling, frequent calibration, biweekly replacement, and relatively high cost; it also notes that real-time signal/data processing requires continuous power.
  • It states that wearable treatment approaches are limited by poor integration and miniaturization, low biocompatibility, insufficient conformal contact, inefficient energy use, and short lifetime.
  • It explicitly says that controlled studies are required for performance evaluation, and that the effects of continuous electromagnetic exposure from wearables on human tissues “warrant further research.”
  • Evident from the text: the paper is a review, so its conclusions depend on previously published studies rather than a unified prospective clinical dataset.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1002/adma.201706910

Cites

258 of 258 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Wearables devices for medical applications. a) Wearable devices (in vitro) have loose or conformal contact with the skin, or worn/inserted through body orifices. The most common interface is loose skin contact wearables, which measure electrophysiological signal via optics and electrodes. b) Information transfer from wearables. The data collected from wearable devices can be transmitted to the Internet or other devices via a body area network, Bluetooth, Wi‐Fi, LTE, 3G, 4G, or 5G connection. The medical data can be sent to a healthcare provider to receive therapeutic feedback or acted upon automatically by other devices in the network.
Figure 1 Wearables devices for medical applications. a) Wearable devices (in vitro) have loose or conformal contact with the skin, or worn/inserted through body orifices. The most common interface is loose skin contact wearables, which measure electrophysiological signal via optics and electrodes. b) Information transfer from wearables. The data collected from wearable devices can be transmitted to the Internet or other devices via a body area network, Bluetooth, Wi‐Fi, LTE, 3G, 4G, or 5G connection. The medical data can be sent to a healthcare provider to receive therapeutic feedback or acted upon automatically by other devices in the network.CC BY · PubMed Central
Figure 2 Applications of wearable devices. a) Electronic tattoos conformally attached to the skin via van der Waals forces. Reproduced with permission.15 Copyright 2011, American Association for the Advancement of Science. b) A compliant modulus sensor comprising nanoribbons of lead zirconate titanate in arrays of mechanical actuators and sensors. The upper and lower insets show the interconnected array and actuator/sensing regions. Reproduced with permission.16 Copyright 2015, Nature Publishing Group. c) A wearable device that can monitor muscle activity, store data, and wirelessly communicate data closed‐loop therapy. The inset shows a wearable RAM array (10 × 10) on the patch. Reproduced with permission.19 Copyright 2014, Nature Publishing Group. d) A wearable wristband consisting of electrochemical sensors for the quantification of concentrations of glucose, lactate, electrolytes (Na+, K+ ions), and temperature for application in real‐time perspiration analysis. Reproduced with permission.28 Copyright 2016, Nature Publishing Group. e) Prosthetic skin featuring pressure, strain, humidity and temperature sensors, as well as electroresistive heaters for creating a skin‐like perception. The inset shows the prosthetic skin under ≈20% strain. Reproduced with permission.32 Copyright 2014, Nature Publishing Group. f) A antimicrobial peptide‐functionalized graphene sensor on a tooth for wireless detection of bacteria. Reproduced with permission.47 Copyright 2012, Nature Publishing Group.
Figure 2 Applications of wearable devices. a) Electronic tattoos conformally attached to the skin via van der Waals forces. Reproduced with permission.15 Copyright 2011, American Association for the Advancement of Science. b) A compliant modulus sensor comprising nanoribbons of lead zirconate titanate in arrays of mechanical actuators and sensors. The upper and lower insets show the interconnected array and actuator/sensing regions. Reproduced with permission.16 Copyright 2015, Nature Publishing Group. c) A wearable device that can monitor muscle activity, store data, and wirelessly communicate data closed‐loop therapy. The inset shows a wearable RAM array (10 × 10) on the patch. Reproduced with permission.19 Copyright 2014, Nature Publishing Group. d) A wearable wristband consisting of electrochemical sensors for the quantification of concentrations of glucose, lactate, electrolytes (Na+, K+ ions), and temperature for application in real‐time perspiration analysis. Reproduced with permission.28 Copyright 2016, Nature Publishing Group. e) Prosthetic skin featuring pressure, strain, humidity and temperature sensors, as well as electroresistive heaters for creating a skin‐like perception. The inset shows the prosthetic skin under ≈20% strain. Reproduced with permission.32 Copyright 2014, Nature Publishing Group. f) A antimicrobial peptide‐functionalized graphene sensor on a tooth for wireless detection of bacteria. Reproduced with permission.47 Copyright 2012, Nature Publishing Group.CC BY · PubMed Central
Figure 3 Transient electronics. a) Disintegrable electronics comprising iron as electrodes at various stages of disintegration in a pH 4.6 buffer solution (scale bars = 5 mm). Reproduced with permission.90 Copyright 2017, United States National Academy of Sciences. b) A biodegradable pH sensor based on doped silicon nanoribbons (Si NRs) at different stages of dissolution while submerged in PBS (pH 10) at 24 °C. Reproduced with permission.91 Copyright 2015, United States National Academy of Sciences. c) Capacitive biodegradable electrophysiological sensors and their dissolution in PBS (pH 10) at 24 °C. Reproduced with permission.91 Copyright 2015, United States National Academy of Sciences.
Figure 3 Transient electronics. a) Disintegrable electronics comprising iron as electrodes at various stages of disintegration in a pH 4.6 buffer solution (scale bars = 5 mm). Reproduced with permission.90 Copyright 2017, United States National Academy of Sciences. b) A biodegradable pH sensor based on doped silicon nanoribbons (Si NRs) at different stages of dissolution while submerged in PBS (pH 10) at 24 °C. Reproduced with permission.91 Copyright 2015, United States National Academy of Sciences. c) Capacitive biodegradable electrophysiological sensors and their dissolution in PBS (pH 10) at 24 °C. Reproduced with permission.91 Copyright 2015, United States National Academy of Sciences.CC BY · PubMed Central
Figure 4 Advances in flexible data storage and memory units. a) Photograph of a flexible 8 × 8 array‐type Ti/Au/Al/PI:PCBM/Al organic memory device. Reproduced with permission.97 Copyright 2010, Wiley‐VCH Verlag GmbH & Co. KGaA, Weinheim. b) A flexible 1D‐1R organic resistive memory cell array on a flexible PEN substrate. Scale bar = 5 mm. Reproduced with permission.98 Copyright 2013, Nature Publishing Group. c) Photograph of a 22 × 22 multiplexed charge trap floating gate memory array (top) and a magnified image (bottom) illustrating four memory pixels interconnected with word and bit lines. Reproduced with permission.99 Copyright 2016, American Association for the Advancement of Science.
Figure 4 Advances in flexible data storage and memory units. a) Photograph of a flexible 8 × 8 array‐type Ti/Au/Al/PI:PCBM/Al organic memory device. Reproduced with permission.97 Copyright 2010, Wiley‐VCH Verlag GmbH & Co. KGaA, Weinheim. b) A flexible 1D‐1R organic resistive memory cell array on a flexible PEN substrate. Scale bar = 5 mm. Reproduced with permission.98 Copyright 2013, Nature Publishing Group. c) Photograph of a 22 × 22 multiplexed charge trap floating gate memory array (top) and a magnified image (bottom) illustrating four memory pixels interconnected with word and bit lines. Reproduced with permission.99 Copyright 2016, American Association for the Advancement of Science.CC BY · PubMed Central
Figure 5 Applications of wearable devices in drug delivery. a) Stretch‐actuated drug delivery from elastomer films comprising microgel depots containing therapeutic nanoparticles for diabetes, anticancer, and antibacterial treatments. The device comprises a microneedle array (SEM image) for stretch‐mediated control of insulin delivery. Reproduced with permission.138 Copyright 2015, The American Chemical Society. b) A microfluidic reciprocating pump and electromagnetic actuators for intracochlear drug delivery. Reproduced with permission.148 Copyright 2016, The Royal Society of Chemistry. c) Latanoprost‐eluting contact lenses on the surface of a rabbit's eye for glaucoma treatment. The arrowhead illustrates the lens edge and the arrow show inner diameter of drug‐polymer film. Reproduced with permission.149 Copyright 2014, Elsevier.
Figure 5 Applications of wearable devices in drug delivery. a) Stretch‐actuated drug delivery from elastomer films comprising microgel depots containing therapeutic nanoparticles for diabetes, anticancer, and antibacterial treatments. The device comprises a microneedle array (SEM image) for stretch‐mediated control of insulin delivery. Reproduced with permission.138 Copyright 2015, The American Chemical Society. b) A microfluidic reciprocating pump and electromagnetic actuators for intracochlear drug delivery. Reproduced with permission.148 Copyright 2016, The Royal Society of Chemistry. c) Latanoprost‐eluting contact lenses on the surface of a rabbit's eye for glaucoma treatment. The arrowhead illustrates the lens edge and the arrow show inner diameter of drug‐polymer film. Reproduced with permission.149 Copyright 2014, Elsevier.CC BY · PubMed Central
Figure 6 Applications of virtual reality in medicine. a) Dichoptic training game seen through a head‐mounted optical display in virtual reality. The amblyopic eye views the left side of the image to fly the spaceship through the blue gates. Spaceship is only seen with the dominant eye (right side). Reproduced with permission.161 Copyright 2017, Springer. b) The RAPAEL Smart Glove system tracks the posture and the motion of a user's distal limb. Reproduced with permission.138, 162 Copyright 2016, BioMed Central Ltd. c) The use of head‐mounted optical displays with virtual reality in a pediatric burn patient during motion exercises. Reproduced with permission.163 Copyright 2014, Mary Ann Liebert, Inc.
Figure 6 Applications of virtual reality in medicine. a) Dichoptic training game seen through a head‐mounted optical display in virtual reality. The amblyopic eye views the left side of the image to fly the spaceship through the blue gates. Spaceship is only seen with the dominant eye (right side). Reproduced with permission.161 Copyright 2017, Springer. b) The RAPAEL Smart Glove system tracks the posture and the motion of a user's distal limb. Reproduced with permission.138, 162 Copyright 2016, BioMed Central Ltd. c) The use of head‐mounted optical displays with virtual reality in a pediatric burn patient during motion exercises. Reproduced with permission.163 Copyright 2014, Mary Ann Liebert, Inc.CC BY · PubMed Central
Figure 7 Closed‐loop wearables. a) A wearable device for glucose monitoring and drug‐delivery that can wirelessly communicates with smartphones via Bluetooth. Reproduced with permission.167 Copyright 2016, Nature Publishing Group. b) A microfluidic bandage on the arm. The wearable device consists of a capacitive touch detector, a temperature sensor, and a drug delivery pump. Reproduced with permission.168 Copyright 2014, Wiley‐VCH Verlag GmbH & Co. KGaA, Weinheim.
Figure 7 Closed‐loop wearables. a) A wearable device for glucose monitoring and drug‐delivery that can wirelessly communicates with smartphones via Bluetooth. Reproduced with permission.167 Copyright 2016, Nature Publishing Group. b) A microfluidic bandage on the arm. The wearable device consists of a capacitive touch detector, a temperature sensor, and a drug delivery pump. Reproduced with permission.168 Copyright 2014, Wiley‐VCH Verlag GmbH & Co. KGaA, Weinheim.CC BY · PubMed Central
Figure 8 Flexible batteries and wires energy transfer for wearable devices. a) Photograph of a biaxially stretched (300%) battery with serpentine interconnects. The inset shows the electrode pads and interconnects of the battery. Scale bar = 2.0 mm. Reproduced with permission.187 Copyright 2013, Nature Publishing Group. b) A flexible liquid alloy coil for wireless power transfer. Reproduced with permission.194 Copyright 2015, Nature Publishing Group.
Figure 8 Flexible batteries and wires energy transfer for wearable devices. a) Photograph of a biaxially stretched (300%) battery with serpentine interconnects. The inset shows the electrode pads and interconnects of the battery. Scale bar = 2.0 mm. Reproduced with permission.187 Copyright 2013, Nature Publishing Group. b) A flexible liquid alloy coil for wireless power transfer. Reproduced with permission.194 Copyright 2015, Nature Publishing Group.CC BY · PubMed Central
Figure 9 Flexible displays for wearable devices. a) Photograph of flexible display having a 16 × 16 array of ILEDs on a sheet of plastic (PET) wrapped around a thumb. The inset shows the display around a cylindrical glass tube (radius ≈12 mm). Reproduced with permission.194, 197 Copyright 2009, American Association for the Advancement of Science. b) An image of an array of ILEDs array (6 × 6), stretched on the sharp tip of a pencil. Reproduced with permission.198 Copyright 2010, Nature Publishing Group. c) A photograph of green QLEDs laminated on wrinkled Al foil. Reproduced with permission.199 Copyright 2015, Nature Publishing Group.
Figure 9 Flexible displays for wearable devices. a) Photograph of flexible display having a 16 × 16 array of ILEDs on a sheet of plastic (PET) wrapped around a thumb. The inset shows the display around a cylindrical glass tube (radius ≈12 mm). Reproduced with permission.194, 197 Copyright 2009, American Association for the Advancement of Science. b) An image of an array of ILEDs array (6 × 6), stretched on the sharp tip of a pencil. Reproduced with permission.198 Copyright 2010, Nature Publishing Group. c) A photograph of green QLEDs laminated on wrinkled Al foil. Reproduced with permission.199 Copyright 2015, Nature Publishing Group.CC BY · PubMed Central
Figure 10 The wearables market. a) Unit sales worldwide by region. b) Number of connected wearable devices worldwide. c) Wearables forecast by product type worldwide. d) User penetration by age group. e) Regulated wearable devices by product category in the United States in 2016. f) Sensor type market projection of wearables market by 2020. g) Annual investment and the number of deals. h) Investment deal breakdown by stage (2013–2014). i) Revenues in wearables worldwide.
Figure 10 The wearables market. a) Unit sales worldwide by region. b) Number of connected wearable devices worldwide. c) Wearables forecast by product type worldwide. d) User penetration by age group. e) Regulated wearable devices by product category in the United States in 2016. f) Sensor type market projection of wearables market by 2020. g) Annual investment and the number of deals. h) Investment deal breakdown by stage (2013–2014). i) Revenues in wearables worldwide.CC BY · PubMed Central

Verification

Claims the paper makes

13 Valid · 46 Not valid · 153 Not checked · 68 Own results and interpretations

130 more claims · 17 with their cited sources checked

Create a free account to see all 280 claims and to verify the 19 references still open.

See all claims — free account
  • Probably not a substantial claim. 97
  • It may state two separate claims as one. 81
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Items 201–258 of 258

Research works printed but not linked: 64

  1. Gaikwad G., 2017, Proc. of the 2017 Conf. on Interaction Design and Children
  2. 2014, Global Status Report on Alcohol and Health, Management of Substance Abuse Unit
  3. 2009, Bactrack Select Breathalyzer S80 Owner's Manual
  4. Kong K., 2008, Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems
  5. Gatto A., 2014, IEEE/ASME 10th Int. Conf. on Mechatronic and Embedded Systems and Applications
  6. Oks A., 2016, XIV Mediterranean Conf. on Medical and Biological Engineering and Computing 2016
  7. Perrier A., 2014, Innov. Res. BioMed. Eng., 35, 72
  8. Castano L., 2009, Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems
  9. Megraud F., 1994, Aliment Pharmacol. Ther., 9, 85
  10. Tseng C.‐K., 2012, 2012 IEEE Sensors
  11. Liao Y., 2011, Int. Solid‐State Circuits Conf
  12. Yetisen A. K., 2014, Appl. Phys. Lett., 105
  13. Yetisen A. K., 2015, Biotechnol. Adv.
  14. Jiang N., 2017, Adv. Funct. Mater., 1702715
  15. Chen F., 2009, SIGMETRICS ‘09, Proceedings of the Eleventh International Joint Conference on Measurement and Modeling of Computer Systems
  16. Pandian P., 2016, 2016 Int. Conf. on Signal Processing and Communication (ICSC)
  17. Chinaei M. H., 2017, A World of Wireless, Mobile and Multimedia Networks (WoWMoM), IEEE 18th Int. Symp
  18. Nair K., 2015, 2015 Int. Conf. on Green Computing and Internet of Things (ICGCIoT)
  19. Yoon Y., 2016, Advances in Services Computing: 10th Asia‐Pacific Services Computing Conf
  20. Faragher R., 2014, Proc.of the 27th Int. Technical Meeting of the Satellite Division of the Institute of Navigation (ION GNSS+'14)
  21. Ray P. P., 2016, 2016 Int. Conf. on Signal Processing, Communication
  22. Samuel S. S. I., 2016, 3rd MEC Int. Conf. on Big Data and Smart City (ICBDSC)
  23. Zhang H., 2017, IEEE/ACM 39th International Conference on Software Engineering
  24. Chauhan J., 2016, Int. Conf. on Pervasive Computing and Communication Workshops (PerCom Workshops)
  25. Panic G., 2010, 17th IEEE Int. Conf. on Electronics
  26. Emnett F., 2000, SNUG
  27. 2011, A Multi‐Core CPU Architecture for Low Power and High Performance
  28. Venkataramanan M., 2016, Wired UK
  29. Kim J., 2013, 35th Annual Int. Conf. of the IEEE Engineering in Medicine and Biology Society (EMBC)
  30. Revadigar G., 2016, IEEE Int. Conf. on Pervasive Computing and Communication Workshops
  31. Rohloff K., 2015, 17th Int. Conf. on E‐health Networking, Application & Services
  32. Bisgaard N., 2015, Audio Engineering Society Conf.: 58th Int. Conf. on Music Induced Hearing Disorders
  33. Yetisen A. K., 2017, Adv. Mater., 29
  34. Opdyke D., 1995, Am. J. Psychiatry, 1, 626
  35. Aman M. G., 1985, Am. J. Ment. Defic., 89, 485
  36. Washington P., 2016, Proc. of the 2016 CHI Conf. Extended Abstracts on Human Factors in Computing Systems
  37. Luprano J., 2006, Int. Workshop on Wearable and Implantable Body Sensor Networks
  38. Han H., 2007, 29th Annual Int. Conf. of the IEEE Engineering in Medicine and Biology Society (EMBS)
  39. Raya M. A. D., 2002, Engineering in Medicine and Biology: 24th Annual Conf. and the Annual Fall Meeting of the Biomedical Engineering Society
  40. Shaji S., 2016, Proc. of the Second Int. Conf. on Computer and Communication Technologies, 21
  41. Zhang F., 2009, Biomedical Circuits and Systems Conf
  42. Yoon U.‐J., 2010, Int. Conf. on Wavelet Analysis and Pattern Recognition (ICWAPR)
  43. Helleputte N., 2014, IEEE Int. Solid‐State Circuits Conf. Digest of Technical Papers
  44. Lahiri K., 2002, Proc. of the 2002 Asia and South Pacific Design Automation Conference
  45. Bodine K., 2003, Proc. of the Seventh IEEE Int. Symp. on Wearable Computers (ISWC'03)
  46. 2016, Driven by Strong Smartwatch Growth and the Emergence of Smarter Watches
  47. 2017, Worldwide Quarterly Wearable Device Tracker
  48. 2017, The Cisco Visual Networking Index (VNI) Global Mobile Data Traffic Forecast Update
  49. Worldwide Wearables Forecast by Product Type, 2017, Mobile Device Trackers
  50. 2014, The Wearable Future
  51. Poupyrev I., 2016, Proc. of the 2016 CHI Conf. on Human Factors in Computing Systems
  52. Hayward J., 2017, Wearable Technology 2017–2027: Markets
  53. 2015, Mobile Medical Applications: Guidance for Industry and Food and Drug Administration Staff
  54. 2013, Report on Smart Wearable Devices: Fitness, Healthcare
  55. Chen Z., 2014, Proc. of the 2014 ACM Int. Joint Conf. on Pervasive and Ubiquitous Computing: Adjunct Publication
  56. Arora S., 2014, Int. Conf. on Acoustics
  57. Morgan P., 2012, J. Sleep Res., 21, 217
  58. Landry G. J., 2015, Front. Aging Neurosci., 7, 165
  59. Alstad Z., 2016, CHI 2016
  60. 2015, Exploratory Study of Biotelemetry in Amyotrophic Lateral Sclerosis
  61. Jo E., 2016, Validation of the Fitbit® Surge™ and Charge HR™ Fitness Trackers
  62. Segall B., 2016, Sometimes Your Fitness Tracker Lies—A Lot
  63. Brynjarsdottir H., 2012, Proc. of the SIGCHI Conf. on Human Factors in Computing Systems
  64. Ledger D., 2014, Inside Wearables, How the Science of Human Behavior Change Offers the Secret to Long‐Term Engagement

Cited by

See all 569

Metadata

Authors
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H.
Affiliations
  • Technical University of Munich (DE)
  • TUM Incubator Technische Universität München Lichtenberg Str. 6 Garching b. München D‐85748 Germany
  • Triton Systems (United States) (US)
  • University of California, Los Angeles (US)
  • University of Birmingham (GB)
Corresponding author
Yetisen, Ali K.
Venue
Advanced Materials
Publisher
Wiley
Published
2018-06-11
Volume
30
Issue
33
Pages
e1706910-e1706910
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2808514730
Cited by
569
References
256
Citations by year
2026: 51 · 2025: 81 · 2024: 77 · 2023: 69 · 2022: 80 · 2021: 80 · 2020: 66 · 2019: 56 · 2018: 9
FWCI
21.07
Type
journal article
Language
en
Open access
Locations
  • Advanced Materials (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • University of Birmingham Research Portal (University of Birmingham) (submittedVersion, cc-by)
  • mediaTUM – the media and publications repository of the Technical University Munich (Technical University Munich) (submittedVersion, other-oa)
  • Spiral (Imperial College London) (submittedVersion, cc-by)
Funders
  • Alexander von Humboldt-Stiftung
  • Carl Friedrich von Siemens Stiftung
  • Wellcome Trust
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
wearable devices, flexible electronics, electrochemical biosensor, microfluidics, Internet of Things, physiological monitoring, vital signs, stimuli-responsive drug delivery, energy management, data security, clinical trials

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.