Cross‐Link‐Functionalized Nanoparticles for Rapid Excretion in Nanotheranostic Applications
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Most NIR‐IIb fluorophores are nanoparticle‐based probes with long retention (≈1 month or longer) in the body. Here, we applied a novel cross‐linked coating to functionalize core/shell lead sulfide/cadmium sulfide quantum dots (PbS/CdS QDs) emitting at ≈1600 nm. The coating was comprised of an amphiphilic polymer followed by three crosslinked amphiphilic polymeric layers (P 3 coating), imparting high biocompatibility and >90 % excretion of QDs within 2 weeks of intravenous administration. The P 3‐QDs were conjugated to an engineered anti‐CD8 diabody (Cys‐diabody) for in vivo molecular imaging of CD8+ cytotoxic T lymphocytes (CTLs) in response to anti‐PD‐L1 therapy. Two‐plex molecular imaging in combination with down‐conversion Er nanoparticles (ErNPs) was performed for real‐time in vivo monitoring of PD‐L1 positive tumor cells and CTLs with cellular resolution by non‐invasive NIR‐IIb light sheet microscopy. Imaging of angiogenesis in the tumor microenvironment and of lymph nodes deep in the body with a signal‐to‐background ratio of up to ≈170 was also achieved using P 3‐QDs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atezolizumab and nab-paclitaxel in advanced triple-negative breast cancer
Schmid, P., Adams, S., Rugo, H. S., Schneeweiss, A., Barrios, C. H., Iwata, H., Diéras, V., Hegg, R., Im, S.-A., Shaw Wright, G., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1809615 · Cited by 4,350
Top 10 Challenges in Cancer Immunotherapy
Hegde, P. S., & Chen, D. S. (2020) · Immunity · doi:10.1016/j.immuni.2019.12.011 · Cited by 2,238
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Self-citationNanoparticles in the clinic: an update
Anselmo, A. C., & Mitragotri, S. (2019) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10143 · Cited by 1,766
A route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287
Self-citationHu, Z., Fang, C., Li, B., Zhang, Z., Cao, C., Cai, M., Su, S., Sun, X., Shi, X., Li, C., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0494-0 · Cited by 1,126
Carr, J. A., Franke, D., Caram, J. R., Perkinson, C. F., Saif, M., Askoxylakis, V., Datta, M., Fukumura, D., Jain, R. K., Bawendi, M. G., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1718917115 · Cited by 721
Next-generation in vivo optical imaging with short-wave infrared quantum dots
Bruns, O. T., Bischof, T. S., Harris, D. K., Franke, D., Shi, Y., Riedemann, L., Bartelt, A., Jaworski, F. B., Carr, J. A., Rowlands, C. J., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0056 · Cited by 686
J -Aggregates of Cyanine Dye for NIR-II in Vivo Dynamic Vascular Imaging beyond 1500 nm
Sun, C., Li, B., Zhao, M., Wang, S., Lei, Z., Lu, L., Zhang, H., Feng, L., Dou, C., Yin, D., et al. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b10043 · Cited by 582
Zhong, Y., Ma, Z., Wang, F., Wang, X., Yang, Y., Liu, Y., Zhao, X., Li, J., Du, H., Zhang, M., et al. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0262-4 · Cited by 575
Self-citationHong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Self-citationA bright organic NIR-II nanofluorophore for three-dimensional imaging into biological tissues
Wan, H., Yue, J., Zhu, S., Uno, T., Zhang, X., Yang, Q., Yu, K., Hong, G., Wang, J., Li, L., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03505-4 · Cited by 450
Self-citationBright quantum dots emitting at ∼1,600 nm in the NIR-IIb window for deep tissue fluorescence imaging
Zhang, M., Yue, J., Cui, R., Ma, Z., Wan, H., Wang, F., Zhu, S., Zhou, Y., Kuang, Y., Zhong, Y., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1806153115 · Cited by 432
Self-citationTraumatic Brain Injury Imaging in the Second Near‐Infrared Window with a Molecular Fluorophore
Zhang, X., Wang, H., Antaris, A. L., Li, L., Diao, S., Ma, R., Nguyen, A., Hong, G., Ma, Z., Wang, J., et al. (2016) · Advanced Materials · doi:10.1002/adma.201600706 · Cited by 386
Self-citationLight-sheet microscopy in the near-infrared II window
Wang, F., Wan, H., Ma, Z., Zhong, Y., Sun, Q., Tian, Y., Qu, L., Du, H., Zhang, M., Li, L., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0398-7 · Cited by 237
Self-citationImproved functionalization of oleic acid-coated iron oxide nanoparticles for biomedical applications
Bloemen, M., Brullot, W., Luong, T. T., Geukens, N., Gils, A., & Verbiest, T. (2012) · Journal of Nanoparticle Research · doi:10.1007/s11051-012-1100-5 · Cited by 206
Cited by
In vivo NIR-II fluorescence imaging for biology and medicine
Wang, F., Zhong, Y., Bruns, O., Liang, Y., & Dai, H. (2024) · Nature Photonics · doi:10.1038/s41566-024-01391-5 · Cited by 564
“NIR-II fluorescence imaging provides accurate localization of LNs and lymphatic vessels, with better contrast and resolution than in the NIR-I window 25,94,95 .”
InfluentialSelf-citationWang, F., Ren, F., Ma, Z., Qu, L., Gourgues, R., Xu, C., Baghdasaryan, A., Li, J., Zadeh, I. E., Los, J. W. N., et al. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01130-3 · Cited by 283
Self-citationActivatable fluorescence sensors for in vivo bio-detection in the second near-infrared window
Zhao, M., Li, B., Zhang, H., & Zhang, F. (2021) · Chemical Science · doi:10.1039/d0sc04789a · Cited by 168
Deep learning for in vivo near-infrared imaging
Ma, Z., Wang, F., Wang, W., Zhong, Y., & Dai, H. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2021446118 · Cited by 135
“To confirm the validity of this neural network-based image-processing method, a balb/c mouse was injected with a nanoscale NIR-IIa probe p-FE (39) (hydrodynamic size ∼12 nm) and an NIR-IIb fluorophore P3QD (40) (hydrodynamic size ∼26 nm) at the same time, and fluorescence imaging of mouse blood vessels labeled by the…”
MethodInfluentialSelf-citationIn vivo NIR-II structured-illumination light-sheet microscopy
Wang, F., Ma, Z., Zhong, Y., Salazar, F., Xu, C., Ren, F., Qu, L., Wu, A. M., & Dai, H. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2023888118 · Cited by 85
“2 h, respectively (31, 42), over which these nanoprobes extravasated in the tumor as clearly imaged by in vivo LSM imaging in a noninvasive manner (SI Appendix, Fig.”
BackgroundSelf-citation
Metadata
- Authors
- Ma, Z., Wang, F., Zhong, Y., Salazar, F., Li, J., Zhang, M., Ren, F., Wu, A. M., & Dai, H.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2020-09-02
- Volume
- 59
- Issue
- 46
- Pages
- 20552-20560
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W3043234366
- Cited by
- 56
- References
- 16
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.