Advances in the analysis of proteins and peptides by capillary electrophoresis with matrix‐assisted laser desorption/ionization and electrospray‐mass spectrometry detection
The DOI matches its Crossref record; 179 of the 179 references it cites were found in a registry or an index.
Abstract
High throughput, outstanding certainty in peptide/protein identification, exceptional resolution, and quantitative information are essential pillars in proteome research. Capillary electrophoresis (CE) coupled to mass spectrometry (MS) has proven to meet these requirements. Soft ionization techniques, such as matrix‐assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI), have paved the way for the story of success of CE‐MS in the analysis of biomolecules and both approaches are subject of discussion in this article. Meanwhile, CE‐MS is far away from representing a homogeneous field. Therefore the review will cover a vast area including the coupling of different modes of CE (capillary zone electrophoresis, capillary isoelectric foscusing, capillary electrochromatography, micellar electrokinetic chromatography, nonaqueous capillary electrophoresis) to MS as well as on‐line preconcentration techniques (transient capillary isotachophoresis, solid‐phase extraction, membrane preconcentration) applied to compensate for restricted detection sensitivity. Special attention is given to improvements in interfacing, namely addressing nanospray and coaxial sheath liquid design. Peptide mapping, collision‐induced dissociation with subsequent tandem MS, and amendments in mass accuracy of instruments improve information validity gained from MS data. With 2‐D on‐line coupling of liquid chromatography (LC) and CE a further topic will be discussed. A special section is dedicated to recent attempts in establishing CE‐ESI‐MS in proteomics, in the clinical and diagnostic field, and in the food sector.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Keller, A., Nesvizhskii, A. I., Kolker, E., & Aebersold, R. (2002) · Analytical Chemistry · doi:10.1021/ac025747h · Cited by 4,830
Electrospray ionization mass spectrometry : fundamentals, instrumentation, and applications
Cole, R. B. (1997) · Wiley eBooks · Cited by 1,140
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Rabilloud, T. (2002) · PROTEOMICS · doi:10.1002/1615-9861(200201)2:1<3::aid-prot3>3.0.co;2-r · Cited by 717
Probing conformational changes in proteins by mass spectrometry
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00180a074 · Cited by 646
On-line mass spectrometric detection for capillary zone electrophoresis
Olivares, J. A., Nguyen, N. T., Yonker, C. R., & Smith, R. D. (1987) · Analytical Chemistry · doi:10.1021/ac00135a034 · Cited by 635
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Glycoprotein Structure Determination by Mass Spectrometry
Dell, A., & Morris, H. R. (2001) · Science · doi:10.1126/science.1058890 · Cited by 577
Tang, L., & Kebarle, P. (1993) · Analytical Chemistry · doi:10.1021/ac00072a020 · Cited by 506
Katta, V., & Chait, B. T. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00022a058 · Cited by 475
Probability-Based Validation of Protein Identifications Using a Modified SEQUEST Algorithm
MacCoss, M. J., Wu, C. C., & Yates, J. R. (2002) · Analytical Chemistry · doi:10.1021/ac025826t · Cited by 377
Mechanism of electrospray mass spectrometry. Electrospray as an electrolysis cell
Blades, A. T., Ikonomou, M. G., & Kebarle, P. (1991) · Analytical Chemistry · doi:10.1021/ac00019a009 · Cited by 364
Electrospray-ion spray: a comparison of mechanisms and performance
Ikonomou, M. G., Blades, A. T., & Kebarle, P. (1991) · Analytical Chemistry · doi:10.1021/ac00018a017 · Cited by 322
Recent advances in capillary electrophoresis/electrospray/mass spectrometry
Banks, J. F. (1997) · ELECTROPHORESIS · doi:10.1002/elps.1150181216 · Cited by 308
Capillary electrophoresis-mass spectrometry
Cai, J., & Henion, J. (1995) · Journal of Chromatography A · doi:10.1016/0021-9673(94)01178-h · Cited by 305
Capillary electrophoresis – mass spectrometry: 15 years of developments and applications
Schmitt‐Kopplin, P., & Frommberger, M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305659 · Cited by 289
The state of the art of dynamic coatings
Righetti, P. G., Gelfi, C., Verzola, B., & Castelletti, L. (2001) · ELECTROPHORESIS · doi:10.1002/1522-2683(200102)22:4<603::aid-elps603>3.0.co;2-n · Cited by 240
Dobo, A., & Kaltashov, I. A. (2001) · Analytical Chemistry · doi:10.1021/ac010713f · Cited by 237
Jensen, P. K., Paša-Tolić, L., Anderson, G. A., Horner, J. A., Lipton, M. S., Bruce, J. E., & Smith, R. D. (1999) · Analytical Chemistry · doi:10.1021/ac990196p · Cited by 231
Supercharged Protein and Peptide Ions Formed by Electrospray Ionization
Iavarone, A. T., Jurchen, J. C., & Williams, E. R. (2001) · Analytical Chemistry · doi:10.1021/ac001251t · Cited by 229
Electrospray: Its potential and limitations as an ionization method for biomolecules
Mann, M. (1990) · Organic Mass Spectrometry · doi:10.1002/oms.1210251104 · Cited by 225
The role of separation science in proteomics research
Issaq, H. J. (2001) · ELECTROPHORESIS · doi:10.1002/1522-2683(200109)22:17<3629::aid-elps3629>3.0.co;2-o · Cited by 219
Attomole-Sensitivity Electrospray Source for Large-Molecule Mass Spectrometry
Valaskovic, G. A., Kelleher, N. L., Little, D. P., Aaserud, D. J., & McLafferty, F. W. (1995) · Analytical Chemistry · doi:10.1021/ac00116a030 · Cited by 217
Lee, E. D., Mück, W., Henion, J. D., & Covey, T. R. (1988) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)90575-2 · Cited by 209
Noncovalent Polycationic Coatings for Capillaries in Capillary Electrophoresis of Proteins
Córdova, E., Gao, J., & Whitesides, G. M. (1997) · Analytical Chemistry · doi:10.1021/ac960432l · Cited by 207
Wang, C., Oleschuk, R., Ouchen, F., Li, J., Thibault, P., & Harrison, D. J. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/1097-0231(20000815)14:15<1377::aid-rcm31>3.0.co;2-2 · Cited by 204
Neuhoff, N. V., Kaiser, T., Wittke, S., Krebs, R., Pitt, A., Burchard, A., Sundmacher, A., Schlegelberger, B., Kolch, W., & Mischak, H. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1294 · Cited by 200
Characterization of an Electrospray Ion Source as a Controlled-Current Electrolytic Cell
Van Berkel, G. J., & Zhou, F. (1995) · Analytical Chemistry · doi:10.1021/ac00113a028 · Cited by 197
Recent advances in capillary electrophoresis/electrospray-mass spectrometry
von Brocke, A., Nicholson, G., & Bayer, E. (2001) · ELECTROPHORESIS · doi:10.1002/1522-2683(200105)22:7<1251::aid-elps1251>3.0.co;2-9 · Cited by 197
Wittke, S., Fliser, D., Haubitz, M., Bartel, S., Krebs, R., Hausadel, F., Hillmann, M., Golovko, I., Koester, P., Haller, H., et al. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00713-1 · Cited by 191
Cohen, S. L., & Chait, B. T. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2072 · Cited by 190
On‐line capillary electrophoresis‐mass spectrometry for the analysis of biomolecules
Hernández‐Borges, J., Neusüß, C., Cifuentes, A., & Pelzing, M. (2004) · ELECTROPHORESIS · doi:10.1002/elps.200405954 · Cited by 182
Proteomics based on high-efficiency capillary separations
Shen, Y., & Smith, R. D. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200209)23:18<3106::aid-elps3106>3.0.co;2-y · Cited by 172
Thompson, T. J., Foret, F., Vouros, P., & Karger, B. L. (1993) · Analytical Chemistry · doi:10.1021/ac00055a012 · Cited by 167
Iki, N., & Yeung, E. S. (1996) · Journal of Chromatography A · doi:10.1016/0021-9673(95)01158-7 · Cited by 165
Desolvation of ions and molecules in thermospray mass spectrometry
Schmelzeisen-Redeker, G., Bütfering, L., & Röllgen, F. W. (1989) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(89)85004-9 · Cited by 163
Foret, F., Thompson, T. J., Vouros, P., Karger, B. L., Gebauer, P., & Bocek, P. (1994) · Analytical Chemistry · doi:10.1021/ac00096a010 · Cited by 161
Moini, M. (2002) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-002-1283-1 · Cited by 151
Sample stacking revisited: A personal perspective
Chien, R. (2003) · Electrophoresis · doi:10.1002/elps.200390057 · Cited by 146
Grandori, R. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.390 · Cited by 146
Transient pseudo-isotachophoresis for sample concentration in capillary electrophoresis
Shihabi, Z. K. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200206)23:11<1612::aid-elps1612>3.0.co;2-3 · Cited by 144
Tong, W., Link, A., Eng, J. K., & Yates, J. R. (1999) · Analytical Chemistry · doi:10.1021/ac9901182 · Cited by 143
Proteome analysis using selective incorporation of isotopically labeled amino acids
Veenstra, T. D., Martinović, S., Anderson, G. A., Paša-Tolić, L., & Smith, R. D. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00120-8 · Cited by 142
Hofstadler, S. A., Severs, J. C., Smith, R. D., Swanek, F. D., & Ewing, A. G. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19960610)10:8<919::aid-rcm597>3.0.co;2-8 · Cited by 137
Hofstadler, S. A., Swanek, F. D., Gale, D. C., Ewing, A. G., & Smith, R. D. (1995) · Analytical Chemistry · doi:10.1021/ac00104a028 · Cited by 130
Moseley, M. A., Jorgenson, J. W., Shabanowitz, J., Hunt, D. F., & Tomer, K. B. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)87056-5 · Cited by 130
Online Time-of-Flight Mass Spectrometric Analysis of Peptides Separated by Capillary Electrophoresis
Fang, L., Zhang, R., Williams, E. R., & Zare, R. N. (1994) · Analytical Chemistry · doi:10.1021/ac00093a025 · Cited by 129
Capillary electrophoresis‐mass spectrometry for glycoscreening in biomedical research
Zamfir, A., & Peter‐Katalinić, J. (2004) · ELECTROPHORESIS · doi:10.1002/elps.200405825 · Cited by 125
Jensen, P. K., Paìa-Tolić, L., Peden, K. K., Martinović, S., Lipton, M. S., Anderson, G. A., Tolić, N., Wong, K.-K., & Smith, R. D. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:7<1372::aid-elps1372>3.0.co;2-y · Cited by 124
Disposable Emitters for On-line Capillary Zone Electrophoresis/Nanoelectrospray Mass Spectrometry
Bateman, K. P., White, R. L., & Thibault, P. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19970215)11:3<307::aid-rcm850>3.0.co;2-m · Cited by 123
Guzman, N. A., & Stubbs, R. J. (2001) · Electrophoresis · doi:10.1002/1522-2683(200109)22:17<3602::aid-elps3602>3.0.co;2-x · Cited by 122
Kelly, J. F., Locke, S. J., Ramaley, L., & Thibault, P. (1996) · Journal of Chromatography A · doi:10.1016/0021-9673(94)01197-4 · Cited by 115
Cao, P., & Moini, M. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00015-9 · Cited by 114
Cao, P., & Stults, J. T. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00481-1 · Cited by 112
Berkel, G. J. V., & Zhou, F. (1995) · Analytical Chemistry · doi:10.1021/ac00117a022 · Cited by 112
Peer Reviewed: Advances in CE/MS.
Ding, J., & Vouros, P. (1999) · Analytical Chemistry · doi:10.1021/ac9904415 · Cited by 111
Nilsson, S., Wetterhall, M., Bergquist, J., Nyholm, L., & Markides, K. E. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.466 · Cited by 110
Cao, P., & Stults, J. T. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/1097-0231(20000915)14:17<1600::aid-rcm68>3.0.co;2-v · Cited by 110
Figeys, D., Ducret, A., & Aebersold, R. H. (1997) · Journal of Chromatography A · doi:10.1016/s0021-9673(96)00847-3 · Cited by 108
Capillary isoelectric focusing-electrospray mass spectrometry for protein analysis
Tang, Q., Harrata, A. K., & Lee, C. S. (1995) · Analytical Chemistry · doi:10.1021/ac00115a021 · Cited by 103
Corradini, D. (1997) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(97)00301-0 · Cited by 102
Capillary Array Electrophoresis-MALDI Mass Spectrometry Using a Vacuum Deposition Interface
Preisler, J., Hu, P., Rejtar, T., Moskovets, E. V., & Karger, B. L. (2001) · Analytical Chemistry · doi:10.1021/ac010692p · Cited by 101
Ullsten, S., Zuberovic, A., Wetterhall, M., Hardenborg, E., Markides, K. E., & Bergquist, J. (2004) · Electrophoresis · doi:10.1002/elps.200305787 · Cited by 100
Polyaniline: A conductive polymer coating for durable nanospray emitters
Maziarz, E. P., Lorenz, S. A., White, T. P., & Wood, T. D. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00134-3 · Cited by 97
Kaiser, T., Hermann, A., Kielstein, J. T., Wittke, S., Bartel, S. J., Krebs, R., Hausadel, F., Hillmann, M., Golovko, I., Koester, P., et al. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00712-x · Cited by 97
Comprehensive on-line RPLC-CZE-MS of peptides
Lewis, K. C., Opiteck, G. J., Jorgenson, J. W., & Sheeley, D. M. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00009-3 · Cited by 95
Capillary electrophoresis-electrospray ionization-mass spectrometry
Edmonds, C. G., Loo, J. A., Barinaga, C. J., Udseth, H. R., & Smith, R. D. (1989) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)93899-3 · Cited by 94
Simó, C., Elvira, C., González, N., Román, J. S., Barbas, C., & Cifuentes, A. (2004) · Electrophoresis · doi:10.1002/elps.200305790 · Cited by 93
Hardenborg, E., Zuberovic, A., Ullsten, S., Söderberg, L., Heldin, E., & Markides, K. E. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00739-8 · Cited by 93
Kaiser, T., Wittke, S., Just, I., Krebs, R., Bartel, S. J., Fliser, D., Mischak, H., & Weissinger, E. M. (2004) · Electrophoresis · doi:10.1002/elps.200305788 · Cited by 92
Guzman, N. A. (2000) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)00410-2 · Cited by 91
Capillary electrophoresis of proteins 2001–2003
Hutterer, K. M., & Dolník, V. (2003) · Electrophoresis · doi:10.1002/elps.200305635 · Cited by 88
Moini, M. (2001) · Analytical Chemistry · doi:10.1021/ac010189c · Cited by 86
Ivanov, A. R., Horváth, C., & Karger, B. L. (2003) · Electrophoresis · doi:10.1002/elps.200305620 · Cited by 85
Li, M. X., Liu, L., Wu, J.-T., & Lubman, D. M. (1997) · Analytical Chemistry · doi:10.1021/ac970076m · Cited by 84
Chang, Y. Z., & Her, G. R. (2000) · Analytical Chemistry · doi:10.1021/ac990535e · Cited by 83
Banks, J. F., & Dresch, T. (1996) · Analytical Chemistry · doi:10.1021/ac9509824 · Cited by 83
Long-lived metallized tips for nanoliter electrospray mass spectrometry
Valaskovic, G. A., & McLafferty, F. W. (1996) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00152-3 · Cited by 82
Surfactants Usable for Electrospray Ionization Mass Spectrometry
Ishihama, Y., Katayama, H., & Asakawa, N. (2000) · Analytical Biochemistry · doi:10.1006/abio.2000.4836 · Cited by 82
A Sheathless Nanoflow Electrospray Interface for On-Line Capillary Electrophoresis Mass Spectrometry
Janini, G. M., Conrads, T. P., Wilkens, K. L., Issaq, H. J., & Veenstra, T. D. (2003) · Analytical Chemistry · doi:10.1021/ac020661+ · Cited by 80
García, M. C., Hogenboom, A. C., Zappey, H. W., & Irth, H. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00345-x · Cited by 80
Effects of nebulizing and drying gas flow on capillary electrophoresis/mass spectrometry
Huikko, K., Kotiaho, T., & Kostiainen, R. K. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.744 · Cited by 80
Na, D. H., Youn, Y. S., Lee, S. D., Son, M., Kim, W. B., DeLuca, P. P., & Lee, K. C. (2003) · Journal of Controlled Release · doi:10.1016/s0168-3659(03)00366-3 · Cited by 80
Mass Spectrometry of Proteins and Peptides
Chapman, J. R. (2000) · Humana Press eBooks · doi:10.1385/1592590454 · Cited by 79
State‐of‐the‐art of the hyphenation of capillary electrochromatography with mass spectrometry
Barceló‐Barrachina, E., Moyano, E., & Galcerán, M. T. (2004) · Electrophoresis · doi:10.1002/elps.200305908 · Cited by 79
Interpreting conformational effects in protein nano-ESI-MS spectra
Šamalíková, M., Matečko‐Burmann, I., Müller, N., & Grandori, R. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2339-6 · Cited by 78
Smith, R. D. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00352-3 · Cited by 78
Characterization of proteinases from Antarctic krill (Euphausia superba)
Sjödahl, J., Emmer, Å., Vincent, J., & Roeraade, J. (2002) · Protein Expression and Purification · doi:10.1016/s1046-5928(02)00519-3 · Cited by 75
Capillary Electrophoresis to Mass Spectrometry Interface Using a Porous Junction
Whitt, J. T., & Moini, M. (2003) · Analytical Chemistry · doi:10.1021/ac026380j · Cited by 74
Wachs, T., Sheppard, R. L., & Henion, J. (1996) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(96)00176-4 · Cited by 73
A CE−MALDI Interface Based on the Use of Prestructured Sample Supports
Johnson, T., Bergquist, J., Ekman, R., Nordhoff, E., Schürenberg, M., Klöppel, K.-D., Müller, M., Lehrach, H., & Gobom, J. (2001) · Analytical Chemistry · doi:10.1021/ac0011888 · Cited by 73
Mass Spectrometry of Intracellular and Membrane Proteins Using Cleavable Detergents
Norris, J. L., Porter, N. A., & Caprioli, R. M. (2003) · Analytical Chemistry · doi:10.1021/ac034802z · Cited by 73
Clarke, N. J., Tomlinson, A. J., Schomburg, G., & Naylor, S. (1997) · Analytical Chemistry · doi:10.1021/ac961283+ · Cited by 73
Foret, F., Müller, O., Thorne, J. M., Goetzinger, W. K., & Karger, B. L. (1995) · Journal of Chromatography A · doi:10.1016/0021-9673(95)00621-s · Cited by 73
Subatmospheric electrospray interface for coupling of microcolumn separations with mass spectrometry
Foret, F., Zhou, H., Gangl, E., & Karger, B. L. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:7<1363::aid-elps1363>3.0.co;2-u · Cited by 71
Yang, C. L., Liu, H., Yang, Q. L., Zhang, L., Zhang, W., & Zhang, Y. (2002) · Analytical Chemistry · doi:10.1021/ac026187p · Cited by 71
Varghese, J., & Cole, R. B. (1993) · Journal of Chromatography A · doi:10.1016/0021-9673(93)83255-q · Cited by 71
Sanz‐Nebot, V., Benavente, F., Vallverdú, A., Guzman, N. A., & Barbosa, J. (2003) · Analytical Chemistry · doi:10.1021/ac030171x · Cited by 71
Larsson, M., & Lutz, M. (2000) · Electrophoresis · doi:10.1002/1522-2683(20000801)21:14<2859::aid-elps2859>3.0.co;2-f · Cited by 70
Martinović, S., Berger, S. J., Paša-Tolić, L., & Smith, R. D. (2000) · Analytical Chemistry · doi:10.1021/ac0004557 · Cited by 70
Cao, P., & Moini, M. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00081-6 · Cited by 70
Single-Neuron Analysis Using CE Combined with MALDI MS and Radionuclide Detection
Page, J. S., Rubakhin, S. S., & Sweedler, J. V. (2002) · Analytical Chemistry · doi:10.1021/ac0156621 · Cited by 70
Huber, C. G., Premstaller, A., & Kleindienst, G. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00533-6 · Cited by 69
Figeys, D., Corthals, G. L., Gallis, B., Goodlett, D. R., Ducret, A., Corson, M. A., & Aebersold, R. (1999) · Analytical Chemistry · doi:10.1021/ac9813991 · Cited by 67
Rohde, E., Tomlinson, A. J., Johnson, D. H., & Naylor, S. (1998) · Electrophoresis · doi:10.1002/elps.1150191317 · Cited by 67
Rubakhin, S. S., Page, J. S., Monroe, B. R., & Sweedler, J. V. (2001) · Electrophoresis · doi:10.1002/1522-2683(200109)22:17<3752::aid-elps3752>3.0.co;2-h · Cited by 65
MCCOURT, J., Bordin, G., & ROSARODRIGUEZ, A. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00050-5 · Cited by 65
Wu, J.-T., Huang, P., Li, M. X., Qian, M. G., & Lubman, D. M. (1997) · Analytical Chemistry · doi:10.1021/ac9609900 · Cited by 63
Smith, A. D., & Moini, M. (2000) · Analytical Chemistry · doi:10.1021/ac0007940 · Cited by 63
Demelbauer, U. M., Plematl, A., Kremser, L., Allmaier, G., Josic, D., & Rizzi, A. (2004) · ELECTROPHORESIS · doi:10.1002/elps.200305936 · Cited by 62
Mazereeuw, M., Hofte, A. J. P., Tjaden, U. R., & van der Greef, J. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19970615)11:9<981::aid-rcm901>3.0.co;2-s · Cited by 61
Li, Y., & Cole, R. B. (2003) · Analytical Chemistry · doi:10.1021/ac0301402 · Cited by 60
Zhou, F., & Johnston, M. V. (2004) · Analytical Chemistry · doi:10.1021/ac035446n · Cited by 59
Wetterhall, M., Nilsson, S., Markides, K. E., & Bergquist, J. (2001) · Analytical Chemistry · doi:10.1021/ac010748f · Cited by 57
Matrix-assisted laser desorption/ionisation–mass spectrometry applied to biological macromolecules
Gross, J., & Strupat, K. (1998) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00060-0 · Cited by 55
The Effect of Small Cations on the Positive Electrospray Responses of Proteins at Low pH
Pan, P., & McLuckey, S. A. (2003) · Analytical Chemistry · doi:10.1021/ac034344u · Cited by 54
Frommberger, M., Schmitt‐Kopplin, P., Menzinger, F., Albrecht, V. S., Schmid, M., Eberl, L., Hartmann, A., & Kettrup, A. (2003) · Electrophoresis · doi:10.1002/elps.200305567 · Cited by 54
Yang, L., Tang, Q. M., Harrata, A. K., & Lee, C. S. (1996) · Analytical Biochemistry · doi:10.1006/abio.1996.0492 · Cited by 54
Chang, Y., Chen, Y., & Her, G. R. (2001) · Analytical Chemistry · doi:10.1021/ac010429o · Cited by 53
Yeung, B., Porter, T. J., & Vath, J. E. (1997) · Analytical Chemistry · doi:10.1021/ac9611172 · Cited by 53
Moini, M., Demars, S. M., & Huang, H. (2002) · Analytical Chemistry · doi:10.1021/ac020022z · Cited by 52
Peterson, Z. D., Bowerbank, C. R., Collins, D. C., Graves, S. W., & Lee, M. L. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00235-8 · Cited by 51
Zhu, X., Thiam, S., Valle, B. C., & Warner, I. M. (2002) · Analytical Chemistry · doi:10.1021/ac025877q · Cited by 50
Three‐dimensional deconvolution of multiply charged spectra
Labowsky, M. J., Whitehouse, C., & Fenn, J. B. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290070117 · Cited by 50
A novel nanospray capillary zone electrophoresis/mass spectrometry interface
Hsieh, F., Baronas, E., Muir, C., & Martin, S. A. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990115)13:1<67::aid-rcm453>3.0.co;2-f · Cited by 50
McComb, M. E., Krutchinsky, A. N., Ens, W., Standing, K. G., & Perreault, H. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)01158-8 · Cited by 50
Waterval, J. C. M., Hommels, G., Teeuwsen, J., Bult, A., Lingeman, H., & UNDERBERG, W. J. M. (2000) · Electrophoresis · doi:10.1002/1522-2683(20000801)21:14<2851::aid-elps2851>3.0.co;2-q · Cited by 49
Moini, M., & Huang, H. (2004) · ELECTROPHORESIS · doi:10.1002/elps.200305906 · Cited by 47
Simó, C., & Cifuentes, A. (2003) · Electrophoresis · doi:10.1002/elps.200390105 · Cited by 46
Effect of electric field on liquid chromatographic separation of peptide digests
Apffel, A., Yin, H., Hancock, W. S., et al. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)00957-1 · Cited by 45
Stutz, H., Bordin, G., & Rodríguez, A. R. (2004) · Electrophoresis · doi:10.1002/elps.200305806 · Cited by 45
Self-citationStrategy for isolating and sequencing biologically derived MHC class I peptides
Tomlinson, A. J., Jameson, S. C., & Naylor, S. (1996) · Journal of Chromatography A · doi:10.1016/0021-9673(96)00333-0 · Cited by 45
Separation of selected metal-binding proteins with capillary zone electrophoresis
Stutz, H., Bordin, G., & Rodríguez, A. R. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(02)01403-4 · Cited by 44
Self-citationPerkins, J. R., & Tomer, K. B. (1994) · Analytical Chemistry · doi:10.1021/ac00090a008 · Cited by 43
Wei, J. Q., Yang, L., Harrata, A. K., & Lee, C. S. (1998) · Electrophoresis · doi:10.1002/elps.1150191316 · Cited by 42
Eriksson, J. H. C., Mol, R., Somsen, G. W., Hinrichs, W. L. J., Frijlink, H. W., & de Jong, G. J. (2004) · Electrophoresis · doi:10.1002/elps.200305695 · Cited by 42
Guo, X., Chan, H. M., Guevremont, R., & Siu, K. W. M. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990330)13:6<500::aid-rcm515>3.0.co;2-g · Cited by 42
Lai, C., & Her, G. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/1097-0231(20001115)14:21<2012::aid-rcm126>3.0.co;2-8 · Cited by 42
Yeung, K. K. ‐., Kiceniuk, A. G., & Li, L. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)01200-6 · Cited by 41
Nilsson, S. L., Bylund, D., Jörntén‐Karlsson, M., Petersson, P., & Markides, K. E. (2004) · Electrophoresis · doi:10.1002/elps.200305937 · Cited by 40
Clarke, N. J., Tomlinson, A. J., & Naylor, S. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00084-6 · Cited by 40
Clarke, N. J., & Naylor, S. (2002) · Biomedical Chromatography · doi:10.1002/bmc.159 · Cited by 40
Bergström, S. K., Samskog, J., & Markides, K. E. (2003) · Analytical Chemistry · doi:10.1021/ac030117g · Cited by 39
Cao, P., & Moini, M. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00146-9 · Cited by 38
Waterval, J. C. M., Hommels, G., Bestebreurtje, P., Versluis, C., Heck, A. J. R., Bult, A., Lingeman, H., & UNDERBERG, W. J. M. (2001) · Electrophoresis · doi:10.1002/1522-2683(200108)22:13<2709::aid-elps2709>3.0.co;2-t · Cited by 37
Design of a Time-of-Flight Mass Spectrometer as a Detector for Capillary Electrophoresis
Lazar, I. M., Xin, B., Lee, M. L., Lee, E. D., Rockwood, A. L., Fabbi, J. C., & Lee, H. G. (1997) · Analytical Chemistry · doi:10.1021/ac9700282 · Cited by 36
Meagher, R. J., Seong, J., Laibinis, P. E., & Barron, A. E. (2004) · Electrophoresis · doi:10.1002/elps.200305714 · Cited by 36
Lazar, I. M., Lee, E. D., Rockwood, A. L., & Lee, M. L. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)00743-2 · Cited by 36
Janini, G. M., Chan, K. C., Conrads, T. P., Issaq, H. J., & Veenstra, T. D. (2004) · Electrophoresis · doi:10.1002/elps.200405948 · Cited by 35
Simulation and optimization of peptide separation by capillary electrophoresis-mass spectrometry
Simó, C., Soto-Yarritu, P. L., & Cifuentes, A. (2002) · Electrophoresis · doi:10.1002/1522-2683(200207)23:14<2288::aid-elps2288>3.0.co;2-8 · Cited by 34
ek, M. G., Gaspari, M., Walhagen, K., Vreeken, R. J., Verheij, E. R., & van der Greef, J. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/1097-0231(20000830)14:16<1448::aid-rcm44>3.0.co;2-9 · Cited by 34
Brenner‐Weiß, G., Kirschhöfer, F., Kühl, B., Nusser, M., & Obst, U. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00553-3 · Cited by 33
A simple method for fabrication of silver‐coated sheathless electrospray emitters
Chen, Y., & Her, G. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.940 · Cited by 33
Martinović, S., Paša‐Tolić, L., Masselon, C., Jensen, P. K., Stone, C. L., & Smith, R. D. (2000) · Electrophoresis · doi:10.1002/1522-2683(20000701)21:12<2368::aid-elps2368>3.0.co;2-f · Cited by 33
Chakel, J. A., Pungor, E., Hancock, W. S., & Swedberg, S. A. (1997) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(96)00373-8 · Cited by 33
Tetler, L. W., Cooper, P. A., & Powell, B. B. (1995) · Journal of Chromatography A · doi:10.1016/0021-9673(94)01171-a · Cited by 32
Page, J. S., Rubakhin, S. S., & Sweedler, J. V. (2000) · The Analyst · doi:10.1039/a909738d · Cited by 31
Jørgensen, C. S., Jagd, M., Sørensen, B. K., McGuire, J., Barkholt, V., Højrup, P., & Houen, G. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.03.012 · Cited by 30
McComb, M. E., & Perreault, H. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:7<1354::aid-elps1354>3.0.co;2-q · Cited by 30
Fridriksson, E. K., Baird, B. A., & McLafferty, F. W. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00012-4 · Cited by 29
Jensen, P. K., Harrata, A. K., & Lee, C. S. (1998) · Analytical Chemistry · doi:10.1021/ac9712963 · Cited by 29
Knudsen, C., Bjørnsdottir, I., Jøns, O., & Hansen, S. H. (1998) · Analytical Biochemistry · doi:10.1006/abio.1998.2874 · Cited by 29
Strategies for analysis of electrophoretically separated proteins and peptides
Michalski, W. P., & Shiell, B. J. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00486-3 · Cited by 28
Deterding, L. J., Cutalo, J. M., Khaledi, M. G., & Tomer, K. B. (2002) · Electrophoresis · doi:10.1002/1522-2683(200207)23:14<2296::aid-elps2296>3.0.co;2-i · Cited by 27
Leinweber, F. C., Stein, J., & Otto, M. (2001) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160000682 · Cited by 25
Cole, R. B., Varghese, J., McCormick, R. M., & Kadlecek, D. (1994) · Journal of Chromatography A · doi:10.1016/0021-9673(94)85132-8 · Cited by 24
Jensen, C., Haebel, S., Andersen, S. O., & Roepstorff, P. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(96)04499-0 · Cited by 22
Liang, Z., Yang, Q. L., Zhang, W., Zhang, L., & Zhang, Y. (2003) · Chromatographia · doi:10.1007/bf02491738 · Cited by 22
Nilsson, S., Klett, O., Svedberg, M., Amirkhani, A., & Nyholm, L. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1082 · Cited by 21
Gaspari, M., Guček, M., Walhagen, K., Vreeken, R. J., Verheij, E. R., Tjaden, U. R., & van der Greef, J. (2001) · Journal of Microcolumn Separations · doi:10.1002/mcs.1049 · Cited by 21
Bihoreau, N., Ramon, C., Lazard, M., & Schmitter, J. (1997) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(97)00305-8 · Cited by 20
Waterval, J. C. M., Krabbe, H. G., Teeuwsen, J., Bult, A., Lingeman, H., & UNDERBERG, W. J. M. (1999) · Electrophoresis · Cited by 20
He, T., Chandramouli, N., Fu, E. W., Wu, A. D., & Wang, Y. K. (1999) · Analytical Biochemistry · doi:10.1006/abio.1999.4133 · Cited by 17
Tang, Q. M., Harrata, A. K., & Lee, C. S. (1996) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199611)31:11<1284::aid-jms422>3.0.co;2-3 · Cited by 17
Shen, J., & BUKO, A. M. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00381-0 · Cited by 14
Young, S. Y., Ye, S. H., Moo, J. S., & Park, J. (1997) · Journal of Chromatography A · doi:10.1016/s0021-9673(96)00929-6 · Cited by 12
Katayama, H., Ishihama, Y., Oda, Y., & Asakawa, N. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/1097-0231(20000730)14:14<1167::aid-rcm5>3.0.co;2-r · Cited by 10
Liu, T., Shao, X., Zeng, R., & Xia, Q. (2002) · PubMed · Cited by 5
Davidson, H. E., Doherty, A., Stevenson, B., Boyd, A. C., & Porteous, D. J. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19990601)20:7<1527::aid-elps1527>3.0.co;2-9 · Cited by 1
Cited by
Mischak, H., Coon, J. J., Novak, J., Weissinger, E. M., Schanstra, J. P., & Dominiczak, A. F. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20205 · Cited by 193
“An excellent and comprehensive overview on the different methods of coupling (both ESI and MALDI) is given in a recent review (Stutz, 2005).”
MethodZürbig, P., Renfrow, M. B., Schiffer, E., Novak, J., Walden, M., Wittke, S., Just, I., Pelzing, M., Neusüß, C., Theodorescu, D., et al. (2006) · ELECTROPHORESIS · doi:10.1002/elps.200500827 · Cited by 193
Capillary electrophoresis–mass spectrometry for the analysis of intact proteins
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.048 · Cited by 185
Recent advances in the application of capillary electromigration methods for food analysis
Cifuentes, A. (2006) · ELECTROPHORESIS · doi:10.1002/elps.200500474 · Cited by 185
Advances in the Analysis of Protein Phosphorylation
Paradela, A., & Albar, J. P. (2008) · Journal of Proteome Research · doi:10.1021/pr7006544 · Cited by 164
Metadata
- Authors
- Stutz, H.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2005-04
- Volume
- 26
- Issue
- 7-8
- Pages
- 1254-1290
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2073317144
- Cited by
- 168
- References
- 179
- FWCI
- 12.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.