The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Probabilistic fiber tracking using the residual bootstrap with constrained spherical deconvolution
Open accessAbstract
Constrained spherical deconvolution (CSD) is a new technique that, based on high‐angular resolution diffusion imaging (HARDI) MR data, estimates the orientation of multiple intravoxel fiber populations within regions of complex white matter architecture, thereby overcoming the limitations of the widely used diffusion tensor imaging (DTI) technique. One of its main applications is fiber tractography. The noisy nature of diffusion‐weighted (DW) images, however, affects the estimated orientations and the resulting fiber trajectories will be subject to uncertainty. The impact of noise can be large, especially for HARDI measurements, which employ relatively high b‐values. To quantify the effects of noise on fiber trajectories, probabilistic tractography was introduced, which considers multiple possible pathways emanating from one seed point, taking into account the uncertainty of local fiber orientations. In this work, a probabilistic tractography algorithm is presented based on CSD and the residual bootstrap. CSD, which provides accurate and precise estimates of multiple fiber orientations, is used to extract the local fiber orientations. The residual bootstrap is used to estimate fiber tract probability within a clinical time frame, without prior assumptions about the form of uncertainty in the data. By means of Monte Carlo simulations, the performance of the CSD fiber pathway uncertainty estimator is measured in terms of accuracy and precision. In addition, the performance of the proposed method is compared to state‐of‐the‐art DTI residual bootstrap tractography and to an existing probabilistic CSD tractography algorithm using clinical DW data. Hum Brain Mapp, 2011. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bootstrap methods: another look at the jackknife
Efron, B. (1979) · The Annals of Statistics · doi:10.1214/aos/1176344552 · Cited by 17,602
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
Bootstrap Methods and Their Application
Loughin, T. M., Davison, A. C., & Hinkley, D. V. (1999) · Journal of the American Statistical Association · doi:10.2307/2669707 · Cited by 5,418
Estimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Probabilistic diffusion tractography with multiple fibre orientations: What can we gain?
Behrens, T. E. J., Berg, H. J., Jbabdi, S., Rushworth, M. F. S., & Woolrich, M. W. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.018 · Cited by 3,471
Characterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
Tournier, J.-D., Calamante, F., & Connelly, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.016 · Cited by 2,188
Self-citationFiber tracking: principles and strategies – a technical review
Mori, S., & van Zijl, P. C. M. (2002) · NMR in Biomedicine · doi:10.1002/nbm.781 · Cited by 2,024
Tuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
A diffusion tensor imaging tractography atlas for virtual in vivo dissections.
CATANI, M., & THIEBAUTDESCHOTTEN, M. (2008) · Cortex · doi:10.1016/j.cortex.2008.05.004 · Cited by 1,642
Tournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635
Self-citationHigh angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548 · cited 4×
“However, in voxels containing multiple fiber orientations, this model has been shown to be inadequate [Alexander et al., 2002; Frank, 2001, 2002; Tuch et al., 2002].”
MethodInfluentialOptimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Self-citationThe B‐matrix must be rotated when correcting for subject motion in DTI data
Leemans, A., & Jones, D. K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21890 · Cited by 1,281
Self-citationDietrich, O., Raya, J. G., Reeder, S. B., Reiser, M. F., & Schoenberg, S. O. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20969 · Cited by 992
Water diffusion changes in wallerian degeneration and their dependence on white matter architecture
Pierpaoli, C., Barnett, A., Pajevic, S., Chen, R., Penix, L., Virta, A., & Basser, P. (2001) · NeuroImage · doi:10.1006/nimg.2001.0765 · Cited by 938
ExploreDTI: a graphical toolbox for processing, analyzing, and visualizing diffusion MR data
Leemans, A., Jeurissen, B., Sijbers, J., & Jones, D. K. (2009) · Cited by 874
Self-citationRegularized, fast, and robust analytical Q-ball imaging
Descoteaux, M., Angelino, E., Fitzgibbons, S., & Deriche, R. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21277 · Cited by 850
Deterministic and probabilistic tractography based on complex fibre orientation distributions
Descoteaux, M., Deriche, R., Knosche, T. R., & Anwander, A. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2004424 · Cited by 698
Tournier, J.-D., Yeh, C.-H., Calamante, F., Cho, K.-H., Connelly, A., & Lin, C.-P. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.05.002 · Cited by 593
Self-citationBootstrap Methods and Their Application
Buckland, S. T., Davison, A. C., & Hinkley, D. V. (1998) · Biometrics · doi:10.2307/3109789 · Cited by 575
Detection and modeling of non‐Gaussian apparent diffusion coefficient profiles in human brain data
Alexander, D. C., Barker, G. J., & Arridge, S. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10209 · Cited by 528
Parker, G. J. M., Haroon, H. A., & Wheeler‐Kingshott, C. A. M. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10350 · Cited by 527
Characterization of anisotropy in high angular resolution diffusion‐weighted MRI
Frank, L. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10156 · Cited by 510
Measurement of fiber orientation distributions using high angular resolution diffusion imaging
Anderson, A. W. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20667 · Cited by 463
Ciccarelli, O., Catani, M., Johansen-Berg, H., Clark, C., & Thompson, A. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70163-7 · Cited by 412
Anisotropy in high angular resolution diffusion-weighted MRI
Frank, L. R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1125 · Cited by 389
Resolution of complex tissue microarchitecture using the diffusion orientation transform (DOT)
Özarslan, E., Shepherd, T. M., Vemuri, B. C., Blackband, S. J., & Mareci, T. H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.024 · Cited by 388
Persistent angular structure: new insights from diffusion magnetic resonance imaging data
Jansons, K. M., & Alexander, D. C. (2003) · Inverse Problems · doi:10.1088/0266-5611/19/5/303 · Cited by 304
Just pretty pictures? What diffusion tractography can add in clinical neuroscience
Johansen-Berg, H., & Behrens, T. E. (2006) · Current Opinion in Neurology · doi:10.1097/01.wco.0000236618.82086.01 · Cited by 239
Bootstrap Methods and Their Application
Kushary, D. (2000) · Technometrics · doi:10.1080/00401706.2000.10486018 · Cited by 225
Bootstrap white matter tractography (BOOT-TRAC)
Lazar, M., & Alexander, A. L. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.08.050 · Cited by 208
A Model-Based Deconvolution Approach to Solve Fiber Crossing in Diffusion-Weighted MR Imaging
Dell'Acqua, F., Rizzo, G., Scifo, P., Clarke, R. A., Scotti, G., & Fazio, F. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.888830 · Cited by 194
Campbell, J. S. W., Siddiqi, K., Rymar, V. V., Sadikot, A. F., & Pike, G. B. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.05.014 · Cited by 177
An error analysis of white matter tractography methods: synthetic diffusion tensor field simulations
Lazar, M., & Alexander, A. L. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00277-5 · Cited by 169
Probabilistic streamline q-ball tractography using the residual bootstrap
Berman, J. I., Chung, S., Mukherjee, P., Hess, C. P., Han, E. T., & Henry, R. G. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.021 · Cited by 168
Persistent Angular Structure: New Insights from Diffusion MRI Data. Dummy Version
Jansons, K. M., & Alexander, D. C. (2003) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-45087-0_56 · Cited by 168
Parametric and non-parametric statistical analysis of DT-MRI data
Pajevic, S., & Basser, P. J. (2003) · Journal of Magnetic Resonance · doi:10.1016/s1090-7807(02)00178-7 · Cited by 162
Jones, D. K. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.922191 · Cited by 161
Self-citationInference of multiple fiber orientations in high angular resolution diffusion imaging
Hosey, T. P., Williams, G. B., & Ansorge, R. E. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20723 · Cited by 154
Jones, D. K., & Pierpaoli, C. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20466 · Cited by 145
Self-citationFiber Tracking in q-Ball Fields Using Regularized Particle Trajectories
Perrin, M., Poupon, C., Cointepas, Y., Rieul, B., Golestani, N., Pallier, C., Rivière, D., Constantinesco, A., Bihan, D. L., & Mangin, J. (2005) · Lecture notes in computer science · doi:10.1007/11505730_5 · Cited by 143
Comparison of bootstrap approaches for estimation of uncertainties of DTI parameters
Chung, S., Lü, Y., & Henry, R. G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.07.001 · Cited by 131
Using the wild bootstrap to quantify uncertainty in diffusion tensor imaging
Whitcher, B. J., Tuch, D. S., Wisco, J. J., Sorensen, A. G., & Wang, L. (2007) · Human Brain Mapping · doi:10.1002/hbm.20395 · Cited by 113
Mathematical framework for simulating diffusion tensor MR neural fiber bundles
Leemans, A., Sijbers, J., Verhoye, M., der Linden, A. V., & Dyck, D. V. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20418 · Cited by 80
Self-citationLabeling of ambiguous subvoxel fibre bundle configurations in high angular resolution diffusion MRI
Savadjiev, P., Campbell, J. S. W., Descoteaux, M., Rachid Deriche, B., Pike, G. B., & Kaleem Siddiqi, A. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.01.028 · Cited by 74
Exploiting peak anisotropy for tracking through complex structures
Seunarine, K. K., Cook, P. A., Hall, M. G., Embleton, K. V., Parker, G. J. M., & Alexander, D. C. (2007) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2007.4409168 · Cited by 64
Haroon, H. A., Morris, D. M., Embleton, K. V., Alexander, D. C., & Parker, G. J. M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2006528 · Cited by 47
Basser (2000) · doi:10.1002/1522-2594(200010)44:4<625::aid-mrm17>3.0.co;2-o
Cited by
MRtrix3: A fast, flexible and open software framework for medical image processing and visualisation
Tournier, J.-D., Smith, R., Raffelt, D., Tabbara, R., Dhollander, T., Pietsch, M., Christiaens, D., Jeurissen, B., Yeh, C.-H., & Connelly, A. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116137 · Cited by 2,974
Self-citationDenoising of diffusion MRI using random matrix theory
Veraart, J., Novikov, D. S., Christiaens, D., Ades-aron, B., Sijbers, J., & Fieremans, E. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.016 · Cited by 1,905
Self-citationJeurissen, B., Tournier, J.-D., Dhollander, T., Connelly, A., & Sijbers, J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.061 · Cited by 1,454
Self-citationDipy, a library for the analysis of diffusion MRI data
Garyfallidis, E., Brett, M., Amirbekian, B., Rokem, A., van der Walt, S., Descoteaux, M., Nimmo-Smith, I., & Contributors, D. (2014) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2014.00008 · Cited by 1,371
“…example the fiber orientation distribution function (fODF) obtained by fitting the CSD (constrained spherical deconvolution) model to diffusion data can be used as an estimate of the PDF, because it represents a fiber distribution associated with the measured diffusion signal (Jeurissen et al., 2011).”
MethodMRtrix: Diffusion tractography in crossing fiber regions
Tournier, J., Calamante, F., & Connelly, A. (2012) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22005 · Cited by 1,370
Self-citation
Metadata
- Authors
- Jeurissen, B., Leemans, A., Jones, D. K., Tournier, J., & Sijbers, J.
- Venue
- Human Brain Mapping
- Publisher
- Wiley
- Published
- 2011-02-14
- Volume
- 32
- Issue
- 3
- Pages
- 461-479
- ISSN
- 1065-9471 (ISSN-L)
- 1097-0193
- OpenAlex
- W2053884965
- Cited by
- 369
- References
- 50
- FWCI
- 18.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.