Potential pitfalls of functional MRI using conventional gradient‐recalled echo techniques
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The conventional gradient‐recalled echo technique, FLASH, has widely been used for functional MRI. FLASH results at 4 T with short TEs of 10–20 ms mimic those at 1.5 T with TEs of 25–50 ms or longer. Under these conditions, large venous vessels dominate the activated area; however, the use of longer TEs at 4 T reveals activation in gray matter areas as well as large vessels. Inflow effects of large vessels can be greatly reduced with centric‐reordering of phase‐encoding steps and inter‐image delay. Finger and toe movement paradigms show that functional activation maps are consistent with classical somatotopic maps, and are specific to the tasks. Navigator‐based motion correction generates functional maps with larger activation areas by reducing physiological noise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
PENFIELD, W., & BOLDREY, E. (1937) · Brain · doi:10.1093/brain/60.4.389 · Cited by 4,188
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Self-citationFox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Self-citationThulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Lai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300318 · Cited by 390
Functional magnetic resonance imaging of Brocaʼs area during internal speech
Hinke, R. M., Hu, X., Stillman, A. E., Kim, S.-G., Merkle, H., Salmi, R., & Ugurbil, K. (1993) · NeuroReport · doi:10.1097/00001756-199306000-00018 · Cited by 293
Self-citation
Cited by
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
“[7,8]).”
Kim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001
Self-citationThe neural basis of the blood–oxygen–level–dependent functional magnetic resonance imaging signal
Logothetis, N. K. (2002) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2002.1114 · Cited by 958
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Self-citationBiophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Self-citationAnalysis of fMRI and finger tracking training in subjects with chronic stroke
Carey, J. R., Kimberley, T. J., Lewis, S. M., Auerbach, E. J., Dorsey, L., Rundquist, P., & Ugurbil, K. (2002) · Brain · doi:10.1093/brain/awf091 · Cited by 562
Experimental determination of the BOLD field strength dependence in vessels and tissue
Gati, J. S., Menon, R. S., Uǧurbil, K., & Rutt, B. K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380220 · Cited by 523
Self-citationRetrospective estimation and correction of physiological fluctuation in functional MRI
Hu, X., Le, T. H., Parrish, T., & Erhard, P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340211 · Cited by 475
Self-citationUludağ, K., Müller-Bierl, B., & Uğurbil, K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.051 · Cited by 450
Self-citationYou, S. H., Jang, S. H., Kim, Y.-H., Hallett, M., Ahn, S. H., Kwon, Y.-H., Kim, J. H., & Lee, M. Y. (2005) · Stroke · doi:10.1161/01.str.0000162715.43417.91 · Cited by 422
Menon, R. S., Ogawa, S., Hu, X., Strupp, J. P., Anderson, P., & Uǧurbil, K. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330323 · Cited by 421
Self-citationMotor Area Activity During Mental Rotation Studied by Time-Resolved Single-Trial fMRI
Richter, W., Somorjai, R., Summers, R., Jarmasz, M., Menon, R. S., Gati, J. S., Georgopoulos, A. P., Tegeler, C., Ugurbil, K., & Kim, S.-G. (2000) · Journal of Cognitive Neuroscience · doi:10.1162/089892900562129 · Cited by 416
Self-citationHow well do we understand the neural origins of the fMRI BOLD signal?
Arthurs, O. J., & Boniface, S. (2002) · Trends in Neurosciences · doi:10.1016/s0166-2236(00)01995-0 · Cited by 378
Imaging retinotopic maps in the human brain
Wandell, B. A., & Winawer, J. (2011) · Vision Research · doi:10.1016/j.visres.2010.08.004 · Cited by 373
Origin of Negative Blood Oxygenation Level—Dependent fMRI Signals
Harel, N., Lee, S.-P., Nagaoka, T., Kim, D.-S., & Kim, S.-G. (2002) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200208000-00002 · Cited by 369
Self-citationCohen, E. R., Ugurbil, K., & Kim, S.-G. (2002) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200209000-00002 · Cited by 354
Self-citationON THE CHARACTERISTICS OF FUNCTIONAL MAGNETIC RESONANCE IMAGING OF THE BRAIN
Ogawa, S., Menon, R. S., Kim, S.-G., & Ugurbil, K. (1998) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.27.1.447 · Cited by 343
Self-citationLocalized cerebral blood flow response at submillimeter columnar resolution
Duong, T. Q., Kim, D.-S., Uğurbil, K., & Kim, S.-G. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191101098 · Cited by 342
Self-citationElectrical stimulation driving functional improvements and cortical changes in subjects with stroke
Kimberley, T. J., Lewis, S. M., Auerbach, E. J., Dorsey, L. L., Lojovich, J. M., & Carey, J. R. (2004) · Experimental Brain Research · doi:10.1007/s00221-003-1695-y · Cited by 318
Yacoub, E., Shmuel, A., Logothetis, N., & Uğurbil, K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.05.020 · Cited by 308
Self-citationFunctional activation in motor cortex reflects the direction and the degree of handedness
Dassonville, P., Zhu, X.-H., Ugurbil, K., Kim, S.-G., & Ashe, J. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.25.14015 · Cited by 300
Self-citationSchurr, A., Miller, J. J., Payne, R. S., & Rigor, B. M. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-01-00034.1999 · Cited by 295
Spatio-temporal point-spread function of fMRI signal in human gray matter at 7 Tesla
Shmuel, A., Yacoub, E., Chaimow, D., Logothetis, N. K., & Ugurbil, K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.12.030 · Cited by 294
“These veins show large response amplitude, as demonstrated by Menon et al. (1993), Kim et al. (1994) , Cheng et al. (2001), Yacoub et al. (2001a,b, 2005), and others.”
BackgroundMethodOcular Dominance in Human V1 Demonstrated by Functional Magnetic Resonance Imaging
Menon, R. S., Ogawa, S., Strupp, J. P., & Uǧurbil, K. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.77.5.2780 · Cited by 293
Self-citationDiffusion-weighted spin-echo fMRI at 9.4 T: Microvascular/tissue contribution to BOLD signal changes
Lee, S.-P., Silva, A. C., Ugurbil, K., & Kim, S.-G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<919::aid-mrm12>3.0.co;2-8 · Cited by 288
Self-citationWu, G.-R., Liao, W., Stramaglia, S., Ding, J.-R., Chen, H., & Marinazzo, D. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.01.003 · Cited by 284
Evaluation of the early response in fMRI in individual subjects using short stimulus duration
Hu, X., Le, T. H., & Uǧurbil, K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370612 · Cited by 255
Self-citationShmuel, A., Chaimow, D., Raddatz, G., Ugurbil, K., & Yacoub, E. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.08.040 · Cited by 111
“…voxels were rank ordered separately according to the inverse of their GE signal and their response amplitude (see previous use of these criteria for identifying macroscopic blood vessels by Menon et al. (1993), Kim et al. (1994), Cheng et al. (2001), Shmuel et al. (2007a), and Olman et al. (2007)).”
Bellgowan, P. S. F., Bandettini, P. A., van Gelderen, P., Martin, A., & Bodurka, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.042 · Cited by 84
“A likely source for this difference may be differences in neurovasculature as the predominant source of physiological noise during fMRI is brain vasculature (Kim et al., 1994).”
BackgroundGr�ne, M., Pillekamp, F., Schwindt, W., & Hoehn, M. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199907)42:1<118::aid-mrm16>3.0.co;2-t · Cited by 29
Metadata
- Authors
- Kim, S., Hendrich, K., Hu, X., Merkle, H., & Uǧurbil, K.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 1994-03
- Volume
- 7
- Issue
- 1-2
- Pages
- 69-74
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2123844051
- Cited by
- 224
- References
- 10
- FWCI
- 14.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.