Position and orientation in space of bones during movement: anatomical frame definition and determination
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
This paper deals with methodological problems related to the reconstruction of the position and orientation of the human pelvis and the lower limb bones in space during the execution of locomotion and physical exercises using a stereophotogrammetric system. The intention is to produce a means of quantitative description of joint kinematics and dynamics for both research and application. Anatomical landmarks and bone-embedded anatomical reference systems are defined. A contribution is given to definition of variables and relevant terminology. The concept of anatomical landmark calibration is introduced and relevant experimental approaches presented. The problem of data sharing is also addressed. This material is submitted to the scientific community for consideration as a basis for standardization. RELEVANCE: In order to make movement analysis effective in the solution of clinical problems, a structured conceptual background is needed in addition to standardized definitions and methods. Technical solutions which make data sharing and relevant data banks possible are also of primary importance. This paper makes suggestions in this context.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Kinematic Notation for Lower-Pair Mechanisms Based on Matrices
Denavit, J., & Hartenberg, R. S. (1955) · Journal of Applied Mechanics · doi:10.1115/1.4011045 · Cited by 4,551
Warwick, R., Williams, P. L., Dyson, M., & Bannister, L. (1985) · The British Journal of Radiology · doi:10.1259/0007-1285-58-694-1029 · Cited by 4,532
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures
Delp, S. L., Loan, J. P., Hoy, M. G., Zajac, F. E., Topp, E. L., & Rosen, J. M. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102791 · Cited by 2,005
A comparison of the accuracy of several hip center location prediction methods
Bell, A. L., Pedersen, D. R., & Brand, R. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90054-7 · Cited by 884
Vaughan, C. L., Davis, B. L., & O’Connor, J. (1992) · Medical Entomology and Zoology · Cited by 798
A study of lower-limb mechanics during stair-climbing.
Andriacchi, T. P., Andersson, G. B., Fermier, R. W., Stern, D., & Galante, J. O. (1980) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198062050-00008 · Cited by 765
Determining the movements of the skeleton using well-configured markers
Söderkvist, I., & Wedin, P.-Å. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90098-y · Cited by 735
Rigid body motion calculated from spatial co-ordinates of markers
Spoor, C. W., & Veldpaus, F. E. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90020-2 · Cited by 579
Physical examination of the spine and extremities
Hoppenfeld, S. (1979) · Medical Entomology and Zoology · Cited by 546
Cited by
Wu, G., Siegler, S., Allard, P., Kirtley, C., Leardini, A., Rosenbaum, D., Whittle, M., D’Lima, D. D., Cristofolini, L., Witte, H., et al. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00222-6 · Cited by 3,242
Self-citationHuman movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
Self-citationLu, T.-W., & O’Connor, J. J. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00158-4 · Cited by 924
Position and orientation in space of bones during movement: experimental artefacts
Cappozzo, A., Catani, F., Leardini, A., Benedetti, M., & Della Croce, U. (1996) · Clinical Biomechanics · doi:10.1016/0268-0033(95)00046-1 · Cited by 756
Self-citationRear-foot, mid-foot and fore-foot motion during the stance phase of gait
Leardini, A., Benedetti, M. G., Berti, L., Bettinelli, D., Nativo, R., & Giannini, S. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.05.017 · Cited by 692
Self-citationColyer, S. L., Evans, M., Cosker, D. P., & Salo, A. I. T. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0139-y · Cited by 629
Gait analysis methods in rehabilitation
Baker, R. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-4 · Cited by 587
Adjustments to McConville et al. and Young et al. body segment inertial parameters
Dumas, R., Chèze, L., & Verriest, J.-P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.02.013 · Cited by 554
Human movement analysis using stereophotogrammetry
Della Croce, U., Leardini, A., Chiari, L., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.003 · Cited by 544
Self-citationRepeatability of gait data using a functional hip joint centre and a mean helical knee axis
Besier, T. F., Sturnieks, D. L., Alderson, J. A., & Lloyd, D. G. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00087-3 · Cited by 532
A new anatomically based protocol for gait analysis in children
Leardini, A., Sawacha, Z., Paolini, G., Ingrosso, S., Nativo, R., & Benedetti, M. G. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.12.018 · Cited by 491
Self-citationSurface-marker cluster design criteria for 3-D bone movement reconstruction
Cappozzo, A., Cappello, A., Croce, U. D., & Pensalfini, F. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.649988 · Cited by 456
Self-citationHuman movement analysis using stereophotogrammetry
Chiari, L., Croce, U. D., Leardini, A., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.04.004 · Cited by 441
Self-citationValidation of a functional method for the estimation of hip joint centre location
Leardini, A., Cappozzo, A., Catani, F., Toksvig-Larsen, S., Petitto, A., Sforza, V., Cassanelli, G., & Giannini, S. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00148-1 · Cited by 415
Self-citationCollins, T. D., Ghoussayni, S. N., Ewins, D. J., & Kent, J. A. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.04.004 · Cited by 365
Schmitz, A., Silder, A., Heiderscheit, B., Mahoney, J., & Thelen, D. G. (2009) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.10.008 · Cited by 347
“The additional 19 markers were used to enhance segment tracking and reduce skin motion artifact (Cappozzo et al., 1995).”
MethodHandling of impact forces in inverse dynamics
Bisseling, R. W., & Hof, A. L. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.07.021 · Cited by 337
Quantitative comparison of five current protocols in gait analysis
Ferrari, A., Benedetti, M. G., Pavan, E., Frigo, C., Bettinelli, D., Rabuffetti, M., Crenna, P., & Leardini, A. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.11.009 · Cited by 334
Self-citationData management in gait analysis for clinical applications
Benedetti, M., Catani, F., Leardini, A., Pignotti, E., & Giannini, S. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00041-7 · Cited by 326
Self-citationCorazza, S., Mündermann, L., Chaudhari, A. M., Demattio, T., Cobelli, C., & Andriacchi, T. P. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9122-8 · Cited by 325
Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., & Davies, J. (2018) · Sensors · doi:10.3390/s18030719 · Cited by 318
“Ferrari et al. [10] compared joint angles obtained from IMUs used with a biomechanical model called Outwalk to those obtained from an optoelectronic system (VICON) used with the Calibration Anatomical System Technique [56].”
Ambulatory measurement of 3D knee joint angle
Favre, J., Jolles, B. M., Aissaoui, R., & Aminian, K. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.12.003 · Cited by 316
McLean, S. G., Walker, K., Ford, K. R., Myer, G. D., Hewett, T. E., & van den Bogert, A. J. (2005) · British Journal of Sports Medicine · doi:10.1136/bjsm.2005.018598 · Cited by 310
Functional calibration procedure for 3D knee joint angle description using inertial sensors
Favre, J., Aissaoui, R., Jolles, B. M., de Guise, J. A., & Aminian, K. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.06.025 · Cited by 301
Gait abnormalities in minimally impaired multiple sclerosis patients
Benedetti, M. G., Piperno, R., Simoncini, L., Bonato, P., Tonini, A., & Giannini, S. (1999) · Multiple Sclerosis Journal · doi:10.1177/135245859900500510 · Cited by 289
Stagni, R., Fantozzi, S., Cappello, A., & Leardini, A. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.11.012 · Cited by 283
Self-citationWhole body inverse dynamics over a complete gait cycle based only on measured kinematics
Ren, L., Jones, R. K., & Howard, D. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.06.001 · Cited by 283
Three-dimensional gait analysis of obese adults
Lai, P. P. K., Leung, A. K. L., Li, A. N. M., & Zhang, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.02.004 · Cited by 283
Fern'ndez-Baena, A., Susin, A., & Lligadas, X. (2012) · 2012 Fourth International Conference on Intelligent Networking and Collaborative Systems · doi:10.1109/incos.2012.66 · Cited by 281
An optimized protocol for hip joint centre determination using the functional method
Camomilla, V., Cereatti, A., Vannozzi, G., & Cappozzo, A. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.02.008 · Cited by 269
Self-citationBonnechère, B., Jansen, B., Salvia, P., Bouzahouene, H., Omelina, L., Moiseev, F., Sholukha, V., Cornelis, J., Rooze, M., & Van Sint Jan, S. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2013.09.018 · Cited by 267
Joint kinematics estimate using wearable inertial and magnetic sensing modules
Picerno, P., Cereatti, A., & Cappozzo, A. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.04.003 · Cited by 262
Self-citationAn anatomically based protocol for the description of foot segment kinematics during gait
Leardini, A., Benedetti, M. G., Catani, F., Simoncini, L., & Giannini, S. (1999) · Clinical Biomechanics · doi:10.1016/s0268-0033(99)00008-x · Cited by 257
Self-citationDella Croce, U., Cappozzo, A., & Kerrigan, D. C. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513282 · Cited by 256
Self-citationMeasurement of the screw-home motion of the knee is sensitive to errors in axis alignment
Piazza, S. J., & Cavanagh, P. R. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00056-7 · Cited by 244
“Local coordinate systems were determined for each segment from the measured locations of anatomical control points (ACPs) using a method similar to that of Cappozzo et al. (1995).”
MethodEffects of hip joint centre mislocation on gait analysis results
Stagni, R., Leardini, A., Cappozzo, A., Grazia Benedetti, M., & Cappello, A. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00093-2 · Cited by 241
Self-citationAkbarshahi, M., Schache, A. G., Fernandez, J. W., Baker, R., Banks, S., & Pandy, M. G. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.01.002 · Cited by 232
Powers, C. M., Bolgla, L. A., Callaghan, M. J., Collins, N., & Sheehan, F. T. (2012) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2012.0301 · Cited by 222
‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensors
Cutti, A. G., Ferrari, A., Garofalo, P., Raggi, M., Cappello, A., & Ferrari, A. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0545-x · Cited by 218
“The definition of the anatomical CSs was partially based on the external anatomical landmarks described in [6].”
BackgroundMethodA geometric model of the human ankle joint
Leardini, A., O'Connor, J. J., Catani, F., & Giannini, S. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00022-6 · Cited by 214
Self-citationSkin movement artefact assessment and compensation in the estimation of knee-joint kinematics
Lucchetti, L., Cappozzo, A., Cappello, A., & Croce, U. D. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00083-9 · Cited by 211
Self-citationCeseracciu, E., Sawacha, Z., & Cobelli, C. (2014) · PLoS ONE · doi:10.1371/journal.pone.0087640 · Cited by 210
“It is based on Cappozzo et al. 1995 [16] that is a well recognized standard procedure for marker-based gait analysis.”
MethodPassive Back Support Exoskeleton Improves Range of Motion Using Flexible Beams
Näf, M. B., Koopman, A. S., Baltrusch, S., Rodriguez-Guerrero, C., Vanderborght, B., & Lefeber, D. (2018) · Frontiers in Robotics and AI · doi:10.3389/frobt.2018.00072 · Cited by 207
“marker clusters using a probe with six markers (Cappozzo et al., 1995).”
MethodPiazza, S. J., Okita, N., & Cavanagh, P. R. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00052-5 · Cited by 199
“The global coordinates of four anatomical control points (ACP) were determined using a pointer fitted with reflective markers (Cappozzo et al., 1995; Erdemir and Piazza, 1999) at the same time that global coordinates of the four cluster markers were recorded (Fig.”
MethodActive and passive contributions to joint kinetics during walking in older adults
Silder, A., Heiderscheit, B., & Thelen, D. G. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.02.016 · Cited by 197
“Whole body motion was tracked using 23 anatomical markers placed on identifiable landmarks and 19 additional markers to aid in tracking and minimize skin motion artifact (Cappozzo et al., 1995).”
MethodLandry, S. C., McKean, K. A., Hubley-Kozey, C. L., Stanish, W. D., & Deluzio, K. J. (2007) · The American Journal of Sports Medicine · doi:10.1177/0363546507300823 · Cited by 196
Effects of a passive exoskeleton on the mechanical loading of the low back in static holding tasks
Koopman, A. S., Kingma, I., Faber, G. S., de Looze, M. P., & van Dieën, J. H. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.11.033 · Cited by 192
“Prior to the measurements, for each participant, cluster markers were related to anatomical landmarks using pointer measurements (Cappozzo et al., 1995).”
MethodThe accuracy of several pose estimation methods for 3D joint centre localisation
Needham, L., Evans, M., Cosker, D. P., Wade, L., McGuigan, P. M., Bilzon, J. L., & Colyer, S. L. (2021) · Scientific Reports · doi:10.1038/s41598-021-00212-x · Cited by 190
Worsley, P., Warner, M., Mottram, S., Gadola, S., Veeger, H. E. J., Hermens, H., Morrissey, D., Little, P., Cooper, C., Carr, A., et al. (2013) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2012.06.010 · Cited by 186
“The bony landmarks of posterior acromion (AA), root of medial spine (TS), and inferior angle (AI) were calibrated with respect to AMC before testing began using the calibrated anatomical systems technique (CAST) method.(4) An anatomical local coordinate system was then constructed from these bony landmarks following t…”
Lencioni, T., Carpinella, I., Rabuffetti, M., Marzegan, A., & Ferrarin, M. (2019) · Scientific Data · doi:10.1038/s41597-019-0323-z · Cited by 184
(2010) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2010.0302 · Cited by 182
Ferrari, A., Cutti, A. G., Garofalo, P., Raggi, M., Heijboer, M., Cappello, A., & Davalli, A. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0544-y · Cited by 181
“(2) its performances are widely tested and documented [1, 2, 8]; (3) it was the reference protocol used in [17]; (4) it requires the use of clusters of markers, which can be thought as SU, and the definition of technical frames, which are analog to the local CS of a SU.”
MethodBrown, T. N., Palmieri-Smith, R. M., & McLean, S. G. (2009) · British Journal of Sports Medicine · doi:10.1136/bjsm.2008.055954 · Cited by 176
“The potential exists, however, for excessive skin movement artefact to result in erroneous data interpretation.”
BackgroundArmed against falls: the contribution of arm movements to balance recovery after tripping
Pijnappels, M., Kingma, I., Wezenberg, D., Reurink, G., & van Dieën, J. H. (2010) · Experimental Brain Research · doi:10.1007/s00221-009-2088-7 · Cited by 170
Sawacha, Z., Gabriella, G., Cristoferi, G., Guiotto, A., Avogaro, A., & Cobelli, C. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.07.007 · Cited by 169
The effect of running speed on knee mechanical loading in females during side cutting
Vanrenterghem, J., Venables, E., Pataky, T., & Robinson, M. A. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.06.029 · Cited by 163
Multiple anatomical landmark calibration for optimal bone pose estimation
Cappello, A., Cappozzo, A., La Palombara, P. F., Lucchetti, L., & Leardini, A. (1997) · Human Movement Science · doi:10.1016/s0167-9457(96)00055-3 · Cited by 161
Self-citationBouvier, B., Duprey, S., Claudon, L., Dumas, R., & Savescu, A. (2015) · Sensors · doi:10.3390/s150818813 · Cited by 133
“1 mm in position, [6]), some limitations of use are involved such as lengthy camera calibration time, the restricted area of measurement (i.”
BackgroundMethodUse of wearable sensor technology in gait, balance, and range of motion analysis
Díaz, S., Stephenson, J. B., & Labrador, M. A. (2019) · Applied Sciences · doi:10.3390/app10010234 · Cited by 132
Blair, S., Duthie, G., Robertson, S., Hopkins, W., & Ball, K. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.03.031 · Cited by 117
Lorenzetti, S., Gülay, T., Stoop, M., List, R., Gerber, H., Schellenberg, F., & Stüssi, E. (2012) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e318267918b · Cited by 81
“cution of the squat is important to avoid injury and to maximize the positive effects of training (6,7,10,14).”
BackgroundSelfslagh, A., Shokur, S., Campos, D. S. F., Donati, A. R. C., Almeida, S., Yamauti, S. Y., Coelho, D. B., Bouri, M., & Nicolelis, M. A. L. (2019) · Scientific Reports · doi:10.1038/s41598-019-43041-9 · Cited by 78
Measurement of Multi-segment Foot Joint Angles During Gait Using a Wearable System
Rouhani, H., Favre, J., Crevoisier, X., & Aminian, K. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4006674 · Cited by 72
Prediction of gait trajectories based on the Long Short Term Memory neural networks
Zaroug, A., Garofolini, A., Lai, D. T. H., Mudie, K., & Begg, R. (2021) · PLOS ONE · doi:10.1371/journal.pone.0255597 · Cited by 48
Middleton, K. J., Mills, P. M., Elliott, B. C., & Alderson, J. A. (2016) · Sports Biomechanics · doi:10.1080/14763141.2016.1163413 · Cited by 39
Locomotor patterns change over time when exposed to an uneven surface
Kent, J. A., Sommerfeld, J. H., Mukherjee, M., Takahashi, K. Z., & Stergiou, N. (2019) · Journal of Experimental Biology · doi:10.1242/jeb.202093 · Cited by 20
Pozuelo-Calvo, R., Serrano-Garcia, A., Archilla-Bonilla, Y., Ruiz-Zafra, A., Noguera-Garcia, M., Benghazi-Akhlaki, K., Membrilla-Mesa, M., DiCaudo, C., & Heredia-Jimenez, J. (2025) · Diagnostics · doi:10.3390/diagnostics15050575 · Cited by 2
“The calibrated anatomical systems technique (CAST) was used to track markers placed on specific anatomical landmarks [34].”
Metadata
- Authors
- Cappozzo, A., Catani, F., Della Croce, U., & Leardini, A.
- Venue
- Clinical Biomechanics
- Publisher
- Elsevier BV
- Published
- 1995-06
- Volume
- 10
- Issue
- 4
- Pages
- 171-178
- ISSN
- 0268-0033 (ISSN-L)
- OpenAlex
- W2086801037
- Cited by
- 1,677
- References
- 18
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.