Implantable biohybrid artificial organs
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Biohybrid artificial organs encompass all devices which substitute for an organ or tissue function and incorporate both synthetic materials and living cells. This review concerns implantable immunoisolation devices in which the tissue is protected from immune rejection by enclosure within a semipermeable membrane. Two critical areas are discussed in detail: (i) Device design and performance as it relates to maintenance of cell viability and function. Attention is focussed on oxygen supply limitation and how it is affected by tissue density and the development of materials that induce neovascularization at the host tissue-membrane interface; and (ii) Protection from immune rejection. Our current knowledge of the mechanisms that may be operative in immune rejection in the presence of a semipermeable membrane barrier is limited. Nonetheless, recent studies shed light on the role played by membrane properties in preventing immune rejection, and many studies demonstrate substantial progress towards clinically useful implantable immunoisolation devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microencapsulated Islets as Bioartificial Endocrine Pancreas
Lim, F., & Sun, A. M. (1980) · Science · doi:10.1126/science.6776628 · Cited by 2,377
Insulin independence in a type 1 diabetic patient after encapsulated islet transplantation
Soon-Shiong, P., Heintz, R. E., Merideth, N., Yao, Q. X., Yao, Z., Zheng, T., Murphy, M., Moloney, M. K., Schmehl, M., Harris, M., et al. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90067-1 · Cited by 659
Effect of Hypoxia on Insulin Secretion by Isolated Rat and Canine Islets of Langerhans
Dionne, K. E., Colton, C. K., & Lyarmush, M. (1993) · Diabetes · doi:10.2337/diab.42.1.12 · Cited by 436
Self-citationMaintenance of Normoglycemia in Diabetic Mice by Subcutaneous Xenografts of Encapsulated Islets
Lacy, P. E., Hegre, O. D., Gerasimidi-Vazeou, A., Gentile, F. T., & Dionne, K. E. (1991) · Science · doi:10.1126/science.1763328 · Cited by 345
Goosen, M. F. A., O'Shea, G. M., Gharapetian, H. M., Chou, S., & Sun, A. M. (1985) · Biotechnology and Bioengineering · doi:10.1002/bit.260270207 · Cited by 330
Long-term reversal of diabetes by the injection of immunoprotected islets.
Soon-Shiong, P., Feldman, E., Nelson, R., Heintz, R., Yao, Q., Yao, Z., Zheng, T., Merideth, N., Skjak-Braek, G., & Espevik, T. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.12.5843 · Cited by 236
Biohybrid Artificial Pancreas: Long-Term Implantation Studies in Diabetic, Pancreatectomized Dogs
Sullivan, S. J., Maki, T., Borland, K. M., Mahoney, M. D., Solomon, B. A., Muller, T. E., Monaco, A. P., & Chick, W. L. (1991) · Science · doi:10.1126/science.2024124 · Cited by 221
Bioengineering in Development of the Hybrid Artificial Pancreas
Colton, C. K., & Avgoustiniatos, E. S. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2891229 · Cited by 211
Self-citationSUCCESSFUL REVERSAL OF SPONTANEOUS DIABETES IN DOGS BY INTRAPERITONEAL MICROENCAPSULATED ISLETS
Soon-Shiong, P., Feldman, E., Nelson, R., Komtebedde, J., Smidsrod, O., Skjak-Braek, G., Espevik, T., Heintz, R., & Lee, M. (1992) · Transplantation · doi:10.1097/00007890-199211000-00001 · Cited by 201
Diffusion and partitioning of proteins in charged agarose gels
Johnson, E. M., Berk, D. A., Jain, R. K., & Deen, W. M. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80328-0 · Cited by 199
Cited by
The design of scaffolds for use in tissue engineering. Part I. Traditional factors
Yang, S., Leong, K.-F., Du, Z., & Chua, C.-K. (2001) · Tissue Engineering · doi:10.1089/107632701753337645 · Cited by 2,234
Small-scale systems for in vivo drug delivery
LaVan, D. A., McGuire, T., & Langer, R. (2003) · Nature Biotechnology · doi:10.1038/nbt876 · Cited by 1,304
Osteogenesis and angiogenesis: The potential for engineering bone
Bone & Joint Research Group, C. F. H. D., Kanczler, J., & Oreffo, R. (2008) · European Cells and Materials · doi:10.22203/ecm.v015a08 · Cited by 987
Engineering Hydrogels as Extracellular Matrix Mimics
Geckil, H., Xu, F., Zhang, X., Moon, S., & Demirci, U. (2010) · Nanomedicine · doi:10.2217/nnm.10.12 · Cited by 944
Development of biocompatible synthetic extracellular matrices for tissue engineering
Kim, B.-S., & Mooney, D. J. (1998) · Trends in Biotechnology · doi:10.1016/s0167-7799(98)01191-3 · Cited by 931
Mikos, A. G., Herring, S. W., Ochareon, P., Elisseeff, J., Lu, H. H., Kandel, R., Schoen, F. J., Toner, M., Mooney, D., Atala, A., et al. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.3307 · Cited by 598
Park, K. I., Teng, Y. D., & Snyder, E. Y. (2002) · Nature Biotechnology · doi:10.1038/nbt751 · Cited by 554
Angiogenesis in Tissue Engineering: Breathing Life into Constructed Tissue Substitutes
Laschke, M. W., Harder, Y., Amon, M., Martin, I., Farhadi, J., Ring, A., Torio-Padron, N., Schramm, R., Rücker, M., Junker, D., et al. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2093 · Cited by 546
Atala, A., Kasper, F. K., & Mikos, A. G. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004890 · Cited by 544
Bioabsorbable polymer scaffolds for tissue engineering capable of sustained growth factor delivery
Sheridan, M. H., Shea, L. D., Peters, M. C., & Mooney, D. J. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00138-8 · Cited by 528
Synthesis, properties and biomedical applications of poly(glycerol sebacate) (PGS): A review
Rai, R., Tallawi, M., Grigore, A., & Boccaccini, A. R. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.02.001 · Cited by 477
Compressive and shear properties of alginate gel: Effects of sodium ions and alginate concentration
LeRoux, M. A., Guilak, F., & Setton, L. A. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199910)47:1<46::aid-jbm6>3.0.co;2-n · Cited by 444
Perets, A., Baruch, Y., Weisbuch, F., Shoshany, G., Neufeld, G., & Cohen, S. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10542 · Cited by 439
Murphy, W. L., Peters, M. C., Kohn, D. H., & Mooney, D. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00120-4 · Cited by 412
RAJAGOPALAN, S., & ROBB, R. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.06.001 · Cited by 392
Bioactive Glass Stimulates the Secretion of Angiogenic Growth Factors and Angiogenesis in Vitro
Day, R. M. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.768 · Cited by 389
Engineering bone: challenges and obstacles
Logeart-Avramoglou, D., Anagnostou, F., Bizios, R., & Petite, H. (2005) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2005.tb00338.x · Cited by 380
Cells, scaffolds, and molecules for myocardial tissue engineering
Leor, J., Amsalem, Y., & Cohen, S. (2005) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2004.10.003 · Cited by 344
Endothelialized Microvasculature Based on a Biodegradable Elastomer
Fidkowski, C., Kaazempur-Mofrad, M. R., Borenstein, J., Vacanti, J. P., Langer, R., & Wang, Y. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.302 · Cited by 343
Microcapsules and microcarriers for in situ cell delivery☆
Hernández, R. M., Orive, G., Murua, A., & Pedraz, J. L. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.02.004 · Cited by 340
Self-Assembled Proteins and Peptides for Regenerative Medicine
Hosseinkhani, H., Hong, P.-D., & Yu, D.-S. (2013) · Chemical Reviews · doi:10.1021/cr300131h · Cited by 324
Perfusion Improves Tissue Architecture of Engineered Cardiac Muscle
Carrier, R. L., Rupnick, M., Langer, R., Schoen, F. J., Freed, L. E., & Vunjak-Novakovic, G. (2002) · Tissue Engineering · doi:10.1089/107632702753724950 · Cited by 323
Biocompatibility of mannuronic acid-rich alginates
Klöck, G., Pfeffermann, A., Ryser, C., Gröhn, P., Kuttler, B., Hahn, H.-J., & Zimmermann, U. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00204-9 · Cited by 320
Glicklis, R., Merchuk, J. C., & Cohen, S. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20086 · Cited by 316
“…¼ 1@ r2@r r 2Deff @S @r rO2 x jreaction ð4Þ Where r is the spheroid radius, Amax = 3 10 8mole/cm3s, Ks = 0.44 mmHg, and Deff (the effectiveness diffusion coefficient) = 1.6 10 5cm2/s, which are the average values for cultured islet cells and hepatocytes (Colton, 1995; Yarmush et al., 1992).”
BackgroundInfluentialScharp, D. W., & Marchetti, P. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.018 · Cited by 314
Pullulan: A novel molecule for biomedical applications
Singh, R. S., Kaur, N., Rana, V., & Kennedy, J. F. (2017) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2017.04.089 · Cited by 314
Micro- and nanoscale structures for tissue engineering constructs
Desai, T. A. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00087-4 · Cited by 302
Polymers in cell encapsulation from an enveloped cell perspective
de Vos, P., Lazarjani, H. A., Poncelet, D., & Faas, M. M. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.11.005 · Cited by 298
“pituitary disorders [9], central nervous system insufficiency [10], and diabetes mellitus [11].”
Duvivier-Kali, V. F., Omer, A., Parent, R. J., O’Neil, J. J., & Weir, G. C. (2001) · Diabetes · doi:10.2337/diabetes.50.8.1698 · Cited by 291
Zhang, X. Z., Leary, M., Tang, H. P., Song, T., & Qian, M. (2018) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2018.05.002 · Cited by 285
Cruise, G. M., Hegre, O. D., Lamberti, F. V., Hager, S. R., Hill, R., Scharp, D. S., & Hubbell, J. A. (1999) · Cell Transplantation · doi:10.1177/096368979900800310 · Cited by 273
Young, S., Patel, Z. S., Kretlow, J. D., Murphy, M. B., Mountziaris, P. M., Baggett, L. S., Ueda, H., Tabata, Y., Jansen, J. A., Wong, M., et al. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0510 · Cited by 255
Considerations for successful transplantation of encapsulated pancreatic islets
de Vos, P., Hamel, A. F., & Tatarkiewicz, K. (2002) · Diabetologia · doi:10.1007/s00125-001-0729-x · Cited by 252
Engineering vascular networks in porous polymer matrices
Peters, M. C., Polverini, P. J., & Mooney, D. J. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10134 · Cited by 238
Kumar, A., Mandal, S., Barui, S., Vasireddi, R., Gbureck, U., Gelinsky, M., & Basu, B. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.01.001 · Cited by 225
Beyond micromachining: the potential of diatoms
Parkinson, J., & Gordon, R. (1999) · Trends in Biotechnology · doi:10.1016/s0167-7799(99)01321-9 · Cited by 222
Biomaterials for the central nervous system
Zhong, Y., & Bellamkonda, R. V. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0071 · Cited by 221
“The survival of the cells is also affected due to a large distance (if more than a few hundredmicrometres) to the nearest capillary (Langer & Vacanti 1993; Colton 1995).”
BackgroundCardiac Tissue Engineering in an In Vivo Vascularized Chamber
Morritt, A. N., Bortolotto, S. K., Dilley, R. J., Han, X., Kompa, A. R., McCombe, D., Wright, C. E., Itescu, S., Angus, J. A., & Morrison, W. A. (2007) · Circulation · doi:10.1161/circulationaha.106.657379 · Cited by 221
Role of hyaluronan in angiogenesis and its utility to angiogenic tissue engineering
Pardue, E. L., Ibrahim, S., & Ramamurthi, A. (2008) · Organogenesis · doi:10.4161/org.4.4.6926 · Cited by 208
O'Sullivan, E. S., Vegas, A., Anderson, D. G., & Weir, G. C. (2011) · Endocrine Reviews · doi:10.1210/er.2010-0026 · Cited by 207
Lanza, R. P., Hayes, J. L., & Chick, W. L. (1996) · Nature Biotechnology · doi:10.1038/nbt0996-1107 · Cited by 206
Bone Regeneration via a Mineral Substrate and Induced Angiogenesis
Murphy, W. L., Simmons, C. A., Kaigler, D., & Mooney, D. J. (2004) · Journal of Dental Research · doi:10.1177/154405910408300304 · Cited by 200
“The vasculature provides for the mass transport requirements of the tissue (Colton, 1995), may deliver circulating stem cells that can participate in bone formation (Prockop, 1997), and facilitates cross-talk between endothelial cells and preosteoblasts to direct their differentiation (Villars et al.”
BackgroundCardiovascular tissue engineering
Rabkin, E., & Schoen, F. J. (2002) · Cardiovascular Pathology · doi:10.1016/s1054-8807(02)00130-8 · Cited by 200
Malda, J., Woodfield, T. B. F., van der Vloodt, F., Kooy, F. K., Martens, D. E., Tramper, J., Blitterswijk, C. A. V., & Riesle, J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.028 · Cited by 200
Endothelial Differentiation of Mesenchymal Stromal Cells
Janeczek Portalska, K., Leferink, A., Groen, N., Fernandes, H., Moroni, L., van Blitterswijk, C., & de Boer, J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0046842 · Cited by 199
“Metabolically active cells must be situated within 150–200 mm distance from blood vessels in order to maintain proper functions [28,29].”
BackgroundMicrofabricated immunoisolating biocapsules
Desai, T. A., Chu, W. H., Tu, J. K., Beattie, G. M., Hayek, A., & Ferrari, M. (1998) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19980105)57:1<118::aid-bit14>3.0.co;2-g · Cited by 195
Checa, S., & Prendergast, P. J. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9594-9 · Cited by 194
Enhanced Oxygen Supply Improves Islet Viability in a New Bioartificial Pancreas
Barkai, U., Weir, G. C., Colton, C. K., Ludwig, B., Bornstein, S. R., Brendel, M. D., Neufeld, T., Bremer, C., Leon, A., Evron, Y., et al. (2013) · Cell Transplantation · doi:10.3727/096368912x657341 · Cited by 193
Self-citationNanopore Technology for Biomedical Applications
Desai, T. A., Hansford, D. J., Kulinsky, L., Nashat, A. H., Rasi, G., Tu, J., Wang, Y., Zhang, M., & Ferrari, M. (1999) · Biomedical Microdevices · doi:10.1023/a:1009903215959 · Cited by 193
Degradable and injectable poly(aldehyde guluronate) hydrogels for bone tissue engineering
Lee, K. Y., Alsberg, E., & Mooney, D. J. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200108)56:2<228::aid-jbm1089>3.0.co;2-9 · Cited by 193
Device design and materials optimization of conformal coating for islets of Langerhans
Tomei, A. A., Manzoli, V., Fraker, C. A., Giraldo, J., Velluto, D., Najjar, M., Pileggi, A., Molano, R. D., Ricordi, C., Stabler, C. L., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1402216111 · Cited by 192
Vascularized and Innervated Skeletal Muscle Tissue Engineering
Gilbert‐Honick, J., & Grayson, W. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201900626 · Cited by 191
Release from alginate enhances the biological activity of vascular endothelial growth factor
Peters, M. C., Isenberg, B. C., Rowley, J. A., & Mooney, D. J. (1998) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856298x00389 · Cited by 190
Hosseinkhani, H., Hosseinkhani, M., Khademhosseini, A., Kobayashi, H., & Tabata, Y. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.003 · Cited by 188
“We demonstrate that a 3-”
Jabbarzadeh, E., Starnes, T., Khan, Y. M., Jiang, T., Wirtel, A. J., Deng, M., Lv, Q., Nair, L. S., Doty, S. B., & Laurencin, C. T. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0800069105 · Cited by 188
“Despite its critical role, blood vessel invasion from the host tissue is limited to a depth of several hundred micrometers from the surface of the implant (7, 8).”
BackgroundAdvances and Applications of Biodegradable Elastomers in Regenerative Medicine
Serrano, M. C., Chung, E. J., & Ameer, G. A. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200901040 · Cited by 185
Optimizing the success of cell transplantation therapy for stroke
Bliss, T. M., Andres, R. H., & Steinberg, G. K. (2010) · Neurobiology of Disease · doi:10.1016/j.nbd.2009.10.003 · Cited by 184
Tissue Engineering at the Micro-Scale
Bhatia, S. N., & Chen, C. S. (1999) · Biomedical Microdevices · doi:10.1023/a:1009949704750 · Cited by 177
Biocompatibility of nanoporous alumina membranes for immunoisolation
La Flamme, K. E., Popat, K. C., Leoni, L., Markiewicz, E., La Tempa, T. J., Roman, B. B., Grimes, C. A., & Desai, T. A. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.010 · Cited by 170
“The encapsulation of living metabolic cells within a semipermeable membrane has been studied over the last 30 years as a potential treatment for a number of diseases [1–4].”
BackgroundEngineering vascularised tissues in vitro
Institute for BioMedical Technology, D. O. T. R., Rivron, N., Liu, J., Rouwkema, J., de Boer, J., & van Blitterswijk, C. (2008) · European Cells and Materials · doi:10.22203/ecm.v015a03 · Cited by 168
Oxygen supply to encapsulated therapeutic cells
Colton, C. K. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.02.007 · Cited by 162
Self-citationOliver Cassell, C. S., Stefan Hofer, O. P., Morrison, W. A., & Knight, K. R. (2002) · British Journal of Plastic Surgery · doi:10.1054/bjps.2002.3950 · Cited by 161
Coronel, M. M., Liang, J.-P., Li, Y., & Stabler, C. L. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.04.017 · Cited by 85
Metadata
- Authors
- Colton, C.
- Venue
- Cell Transplantation
- Publisher
- Elsevier BV
- Published
- 1995-08
- Volume
- 4
- Issue
- 4
- Pages
- 415-436
- ISSN
- 0963-6897 (ISSN-L)
- OpenAlex
- W1976907471
- Cited by
- 586
- References
- 43
- FWCI
- 20.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.