The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms
Abstract
Aortic pulse wave velocity (PWV) and augmentation index are independent predictors of adverse cardiovascular events, including mortality. In hypertension and aging, central elastic arteries become stiffer, diastolic pressure decreases, and central systolic and pulse pressures are augmented due to increased PWV and early return of reflected waves to the heart from the periphery. Valuable information on arterial properties such as stiffness can be obtained from both central (aortic) and peripheral (radial artery) pressure waveforms, but absolute values of wave reflection amplitude and wasted left ventricular (LV) pressure energy can only be obtained from the central arterial pressure waveform. As the arterial system becomes stiffer, there is a marked increase in central systolic and pulse pressures and wasted LV energy, along with a decrease in pulse pressure amplification. The increase in aortic systolic and pulse pressures are due primarily to increases in PWV and wave reflection amplitude with a small increase in incident wave amplitude. In individuals with very stiff elastic arteries (eg, in older persons with isolated systolic hypertension), there is a decrease in diastolic pressure. These changes in pressure components increase LV afterload and myocardial oxygen demand and therefore cause an undesirable mismatch between ventricle emptying and arterial pulse wave transmission, which promotes ventricular hypertrophy. High systolic and pulse pressures resulting from advanced age or hypertension increase circumferential arterial wall stress, which likely causes breakdown of medial elastin and increases the possibility of local fatigue, endothelial damage and development of atherosclerosis. Vasodilator drugs may have little direct effect on large central elastic arteries, but at the same time, their effects on peripheral muscular arteries reduce wave reflection amplitude and markedly lower systolic and pulse pressures and ventricular afterload. These beneficial effects on central arterial pressure can occur with or without a reduction in cuff blood pressure (BP) and may explain the apparent "pressure-independent" effects of drugs such as angiotensin-converting enzyme inhibitors and angiotensin receptor blockers. Therefore, optimal treatment of high BP and its complications should include consideration of arterial stiffness, augmentation of aortic pressure, and LV wasted energy, all of which should be reduced to the lowest possible level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chobanian, A. V. (2003) · JAMA · doi:10.1001/jama.289.19.2560 · Cited by 25,386
(2000) · New England Journal of Medicine · doi:10.1056/nejm200001203420301 · Cited by 8,663
Levy, D., Garrison, R. J., Savage, D. D., Kannel, W. B., & Castelli, W. P. (1990) · New England Journal of Medicine · doi:10.1056/nejm199005313222203 · Cited by 5,699
Dahlöf, B., Devereux, R. B., Kjeldsen, S. E., Julius, S., Beevers, G., de Faire, U., Fyhrquist, F., Ibsen, H., Kristiansson, K., Lederballe-Pedersen, O., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)08089-3 · Cited by 5,407
Laurent, S., Boutouyrie, P., Asmar, R., Gautier, I., Laloux, B., Guize, L., Ducimetiere, P., & Benetos, A. (2001) · Hypertension · doi:10.1161/01.hyp.37.5.1236 · Cited by 3,856
Hemodynamic Patterns of Age-Related Changes in Blood Pressure: The Framingham Heart Study
Franklin, S. S., Gustin, W., Wong, N. D., Larson, M. G., Weber, M. A., Kannel, W. B., & Levy, D. (1997) · Circulation · doi:10.1161/01.cir.96.1.308 · Cited by 2,321
Impact of Aortic Stiffness on Survival in End-Stage Renal Disease
Blacher, J., Guerin, A. P., Pannier, B., Marchais, S. J., Safar, M. E., & London, G. M. (1999) · Circulation · doi:10.1161/01.cir.99.18.2434 · Cited by 2,138
Boutouyrie, P., Tropeano, A. I., Asmar, R., Gautier, I., Benetos, A., Lacolley, P., & Laurent, S. (2002) · Hypertension · doi:10.1161/hy0102.099031 · Cited by 1,745
Franklin, S. S., Larson, M. G., Khan, S. A., Wong, N. D., Leip, E. P., Kannel, W. B., & Levy, D. (2001) · Circulation · doi:10.1161/01.cir.103.9.1245 · Cited by 1,390
Safar, M. E., Levy, B. I., & Struijker-Boudier, H. (2003) · Circulation · doi:10.1161/01.cir.0000069826.36125.b4 · Cited by 1,197
Cited by
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
Flexible Sensing Electronics for Wearable/Attachable Health Monitoring
Wang, X., Liu, Z., & Zhang, T. (2017) · Small · doi:10.1002/smll.201602790 · Cited by 1,075
Dagdeviren, C., Su, Y., Joe, P., Yona, R., Liu, Y., Kim, Y.-S., Huang, Y., Damadoran, A. R., Xia, J., Martin, L. W., et al. (2014) · Nature Communications · doi:10.1038/ncomms5496 · Cited by 987
Park, J., Kim, M., Lee, Y., Lee, H. S., & Ko, H. (2015) · Science Advances · doi:10.1126/sciadv.1500661 · Cited by 939
Peng, X., Dong, K., Ye, C., Jiang, Y., Zhai, S., Cheng, R., Liu, D., Gao, X., Wang, J., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.aba9624 · Cited by 885
Wearable Pressure Sensors for Pulse Wave Monitoring
Meng, K., Xiao, X., Wei, W., Chen, G., Nashalian, A., Shen, S., Xiao, X., & Chen, J. (2022) · Advanced Materials · doi:10.1002/adma.202109357 · Cited by 878
The Endothelium and Its Role in Regulating Vascular Tone
Sandoo, A., Veldhuijzen van Zanten, J. J. C. S., Metsios, G. S., Carroll, D., & Kitas, G. D. (2010) · The Open Cardiovascular Medicine Journal · doi:10.2174/1874192401004010302 · Cited by 814
Guo, Y., Zhong, M., Fang, Z., Wan, P., & Yu, G. (2019) · Nano Letters · doi:10.1021/acs.nanolett.8b04514 · Cited by 741
Self‐Powered Real‐Time Arterial Pulse Monitoring Using Ultrathin Epidermal Piezoelectric Sensors
Park, D. Y., Joe, D. J., Kim, D. H., Park, H., Han, J. H., Jeong, C. K., Park, H., Park, J. G., Joung, B., & Lee, K. J. (2017) · Advanced Materials · doi:10.1002/adma.201702308 · Cited by 691
Zhang, F., Zang, Y., Huang, D., Di, C.-A., & Zhu, D. (2015) · Nature Communications · doi:10.1038/ncomms9356 · Cited by 668
A Sensitive and Biodegradable Pressure Sensor Array for Cardiovascular Monitoring
Boutry, C. M., Nguyen, A., Lawal, Q. O., Chortos, A., Rondeau‐Gagné, S., & Bao, Z. (2015) · Advanced Materials · doi:10.1002/adma.201502535 · Cited by 647
Bae, G. Y., Pak, S. W., Kim, D., Lee, G., Kim, D. H., Chung, Y., & Cho, K. (2016) · Advanced Materials · doi:10.1002/adma.201600408 · Cited by 646
Arterial Aging: Is It an Immutable Cardiovascular Risk Factor?
Najjar, S. S., Scuteri, A., & Lakatta, E. G. (2005) · Hypertension · doi:10.1161/01.hyp.0000177474.06749.98 · Cited by 640
Lee, H.-Y., & Oh, B.-H. (2010) · Circulation Journal · doi:10.1253/circj.cj-10-0910 · Cited by 620
Spontaneous Coronary Artery Dissection
Saw, J., Humphries, K., Aymong, E., Sedlak, T., Prakash, R., Starovoytov, A., & Mancini, G. B. J. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.06.053 · Cited by 619
Chen, Z., Wang, Z., Li, X., Lin, Y., Luo, N., Long, M., Zhao, N., & Xu, J.-B. (2017) · ACS Nano · doi:10.1021/acsnano.6b08027 · Cited by 605
Yang, J., Chen, J., Su, Y., Jing, Q., Li, Z., Yi, F., Wen, X., Wang, Z., & Wang, Z. L. (2015) · Advanced Materials · doi:10.1002/adma.201404794 · Cited by 595
Yang, J. C., Kim, J.-O., Oh, J., Kwon, S. Y., Sim, J. Y., Kim, D. W., Choi, H. B., & Park, S. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b03261 · Cited by 595
Wu, X., Han, Y., Zhang, X., Zhou, Z., & Lu, C. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201601995 · Cited by 583
High‐Stretchability, Ultralow‐Hysteresis ConductingPolymer Hydrogel Strain Sensors for Soft Machines
Shen, Z., Zhang, Z., Zhang, N., Li, J., Zhou, P., Hu, F., Rong, Y., Lu, B., & Gu, G. (2022) · Advanced Materials · doi:10.1002/adma.202203650 · Cited by 574
Carbonized Silk Nanofiber Membrane for Transparent and Sensitive Electronic Skin
Wang, Q., Jian, M., Wang, C., & Zhang, Y. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605657 · Cited by 549
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Chen, L. Y., Tee, B. C. K., Chortos, A. L., Schwartz, G., Tse, V., J. Lipomi, D., Wong, H. S. P., McConnell, M. V., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms6028 · Cited by 541
Lou, Z., Chen, S., Wang, L., Jiang, K., & Shen, G. (2016) · Nano Energy · doi:10.1016/j.nanoen.2016.02.053 · Cited by 533
Lee, Y., Park, J., Cho, S., Shin, Y.-E., Lee, H., Kim, J., Myoung, J., Cho, S., Kang, S., Baig, C., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b01805 · Cited by 528
Machine-knitted washable sensor array textile for precise epidermal physiological signal monitoring
Fan, W., He, Q., Meng, K., Tan, X., Zhou, Z., Zhang, G., Yang, J., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.aay2840 · Cited by 516
Kwon, D., Lee, T.-I., Shim, J., Ryu, S., Kim, M. S., Kim, S., Kim, T.-S., & Park, I. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b04225 · Cited by 516
Shi, J., Wang, L., Dai, Z., Zhao, L., Du, M., Li, H., & Fang, Y. (2018) · Small · doi:10.1002/smll.201800819 · Cited by 507
Si, Y., Wang, X., Yan, C., Yang, L., Yu, J., & Ding, B. (2016) · Advanced Materials · doi:10.1002/adma.201603143 · Cited by 503
Wang, T., Zhang, Y., Liu, Q., Cheng, W., Wang, X., Pan, L., Xu, B., & Xu, H. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201705551 · Cited by 494
Li, X., He, L., Li, Y., Chao, M., Li, M., Wan, P., & Zhang, L. (2021) · ACS Nano · doi:10.1021/acsnano.1c01751 · Cited by 473
Mimicking Human and Biological Skins for Multifunctional Skin Electronics
Lee, Y., Park, J., Choe, A., Cho, S., Kim, J., & Ko, H. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201904523 · Cited by 465
Highly Stretchy Black Gold E‐Skin Nanopatches as Highly Sensitive Wearable Biomedical Sensors
Gong, S., Lai, D. T. H., Su, B., Si, K. J., Ma, Z., Yap, L. W., Guo, P., & Cheng, W. (2015) · Advanced Electronic Materials · doi:10.1002/aelm.201400063 · Cited by 461
A Wireless Textile-Based Sensor System for Self-Powered Personalized Health Care
Meng, K., Zhao, S., Zhou, Y., Wu, Y., Zhang, S., He, Q., Wang, X., Zhou, Z., Fan, W., Tan, X., et al. (2020) · Matter · doi:10.1016/j.matt.2019.12.025 · Cited by 450
Yang, J., Luo, S., Zhou, X., Li, J., Fu, J., Yang, W., & Wei, D. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b02049 · Cited by 433
Lin, W., Wang, B., Peng, G., Shan, Y., Hu, H., & Yang, Z. (2021) · Advanced Science · doi:10.1002/advs.202002817 · Cited by 395
Chao, M., He, L., Gong, M., Li, N., Li, X., Peng, L., Shi, F., Zhang, L., & Wan, P. (2021) · ACS Nano · doi:10.1021/acsnano.1c00472 · Cited by 387
Organic field-effect transistor-based flexible sensors
Yuvaraja, S., Nawaz, A., Liu, Q., Dubal, D., Surya, S. G., Salama, K. N., & Sonar, P. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00811j · Cited by 386
Arterial stiffness: a brief review
Shirwany, N. A., & Zou, M.-H. (2010) · Acta Pharmacologica Sinica · doi:10.1038/aps.2010.123 · Cited by 385
Muscle Fibers Inspired High‐Performance Piezoelectric Textiles for Wearable Physiological Monitoring
Su, Y., Chen, C., Pan, H., Yang, Y., Chen, G., Zhao, X., Li, W., Gong, Q., Xie, G., Zhou, Y., et al. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202010962 · Cited by 385
Vascular wall extracellular matrix proteins and vascular diseases
Xu, J., & Shi, G.-P. (2014) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/j.bbadis.2014.07.008 · Cited by 381
Micropatterned Pyramidal Ionic Gels for Sensing Broad-Range Pressures with High Sensitivity
Cho, S. H., Lee, S. W., Yu, S., Kim, H., Chang, S., Kang, D., Hwang, I., Kang, H. S., Jeong, B., Kim, E. H., et al. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b00398 · Cited by 369
Is schizophrenia a syndrome of accelerated aging?
Kirkpatrick, B., Messias, E., Harvey, P. D., Fernandez-Egea, E., & Bowie, C. R. (2008) · Schizophrenia Bulletin · doi:10.1093/schbul/sbm140 · Cited by 335
A Wearable and Highly Sensitive Graphene Strain Sensor for Precise Home-Based Pulse Wave Monitoring
Yang, T., Jiang, X., Zhong, Y., Zhao, X., Lin, S., Li, J., Li, X., Xu, J., Li, Z., & Zhu, H. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00230 · Cited by 321
Chuengsamarn, S., Rattanamongkolgul, S., Phonrat, B., Tungtrongchitr, R., & Jirawatnotai, S. (2014) · The Journal of Nutritional Biochemistry · doi:10.1016/j.jnutbio.2013.09.013 · Cited by 316
Engineering Smart Composite Hydrogels for Wearable Disease Monitoring
Li, J., Ding, Q., Wang, H., Wu, Z., Gui, X., Li, C., Hu, N., Tao, K., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01079-5 · Cited by 304
Non-Invasive Vascular Function Tests: Their Pathophysiological Background and Clinical Application
Tomiyama, H., & Yamashina, A. (2010) · Circulation Journal · doi:10.1253/circj.cj-09-0534 · Cited by 300
Supercapacitive Iontronic Nanofabric Sensing
Li, R., Si, Y., Zhu, Z., Guo, Y., Zhang, Y., Pan, N., Sun, G., & Pan, T. (2017) · Advanced Materials · doi:10.1002/adma.201700253 · Cited by 296
Cutaneous Ionogel Mechanoreceptors for Soft Machines, Physiological Sensing, and Amputee Prostheses
Shen, Z., Zhu, X., Majidi, C., & Gu, G. (2021) · Advanced Materials · doi:10.1002/adma.202102069 · Cited by 291
He, J., Xiao, P., Lu, W., Shi, J., Zhang, L., Liang, Y., Pan, C., Kuo, S.-W., & Chen, T. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.02.036 · Cited by 291
Drager, L. F., Bortolotto, L. A., Figueiredo, A. C., Silva, B. C., Krieger, E. M., & Lorenzi-Filho, G. (2007) · Chest · doi:10.1378/chest.06-2703 · Cited by 284
Zhan, Z., Lin, R., Tran, V.-T., An, J., Wei, Y., Du, H., Tran, T., & Lu, W. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b10820 · Cited by 278
Tomimatsu, T., Mimura, K., Matsuzaki, S., Endo, M., Kumasawa, K., & Kimura, T. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20174246 · Cited by 277
Wang, Y., Lee, S., Yokota, T., Wang, H., Jiang, Z., Wang, J., Koizumi, M., & Someya, T. (2020) · Science Advances · doi:10.1126/sciadv.abb7043 · Cited by 277
A Tough and Self-Powered Hydrogel for Artificial Skin
Fu, R., Tu, L., Zhou, Y., Fan, L., Zhang, F., Wang, Z., Xing, J., Chen, D., Deng, C., Tan, G., et al. (2019) · Chemistry of Materials · doi:10.1021/acs.chemmater.9b04041 · Cited by 259
Laminated Object Manufacturing of 3D‐Printed Laser‐Induced Graphene Foams
Luong, D. X., Subramanian, A. K., Silva, G. A. L., Yoon, J., Cofer, S., Yang, K., Owuor, P. S., Wang, T., Wang, Z., Lou, J., et al. (2018) · Advanced Materials · doi:10.1002/adma.201707416 · Cited by 257
Radial augmentation index: A useful and easily obtainable parameter for vascular aging
KOHARA, K., TABARA, Y., OSHIUMI, A., MIYAWAKI, Y., KOBAYASHI, T., & MIKI, T. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2004.10.010 · Cited by 255
Huang, Y.-C., Liu, Y., Ma, C., Cheng, H.-C., He, Q., Wu, H., Wang, C., Lin, C.-Y., Huang, Y., & Duan, X. (2020) · Nature Electronics · doi:10.1038/s41928-019-0356-5 · Cited by 233
Plasma aldosterone is independently associated with the metabolic syndrome
Bochud, M., Nussberger, J., Bovet, P., Maillard, M. R., Elston, R. C., Paccaud, F., Shamlaye, C., & Burnier, M. (2006) · Hypertension · doi:10.1161/01.hyp.0000231338.41548.fc · Cited by 226
Park, S.-H., Lee, H. B., Yeon, S. M., Park, J., & Lee, N. K. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b07833 · Cited by 215
Ultrasensitive skin-like wearable optical sensors based on glass micro/nanofibers
Zhang, L., Pan, J., Zhang, Z., Wu, H., Yao, N., Cai, D., Xu, Y., Zhang, J., Sun, G., Wang, L., et al. (2020) · Opto-Electronic Advances · doi:10.29026/oea.2020.190022 · Cited by 186
Wang, Z., Guo, S., Li, H., Wang, B., Sun, Y., Xu, Z., Chen, X., Wu, K., Zhang, X., Xing, F., et al. (2019) · Advanced Materials · doi:10.1002/adma.201805630 · Cited by 185
Stretchable and Highly Sensitive Optical Strain Sensors for Human-Activity Monitoring and Healthcare
Guo, J., Zhou, B., Zong, R., Pan, L., Li, X., Yu, X., Yang, C., Kong, L., & Dai, Q. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b09815 · Cited by 170
Vascular function and morphology in rheumatoid arthritis: a systematic review
Sandoo, A., Veldhuijzen van Zanten, J. J. C. S., Metsios, G. S., Carroll, D., & Kitas, G. D. (2011) · Rheumatology · doi:10.1093/rheumatology/ker275 · Cited by 146
von Wowern, E., Östling, G., Nilsson, P. M., & Olofsson, P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0135659 · Cited by 134
“AIX is influenced by both large artery stiffness and properties in the PW-reflecting peripheral arterial tree [5 – 7] and is associated with cardiovascular risk, although it is less established than the PWV as a risk factor for cardiovascular morbidity [8 – 10].”
Zheng, S., Wu, X., Huang, Y., Xu, Z., Yang, W., Liu, Z., Huang, S., Xie, B., & Yang, M. (2019) · Composites Part A: Applied Science and Manufacturing · doi:10.1016/j.compositesa.2019.04.014 · Cited by 109
Hashimoto, J., Nichols, W. W., O'Rourke, M. F., & Imai, Y. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2007.49 · Cited by 111
Self-citationNing, R., Li, Y., Du, Z., Li, T., Sun, Q., Lin, L., Xu, Q., Duan, J., & Sun, Z. (2021) · Redox Biology · doi:10.1016/j.redox.2021.102113 · Cited by 96
“myocardial hypoperfusion and may cause myocardial ischemia and heart failure [40].”
Yu, L., Yi, Y., Yao, T., Song, Y., Chen, Y., Li, Q., Xia, Z., Wei, N., Tian, Z., Nie, B., et al. (2019) · Nano Research · doi:10.1007/s12274-018-2219-1 · Cited by 84
Hsiu, H., Hsu, C.-L., & Wu, T.-L. (2011) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411910396288 · Cited by 46
Figueroa, A., Arjmandi, B. H., Wong, A., Sanchez-Gonzalez, M. A., Simonavice, E., & Daggy, B. (2013) · Menopause · doi:10.1097/gme.0b013e3182831ee4 · Cited by 45
Krasińska, B., Miazga, A., Cofta, S., Szczepaniak-Chicheł, L., Trafas, T., Krasiński, Z., Pawlaczyk-Gabriel, K., & Tykarski, A. (2016) · Polish Archives of Internal Medicine · doi:10.20452/pamw.3410 · Cited by 43
Egan, B. M., Laken, M. A., Donovan, J. L., & Woolson, R. F. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.151522 · Cited by 38
Huisman, H. W., Schutte, A. E., Schutte, R., van Rooyen, J. M., Fourie, C. M. T., Mels, C. M. C., Smith, W., Malan, N. T., & Malan, L. (2013) · American Journal of Hypertension · doi:10.1093/ajh/hps007 · Cited by 32
Mahendru, A. A., Everett, T. R., McEniery, C. M., Wilkinson, I. B., & Lees, C. C. (2013) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2012.733774 · Cited by 19
“Central (aortic) systolic (SBP), mean arterial pressure (MAP), aortic AIx were determined using the integrated software [27,28].”
MethodHeart Rate After Cardiac Transplantation—Lessons From the Tortoise and the Shrew
Critchley, W. R., Yonan, N., Shaw, S. M., & Fildes, J. E. (2013) · Transplantation Journal · doi:10.1097/tp.0b013e31826bc42a · Cited by 13
Metadata
- Authors
- NICHOLS, W.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-01
- Volume
- 18
- Issue
- 1 Pt 2
- Pages
- 3-10
- ISSN
- 0895-7061 (ISSN-L)
- OpenAlex
- W2066442598
- Cited by
- 1,001
- References
- 61
- FWCI
- 22.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.