The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
A review of machine learning techniques in photoplethysmography for the non-invasive cuff-less measurement of blood pressure
Open accessAbstract
Hypertension or high blood pressure is a leading cause of death throughout the world and a critical factor for increasing the risk of serious diseases, including cardiovascular diseases such as stroke and heart failure. Blood pressure is a primary vital sign that must be monitored regularly for the early detection, prevention and treatment of cardiovascular diseases. Traditional blood pressure measurement techniques are either invasive or cuff-based, which are impractical, intermittent, and uncomfortable for patients. Over the past few decades, several indirect approaches using photoplethysmogram (PPG) have been investigated, namely, pulse transit time, pulse wave velocity, pulse arrival time and pulse wave analysis, in an effort to utilise PPG for estimating blood pressure. Recent advancements in signal processing techniques, including machine learning and artificial intelligence, have also opened up exciting new horizons for PPG-based cuff less and continuous monitoring of blood pressure. Such a device will have a significant and transformative impact in monitoring patients’ vital signs, especially those at risk of cardiovascular disease. This paper provides a comprehensive review for non-invasive cuff-less blood pressure estimation using the PPG approach along with their challenges and limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Lim, S. S., Vos, T., Flaxman, A. D., Danaei, G., Shibuya, K., Adair-Rohani, H., AlMazroa, M. A., Amann, M., Anderson, H. R., Andrews, K. G., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61766-8 · Cited by 11,805
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Human blood pressure determination by sphygmomanometry.
Perloff, D., Grim, C., Flack, J., Frohlich, E. D., Hill, M., McDonald, M., & Morgenstern, B. Z. (1993) · Circulation · doi:10.1161/01.cir.88.5.2460 · Cited by 1,591
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
2015 IEEE International Conference on Communications (ICC)
(2015) · doi:10.1109/icc31322.2015 · Cited by 909
(2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2417514 · Cited by 706
Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621
Elastin in Large Artery Stiffness and Hypertension
Wagenseil, J. E., & Mecham, R. P. (2012) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-012-9349-8 · Cited by 462
Chen, W., Kobayashi, T., Ichikawa, S., Takeuchi, Y., & Togawa, T. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345755 · Cited by 425
2005 IEEE Engineering in Medicine and Biology 27th Annual Conference
(2005) · doi:10.1109/embc9043.2006 · Cited by 423
Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2015) · 2015 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2015.7168806 · Cited by 333
2014 IEEE International Symposium on Circuits and Systems (ISCAS)
(2014) · doi:10.1109/iscas31212.2014 · Cited by 299
Pulse Transit Time as an Indicator of Arterial Blood Pressure
Geddes, L. A., Voelz, M. H., Babbs, C. F., Bourland, J. D., & Tacker, W. A. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb01545.x · Cited by 293
A Neural Network-based method for continuous blood pressure estimation from a PPG signal
Kurylyak, Y., Lamonaca, F., & Grimaldi, D. (2013) · 2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) · doi:10.1109/i2mtc.2013.6555424 · Cited by 291
Optical blood pressure estimation with photoplethysmography and FFT-based neural networks
Xing, X., & Sun, M. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003007 · Cited by 265
Theory of the oscillometric maximum and the systolic and diastolic detection ratios
Drzewiecki, G., Hood, R., & Apple, H. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368225 · Cited by 251
Teng, X. F., & Zhang, Y. T. (2004) · Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439) · doi:10.1109/iembs.2003.1280811 · Cited by 237
Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226
The difference in pulse transit time to the toe and finger measured by photoplethysmography
Nitzan, M., Khanokh, B., & Slovik, Y. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/1/308 · Cited by 218
Long-term blood pressure prediction with deep recurrent neural networks
Su, P., Ding, X.-R., Zhang, Y.-T., Liu, J., Miao, F., & Zhao, N. (2018) · 2018 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI) · doi:10.1109/bhi.2018.8333434 · Cited by 203
Wong, M. Y.-M., Poon, C. C.-Y., & Zhang, Y.-T. (2009) · Cardiovascular Engineering · doi:10.1007/s10558-009-9070-7 · Cited by 191
Tanveer, M. S., & Hasan, M. K. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.028 · Cited by 188
Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes
Allen, J., & Murray, A. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001478 · Cited by 179
A Novel Continuous Blood Pressure Estimation Approach Based on Data Mining Techniques
Miao, F., Fu, N., Zhang, Y.-T., Ding, X.-R., Hong, X., He, Q., & Li, Y. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2691715 · Cited by 174
Khalid, S. G., Zhang, J., Chen, F., & Zheng, D. (2018) · Journal of Healthcare Engineering · doi:10.1155/2018/1548647 · Cited by 171
38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
(2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2512420 · Cited by 168
Kim, C., Carek, A. M., Mukkamala, R., Inan, O. T., & Hahn, J. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2440291 · Cited by 161
Cuffless Blood Pressure Estimation Based on Photoplethysmography Signal and Its Second Derivative
Liu, M., Po, L.-M., & Fu, H. (2017) · International Journal of Computer Theory and Engineering · doi:10.7763/ijcte.2017.v9.1138 · Cited by 160
4th Kuala Lumpur International Conference on Biomedical Engineering 2008
Magjarevic, R., Wan Abas, W. A. B., Ting, H.-N., Nagel, J. H., Ibrahim, F., Abu Osman, N. A., Abdul Rahman, H. S., & 2008, B. (2008) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-69139-6 · Cited by 146
Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure
Zhang, G., Gao, M., Xu, D. Z., Olivier, N. B., & Mukkamala, R. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00980.2011 · Cited by 140
Noninvasive cuffless blood pressure estimation using pulse transit time and Hilbert–Huang transform
Choi, Y., Zhang, Q., & Ko, S. (2012) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2012.09.005 · Cited by 139
Ruiz‐Rodríguez, J. C., Ruiz‐Sanmartín, A., Ribas, V. J., Caballero, J., García‐Roche, A., Riera, J., Nuvials, X., NADAL, M. D., Solà-Morales, O., Serra, J., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-013-2964-2 · Cited by 138
McCombie, D. B., Reisner, A. T., & Asada, H. H. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260590 · Cited by 118
Chen, Y., Wen, C., Tao, G., Bi, M., & Li, G. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9759-1 · Cited by 115
Wang, L., Zhou, W., Xing, Y., & Zhou, X. (2018) · Journal of Healthcare Engineering · doi:10.1155/2018/7804243 · Cited by 109
A Non-Invasive Continuous Blood Pressure Estimation Approach Based on Machine Learning
Chen, S., Ji, Z., Wu, H., & Xu, Y. (2019) · Sensors · doi:10.3390/s19112585 · Cited by 103
Cuff-less PPG based continuous blood pressure monitoring — A smartphone based approach
Gaurav, A., Maheedhar, M., Tiwari, V. N., & Narayanan, R. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7590775 · Cited by 100
Gao, M., Olivier, N. B., & Mukkamala, R. (2016) · Physiological Reports · doi:10.14814/phy2.12768 · Cited by 86
Ma, T., & Zhang, Y. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616585 · Cited by 84
InstaBP: Cuff-less Blood Pressure Monitoring on Smartphone using Single PPG Sensor
Dey, J., Gaurav, A., & Tiwari, V. N. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513189 · Cited by 79
Estimating blood pressure using Windkessel model on photoplethysmogram
Choudhury, A. D., Banerjee, R., Sinha, A., & Kundu, S. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944640 · Cited by 78
Duan, K., Qian, Z., Atef, M., & Wang, G. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592189 · Cited by 62
Data-driven estimation of blood pressure using photoplethysmographic signals
Gao, S. C., Wittek, P., Zhao, L., & Jiang, W. J. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7590814 · Cited by 62
Chen, Y., Wen, C., Tao, G., & Bi, M. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0467-2 · Cited by 61
Building Continuous Arterial Blood Pressure Prediction Models Using Recurrent Networks
Sideris, C., Kalantarian, H., Nemati, E., & Sarrafzadeh, M. (2016) · IEEE International Conference on Smart Computing · doi:10.1109/smartcomp.2016.7501681 · Cited by 58
PPG-Based Systolic Blood Pressure Estimation Method Using PLS and Level-Crossing Feature
Fujita, D., Suzuki, A., & Ryu, K. (2019) · Applied Sciences · doi:10.3390/app9020304 · Cited by 46
Features Extraction for Cuffless Blood Pressure Estimation by Autoencoder from Photoplethysmography
Shimazaki, S., Bhuiyan, M. S., Kawanaka, H., & Oguri, K. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512829 · Cited by 44
Blood pressure estimation from photoplethysmogram using latent parameters
Datta, S., Banerjee, R., Choudhury, A. D., Sinha, A., & Pal, A. (2016) · International Conference on Communications · doi:10.1109/icc.2016.7511599 · Cited by 40
Forouzanfar, M., Ahmad, S., Batkin, I., Dajani, H. R., Groza, V. Z., & Bolić, M. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2412000 · Cited by 34
Suzuki, S., & Oguri, K. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5332505 · Cited by 31
Blood Pressure Assessment with Differential Pulse Transit Time and Deep Learning: A Proof of Concept
Ripoll, V. R., & Vellido, A. (2018) · Kidney Diseases · doi:10.1159/000493478 · Cited by 23
Cuffless and continuous blood pressure estimation based on multiple regression analysis
Shen, Z., Miao, F., Meng, Q., & Li, Y. (2015) · International Conference on Information Science and Technology · doi:10.1109/icist.2015.7288952 · Cited by 20
Measuring Blood Pressure Using a Photoplethysmography Approach
Hassan, M. K. A., Mashor, . Y., Nasir, N. F. M., & Mohamed, M. S. (2008) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-69139-6_148 · Cited by 13
Cited by
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
Self-citationCuffless Blood Pressure Measurement
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-014644 · Cited by 180
A Review of Wearable Multi-Wavelength Photoplethysmography
Ray, D., Collins, T., Woolley, S., & Ponnapalli, P. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3121476 · Cited by 155
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
Self-citationAjmal, Boonya-Ananta, T., Rodriguez, A. J., Du Le, V. N., & Ramella-Roman, J. C. (2021) · Biomedical Optics Express · doi:10.1364/boe.439893 · Cited by 79
Metadata
- Authors
- El-Hajj, C., & Kyriacou, P. A.
- Venue
- Biomedical Signal Processing and Control
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 58
- Pages
- 101870
- ISSN
- 1746-8094 (ISSN-L)
- OpenAlex
- W3006649679
- Cited by
- 294
- References
- 59
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.