The DOI matches its Crossref record; 135 of the 135 references it cites were found in a registry or an index.
Multi-parametric neuroimaging reproducibility: A 3-T resource study
Open accessAbstract
Modern MRI image processing methods have yielded quantitative, morphometric, functional, and structural assessments of the human brain. These analyses typically exploit carefully optimized protocols for specific imaging targets. Algorithm investigators have several excellent public data resources to use to test, develop, and optimize their methods. Recently, there has been an increasing focus on combining MRI protocols in multi-parametric studies. Notably, these have included innovative approaches for fusing connectivity inferences with functional and/or anatomical characterizations. Yet, validation of the reproducibility of these interesting and novel methods has been severely hampered by the limited availability of appropriate multi-parametric data. We present an imaging protocol optimized to include state-of-the-art assessment of brain function, structure, micro-architecture, and quantitative parameters within a clinically feasible 60 minute protocol on a 3T MRI scanner. We present scan-rescan reproducibility of these imaging contrasts based on 21 healthy volunteers (11 M/10 F, 22–61 y/o). The cortical gray matter, cortical white matter, ventricular cerebrospinal fluid, thalamus, putamen, caudate, cerebellar gray matter, cerebellar white matter, and brainstem were identified with mean volume-wise reproducibility of 3.5%. We tabulate the mean intensity, variability and reproducibility of each contrast in a region of interest approach, which is essential for prospective study planning and retrospective power analysis considerations. Anatomy was highly consistent on structural acquisition (~1–5% variability), while variation on diffusion and several other quantitative scans was higher (~<10%). Some sequences are particularly variable in specific structures (ASL exhibited variation of 28% in the cerebral white matter) or in thin structures (quantitative T2 varied by up to 73% in the caudate) due, in large part, to variability in automated ROI placement. The richness of the joint distribution of intensities across imaging methods can be best assessed within the context of a particular analysis approach as opposed to a summary table. As such, all imaging data and analysis routines have been made publicly and freely available. This effort provides the neuroimaging community with a resource for optimization of algorithms that exploit the diversity of modern MRI modalities. Additionally, it establishes a baseline for continuing development and optimization of multi-parametric imaging protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
A default mode of brain function
Raichle, M. E., MacLeod, A. M., Snyder, A. Z., Powers, W. J., Gusnard, D. A., & Shulman, G. L. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.2.676 · Cited by 12,190
Co-Planar Stereotaxic Atlas of the Human Brain
Talairach, J., & Tournoux, P. (1988) · Medical Entomology and Zoology · Cited by 11,798
Functional connectivity in the motor cortex of resting human brain using echo‐planar mri
Biswal, B., Zerrin Yetkin, F., Haughton, V. M., & Hyde, J. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340409 · Cited by 9,812
The human brain is intrinsically organized into dynamic, anticorrelated functional networks
Fox, M. D., Snyder, A. Z., Vincent, J. L., Corbetta, M., Van Essen, D. C., & Raichle, M. E. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504136102 · Cited by 8,553
Co-planar stereotaxic atlas of the human brain
Laitinen, L. (1989) · Clinical Neurology and Neurosurgery · doi:10.1016/0303-8467(89)90128-5 · Cited by 7,565
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507 · cited 1×
“• Resting state fMRI analysis includes slice time correction, realignment, and spatial normalization preprocessing steps (Ashburner and Friston, 2005) followed by advanced modeling to reduce physiological noise (Behzadi et al., 2007).”
Dissociable intrinsic connectivity networks for salience processing and executive control
Seeley, W. W., Menon, V., Schatzberg, A. F., Keller, J., Glover, G. H., Kenna, H., Reiss, A. L., & Greicius, M. D. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.5587-06.2007 · Cited by 7,426
Forming inferences about some intraclass correlation coefficients.
McGraw, K. O., & Wong, S. P. (1996) · Psychological Methods · doi:10.1037/1082-989x.1.1.30 · Cited by 6,903
Functional connectivity in the resting brain: a network analysis of the default mode hypothesis
Greicius, M. D., Krasnow, B., Reiss, A. L., & Menon, V. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0135058100 · Cited by 6,358 · cited 1×
“In recent years, BOLD fMRI has been widely used to evaluate FC revealing several neurobiologically relevant intrinsically connected networks (ICNs) (Greicius et al., 2003; Raichle et al., 2001; Seeley et al., 2007; Vincent et al., 2004).”
MethodSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
Correspondence of the brain's functional architecture during activation and rest
Smith, S. M., Fox, P. T., Miller, K. L., Glahn, D. C., Fox, P. M., Mackay, C. E., Filippini, N., Watkins, K. E., Toro, R., Laird, A. R., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0905267106 · Cited by 5,150
Self-citationThe basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
A component based noise correction method (CompCor) for BOLD and perfusion based fMRI
Behzadi, Y., Restom, K., Liau, J., & Liu, T. T. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.04.042 · Cited by 4,502
The Alzheimer’s disease neuroimaging initiative (ADNI): MRI methods
Jack, C. R., Bernstein, M. A., Fox, N. C., Thompson, P., Alexander, G., Harvey, D., Borowski, B., Britson, P. J., L. Whitwell, J., Ward, C., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21049 · Cited by 4,347
Estimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Andersson, J. L. R., Skare, S., & Ashburner, J. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00336-7 · Cited by 3,469
The Human Connectome: A Structural Description of the Human Brain
Sporns, O., Tononi, G., & Kötter, R. (2005) · PLoS Computational Biology · doi:10.1371/journal.pcbi.0010042 · Cited by 3,260 · cited 1×
“, the “connectome” (Sporns et al., 2005)).”
A method for making group inferences from functional MRI data using independent component analysis
Calhoun, V. D., Adali, T., Pearlson, G. D., & Pekar, J. J. (2001) · Human Brain Mapping · doi:10.1002/hbm.1048 · Cited by 2,994
Self-citationMagnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Murphy, K., Birn, R. M., Handwerker, D. A., Jones, T. B., & Bandettini, P. A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.036 · Cited by 2,387
Neurodegenerative Diseases Target Large-Scale Human Brain Networks
Seeley, W. W., Crawford, R. K., Zhou, J., Miller, B. L., & Greicius, M. D. (2009) · Neuron · doi:10.1016/j.neuron.2009.03.024 · Cited by 2,350
Greicius, M. D., Flores, B. H., Menon, V., Glover, G. H., Solvason, H. B., Kenna, H., Reiss, A. L., & Schatzberg, A. F. (2007) · Biological Psychiatry · doi:10.1016/j.biopsych.2006.09.020 · Cited by 2,214
Marcus, D. S., Wang, T. H., Parker, J., Csernansky, J. G., Morris, J. C., & Buckner, R. L. (2007) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2007.19.9.1498 · Cited by 2,163
Fiber tracking: principles and strategies – a technical review
Mori, S., & van Zijl, P. C. M. (2002) · NMR in Biomedicine · doi:10.1002/nbm.781 · Cited by 2,024
Self-citationIntrinsic functional architecture in the anaesthetized monkey brain
Vincent, J. L., Patel, G. H., Fox, M. D., Snyder, A. Z., Baker, J. T., Van Essen, D. C., Zempel, J. M., Snyder, L. H., Corbetta, M., & Raichle, M. E. (2007) · Nature · doi:10.1038/nature05758 · Cited by 1,786
Tracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
The Alzheimer's Disease Neuroimaging Initiative
Mueller, S. G., Weiner, M. W., Thal, L. J., Petersen, R. C., Jack, C., Jagust, W., Trojanowski, J. Q., Toga, A. W., & Beckett, L. (2005) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2005.09.008 · Cited by 1,525
Østergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
Wolff, S. D., & Balaban, R. S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100113 · Cited by 1,482
Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical review
Basser, P. J., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.783 · Cited by 1,478
Frequencies contributing to functional connectivity in the cerebral cortex in "resting-state" data.
Cordes, D., Haughton, V. M., Arfanakis, K., Carew, J. D., Turski, P. A., Moritz, C. H., Quigley, M., & Meyerand, M. E. (2001) · PubMed Central · Cited by 1,402
Competition between functional brain networks mediates behavioral variability
Kelly, A. M. C., Uddin, L. Q., Biswal, B. B., Castellanos, F. X., & Milham, M. P. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.008 · Cited by 1,287
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE)
Mugler, J. P., & Brookeman, J. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150117 · Cited by 1,265
Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system.
Moseley, M. E., Cohen, Y., Kucharczyk, J., Mintorovitch, J., Asgari, H. S., Wendland, M. F., Tsuruda, J., & Norman, D. (1990) · Radiology · doi:10.1148/radiology.176.2.2367658 · Cited by 1,133
Yarnykh, V. L. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21120 · Cited by 1,026
Magnetization transfer in MRI: a review
Henkelman, R. M., Stanisz, G. J., & Graham, S. J. (2001) · NMR in Biomedicine · doi:10.1002/nbm.683 · Cited by 921
The Resting Brain: Unconstrained yet Reliable
Shehzad, Z., Kelly, A. M. C., Reiss, P. T., Gee, D. G., Gotimer, K., Uddin, L. Q., Lee, S. H., Margulies, D. S., Roy, A. K., Biswal, B. B., et al. (2009) · Cerebral Cortex · doi:10.1093/cercor/bhn256 · Cited by 908
Østergaard, L., Sorensen, A. G., Kwong, K. K., Weisskoff, R. M., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360511 · Cited by 810
Magnetization transfer ratio and myelin in postmortem multiple sclerosis brain
Schmierer, K., Scaravilli, F., Altmann, D. R., Barker, G. J., & Miller, D. H. (2004) · Annals of Neurology · doi:10.1002/ana.20202 · Cited by 776
Edelman, R. R., Siewert, B., Darby, D. G., Thangaraj, V, Nobre, A. C., Mesulam, M. M., & Warach, S. (1994) · Radiology · doi:10.1148/radiology.192.2.8029425 · Cited by 700
Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
Lu, H., Clingman, C., Golay, X., & van Zijl, P. C. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20178 · Cited by 685
Self-citationMarcus, D. S., Fotenos, A. F., Csernansky, J. G., Morris, J. C., & Buckner, R. L. (2010) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2009.21407 · Cited by 631
Jovicich, J., Czanner, S., Han, X., Salat, D., van der Kouwe, A., Quinn, B., Pacheco, J., Albert, M., Killiany, R., & Blacker, D. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.010 · Cited by 559
van de Ven, V. G., Formisano, E., Prvulovic, D., Roeder, C. H., & Linden, D. E. J. (2004) · Human Brain Mapping · doi:10.1002/hbm.20022 · Cited by 541
Persistent default‐mode network connectivity during light sedation
Greicius, M. D., Kiviniemi, V., Tervonen, O., Vainionpää, V., Alahuhta, S., Reiss, A. L., & Menon, V. (2008) · Human Brain Mapping · doi:10.1002/hbm.20537 · Cited by 519
Medical Image Processing, Analysis and Visualization in clinical research
McAuliffe, M. J., Lalonde, F. M., McGarry, D., Gandler, W., Csaky, K., & Trus, B. L. (2002) · Proceedings 14th IEEE Symposium on Computer-Based Medical Systems. CBMS 2001 · doi:10.1109/cbms.2001.941749 · Cited by 512
Molecular diffusion, tissue microdynamics and microstructure
Bihan, D. L. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080711 · Cited by 497
Derdeyn, C. P., Videen, T. O., Yundt, K. D., Fritsch, S. M., Carpenter, D. A., Grubb, R. L., & Powers, W. J. (2002) · Brain · doi:10.1093/brain/awf047 · Cited by 490
Chalela, J. A., Alsop, D. C., Gonzalez-Atavales, J. B., Maldjian, J. A., Kasner, S. E., & Detre, J. A. (2000) · Stroke · doi:10.1161/01.str.31.3.680 · Cited by 481
Applications of diffusion‐weighted and diffusion tensor MRI to white matter diseases – a review
Horsfield, M. A., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.787 · Cited by 468
Wu, W., Fernández‐Seara, M., Detre, J. A., Wehrli, F. W., & Wang, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21403 · Cited by 465
Functional magnetic resonance imaging based on changes in vascular space occupancy
Lu, H., Golay, X., Pekar, J. J., & van Zijl, P. C. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10519 · Cited by 463
Self-citationSpatially independent activity patterns in functional MRI data during the Stroop color-naming task
McKeown, M. J., Jung, T.-P., Makeig, S., Brown, G., Kindermann, S. S., Lee, T.-W., & Sejnowski, T. J. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.3.803 · Cited by 461
Cortical network functional connectivity in the descent to sleep
Larson-Prior, L. J., Zempel, J. M., Nolan, T. S., Prior, F. W., Snyder, A. Z., & Raichle, M. E. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0900924106 · Cited by 450
The role of diffusion tensor imaging in the evaluation of ischemic brain injury – a review
Sotak, C. H. (2002) · NMR in Biomedicine · doi:10.1002/nbm.786 · Cited by 433
Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI
Sled, J. G., & Pike, G. B. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1278 · Cited by 419
Water diffusion and acute stroke
van Gelderen, P., de Vleeschouwer, M. H. M., DesPres, D., Pekar, J., van Zijl, P. C. M., & Moonen, C. T. W. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310209 · Cited by 410
Self-citationBoly, M., Phillips, C., Tshibanda, L., Vanhaudenhuyse, A., Schabus, M., Dang‐Vu, T. T., Moonen, G., Hustinx, R., Maquet, P., & Laureys, S. (2008) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1417.015 · Cited by 390
In vivo three-dimensional reconstruction of rat brain axonal projections by diffusion tensor imaging
Xue, R., van Zijl, P. C. M., Crain, B. J., Solaiyappan, M., & Mori, S. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1123::aid-mrm17>3.0.co;2-h · Cited by 386
Self-citationCerebral Perfusion CT: Technique and Clinical Applications
Hoeffner, E. G., Case, I., Jain, R., Gujar, S. K., Shah, G. V., Deveikis, J. P., Carlos, R. C., Thompson, B. G., Harrigan, M. R., & Mukherji, S. K. (2004) · Radiology · doi:10.1148/radiol.2313021488 · Cited by 384
Imaging of the active B1 field in vivo
Stollberger, R., & Wach, P. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350217 · Cited by 357
Busse, R. F., Hariharan, H., Vu, A., & Brittain, J. H. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20863 · Cited by 335
Use of Fluid Attenuated Inversion Recovery (FLAIR) Pulse Sequences in MRI of the Brain
Hajnal, J. V., Bryant, D. J., Kasuboski, L., Pattany, P. M., Coene, B. D., Lewis, P. D., Pennock, J. M., Oatridge, A., Young, I. R., & Bydder, G. M. (1992) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199211000-00001 · Cited by 334
Routine clinical brain MRI sequences for use at 3.0 Tesla
Lu, H., Nagae‐Poetscher, L. M., Golay, X., Lin, D., Pomper, M., & van Zijl, P. C. M. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20356 · Cited by 327
Self-citationMapping of the Radiofrequency Field
Insko, E. K., & Bolinger, L. (1993) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1993.1133 · Cited by 323
Neuropsychiatric applications of DTI – a review
Lim, K. O., & Helpern, J. A. (2002) · NMR in Biomedicine · doi:10.1002/nbm.789 · Cited by 225
Correction of off resonance‐related distortion in echo‐planar imaging using EPI‐based field maps
Reber, P. J., Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390223 · Cited by 223
Schneider, E., & Glover, G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180208 · Cited by 221
An Evaluation of the Use of Magnetic Field Maps to Undistort Echo-Planar Images
Cusack, R., Brett, M., & Osswald, K. (2003) · NeuroImage · doi:10.1006/nimg.2002.1281 · Cited by 219
Can arterial spin labeling detect white matter perfusion signal?
van Osch, M. J. P., Teeuwisse, W. M., van Walderveen, M. A. A., Hendrikse, J., Kies, D. A., & van Buchem, M. A. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22002 · Cited by 204
Quantitative Interpretation of Magnetization Transfer in Spoiled Gradient Echo MRI Sequences
Sled, J. G., & Pike, G. B. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.2000.2059 · Cited by 202
Kastrup, O., Wanke, I., & Maschke, M. (2005) · NeuroRX · doi:10.1602/neurorx.2.2.324 · Cited by 186
Absolute Quantitation of Diffusion Constants in Human Stroke
Uluğ, A. M., Beauchamp, N., Bryan, R. N., & van Zijl, P. C. M. (1997) · Stroke · doi:10.1161/01.str.28.3.483 · Cited by 180
Self-citationWeiskopf, N., Hutton, C., Josephs, O., Turner, R., & Deichmann, R. (2007) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-006-0067-6 · Cited by 177
From the diffusion coefficient to the diffusion tensor
Le Bihan, D., & van Zijl, P. (2002) · NMR in Biomedicine · doi:10.1002/nbm.798 · Cited by 167
Self-citationImaging of White Matter Lesions
Barkhof, F., & Scheltens, P. (2002) · Cerebrovascular Diseases · doi:10.1159/000049146 · Cited by 161
Theoretical and experimental investigation of the VASO contrast mechanism
Donahue, M. J., Lu, H., Jones, C. K., Edden, R. A. E., Pekar, J. J., & van Zijl, P. C. M. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21072 · Cited by 154
Self-citationMcKeown, M. J. (1998) · Medical Entomology and Zoology · Cited by 147
Rapid, fully automatic, arbitrary‐volume in vivo shimming
Webb, P. G., & Macovski, A. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910200112 · Cited by 137
Cross-relaxation imaging reveals detailed anatomy of white matter fiber tracts in the human brain
Yarnykh, V. L., & Yuan, C. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.04.029 · Cited by 134
The Java Image Science Toolkit (JIST) for Rapid Prototyping and Publishing of Neuroimaging Software
Lucas, B. C., Bogovic, J., Carass, A., Bazin, P., Prince, J. L., Pham, D. L., & Landman, B. A. (2010) · Neuroinformatics · doi:10.1007/s12021-009-9061-2 · Cited by 133
Self-citationThe diffusion sensitivity of fast steady‐state free precession imaging
Buxton, R. B. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290212 · Cited by 132
Topology-Preserving Tissue Classification of Magnetic Resonance Brain Images
Bazin, P., & Pham, D. L. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.893283 · Cited by 129
Koch, K. M., Papademetris, X., Rothman, D. L., & de Graaf, R. A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/24/007 · Cited by 126
Lu, H., Law, M., Johnson, G., Ge, Y., van Zijl, P. C. M., & Helpern, J. A. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20705 · Cited by 121
Regularized Field Map Estimation in MRI
Funai, A. K., Fessler, J. A., Yeo, D. T. B., Olafsson, V. T., & Noll, D. C. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.923956 · Cited by 121
Sickle Cell Disease: Continuous Arterial Spin-labeling Perfusion MR Imaging in Children
Oğuz, K. K., Golay, X., Pizzini, F. B., Freer, C. A., Winrow, N., Ichord, R., Casella, J. F., van Zijl, P. C. M., & Melhem, E. R. (2003) · Radiology · doi:10.1148/radiol.2272020903 · Cited by 118
Essig, M., Waschkies, M., Wenz, F. K., Debus, J., Hentrich, H., & Knopp, M. V. (2003) · Radiology · doi:10.1148/radiol.2281020298 · Cited by 111
Modeling pulsed magnetization transfer
Portnoy, S., & Stanisz, G. J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21244 · Cited by 109
Diffusion tensor imaging in spinal cord: methods and applications – a review
Clark, C. A., & Werring, D. J. (2002) · NMR in Biomedicine · doi:10.1002/nbm.788 · Cited by 106
Multi-contrast, isotropic, single-slab 3D MR imaging in multiple sclerosis
Moraal, B., Roosendaal, S. D., Pouwels, P. J. W., Vrenken, H., van Schijndel, R. A., Meier, D., Guttmann, C. R. G., Geurts, J. J. G., & Barkhof, F. (2008) · European Radiology · doi:10.1007/s00330-008-1009-7 · Cited by 106
Hornak, J. P., Szumowski, J., & Bryant, R. G. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060204 · Cited by 104
Kuppusamy, K., Lin, W., Cizek, G. R., & Haacke, E. M. (1996) · Radiology · doi:10.1148/radiology.201.1.8816529 · Cited by 97
Donahue, M. J., Blicher, J. U., Østergaard, L., Feinberg, D. A., MacIntosh, B. J., Miller, K. L., Günther, M., & Jezzard, P. (2009) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.107 · Cited by 95
Quantification of regional blood volumes by rapid T1 mapping
Schwarzbauer, C., Syha, J., & Haase, A. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290521 · Cited by 95
Assessing optic nerve pathology with diffusion MRI: from mouse to human
Xu, J., Sun, S., Naismith, R. T., Snyder, A. Z., Cross, A. H., & Song, S. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1307 · Cited by 93
Jin, T., & Kim, S. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.11.045 · Cited by 88
Magnetization transfer contrast with periodic pulsed saturation.
Yeung, H. N., & Aisen, A. M. (1992) · Radiology · doi:10.1148/radiology.183.1.1549673 · Cited by 81
NMR in physiology and biomedicine
(1995) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(95)90039-x · Cited by 78
Miyabe, M., Mori, S., van Zijl, P. C. M., Kirsch, J. R., Eleff, S. M., Koehler, R. C., & Traystman, R. J. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199609000-00012 · Cited by 72
Self-citationRobust field map generation using a triple‐echo acquisition
Windischberger, C., Robinson, S., Rauscher, A., et al. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20158 · Cited by 67
A simple correction for B1 field errors in magnetization transfer ratio measurements
Samson, R. S., Wheeler‐Kingshott, C. A. M. G., Symms, M. R., Tozer, D. J., & Tofts, P. S. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.10.025 · Cited by 67
Busse, R. F. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20056 · Cited by 66
Does high-field MR imaging improve cortical lesion detection in multiple sclerosis?
Geurts, J. J. G., Blezer, E. L. A., Vrenken, H., van der Toorn, A., Castelijns, J. A., Polman, C. H., Pouwels, P. J. W., Bø, L., & Barkhof, F. (2008) · Journal of Neurology · doi:10.1007/s00415-008-0620-5 · Cited by 66
High‐resolution isotropic 3D diffusion tensor imaging of the human brain
Golay, X., Jiang, H., van Zijl, P. C. M., & Mori, S. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10143 · Cited by 66
Self-citationChagla, G. H., Busse, R. F., Sydnor, R. H., Rowley, H. A., & Turski, P. A. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e3181814d28 · Cited by 65
Moseley, M. E., Chew, W. M., White, D. L., Kucharczyk, J. R., Litt, L. L., Derugin, N., DUPON, J. W., Brasch, R. C., & Norman, D. M. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230104 · Cited by 65
Magnetization transfer MRI demonstrates spinal cord abnormalities in adrenomyeloneuropathy
Fatemi, A., Smith, S. A., Dubey, P., Zackowski, K. M., Bastian, A. J., van Zijl, P. C., Moser, H. W., Raymond, G. V., & Golay, X. (2005) · Neurology · doi:10.1212/01.wnl.0000164458.02141.06 · Cited by 64
Self-citationSmith, S. A., Farrell, J. A. D., Jones, C. K., Reich, D. S., Calabresi, P. A., & van Zijl, P. C. M. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21035 · Cited by 62
Self-citationRisterucci, C., Jeanneau, K., Schöppenthau, S., Bielser, T., Künnecke, B., von Kienlin, M., & Moreau, J. (2005) · Psychopharmacology · doi:10.1007/s00213-005-2204-8 · Cited by 62
Clark, C. P., Brown, G. G., Frank, L. R., Thomas, L. S., Sutherland, A. N., & Gillin, J. C. (2006) · Psychiatry Research Neuroimaging · doi:10.1016/j.pscychresns.2005.12.008 · Cited by 59
Donahue, M. J., Blakeley, J. O., Zhou, J., Pomper, M. G., Laterra, J., & van Zijl, P. C. M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21467 · Cited by 56
Defining multiple sclerosis disease activity using MRI T2-weighted difference imaging
Lee, M. J. (1998) · Brain · doi:10.1093/brain/121.11.2095 · Cited by 51
Smith, S. A., Golay, X., Fatemi, A. S., Jones, C. K., Raymond, G. V., Moser Hugo, W., & van Zijl, P. C. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20553 · Cited by 49
Self-citationRapid radiofrequency field mapping in vivo using single‐shot STEAM MRI
Helms, G., Finsterbusch, J., Weiskopf, N., & Dechent, P. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21676 · Cited by 45
2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro
(2007) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2007.356765 · Cited by 40
Magnetization transfer enhanced vascular‐space‐occupancy (MT‐VASO) functional MRI
Hua, J., Donahue, M. J., Zhao, J. M., Grgac, K., Huang, A. J., Zhou, J., & van Zijl, P. C. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21911 · Cited by 37
Self-citationDiffusion Spectroscopy in Living Systems
van Zijl, P. C. M., Davis, D., & MOONEN, C. T. W. (1994) · Elsevier eBooks · doi:10.1016/b978-0-12-283980-1.50016-8 · Cited by 35
3D single‐shot VASO using a maxwell gradient compensated GRASE sequence
Poser, B. A., & Norris, D. G. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22000 · Cited by 33
Decreased Perfusion in Young Alcohol-Dependent Women as Compared With Age-Matched Controls
Clark, C. P., Brown, G. G., Eyler, L. T., Drummond, S. P. A., Braun, D. R., & Tapert, S. F. (2007) · The American Journal of Drug and Alcohol Abuse · doi:10.1080/00952990601082605 · Cited by 32
Development of structural MR brain imaging protocols to study genetics and maturation
Kochunov, P., & Davis, M. D. (2009) · Methods · doi:10.1016/j.ymeth.2009.08.002 · Cited by 27
Average field map image template for Echo-Planar image analysis
Gholipour, A., Kehtarnavaz, N., Gopinath, K., Briggs, R. W., & Panahi, I. M. S. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649099 · Cited by 27
3D Brain Fiber Reconstruction from Diffusion MRI
Mori, S., Crain, B. J., & van Zijl, P. C. M. (1998) · NeuroImage · doi:10.1016/s1053-8119(18)31543-x · Cited by 25
Self-citationImproved shimming for fMRI specifically optimizing the local BOLD sensitivity
Balteau, E., Hutton, C., & Weiskopf, N. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.08.010 · Cited by 23
Valette, J., Guillermier, M., Boumezbeur, F., Poupon, C., Amadon, A., Hantraye, P., & Lebon, V. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20511 · Cited by 13
Cann, S. A. H., Netten, J. P. V., & Netten, C. V. (2000) · Pure Amsterdam UMC · doi:10.1002/1531-8249(200003)47:3
Glover (2000) · doi:10.1002/1522-2594(200007)44:1<162::aid-mrm23>3.0.co;2-e
(1999) · doi:10.1002/1531-8249(199902)45:2<265::aid-ana21>3.0.co;2-3
Cited by
The multimodal brain tumor image segmentation benchmark (BRATS)
Menze, B. H., Jakab, A., Bauer, S., Kalpathy-Cramer, J., Farahani, K., Kirby, J., Burren, Y., Porz, N., Slotboom, J., Wiest, R., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2377694 · Cited by 6,781
101 Labeled Brain Images and a Consistent Human Cortical Labeling Protocol
Klein, A., & Tourville, J. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00171 · Cited by 1,202
Large-scale evaluation of ANTs and FreeSurfer cortical thickness measurements
Tustison, N. J., Cook, P. A., Klein, A., Song, G., Das, S. R., Duda, J. T., Kandel, B. M., van Strien, N., Stone, J. R., Gee, J. C., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.05.044 · Cited by 670
FastSurfer - A fast and accurate deep learning based neuroimaging pipeline
Henschel, L., Conjeti, S., Estrada, S., Diers, K., Fischl, B., & Reuter, M. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117012 · Cited by 660
Marcus, D. S., Fotenos, A. F., Csernansky, J. G., Morris, J. C., & Buckner, R. L. (2010) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2009.21407 · Cited by 631
Metadata
- Authors
- Landman, B. A., Huang, A. J., Gifford, A., Vikram, D. S., Lim, I. A. L., Farrell, J. A. D., Bogovic, J. A., Hua, J., Chen, M., Jarso, S., Smith, S. A., Joel, S., Mori, S., Pekar, J. J., Barker, P. B., Prince, J. L., & van Zijl, P. C. M.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2011-02
- Volume
- 54
- Issue
- 4
- Pages
- 2854-2866
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2140854449
- Cited by
- 299
- References
- 135
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.