The DOI matches its Crossref record; 169 of the 169 references it cites were found in a registry or an index.
Biosensor nanoengineering: Design, operation, and implementation for biomolecular analysis
Open accessAbstract
Robust, reliable, and quantitative detection of biomarkers at ultra-low concentration is of great importance in clinical settings. Biosensor, an analytical device used for sensitive and selective detection of biomarkers offers various advantages over the conventional clinical diagnosis, which is both time consuming and not suitable for point of care/onsite diagnosis. A revolution in the understanding and synthesis of nanomaterials in the last couple of decades contributed significantly to the development of the biosensors in terms of sensitivity, catalytic activity, biocompatibility, and robustness. Additionally, nanomaterials help in miniaturization of the sensing platform and helping in the commercial success of portable biosensor kits. Surface engineering equally contributed to the biosensor development by ensuring a reproducible and stable sensing surface, efficient analyte-biorecognition element interaction, and reduced fouling effect in biological solution. Due to nanomaterial integration and surface engineering, biosensors are now equally sensitive to the lab-based sophisticated instruments to detect a wide range of molecules of clinical significance. In this review, various types of biosensors, their designs, and their working principles have been discussed. A detailed account of various types of nanomaterials, their functionalization and characterization have also been discussed. The analytical performances of biosensors for both clinical validation and analyte detection have been incorporated here. The recent trends in advanced biosensors, such as smartphone interface for biosensing, nanozymes, lab-on-a-chip based detection methods have been discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electric Field Effect in Atomically Thin Carbon Films
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Zhang, Y., Dubonos, S. V., Grigorieva, I. V., & Firsov, A. A. (2004) · Science · doi:10.1126/science.1102896 · Cited by 66,834
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,822
Intrinsic peroxidase-like activity of ferromagnetic nanoparticles
Gao, L., Zhuang, J., Nie, L., Zhang, J., Zhang, Y., Gu, N., Wang, T., Feng, J., Yang, D., Perrett, S., et al. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.260 · Cited by 7,483
Laviron, E. (1979) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(79)80075-3 · Cited by 7,234
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Interpretation of Infrared Spectra, A Practical Approach
Coates, J. (2000) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a5606 · Cited by 4,411
A practical beginner’s guide to cyclic voltammetry
Elgrishi, N., Rountree, K. J., McCarthy, B. D., Rountree, E. S., Eisenhart, T. T., & Dempsey, J. L. (2018) · Journal of Chemical Education · doi:10.1021/acs.jchemed.7b00361 · Cited by 4,263
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes (II)
Wu, J., Wang, X., Wang, Q., Lou, Z., Li, S., Zhu, Y., Qin, L., & Wei, H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00457a · Cited by 4,108
Ultra-large-scale syntheses of monodisperse nanocrystals
Park, J., An, K., Hwang, Y., Park, J.-G., Noh, H.-J., Kim, J.-Y., Park, J.-H., Hwang, N.-M., & Hyeon, T. (2004) · Nature Materials · doi:10.1038/nmat1251 · Cited by 4,076
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes
Wei, H., & Wang, E. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35486e · Cited by 3,779
Nanozymes: Classification, Catalytic Mechanisms, Activity Regulation, and Applications
Huang, Y., Ren, J., & Qu, X. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00672 · Cited by 3,523
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Review on nanoparticles and nanostructured materials: history, sources, toxicity and regulations
Jeevanandam, J., Barhoum, A., Chan, Y. S., Dufresne, A., & Danquah, M. K. (2018) · Beilstein Journal of Nanotechnology · doi:10.3762/bjnano.9.98 · Cited by 3,297
Advanced Carbon Electrode Materials for Molecular Electrochemistry
McCreery, R. L. (2008) · Chemical Reviews · doi:10.1021/cr068076m · Cited by 2,729
Mourdikoudis, S., Pallares, R. M., & Thanh, N. T. K. (2018) · Nanoscale · doi:10.1039/c8nr02278j · Cited by 2,191
Park, H., Harris, S. M., Boldenow, E., Aronoff, D. M., Rea, M., Xi, C., & Loch‐Caruso, R. (2024) · American Journal of Reproductive Immunology · doi:10.1111/aji.13807 · Cited by 2,087
Migneault, I., Dartiguenave, C., Bertrand, M. J., & Waldron, K. C. (2004) · BioTechniques · doi:10.2144/04375rv01 · Cited by 1,816
Electrochemical biosensors: recommended definitions and classification
Thévenot, D. R., Toth, K., Durst, R. A., & Wilson, G. S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00115-4 · Cited by 1,727
Fundamentals of Fourier Transform Infrared Spectroscopy
Smith, B. C. (2011) · CRC Press eBooks · doi:10.1201/b10777 · Cited by 1,658
Sapsford, K. E., Algar, W. R., Berti, L., Gemmill, K. B., Casey, B. J., Oh, E., Stewart, M. H., & Medintz, I. L. (2013) · Chemical Reviews · doi:10.1021/cr300143v · Cited by 1,423
Rodahl, M., Höök, F., Krozer, A., Brzezinski, P., & Kasemo, B. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145396 · Cited by 1,296
Catalytically Active Nanomaterials: A Promising Candidate for Artificial Enzymes
Lin, Y., Ren, J., & Qu, X. (2014) · Accounts of Chemical Research · doi:10.1021/ar400250z · Cited by 1,252
Dresselhaus, M. S., & Eklund, P. C. (2000) · Advances in Physics · doi:10.1080/000187300413184 · Cited by 1,241
Macdonald, J. R. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368532 · Cited by 1,166
Etzioni, R., Urban, N., Ramsey, S., McIntosh, M., Schwartz, S., Reid, B., Radich, J., Anderson, G., & Hartwell, L. (2003) · Nature Reviews Cancer · doi:10.1038/nrc1041 · Cited by 1,155
Immobilization strategies to develop enzymatic biosensors
Sassolas, A., Blum, L. J., & Leca-Bouvier, B. D. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.09.003 · Cited by 1,130
Banks, C. E., Davies, T. J., Wildgoose, G. G., & Compton, R. G. (2005) · Chemical Communications · doi:10.1039/b413177k · Cited by 1,023
Bioassay of prostate-specific antigen (PSA) using microcantilevers
Wu, G., Datar, R. H., Hansen, K. M., Thundat, T., Cote, R. J., & Majumdar, A. (2001) · Nature Biotechnology · doi:10.1038/nbt0901-856 · Cited by 1,013
Introductory Raman Spectroscopy
(2003) · Elsevier eBooks · doi:10.1016/b978-0-12-254105-6.x5000-8 · Cited by 980
Damborský, P., Švitel, J., & Katrlík, J. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150010 · Cited by 907
Electrochemical biosensors for pathogen detection
Cesewski, E., & Johnson, B. N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112214 · Cited by 902
Protein Immobilization Strategies for Protein Biochips
Rusmini, F., Zhong, Z., & Feijen, J. (2007) · Biomacromolecules · doi:10.1021/bm061197b · Cited by 869
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Kissinger, P. T., & Heineman, W. R. (1983) · Journal of Chemical Education · doi:10.1021/ed060p702 · Cited by 771
Atomic force microscopy as a multifunctional molecular toolbox in nanobiotechnology
Müller, D. J., & Dufrêne, Y. F. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.100 · Cited by 752
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Nanostructured metal oxide-based biosensors
Solanki, P. R., Kaushik, A., Agrawal, V. V., & Malhotra, B. D. (2011) · NPG Asia Materials · doi:10.1038/asiamat.2010.137 · Cited by 663
Wongkaew, N., Simsek, M., Griesche, C., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00172 · Cited by 657
Biosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 647
Recent developments in the field of screen-printed electrodes and their related applications
Renedo, O. D., Alonso-Lomillo, M. A., & Martínez, M. J. A. (2007) · Talanta · doi:10.1016/j.talanta.2007.03.050 · Cited by 647
Metal oxide nanoparticles in electrochemical sensing and biosensing: a review
George, J. M., Antony, A., & Mathew, B. (2018) · Microchimica Acta · doi:10.1007/s00604-018-2894-3 · Cited by 580
Rocchitta, G., Spanu, A., Babudieri, S., Latte, G., Madeddu, G., Galleri, G., Nuvoli, S., Bagella, P., Demartis, M., Fiore, V., et al. (2016) · Sensors · doi:10.3390/s16060780 · Cited by 555
Liu, Y., Wang, M., Zhao, F., Xu, Z., & Dong, S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.03.003 · Cited by 552
Aptamer-based biosensors for biomedical diagnostics
Zhou, W., Jimmy Huang, P.-J., Ding, J., & Liu, J. (2014) · The Analyst · doi:10.1039/c4an00132j · Cited by 539
Guide to Selecting a Biorecognition Element for Biosensors
Morales, M. A., & Halpern, J. M. (2018) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.8b00592 · Cited by 539
Electrochemical Biosensor Applications of Polysaccharides Chitin and Chitosan
Suginta, W., Khunkaewla, P., & Schulte, A. (2013) · Chemical Reviews · doi:10.1021/cr300325r · Cited by 521
Current status of optical fiber biosensor based on surface plasmon resonance
Zhao, Y., Tong, R.-J., Xia, F., & Peng, Y. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111505 · Cited by 507
Voltammetric techniques for the assay of pharmaceuticals—A review
Gupta, V. K., Jain, R., Radhapyari, K., Jadon, N., & Agarwal, S. (2011) · Analytical Biochemistry · doi:10.1016/j.ab.2010.09.027 · Cited by 504
Chemical Sensors and Biosensors
Eggins, B. R. (2002) · Cited by 497
Measuring cell-generated forces: a guide to the available tools
Polacheck, W. J., & Chen, C. S. (2016) · Nature Methods · doi:10.1038/nmeth.3834 · Cited by 489
Streptavidin–biotin technology: improvements and innovations in chemical and biological applications
Dundas, C. M., Demonte, D., & Park, S. (2013) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-013-5232-z · Cited by 467
Sabaté del Río, J., Henry, O. Y. F., Jolly, P., & Ingber, D. E. (2019) · Nature Nanotechnology · doi:10.1038/s41565-019-0566-z · Cited by 450
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
Commercialization of microfluidic devices
Volpatti, L. R., & Yetisen, A. K. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.010 · Cited by 432
Biosensors based on graphene oxide and its biomedical application
Lee, J., Kim, J., Kim, S., & Min, D.-H. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.06.001 · Cited by 410
Dekanski, A. B., Stevanović, J., Stevanović, R. M., Nikolić, B., & Jovanović, V. M. (2001) · Carbon · doi:10.1016/s0008-6223(00)00228-1 · Cited by 403
Antibodies and antibody-derived analytical biosensors
Sharma, S., Byrne, H., & O'Kennedy, R. J. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150002 · Cited by 396
Biosensors based on nanomechanical systems
Tamayo, J., Kosaka, P. M., Ruz, J. J., San Paulo, Á., & Calleja, M. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35293a · Cited by 391
Protein immobilization techniques for microfluidic assays
Kim, D., & Herr, A. E. (2013) · Biomicrofluidics · doi:10.1063/1.4816934 · Cited by 376
Wearable Contact Lens Biosensors for Continuous Glucose Monitoring Using Smartphones
Elsherif, M., Hassan, M. U., Yetisen, A. K., & Butt, H. (2018) · ACS Nano · doi:10.1021/acsnano.8b00829 · Cited by 371
Integrated planar optical waveguide interferometer biosensors: A comparative review
Kozma, P., Kehl, F., Ehrentreich-Förster, E., Stamm, C., & Bier, F. F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.02.049 · Cited by 324
Recent advances in potentiometric biosensors
Ding, J., & Qin, W. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115803 · Cited by 322
Cell-based biosensors: Recent trends, challenges and future perspectives
Gupta, N., Renugopalakrishnan, V., Liepmann, D., Paulmurugan, R., & Malhotra, B. D. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111435 · Cited by 318
Status of biomolecular recognition using electrochemical techniques
Sadik, O. A., Aluoch, A. O., & Zhou, A. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.003 · Cited by 315
Biosensing using dynamic-mode cantilever sensors: A review
Johnson, B. N., & Mutharasan, R. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.10.054 · Cited by 314
Zhang, W., Zhu, S., Luque, R., Han, S., Hu, L., & Xu, G. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00297d · Cited by 313
The principles and applications of avidin-based nanoparticles in drug delivery and diagnosis
Jain, A., & Cheng, K. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.11.016 · Cited by 304
Smartphone based bioanalytical and diagnosis applications: A review
Kanchi, S., Sabela, M. I., Mdluli, P. S., Inamuddin, & Bisetty, K. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.11.021 · Cited by 290
Paper based diagnostics for personalized health care: Emerging technologies and commercial aspects
Mahato, K., Srivastava, A., & Chandra, P. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.05.001 · Cited by 280
Self-citationElectrical properties of vacuum-deposited indium oxide and indium tin oxide films
Mizuhashi, M. (1980) · Thin Solid Films · doi:10.1016/0040-6090(80)90415-0 · Cited by 263
Pang, Y., Wang, C., Lu, L., Wang, C., Sun, Z., & Xiao, R. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.039 · Cited by 251
Sekine, Y., Kim, S. B., Zhang, Y., Bandodkar, A. J., Xu, S., Choi, J., Irie, M., Ray, T. R., Kohli, P., Kozai, N., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00530c · Cited by 242
A review on electrochemical detection of serotonin based on surface modified electrodes
Sharma, S., Singh, N., Tomar, V., & Chandra, R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.02.013 · Cited by 236
Li, H., Dauphin-Ducharme, P., Ortega, G., & Plaxco, K. W. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b05412 · Cited by 233
Mahato, K., & Chandra, P. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.12.006 · Cited by 228
Self-citationHui, N., Sun, X., Niu, S., & Luo, X. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b11682 · Cited by 227
Nanoparticle Technology Handbook
(2007) · Nano Today · doi:10.1016/s1748-0132(07)70119-6 · Cited by 226
Braun, T., Ghatkesar, M. K., Backmann, N., Grange, W., Boulanger, P., Letellier, L., Lang, H.-P., Bietsch, A., Gerber, C., & Hegner, M. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2008.398 · Cited by 224
Conducting polymer based electrochemical biosensors
Aydemir, N., Malmström, J., & Travas-Sejdic, J. (2016) · Physical Chemistry Chemical Physics · doi:10.1039/c5cp06830d · Cited by 224
Yang, L., & Li, Y. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.06.024 · Cited by 221
Selectivity and Specificity: Pros and Cons in Sensing
Peveler, W. J., Yazdani, M., & Rotello, V. M. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00564 · Cited by 218
Development and Applications of Bioluminescent and Chemiluminescent Reporters and Biosensors
Yeh, H.-W., & Ai, H.-W. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-115027 · Cited by 215
The Piezoelectric Biosensors: Principles and Applications, a Review
Pohanka, M. (2016) · International Journal of Electrochemical Science · doi:10.20964/2017.01.44 · Cited by 208
Screen-printed disposable electrodes: Pharmaceutical applications and recent developments
Mohamed, H. M. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.02.010 · Cited by 204
Xi, J., Xie, C., Zhang, Y., Wang, L., Xiao, J., Duan, X., Ren, J., Xiao, F., & Wang, S. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b05561 · Cited by 196
Mahato, K., Nagpal, S., Shah, M. A., Srivastava, A., Maurya, P. K., Roy, S., Jaiswal, A., Singh, R., & Chandra, P. (2019) · 3 Biotech · doi:10.1007/s13205-019-1577-z · Cited by 194
Self-citationRecent developments in quantitative SERS: Moving towards absolute quantification
Goodacre, R., Graham, D., & Faulds, K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.03.005 · Cited by 192
Recent advances in nanorobotic manipulation inside scanning electron microscopes
Shi, C., Luu, D. K., Yang, Q., Liu, J., Chen, J., Ru, C., Xie, S., Luo, J., Ge, J., & Sun, Y. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.24 · Cited by 191
Microcantilever-based platforms as biosensing tools
Alvarez, M., & Lechuga, L. M. (2010) · The Analyst · doi:10.1039/b908503n · Cited by 185
Nanobiosensors for Personalized and Onsite Biomedical Diagnosis
Chandra, P., & Segal, E. (2016) · Institution of Engineering and Technology eBooks · doi:10.1049/pbhe001e · Cited by 184
Self-citationBlueprints for Biosensors: Design, Limitations, and Applications
Carpenter, A. C., Paulsen, I. T., & Williams, T. C. (2018) · Genes · doi:10.3390/genes9080375 · Cited by 183
Mechanistic Challenges and Advantages of Biosensor Miniaturization into the Nanoscale
Soleymani, L., & Li, F. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00069 · Cited by 177
Microfluidic Devices for Forensic DNA Analysis: A Review
Bruijns, B., van Asten, A., Tiggelaar, R. M., & Gardeniers, H. J. G. E. (2016) · Biosensors · doi:10.3390/bios6030041 · Cited by 171
Yüce, M., & Kurt, H. (2017) · RSC Adv. · doi:10.1039/c7ra10479k · Cited by 171
Fundamentals and commercial aspects of nanobiosensors in point-of-care clinical diagnostics
Mahato, K., Maurya, P. K., & Chandra, P. (2018) · 3 Biotech · doi:10.1007/s13205-018-1148-8 · Cited by 167
Self-citationCurrent trends in the development of conducting polymers-based biosensors
Ghorbani Zamani, F., Moulahoum, H., Ak, M., Odaci Demirkol, D., & Timur, S. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.05.031 · Cited by 161
Engineering Biosensors with Extended, Narrowed, or Arbitrarily Edited Dynamic Range
Vallée‐Bélisle, A., Ricci, F., & Plaxco, K. W. (2011) · Journal of the American Chemical Society · doi:10.1021/ja209850j · Cited by 160
Anomalous resonance in a nanomechanical biosensor
Gupta, A. K., Nair, P. R., Akin, D., Ladisch, M. R., Broyles, S., Alam, M. A., & Bashir, R. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602022103 · Cited by 160
Electrochemical Techniques for Intercalation Electrode Materials in Rechargeable Batteries
Zhu, Y., Gao, T., Fan, X., Han, F., & Wang, C. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00031 · Cited by 160
Smartphone-assisted personalized diagnostic devices and wearable sensors
Purohit, B., Kumar, A., Mahato, K., & Chandra, P. (2020) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2019.08.015 · Cited by 159
Self-citationAdvanced “lab-on-a-chip” to detect viruses – Current challenges and future perspectives
Zhuang, J., Yin, J., Lv, S., Wang, B., & Mu, Y. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112291 · Cited by 158
Characterization of Nanomaterials by Physical Methods
Rao, C. N. R., & Biswas, K. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-060908-155236 · Cited by 155
Wang, X., Li, F., Cai, Z., Liu, K., Li, J., Zhang, B., & He, J. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-0939-4 · Cited by 149
Direct detection of a BRAF mutation in total RNA from melanoma cells using cantilever arrays
Huber, F., Lang, H. P., Backmann, N., Rimoldi, D., & Gerber, C. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.263 · Cited by 146
Leland C. Clark Jr. (1918–2005)
Heineman, W. R., & Jensen, W. B. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.12.005 · Cited by 145
O'Neill, R. D., Chang, S., Lowry, J. P., & McNeil, C. J. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.12.004 · Cited by 144
Zhang, D., Jiang, J., Chen, J., Zhang, Q. Y., Lu, Y., Yao, Y., Li, S., Liu, G. L., & Liu, Q. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.004 · Cited by 143
Mahato, K., Purohit, B., Bhardwaj, K., Jaiswal, A. K., & Chandra, P. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111502 · Cited by 141
Self-citationMonitoring the Electrochemistry of Single Molecules by Surface-Enhanced Raman Spectroscopy
Cortés, E., Etchegoin, P., Ru, E. C. L., Fainstein, A., Vela, M. E., & Salvarezza, R. C. (2010) · Journal of the American Chemical Society · doi:10.1021/ja108989b · Cited by 138
Cell-based biosensors and its application in biomedicine
Wang, P., Xu, G., Qin, L., Xu, Y., Li, Y., & Li, R. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.11.056 · Cited by 137
Sarma, D. D., Santra, P. K., Mukherjee, S., & Nag, A. (2013) · Chemistry of Materials · doi:10.1021/cm303567d · Cited by 125
Kumar, A., Purohit, B., Maurya, P. K., Pandey, L. M., & Chandra, P. (2019) · Electroanalysis · doi:10.1002/elan.201900216 · Cited by 125
Self-citationPurohit, B., Mahato, K., Kumar, A., & Chandra, P. (2019) · Microchimica Acta · doi:10.1007/s00604-019-3773-2 · Cited by 120
Self-citationIdili, A., Parolo, C., Ortega, G., & Plaxco, K. W. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01703 · Cited by 119
Baranwal, A., & Chandra, P. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.09.002 · Cited by 117
Self-citationEvolving trends in bio/chemical sensor fabrication incorporating bimetallic nanoparticles
Mandal, R., Baranwal, A., Srivastava, A., & Chandra, P. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.06.039 · Cited by 115
Self-citationChung, S., Chandra, P., Koo, J. P., & Shim, Y. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.09.031 · Cited by 112
Self-citationFunctional Polymers Structures for (Bio)Sensing Application—A Review
Spychalska, K., Zając, D., Baluta, S., Halicka, K., & Cabaj, J. (2020) · Polymers · doi:10.3390/polym12051154 · Cited by 105
Tsai, D., Davila-Morris, M., DelRio, F. W., Guha, S., Zachariah, M. R., & Hackley, V. A. (2011) · Langmuir · doi:10.1021/la2005425 · Cited by 104
Voltammetric aptasensors for protein disease biomarkers detection: A review
Meirinho, S. G., Dias, L. G., Peres, A. M., & Rodrigues, L. R. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.05.006 · Cited by 104
Advanced biosensors for monitoring astronauts’ health during long-duration space missions
Roda, A., Mirasoli, M., Guardigli, M., Zangheri, M., Caliceti, C., Calabria, D., & Simoni, P. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.03.062 · Cited by 102
Kumar, T. H. V., & Sundramoorthy, A. K. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.05.011 · Cited by 101
Biosensors in Clinical Practice: Focus on Oncohematology
Fracchiolla, N., Artuso, S., & Cortelezzi, A. (2013) · Sensors · doi:10.3390/s130506423 · Cited by 100
Dermal Tattoo Biosensors for Colorimetric Metabolite Detection
Yetisen, A. K., Moreddu, R., Seifi, S., Jiang, N., Vega, K. C., Dong, X., Dong, J., Butt, H., Jakobi, M., Elsner, M., et al. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201904416 · Cited by 100
Mahapatra, S., & Chandra, P. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112361 · Cited by 99
Self-citationBhatnagar, I., Mahato, K., Ealla, K. K. R., Asthana, A., & Chandra, P. (2017) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2017.12.084 · Cited by 96
Self-citationBiosensors Based on Microfluidic Devices Lab-on-a-Chip and Microfluidic Technology
Nikoleli, G., Siontorou, C. G., Nikolelis, D. P., Bratakou, S., Karapetis, S. K., & Tzamtzis, N. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813855-7.00013-1 · Cited by 96
Chandra, P. (2020) · Sensors International · doi:10.1016/j.sintl.2020.100019 · Cited by 96
Self-citationRooney, M. B., Coomber, D. C., & Bond, A. M. (2000) · Analytical Chemistry · doi:10.1021/ac991464m · Cited by 93
Advance Engineered Nanomaterials in Point-of-care Immunosensing for Biomedical Diagnostics
Kumar, A., Purohit, B., Mahato, K., & Chandra, P. (2019) · Royal Society of Chemistry eBooks · doi:10.1039/9781788016162-00238 · Cited by 92
Self-citationMEMS sensors and microsystems for cell mechanobiology
Rajagopalan, J., & Saif, M. T. A. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/5/054002 · Cited by 91
Real-time Detection of Breast Cancer Cells Using Peptide-functionalized Microcantilever Arrays
Etayash, H., Jiang, K., Azmi, S., Thundat, T. G., & Kaur, K. (2015) · Scientific Reports · doi:10.1038/srep13967 · Cited by 91
Chandra, P., Son, N. X., Noh, H., Goyal, R. N., & Shim, Y. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.006 · Cited by 89
Self-citationChandra, P., Noh, H., Pallela, R., & Shim, Y. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.069 · Cited by 84
Self-citationHigh-Curvature Nanostructuring Enhances Probe Display for Biomolecular Detection
Luna, P. D., Mahshid, S. S., Das, J., Luan, B., Sargent, E. H., Kelley, S. O., & Zhou, R. (2017) · Nano Letters · doi:10.1021/acs.nanolett.6b05153 · Cited by 84
Zhang, S., Huang, Q., Zhang, L., Zhang, H., Han, Y., Sun, Q., Cheng, Z., Qin, H., Dou, S. X., & Li, Z. (2017) · Nanoscale · doi:10.1039/c7nr06937e · Cited by 82
Akhtar, M. H., Hussain, K. K., Gurudatt, N. G., Chandra, P., & Shim, Y. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.049 · Cited by 77
Self-citationPurohit, B., Kumar, A., Mahato, K., & Chandra, P. (2019) · Electroanalysis · doi:10.1002/elan.201900551 · Cited by 77
Self-citationNanobiosensors for personalized and onsite biomedical diagnosis
Chandra, P., & Segal, E. (2016) · CERN Document Server (European Organization for Nuclear Research) · Cited by 76
Self-citationPurohit, B., Kumar, A., Mahato, K., Roy, S., & Chandra, P. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-818823-1.00009-0 · Cited by 75
Self-citationKumar, A., Purohit, B., Mahato, K., Mandal, R., Srivastava, A., & Chandra, P. (2019) · Electroanalysis · doi:10.1002/elan.201900337 · Cited by 74
Self-citationBaranwal, A., Chiranjivi, A. K., Kumar, A., Dubey, V. K., & Chandra, P. (2018) · Scientific Reports · doi:10.1038/s41598-018-27170-1 · Cited by 72
Self-citationKumar, A., Roy, S., Srivastava, A., Naikwade, M. M., Purohit, B., Mahato, K., Naidu, V. G. M., & Chandra, P. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-818823-1.00010-7 · Cited by 72
Self-citationNanoscale bacteriophage biosensors beyond phage display
Lee, K. H., Lee, J., Song, J., & Hwang, M. P. (2013) · International Journal of Nanomedicine · doi:10.2147/ijn.s51894 · Cited by 71
Chemical Sensors and Biosensors
McMahon, G. P. (2007) · Wiley eBooks · doi:10.1002/9780470612231.ch6 · Cited by 70
Enabling miniaturised personalised diagnostics: from lab-on-a-chip to lab-in-a-drop
Koo, K. M., Wee, E. J. H., Wang, Y., & Trau, M. (2017) · Lab on a Chip · doi:10.1039/c7lc00587c · Cited by 66
Multifunctional hydrogel nano-probes for atomic force microscopy
Lee, J. S., Song, J., Kim, S., Kim, S., Lee, W., Jackman, J. A., Kim, D., Cho, N., & Lee, J. (2016) · Nature Communications · doi:10.1038/ncomms11566 · Cited by 64
Can Calibration-Free Sensors Be Realized?
Bakker, E. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00247 · Cited by 63
Kailashiya, J., Singh, N. K., Singh, S. K., Agrawal, V. K., & Dash, D. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.10.056 · Cited by 62
Chandra, P., Koh, W. C. A., Noh, H., & Shim, Y. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.11.027 · Cited by 61
Self-citationImproved single molecule force spectroscopy using micromachined cantilevers.
Bull, M., Sullan, R., Li, H.-B., & Perkins, T. (2014) · ACS Nano · doi:10.1021/nn5010588 · Cited by 60
Hendel, S. J., & Young, E. R. (2016) · Journal of Chemical Education · doi:10.1021/acs.jchemed.6b00230 · Cited by 59
Fei, Y., Sun, Y.-S., Li, Y., Yu, H., Lau, K., Landry, J., Luo, Z., Baumgarth, N., Chen, X., & Zhu, X. D. (2015) · Biomolecules · doi:10.3390/biom5031480 · Cited by 58
Atomic force microscopy of virus shells
de Pablo, P. J. (2017) · Seminars in Cell and Developmental Biology · doi:10.1016/j.semcdb.2017.08.039 · Cited by 53
Proton-ELISA: Electrochemical immunoassay on a dual-gated ISFET array
Juang, D. S., Lin, C.-H., Huo, Y., Tang, C., Cheng, C.-R., Wu, H.-S., Huang, S.-F., Kalnitsky, A., & Lin, C.-C. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.06.012 · Cited by 51
Pawlak, M., Grygołowicz‐Pawlak, E., Crespo, G. A., Mistlberger, G., & Bakker, E. (2013) · Electroanalysis · doi:10.1002/elan.201300212 · Cited by 48
Killard, A. J. (2017) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2017.06.013 · Cited by 37
Atomic force microscopy of virus shells
Moreno‐Madrid, F., Martín-González, N., Llauró, A., Ortega-Esteban, Á., Hernando‐Pérez, M., Douglas, T., Schaap, I. A. T., & de Pablo, P. J. (2017) · Biochemical Society Transactions · doi:10.1042/bst20160316 · Cited by 35
Mahato, K., Purohit, B., Kumar, A., & Chandra, P. (2020) · Comprehensive analytical chemistry · doi:10.1016/bs.coac.2020.02.001 · Cited by 32
Self-citationRen, H., Coughlin, M. A., Major, T. C., Aiello, S., Rojas Pena, A., Bartlett, R. H., & Meyerhoff, M. E. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01590 · Cited by 30
Nanomaterial Functionalization Strategies in Bio-Interface Development for Modern Diagnostic Devices
Mahato, K., Kumar, A., Purohit, B., Mahapatra, S., Srivastava, A., & Chandra, P. (2020) · Springer eBooks · doi:10.1007/978-981-15-4790-4_9 · Cited by 29
Self-citationElectrodeposition of Metallic Nanostructures for Biosensing Applications in Health Care
Purohit, B., Kumar, A., Mahato, K., & Chandra, P. (2020) · Journal of scientific research · doi:10.37398/jsr.2020.640109 · Cited by 28
Self-citationCalibration free concentration analysis by surface plasmon resonance in a capture mode
Visentin, J., Minder, L., Lee, J.-H., Taupin, J., & Primo, C. D. (2015) · Talanta · doi:10.1016/j.talanta.2015.11.025 · Cited by 26
Kumar, A., Purohit, B., Mahato, K., Mahapatra, S., Srivastava, A., & Chandra, P. (2020) · Springer eBooks · doi:10.1007/978-981-15-4790-4_10 · Cited by 22
Self-citationNanomaterial based self-referencing microbiosensors for cell and tissue physiology research
Shi, J. P., McLamore, E. S., & Porterfield, D. M. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.06.059 · Cited by 19
Shetti, N. P., Malode, S. J., Roy, S., Chandra, P., Reddy, K. R., & Chatterjee, S. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-817923-9.00011-0 · Cited by 14
Self-citationSingle Cell Analysis of Neutrophils NETs by Microscopic LSPR Imaging System
Ali, R. A. M., Mita, D., Espulgar, W. V., Saito, M., Nishide, M., Takamatsu, H., Yoshikawa, H., & Tamiya, E. (2019) · Micromachines · doi:10.3390/mi11010052 · Cited by 11
Kramer, K., & Hock, B. (2004) · Springer series on chemical sensors and biosensors · doi:10.1007/978-3-662-05204-4_1 · Cited by 9
Cited by
Telemedicine for Healthcare: Capabilities, Features, Barriers, and Applications
Haleem, A., Javaid, M., Singh, R. P., & Suman, R. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100117 · Cited by 1,638
Biosensors applications in medical field: A brief review
Haleem, A., Javaid, M., Singh, R. P., Suman, R., & Rab, S. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100100 · Cited by 600
Significance of sensors for industry 4.0: Roles, capabilities, and applications
Javaid, M., Haleem, A., Singh, R. P., Rab, S., & Suman, R. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100110 · Cited by 355
Internet of behaviours (IoB) and its role in customer services
Javaid, M., Haleem, A., Singh, R. P., Rab, S., & Suman, R. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100122 · Cited by 80
Metadata
- Authors
- Purohit, B., Vernekar, P. R., Shetti, N. P., & Chandra, P.
- Venue
- Sensors International
- Publisher
- Elsevier BV
- Published
- 2020
- Volume
- 1
- Pages
- 100040
- ISSN
- 2666-3511 (ISSN-L)
- OpenAlex
- W3084351276
- Cited by
- 421
- References
- 169
- FWCI
- 18.82
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.