The DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Trends in miniaturized biosensors for point-of-care testing
Abstract
The popularization of point-of-care (POC) testing is of great importance in healthcare diagnostics and other fields in the developing world, especially in resource-limited settings. To date, there are still great challenges in the development of simple, quick, affordable, yet highly effective and selective biosensors for POC testing. To meet the increasing need for POC testing, researchers need to consider biosensor miniaturization. In this review, we focus on recent advances in miniaturized biosensors for POC testing. We first review the miniaturization strategies, including handheld instruments and microfluidics-assisted miniaturized biosensing systems. Recent progress in recognition biosensing interactions for miniaturized biosensing systems is then summarized. We further describe how POC testing applications can be realized based on developments in integration, automation and multiplexing. Finally, the future prospects and remaining challenges of miniaturized biosensors for POC testing are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Self-citationFunctional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Diagnostics for the developing world
Mabey, D., Peeling, R. W., Ustianowski, A., & Perkins, M. D. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro841 · Cited by 1,054
Electrochemical Sensors and Biosensors
Kimmel, D. W., LeBlanc, G., Meschievitz, M. E., & Cliffel, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac202878q · Cited by 947
Choi, K., Ng, A. H. C., Fobel, R., & Wheeler, A. R. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143028 · Cited by 817
Diagnostic point-of-care tests in resource-limited settings
Drain, P. K., Hyle, E. P., Noubary, F., Freedberg, K. A., Wilson, D., Bishai, W. R., Rodriguez, W., & Bassett, I. V. (2014) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(13)70250-0 · Cited by 744
Using personal glucose meters and functional DNA sensors to quantify a variety of analytical targets
Xiang, Y., & Lu, Y. (2011) · Nature Chemistry · doi:10.1038/nchem.1092 · Cited by 677
Development of a digital microfluidic platform for point of care testing
Sista, R., Hua, Z., Thwar, P., Sudarsan, A., Srinivasan, V., Eckhardt, A., Pollack, M., & Pamula, V. (2008) · Lab on a Chip · doi:10.1039/b814922d · Cited by 550
Biosensors--Sense and Sensitivity
Turner, A. P. F. (2000) · Science · doi:10.1126/science.290.5495.1315 · Cited by 524
Functional nucleic acid-based hydrogels for bioanalytical and biomedical applications
Li, J., Mo, L., Lu, C.-H., Fu, T., Yang, H.-H., & Tan, W. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00586h · Cited by 520
Stimuli-Responsive DNA-Based Hydrogels: From Basic Principles to Applications
Kahn, J. S., Hu, Y., & Willner, I. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00542 · Cited by 446
Reboud, J., Xu, G., Garrett, A., Adriko, M., Yang, Z., Tukahebwa, E. M., Rowell, C., & Cooper, J. M. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1812296116 · Cited by 351
Self-powered integrated microfluidic point-of-care low-cost enabling (SIMPLE) chip
Yeh, E.-C., Fu, C.-C., Hu, L., Thakur, R., Feng, J., & Lee, L. P. (2017) · Science Advances · doi:10.1126/sciadv.1501645 · Cited by 347
Paper Electrode-Based Flexible Pressure Sensor for Point-of-Care Immunoassay with Digital Multimeter
Yu, Z., Tang, Y., Cai, G., Ren, R., & Tang, D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04635 · Cited by 341
Yan, L., Zhu, Z., Zou, Y., Huang, Y., Liu, D., Jia, S., Xu, D., Wu, M., Zhou, Y., Zhou, S., et al. (2013) · Journal of the American Chemical Society · doi:10.1021/ja3114714 · Cited by 329
Self-citationZhu, Z., Guan, Z., Jia, S., Lei, Z., Lin, S., Zhang, H., Ma, Y., Tian, Z., & Yang, C. J. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201405995 · Cited by 303
Self-citationFu, G., Sanjay, S. T., Zhou, W., Brekken, R. A., Kirken, R. A., & Li, X. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00842 · Cited by 273
Functional nucleic acid nanostructures and DNA machines
Teller, C., & Willner, I. (2010) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2010.06.001 · Cited by 241
Perspective on Optical Biosensors and Integrated Sensor Systems
Ligler, F. S. (2009) · Analytical Chemistry · doi:10.1021/ac8016289 · Cited by 240
Point-of-care technologies for molecular diagnostics using a drop of blood
Song, Y., Huang, Y.-Y., Liu, X., Zhang, X., Ferrari, M., & Qin, L. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.01.003 · Cited by 228
Self-citationMultiplexed volumetric bar-chart chip for point-of-care diagnostics
Song, Y., Zhang, Y., Bernard, P. E., Reuben, J. M., Ueno, N. T., Arlinghaus, R. B., Zu, Y., & Qin, L. (2012) · Nature Communications · doi:10.1038/ncomms2292 · Cited by 220
Self-citationWei, X., Tian, T., Jia, S., Zhu, Z., Ma, Y., Sun, J., Lin, Z., & Yang, C. J. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04294 · Cited by 210
Self-citationTranslating Bacterial Detection by DNAzymes into a Litmus Test
Tram, K., Kanda, P., Salena, B. J., Huan, S., & Li, Y. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201407021 · Cited by 203
Fabrication, modification, and application of poly(methyl methacrylate) microfluidic chips
Chen, Y., Zhang, L., & Chen, G. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200700552 · Cited by 191
Using Commercially Available Personal Glucose Meters for Portable Quantification of DNA
Xiang, Y., & Lu, Y. (2012) · Analytical Chemistry · doi:10.1021/ac203014s · Cited by 175
Xiang, Y., & Lu, Y. (2012) · Analytical Chemistry · doi:10.1021/ac300517n · Cited by 173
Kalsi, S., Valiadi, M., Tsaloglou, M.-N., Parry-Jones, L., Jacobs, A., Watson, R., Turner, C., Amos, R., Hadwen, B., Buse, J., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00462d · Cited by 164
Ye, R., Zhu, C., Song, Y., Lu, Q., Ge, X., Yang, X., Zhu, M. J., Du, D., Li, H., & Lin, Y. (2016) · Small · doi:10.1002/smll.201600273 · Cited by 149
Self-citationMa, Y., Mao, Y., Huang, D., He, Z., Yan, J., Tian, T., Shi, Y., Song, Y., Li, X., Zhu, Z., et al. (2016) · Lab on a Chip · doi:10.1039/c6lc00474a · Cited by 140
Self-citationHay Burgess, D. C., Wasserman, J., & Dahl, C. A. (2006) · Nature · doi:10.1038/nature05440 · Cited by 139
Xiang, Y., & Lu, Y. (2012) · Chemical Communications · doi:10.1039/c2cc37156a · Cited by 132
Liu, D., Li, X., Zhou, J., Liu, S., Tian, T., Song, Y., Zhu, Z., Zhou, L., Ji, T., & Yang, C. J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.04.044 · Cited by 119
Self-citationWei, X., Zhou, W., Sanjay, S. T., Zhang, J., Jin, Q., Xu, F., Domínguez, D. C., & Li, X. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02055 · Cited by 119
Overview on self-monitoring of blood glucose
Montagnana, M., Caputo, M., Giavarina, D., & Lippi, G. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.01.002 · Cited by 116
Liu, D., Jia, S., Zhang, H., Ma, Y., Guan, Z., Li, J., Zhu, Z., Ji, T., & Yang, C. J. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b05531 · Cited by 116
Self-citationLan, T., Zhang, J., & Lu, Y. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.03.002 · Cited by 111
Nucleic Acid–Based Functional Nanomaterials as Advanced Cancer Therapeutics
Yuan, Y., Gu, Z., Yao, C., Luo, D., & Yang, D. (2019) · Small · doi:10.1002/smll.201900172 · Cited by 109
Zhang, J., Xiang, Y., Wang, M., Basu, A., & Lu, Y. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201507563 · Cited by 103
Li, Y., Ma, Y., Jiao, X., Li, T., Lv, Z., Yang, C. J., Zhang, X., & Wen, Y. (2019) · Nature Communications · doi:10.1038/s41467-019-08952-1 · Cited by 103
Self-citationPang, X., Cui, C., Wan, S., Jiang, Y. Y., Zhang, L., Xia, L., Li, L., Li, X., & Tan, W. (2018) · Cancers · doi:10.3390/cancers10020047 · Cited by 99
Zhang, J., Xing, H., & Lu, Y. (2018) · Chemical Science · doi:10.1039/c7sc05325h · Cited by 94
Target-responsive DNA hydrogel for non-enzymatic and visual detection of glucose
Ma, Y., Mao, Y., An, Y., Tian, T., Zhang, H., Yan, J., Zhu, Z., & Yang, C. J. (2018) · The Analyst · doi:10.1039/c8an00010g · Cited by 86
Self-citationLi, Y., Xuan, J., Song, Y., Qi, W., He, B., Wang, P., & Qin, L. (2015) · ACS Nano · doi:10.1021/acsnano.5b07357 · Cited by 77
Ultrasensitive and Facile Detection of MicroRNA via a Portable Pressure Meter
Shi, L. D., Lei, J., Zhang, B., Li, B., Yang, C. J., & Jin, Y. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b02551 · Cited by 77
Self-citationSoda, Y., Citterio, D., & Bakker, E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01521 · Cited by 75
Versatile Barometer Biosensor Based on Au@Pt Core/Shell Nanoparticle Probe
Fu, Q., Wu, Z., Du, D., Zhu, C., Lin, Y., & Tang, Y. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00156 · Cited by 70
Si, Y., Li, L., Wang, N., Zheng, J., Yang, R., & Li, J. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b21727 · Cited by 69
Abate, M. F., Jia, S., Ahmed, M. G., Li, X., Lin, L., Chen, X., Zhu, Z., & Yang, C. J. (2019) · Small · doi:10.1002/smll.201804890 · Cited by 69
Self-citationZhang, J., Shen, Z., Xiang, Y., & Lu, Y. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00270 · Cited by 68
A pressure-based bioassay for the rapid, portable and quantitative detection of C-reactive protein
Ji, T., Liu, D., Liu, F., Li, J., Ruan, Q., Song, Y., Tian, T., Zhu, Z., Zhou, L., Lin, H., et al. (2016) · Chemical Communications · doi:10.1039/c6cc03705d · Cited by 62
Self-citationLin, B., Guan, Z., Song, Y., Song, E., Lu, Z., Liu, D., An, Y., Zhu, Z., Zhou, L., & Yang, C. J. (2018) · Lab on a Chip · doi:10.1039/c8lc00010g · Cited by 59
Self-citationAn exploration of nucleic acid liquid biopsy using a glucose meter
Gu, Y., Zhang, T., Huang, Z., Hu, S., Zhao, W., Xu, J., & Chen, H. (2018) · Chemical Science · doi:10.1039/c8sc00627j · Cited by 59
Huang, D., Lin, B., Song, Y., Guan, Z., Cheng, J., Zhu, Z., & Yang, C. J. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b15562 · Cited by 56
Self-citationWang, Q., Wang, H., Yang, X., et al. (2014) · Chemical Communications · doi:10.1039/c4cc00133h · Cited by 46
Sensitive detection of telomerase activity in cancer cells using portable pH meter as readout
Wang, L., Chen, C., Huang, H., Huang, D., Luo, F., Qiu, B., Guo, L., Lin, Z., & Yang, H. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.08.069 · Cited by 44
Facile and Sensitive Method for Detecting Cardiac Markers using Ubiquitous pH Meters
Kwon, D., Joo, J., Lee, S., & Jeon, S. (2013) · Analytical Chemistry · doi:10.1021/ac403329w · Cited by 43
Recent Progress of Microfluidics in Translational Applications
Liu, Z., Han, X., & Qin, L. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600009 · Cited by 42
Guo, Y., Yang, K., Sun, J., Wu, J., & Ju, H. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.03.066 · Cited by 42
In Situ Pt Staining Method for Simple, Stable, and Sensitive Pressure-Based Bioassays
Li, J., Liu, F., Zhu, Z., Liu, D., Chen, X., Song, Y., Zhou, L., & Yang, C. J. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b03567 · Cited by 39
Self-citationZhang, J., Xiang, Y., Novak, D. E., Hoganson, G. E., Zhu, J., & Lu, Y. (2015) · Chemistry - An Asian Journal · doi:10.1002/asia.201500642 · Cited by 36
A pH-responsive bioassay for paper-based diagnosis of exosomes via mussel-inspired surface chemistry
Yang, Y., Li, C., Shi, H., Chen, T., Wang, Z., & Li, G. (2018) · Talanta · doi:10.1016/j.talanta.2018.09.067 · Cited by 36
Enzymatic Litmus Test for Selective Colorimetric Detection of C–C Single Nucleotide Polymorphisms
Wolfe, M. G., Ali, M. M., & Brennan, J. D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00235 · Cited by 35
Song, Y., Wang, Y., Qi, W., Li, Y., Xuan, J., Wang, P., & Qin, L. (2016) · Lab on a Chip · doi:10.1039/c6lc00561f · Cited by 34
Self-citationJang, Y.-J., Lee, K.-H., Yoo, T. H., & Kim, D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05526 · Cited by 30
Using the Widely Available Blood Glucose Meter to Monitor Insulin and HbA1c
Xiang, Y., Lan, T., & Lu, Y. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814532875 · Cited by 28
Detection of Enzymes, Viruses, and Bacteria Using Glucose Meters
Das, A., Cui, X., Chivukula, V., & Iyer, S. S. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02960 · Cited by 27
Afi-Chip: An Equipment-Free, Low-Cost, and Universal Binding Ligand Affinity Evaluation Platform
Song, Y., Shi, Y., Li, X., Ma, Y., Gao, M., Liu, D., Mao, Y., Zhu, Z., Lin, H., & Yang, C. J. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b02140 · Cited by 22
Self-citationJiang, Y., Su, Z., Zhang, J., Cai, M., & Li-li, W. (2018) · The Analyst · doi:10.1039/c8an01436a · Cited by 22
A micro-pressure sensor-based analytic platform and its application in thrombin quantification
Yang, W., Li, R., Wang, Q., Wei, Q., Fu, C., Lin, Z., & Chen, G. (2015) · Analytical Methods · doi:10.1039/c5ay01907a · Cited by 10
Cited by
Recent advances in molecularly imprinted polymer-based electrochemical sensors
Li, Y., Luo, L., Kong, Y., Li, Y., Wang, Q., Wang, M., Li, Y., Davenport, A., & Li, B. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116018 · Cited by 308
Biosensors and Microfluidic Biosensors: From Fabrication to Application
Kulkarni, M. B., Ayachit, N. H., & Aminabhavi, T. M. (2022) · Biosensors · doi:10.3390/bios12070543 · Cited by 281
A layered cancer-on-a-chip system for anticancer drug screening and disease modeling
Flont, M., Dybko, A., & Jastrzębska, E. (2023) · The Analyst · doi:10.1039/d3an00959a · Cited by 21
Metadata
- Authors
- Liu, D., Wang, J., Wu, L., Huang, Y., Zhang, Y., Zhu, M., Wang, Y., Zhu, Z., & Yang, C.
- Venue
- TrAC Trends in Analytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 122
- Pages
- 115701
- ISSN
- 0165-9936 (ISSN-L)
- OpenAlex
- W2980985102
- Cited by
- 255
- References
- 72
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.