High-resolution noise substitution to measure overfitting and validate resolution in 3D structure determination by single particle electron cryomicroscopy

Open access
Chen, Shaoxia, McMullan, Greg, Faruqi, Abdul R., Murshudov, Garib N., Short, Judith M., Scheres, Sjors H.W., Henderson, Richard·2013·Ultramicroscopy

Abstract

Three-dimensional (3D) structure determination by single particle electron cryomicroscopy (cryoEM) involves the calculation of an initial 3D model, followed by extensive iterative improvement of the orientation determination of the individual particle images and the resulting 3D map. Because there is much more noise than signal at high resolution in the images, this creates the possibility of noise reinforcement in the 3D map, which can give a false impression of the resolution attained. The balance between signal and noise in the final map at its limiting resolution depends on the image processing procedure and is not easily predicted. There is a growing awareness in the cryoEM community of how to avoid such over-fitting and over-estimation of resolution. Equally, there has been a reluctance to use the two principal methods of avoidance because they give lower resolution estimates, which some people believe are too pessimistic. Here we describe a simple test that is compatible with any image processing protocol. The test allows measurement of the amount of signal and the amount of noise from overfitting that is present in the final 3D map. We have applied the method to two different sets of cryoEM images of the enzyme beta-galactosidase using several image processing packages. Our procedure involves substituting the Fourier components of the initial particle image stack beyond a chosen resolution by either the Fourier components from an adjacent area of background, or by simple randomisation of the phases of the particle structure factors. This substituted noise thus has the same spectral power distribution as the original data. Comparison of the Fourier Shell Correlation (FSC) plots from the 3D map obtained using the experimental data with that from the same data with high-resolution noise (HR-noise) substituted allows an unambiguous measurement of the amount of overfitting and an accompanying resolution assessment. A simple formula can be used to calculate an unbiased FSC from the two curves, even when a substantial amount of overfitting is present. The approach is software independent. The user is therefore completely free to use any established method or novel combination of methods, provided the HR-noise test is carried out in parallel. Applying this procedure to cryoEM images of beta-galactosidase shows how overfitting varies greatly depending on the procedure, but in the best case shows no overfitting and a resolution of ~6 Å. (382 words).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ultramic.2013.06.004

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 55

  1. Dubochet, 1988, Cryo-electron microscopy of vitrified specimens, Quarterly Reviews of Biophysics, 21, 129, 10.1017/S0033583500004297 · DOI · Paper page
  2. Taylor, 1974, Electron diffraction of frozen, hydrated protein crystals, Science, 186, 1036, 10.1126/science.186.4168.1036 · DOI · Paper page
  3. Fujiyoshi, 1991, Development of a superfluid-helium stage for high-resolution electron-microscopy, Ultramicroscopy, 38, 241, 10.1016/0304-3991(91)90159-4 · DOI
  4. Zemlin, 1996, A 200kV electron microscope with Schottky field emitter and a helium-cooled superconducting objective lens, Ultramicroscopy, 63, 227, 10.1016/0304-3991(96)00038-1 · DOI
  5. Homo, 1984, Improved anti-contaminator for cryo-electron microscopy with a Philips EM-400, Journal of Microscopy-Oxford, 136, 337, 10.1111/j.1365-2818.1984.tb00543.x · DOI
  6. Otten, 1993, High-resolution imaging on a field-emission TEM, Ultramicroscopy, 48, 77, 10.1016/0304-3991(93)90173-U · DOI
  7. Faruqi, 2011, Electronic detectors for electron microscopy, Quarterly Reviews of Biophysics, 44, 357, 10.1017/S0033583511000035 · DOI
  8. Frank, 1996, processing and visualization of images in 3D electron microscopy and related fields, Journal of Structural Biology, 116, 190, 10.1006/jsbi.1996.0030 · DOI · Paper page
  9. Grigorieff, 2007, FREALIGN: high-resolution refinement of single particle structures, Journal of Structural Biology, 157, 117, 10.1016/j.jsb.2006.05.004 · DOI · Paper page
  10. Tang, 2007, EMAN2: an extensible image processing suite for electron microscopy, Journal of Structural Biology, 157, 38, 10.1016/j.jsb.2006.05.009 · DOI · Paper page
  11. Gonen, 2005, Lipid-protein interactions in double-layered two-dimensional AQP0 crystals, Nature, 438, 633, 10.1038/nature04321 · DOI · Paper page
  12. Grigorieff, 1996, Electron-crystallographic refinement of the structure of bacteriorhodopsin, Journal of Molecular Biology, 259, 393, 10.1006/jmbi.1996.0328 · DOI · Paper page
  13. Kuhlbrandt, 1994, Atomic model of plant light-harvesting complex by electron crystallography, Nature, 367, 614, 10.1038/367614a0 · DOI · Paper page
  14. Unwin, 2005, Refined structure of the nicotinic acetylcholine receptor at 4Å resolution, Journal of Molecular Biology, 346, 967, 10.1016/j.jmb.2004.12.031 · DOI
  15. Yonekura, 2003, Complete atomic model of the bacterial flagellar filament by electron cryomicroscopy, Nature, 424, 643, 10.1038/nature01830 · DOI · Paper page
  16. Yu, 2011, Atomic model of CPV reveals the mechanism used by this single-shelled virus to economically carry out functions conserved in multishelled reoviruses, Structure, 19, 652, 10.1016/j.str.2011.03.003 · DOI
  17. Zhang, 2010, 3.3Å cryo-EM structure of a nonenveloped virus reveals a priming mechanism for cell entry, Cell, 141, 472, 10.1016/j.cell.2010.03.041 · DOI · Paper page
  18. Zhang, 2008, Near-atomic resolution using electron cryomicroscopy and single-particle reconstruction, Proceedings of the National Academy of Sciences of the United States of America, 105, 1867, 10.1073/pnas.0711623105 · DOI · Paper page
  19. Cong, 2010, 4.0Å resolution cryo-EM structure of the mammalian chaperonin TRiC/CCT reveals its unique subunit arrangement, Proceedings of the National Academy of Sciences of the United States of America, 107, 4967, 10.1073/pnas.0913774107 · DOI
  20. Mills, 2013, De novo modelling of the F420-reducing-dehydrogenase from a methanogenic archaeon by cryo-electron microscopy, eLife, 1
  21. Schuette, 2009, GTPase activation of elongation factor EF-Tu by the ribosome during decoding, EMBO Journal, 28, 755, 10.1038/emboj.2009.26 · DOI
  22. Zhang, 2013, Cryo-EM structure of a molluscan hemocyanin suggests its allosteric mechanism, Structure, 21, 604, 10.1016/j.str.2013.02.018 · DOI
  23. Henderson, 2012, Outcome of the first electron microscopy validation task force meeting, Structure, 20, 205, 10.1016/j.str.2011.12.014 · DOI · Paper page
  24. Henderson, 2011, Tilt-pair analysis of images from a range of different specimens in single-particle electron cryomicroscopy, Journal of Molecular Biology, 413, 1028, 10.1016/j.jmb.2011.09.008 · DOI
  25. Stewart, 2004, Noise bias in the refinement of structures derived from single particles, Ultramicroscopy, 102, 67, 10.1016/j.ultramic.2004.08.008 · DOI
  26. Henderson, 1986, Structure of purple membrane from Halobacterium halobium—recording, measurement and evaluation of electron micrographs at 3.5Å resolution, Ultramicroscopy, 19, 147, 10.1016/0304-3991(86)90203-2 · DOI · Paper page
  27. Morgan, 1995, Structure of bacterial flagellar filaments at 11Å resolution—packing of the alpha-helices, Journal of Molecular Biology, 249, 88, 10.1006/jmbi.1995.0282 · DOI
  28. Harautz, 1986, Exact filters for general geometry three-dimensional reconstruction, Optik, 73, 146
  29. Saxton, 1982, The correlation averaging of a regularly arranged bacterial cell envelope protein, Journal of Electron Microscopy, 127, 127, 10.1111/j.1365-2818.1982.tb00405.x · DOI · Paper page
  30. van Heel, 1982, Arthropod hemocyanin studies by image analysis, Life Chemistry Reports, 69
  31. Liao, 2010, Definition and estimation of resolution in single-particle reconstructions, Structure, 18, 768, 10.1016/j.str.2010.05.008 · DOI
  32. Penczek, 2010, Resolution measures in molecular electron microscopy, Methods in Enzymology, 482, 73, 10.1016/S0076-6879(10)82003-8 · DOI
  33. Radermacher, 1987, 3-Dimensional reconstruction from a single-exposure, random conical tilt series applied to the 50S-ribosomal subunit of Escherichia coli, Journal of Microscopy-Oxford, 146, 113, 10.1111/j.1365-2818.1987.tb01333.x · DOI · Paper page
  34. van Heel, 1987, Angular reconstitution—a posteriori assignment of projection directions for 3-D reconstruction, Ultramicroscopy, 21, 111, 10.1016/0304-3991(87)90078-7 · DOI · Paper page
  35. Penczek, 1992, Three-dimensional reconstruction of single particles embedded in ice, Ultramicroscopy, 40, 33, 10.1016/0304-3991(92)90233-A · DOI · Paper page
  36. Shatsky, 2009, A method for the alignment of heterogeneous macromolecules from electron microscopy, Journal of Structural Biology, 166, 67, 10.1016/j.jsb.2008.12.008 · DOI
  37. Grigorieff, 2000, Resolution measurement in structures derived from single particles, Acta Crystallographica Section D-biological Crystallography, 56, 1270, 10.1107/S0907444900009549 · DOI
  38. Scheres, 2012, A Bayesian view on cryo-EM structure determination, Journal of Molecular Biology, 415, 406, 10.1016/j.jmb.2011.11.010 · DOI · Paper page
  39. Shaikh, 2003, An approach to examining model dependence in EM reconstructions using cross-validation, Journal of Structural Biology, 142, 301, 10.1016/S1047-8477(03)00029-7 · DOI
  40. Grigorieff, 2011, Near-atomic resolution reconstructions of icosahedral viruses from electron cryo-microscopy, Current Opinion in Structural Biology, 21, 265, 10.1016/j.sbi.2011.01.008 · DOI
  41. Scheres, 2012, Prevention of overfitting in cryo-EM structure determination, Nature Methods, 9, 853, 10.1038/nmeth.2115 · DOI · Paper page
  42. Conway, 1997, Visualization of a 4-helix bundle in the hepatitis B virus capsid by cryo-electron microscopy, Nature, 386, 91, 10.1038/386091a0 · DOI · Paper page
  43. Elmlund, 2010, Ab initio structure determination from electron microscopic images of single molecules coexisting in different functional states, Structure, 18, 777, 10.1016/j.str.2010.06.001 · DOI
  44. Elmlund, 2008, A new cryo-EM single-particle ab initio reconstruction method visualizes secondary structure elements in an ATP-fueled AAA+ motor, Journal of Molecular Biology, 375, 934, 10.1016/j.jmb.2007.11.028 · DOI
  45. Elmlund, 2009, High-resolution single-particle orientation refinement based on spectrally self-adapting common lines, Journal of Structural Biology, 167, 83, 10.1016/j.jsb.2009.04.009 · DOI
  46. Dugdale, 2010, Role of Met-542 as a guide for the conformational changes of Phe-601 that occur during the reaction of beta-galactosidase (Escherichia coli), Biochemistry and Cell Biology, 88, 861, 10.1139/O10-009 · DOI
  47. Smith, 1999, XIMDISP—A visualization tool to aid structure determination from electron microscope images, Journal of Structural Biology, 125, 223, 10.1006/jsbi.1998.4073 · DOI
  48. Mindell, 2003, Accurate determination of local defocus and specimen tilt in electron microscopy, Journal of Structural Biology, 142, 334, 10.1016/S1047-8477(03)00069-8 · DOI · Paper page
  49. Crowther, 1996, MRC image processing programs, Journal of Structural Biology, 116, 9, 10.1006/jsbi.1996.0003 · DOI · Paper page
  50. Scheres, 2008, Image processing for electron microscopy single-particle analysis using XMIPP, Nature Protocols, 3, 977, 10.1038/nprot.2008.62 · DOI · Paper page
  51. Sorzano, 2004, XMIPP: a new generation of an open-source image processing package for electron microscopy, Journal of Structural Biology, 148, 194, 10.1016/j.jsb.2004.06.006 · DOI · Paper page
  52. Murshudov, 2011, REFMAC5 for the refinement of macromolecular crystal structures, Acta Crystallographica Section D, 67, 355, 10.1107/S0907444911001314 · DOI · Paper page
  53. Brunger, 1992, Free R-value—a novel statistical quantity for assessing the accuracy of crystal-structures, Nature, 355, 472, 10.1038/355472a0 · DOI · Paper page
  54. Sindelar, 2011, An adaptation of the Wiener filter suitable for analyzing images of isolated single particles, Journal of Structural Biology, 176, 60, 10.1016/j.jsb.2011.06.010 · DOI
  55. Sindelar, 2012, Optimal noise reduction in 3D reconstructions of single particles using a volume-normalized filter, Journal of Structural Biology, 180, 26, 10.1016/j.jsb.2012.05.005 · DOI

Cited by

Metadata

Authors
Chen, S., McMullan, G., Faruqi, A. R., Murshudov, G. N., Short, J. M., Scheres, S. H. W., & Henderson, R.
Venue
Ultramicroscopy
Publisher
Elsevier BV
Published
2013-12
Volume
135
Pages
24-35
ISSN
0304-3991 (ISSN-L)
OpenAlex
W2054770020
Cited by
1,003
References
2
FWCI
25.87
Type
journal article
Language
en
Open access
hybrid
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.