Real-time estimation of daily physical activity intensity by a triaxial accelerometer and a gravity-removal classification algorithm
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
We have recently developed a simple algorithm for the classification of household and locomotive activities using the ratio of unfiltered to filtered synthetic acceleration (gravity-removal physical activity classification algorithm, GRPACA) measured by a triaxial accelerometer. The purpose of the present study was to develop a new model for the immediate estimation of daily physical activity intensities using a triaxial accelerometer. A total of sixty-six subjects were randomly assigned into validation (n 44) and cross-validation (n 22) groups. All subjects performed fourteen activities while wearing a triaxial accelerometer in a controlled laboratory setting. During each activity, energy expenditure was measured by indirect calorimetry, and physical activity intensities were expressed as metabolic equivalents (MET). The validation group displayed strong relationships between measured MET and filtered synthetic accelerations for household (r 0·907, P < 0·001) and locomotive (r 0·961, P < 0·001) activities. In the cross-validation group, two GRPACA-based linear regression models provided highly accurate MET estimation for household and locomotive activities. Results were similar when equations were developed by non-linear regression or sex-specific linear or non-linear regressions. Sedentary activities were also accurately estimated by the specific linear regression classified from other activity counts. Therefore, the use of a triaxial accelerometer in combination with a GRPACA permits more accurate and immediate estimation of daily physical activity intensities, compared with previously reported cut-off classification models. This method may be useful for field investigations as well as for self-monitoring by general users.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Trumbo, P., Schlicker, S., Yates, A. A., & Poos, M. (2002) · Journal of the American Dietetic Association · doi:10.1016/s0002-8223(02)90346-9 · Cited by 5,993
New methods for calculating metabolic rate with special reference to protein metabolism
Weir, J. B. D. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004363 · Cited by 5,603
Using Pedometers to Increase Physical Activity and Improve Health: A Systematic Review
Bravata, D. M., Smith-Spangler, C., Sundaram, V., Gienger, A. L., Lin, N., Lewis, R., Stave, C. D., Olkin, I., & Sirard, J. R. (2007) · JAMA · doi:10.1001/jama.298.19.2296 · Cited by 2,064 · cited 1×
“Furthermore, activity monitors such as accelerometers or pedometers may serve as useful tools for promoting active life behaviour((11,12)).”
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
Jetté, M., Sidney, K., & Blümchen, G. (1990) · Clinical Cardiology · doi:10.1002/clc.4960130809 · Cited by 1,501
Role of Nonexercise Activity Thermogenesis in Resistance to Fat Gain in Humans
Levine, J. A., Eberhardt, N. L., & Jensen, M. D. (1999) · Science · doi:10.1126/science.283.5399.212 · Cited by 997 · cited 4×
“sity following a long period of data collection; (2) our measuring device is secured to the waist by a clip only; (3) the Douglas bag method, not a portable analyser, was used as the reference method; (4) MET were calculated with”
InfluentialThe Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Saris, W. H. M., Blair, S. N., Van Baak, M. A., Eaton, S. B., Davies, P. S. W., Di Pietro, L., Fogelholm, M., Rissanen, A., Schoeller, D., Swinburn, B., et al. (2003) · Obesity Reviews · doi:10.1046/j.1467-789x.2003.00101.x · Cited by 865
Accelerometer Use in Physical Activity: Best Practices and Research Recommendations
WARD, D. S., EVENSON, K. R., VAUGHN, A., RODGERS, A. B., & TROIANO, R. P. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185292.71933.91 · Cited by 779
Interindividual variation in posture allocation: possible role in human obesity
Levine, J. A., Lanningham-Foster, L. M., McCrady, S. K., Krizan, A. C., Olson, L. R., Kane, P. H., Jensen, M. D., & Clark, M. M. (2005) · Science · doi:10.1126/science.1106561 · Cited by 705 · cited 2×
“sity following a long period of data collection; (2) our measuring device is secured to the waist by a clip only; (3) the Douglas bag method, not a portable analyser, was used as the reference method; (4) MET were calculated with”
Physical Activity Assessments for Health-Related Research
Welk, G. J. (2002) · Medical Entomology and Zoology · Cited by 688
Calibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 659
Metabolic equivalent: one size does not fit all
Byrne, N. M., Hills, A. P., Hunter, G. R., Weinsier, R. L., & Schutz, Y. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00023.2004 · Cited by 527
Validity of four motion sensors in measuring moderate intensity physical activity
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00006 · Cited by 527
A Meta-Analysis of Pedometer-Based Walking Interventions and Weight Loss
Richardson, C. R., Newton, T. L., Abraham, J. J., Sen, A., Jimbo, M., & Swartz, A. M. (2008) · The Annals of Family Medicine · doi:10.1370/afm.761 · Cited by 421
Validation of the COSMED K4 b2 Portable Metabolic System
McLaughlin, J. E., King, G. A., Howley, E. T., Bassett, Jr., & Ainsworth, B. E. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-13816 · Cited by 374
Classifying household and locomotive activities using a triaxial accelerometer
Oshima, Y., Kawaguchi, K., Tanaka, S., Ohkawara, K., Hikihara, Y., Ishikawa-Takata, K., & Tabata, I. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.01.005 · Cited by 371
Self-citationEstimating energy expenditure using accelerometers
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0307-5 · Cited by 366
Staudenmayer, J., Pober, D., Crouter, S., Bassett, D., & Freedson, P. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00465.2009 · Cited by 361
A novel method for using accelerometer data to predict energy expenditure
Crouter, S. E., Clowers, K. G., & Bassett, D. R. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00818.2005 · Cited by 345
A comparative evaluation of three accelerometry-based physical activity monitors
WELK, G. J., BLAIR, S. N., WOOD, K., JONES, S., & THOMPSON, R. W. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00008 · Cited by 343
Measurement of Human Daily Physical Activity
Zhang, K., Werner, P., Sun, M., Pi‐Sunyer, F. X., & Boozer, C. N. (2003) · Obesity Research · doi:10.1038/oby.2003.7 · Cited by 306
Pattern and intensity of physical activity
Westerterp, K. R. (2001) · Nature · doi:10.1038/35069142 · Cited by 263
Accuracy and reliability of a Cosmed K4b2 portable gas analysis system
Duffield, R., Dawson, B., Pinnington, H. C., & Wong, P. (2004) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(04)80039-2 · Cited by 246
Accuracy of the Actiheart for the assessment of energy expenditure in adults
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2008) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602766 · Cited by 236
Physical activity assessment: A review of methods
Melanson, E. L., Freedson, P. S., & Blair, S. (1996) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408399609527732 · Cited by 223
Estimating activity energy expenditure: how valid are physical activity questionnaires?
Neilson, H. K., Robson, P. J., Friedenreich, C. M., & Csizmadi, I. (2008) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/87.2.279 · Cited by 212
Improving energy expenditure estimation by using a triaxial accelerometer
Chen, K. Y., & Sun, M. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.6.2112 · Cited by 211
Development of Novel Techniques to Classify Physical Activity Mode Using Accelerometers
POBER, D. M., STAUDENMAYER, J., RAPHAEL, C., & FREEDSON, P. S. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000227542.43669.45 · Cited by 210
Bonomi, A. G., Plasqui, G., Goris, A. H. C., & Westerterp, K. R. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00150.2009 · Cited by 196
Refined Two-Regression Model for the ActiGraph Accelerometer
CROUTER, S. E., KUFFEL, E., HAAS, J. D., FRONGILLO, E. A., & BASSETT, D. R. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181c37458 · Cited by 176
Validity of Physical Activity Intensity Predictions by ActiGraph, Actical, and RT3 Accelerometers
Rothney, M. P., Schaefer, E. V., Neumann, M. M., Choi, L., & Chen, K. Y. (2008) · Obesity · doi:10.1038/oby.2008.279 · Cited by 175
An artificial neural network model of energy expenditure using nonintegrated acceleration signals
Rothney, M. P., Neumann, M., Béziat, A., & Chen, K. Y. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00429.2007 · Cited by 144
Comparison of Two Methods to Assess PAEE during Six Activities in Children
CORDER, K., BRAGE, S., MATTOCKS, C., NESS, A., RIDDOCH, C., WAREHAM, N. J., & EKELUND, U. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318150dff8 · Cited by 96
Triaxial Accelerometry for Assessment of Physical Activity in Young Children
Tanaka, C., Tanaka, S., Kawahara, J., & Midorikawa, T. (2007) · Obesity · doi:10.1038/oby.2007.145 · Cited by 79
Self-citationA new 2-regression model for the Actical accelerometer
Crouter, S. E., & Bassett, D. R. (2008) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.033399 · Cited by 76
Energy Expenditure Estimated by Accelerometry and Doubly Labeled Water: Do They Agree?
LEENDERS, N. Y., SHERMAN, W. M., & NAGARAJA, H. N. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000235883.94357.95 · Cited by 73
A New Device to Estimate V˙O2 during Incline Walking by Accelerometry and Barometry
YAMAZAKI, T., Genno, H., Kamijo, Y., Okazaki, K., Masuki, S., & Nosé, H. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181a9c452 · Cited by 66
Evaluation of Low‐Intensity Physical Activity by Triaxial Accelerometry
Midorikawa, T., Tanaka, S., Kaneko, K., Koizumi, K., Ishikawa‐Takata, K., Futami, J., & Tabata, I. (2007) · Obesity · doi:10.1038/oby.2007.361 · Cited by 59
Self-citationAssessment of the Aerosport TEEM 100 Portable Metabolic Measurement System
WIDEMAN, L., STOUDEMIRE, N. M., PASS, K. A., McGINNES, C. L., GAESSER, G. A., & WELTMAN, A. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199604000-00017 · Cited by 56
Maiolo, C., Melchiorri, G., Iacopino, L., Masala, S. A., & LORENZO, A. D. (2003) · British Journal of Sports Medicine · doi:10.1136/bjsm.37.5.445 · Cited by 49
Reliability and Validity of a Portable Metabolic Measurement System
Melanson, E. L., Freedson, P. S., Hendelman, D., & Debold, E. (1996) · Canadian Journal of Applied Physiology · doi:10.1139/h96-010 · Cited by 39
Ohkawara, K., Tanaka, S., Ishikawa‐Takata, K., & Tabata, I. (2008) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/87.5.1268 · Cited by 33
Self-citationLITTLEWOOD, R. (2002) · Clinical Nutrition · doi:10.1054/clnu.2002.0580 · Cited by 30
(2005) · PubMed
Cited by
DiPietro, L., Al-Ansari, S. S., Biddle, S. J. H., Borodulin, K., Bull, F. C., Buman, M. P., Cardon, G., Carty, C., Chaput, J.-P., Chastin, S., et al. (2020) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-020-01042-2 · Cited by 387
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Applying machine learning to predict future adherence to physical activity programs
Zhou, M., Fukuoka, Y., Goldberg, K., Vittinghoff, E., & Aswani, A. (2019) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-019-0890-0 · Cited by 45
Different Location of Triaxial Accelerometer and Different Energy Expenditures
Kim, D. Y., Jung, Y.-S., Park, R.-W., & Joo, N.-S. (2014) · Yonsei Medical Journal · doi:10.3349/ymj.2014.55.4.1145 · Cited by 34
Metadata
- Authors
- Ohkawara, K., Oshima, Y., Hikihara, Y., Ishikawa-Takata, K., Tabata, I., & Tanaka, S.
- Venue
- British Journal of Nutrition
- Publisher
- Cambridge University Press (CUP)
- Published
- 2011-01-25
- Volume
- 105
- Issue
- 11
- Pages
- 1681-1691
- ISSN
- 0007-1145 (ISSN-L)
- 1475-2662
- OpenAlex
- W1964754398
- Cited by
- 458
- References
- 46
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.