The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Ferrocene-mediated enzyme electrode for amperometric determination of glucose
Abstract
ADVERTISEMENT RETURN TO ISSUEPREVArticleNEXTFerrocene-mediated enzyme electrode for amperometric determination of glucoseAnthony E. G. Cass, Graham. Davis, Graeme D. Francis, H. Allen O. Hill, William J. Aston, I. John. Higgins, Elliot V. Plotkin, Lesley D. L. Scott, and Anthony P. F. TurnerCite this: Anal. Chem. 1984, 56, 4, 667–671Publication Date (Print):April 1, 1984Publication History Published online1 May 2002Published inissue 1 April 1984https://pubs.acs.org/doi/10.1021/ac00268a018https://doi.org/10.1021/ac00268a018research-articleACS PublicationsRequest reuse permissionsArticle Views8874Altmetric-Citations1386LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts.The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on the Altmetric Attention Score and how the score is calculated. Share Add toView InAdd Full Text with ReferenceAdd Description ExportRISCitationCitation and abstractCitation and referencesMore Options Share onFacebookTwitterWechatLinked InRedditEmail Other access optionsGet e-Alertsclose Get e-Alerts
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Determination of Enzyme Dissociation Constants
Lineweaver, H., & Burk, D. (1934) · Journal of the American Chemical Society · doi:10.1021/ja01318a036 · Cited by 12,060
Nicholson, R. S., & Shain, I. (1964) · Analytical Chemistry · doi:10.1021/ac60210a007 · Cited by 5,097
Weibel, M. K., & Bright, H. J. (1971) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)62246-x · Cited by 349
Urease coupled ammonia electrode for urea determination in blood serum
Mascini, M., & Guilbault, G. G. (1977) · Analytical Chemistry · doi:10.1021/ac50014a031 · Cited by 151
Electrochemical measurement of glucose using various electron acceptors
Schläpfer, P., Mindt, W., & Racine, P. (1974) · Clinica Chimica Acta · doi:10.1016/0009-8981(74)90408-2 · Cited by 84
Theoretical evaluation of the steady-state response of potentiometric enzyme electrodes
Brady, J. E., & Carr, P. W. (1980) · Analytical Chemistry · doi:10.1021/ac50056a046 · Cited by 66
Hill, H. A. O., & Walton, N. J. (1982) · Journal of the American Chemical Society · doi:10.1021/ja00388a006 · Cited by 59
Self-citation
Cited by
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
A Review on Biosensors and Recent Development of Nanostructured Materials-Enabled Biosensors
Naresh, V., & Lee, N. (2021) · Sensors · doi:10.3390/s21041109 · Cited by 2,066
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Glucose oxidase: an ideal enzyme
Wilson, R., & Turner, A. P. F. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)87013-f · Cited by 1,350
Self-citationBhalla, N., Jolly, P., Formisano, N., & Estrela, P. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150001 · Cited by 1,312
Electrochemical non-enzymatic glucose sensors
Park, S., Boo, H., & Chung, T. D. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.05.080 · Cited by 1,159
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
Enzymes as Working or Inspirational Electrocatalysts for Fuel Cells and Electrolysis
Cracknell, J. A., Vincent, K. A., & Armstrong, F. A. (2008) · Chemical Reviews · doi:10.1021/cr0680639 · Cited by 988
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation
Toghill, K. E., & Compton, R. G. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15359-4 · Cited by 926
Home blood glucose biosensors: a commercial perspective
Newman, J. D., & Turner, A. P. F. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.012 · Cited by 900
Self-citationEnzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Chaubey, A., & Malhotra, B. D. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00313-x · Cited by 777
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Glucose Biosensors: 40 Years of Advances and Challenges
Wang, J. (2001) · Electroanalysis · doi:10.1002/1521-4109(200108)13:12<983::aid-elan983>3.0.co;2-# · Cited by 752
Why is Ferrocene so Exceptional?
Astruc, D. (2017) · European Journal of Inorganic Chemistry · doi:10.1002/ejic.201600983 · Cited by 653
Immobilization of glucose oxidase in ferrocene-modified pyrrole polymers
Foulds, N. C., & Lowe, C. R. (1988) · Analytical Chemistry · doi:10.1021/ac00173a008 · Cited by 613
Protein-modified electrodes. The glucose oxidase/polypyrrole system
Umana, M., & Waller, J. (1986) · Analytical Chemistry · doi:10.1021/ac00127a018 · Cited by 588
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
Self-citationMalitesta, C., Palmisano, F., Torsi, L., & Zambonin, P. G. (1990) · Analytical Chemistry · doi:10.1021/ac00223a016 · Cited by 570
Liu, Y., Wang, M., Zhao, F., Xu, Z., & Dong, S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.03.003 · Cited by 552
A Critical Review of Glucose Biosensors Based on Carbon Nanomaterials: Carbon Nanotubes and Graphene
Zhu, Z., Garcia-Gancedo, L., Flewitt, A. J., Xie, H., Moussy, F., & Milne, W. I. (2012) · Sensors · doi:10.3390/s120505996 · Cited by 549
Biosensors in clinical chemistry
D'Orazio, P. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00241-9 · Cited by 524
Carbon paste electrodes modified with enzymes, tissues, and cells
Gorton, L. (1995) · Electroanalysis · doi:10.1002/elan.1140070104 · Cited by 515
Electrochemical analysis of the interactions of laccase mediators with lignin model compounds
Bourbonnais, R., Leech, D., & Paice, M. G. (1998) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/s0304-4165(97)00117-7 · Cited by 493
Fundamentals, Applications, and Future Directions of Bioelectrocatalysis
Chen, H., Simoska, O., Lim, K., Grattieri, M., Yuan, M., Dong, F., Lee, Y. S., Beaver, K., Weliwatte, S., Gaffney, E. M., et al. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00472 · Cited by 492
Enzymatic biofuel cells: 30 years of critical advancements
Rasmussen, M., Abdellaoui, S., & Minteer, S. D. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.029 · Cited by 483
Silver, I., & Erecinska, M. (1994) · The Journal of Neuroscience · doi:10.1523/jneurosci.14-08-05068.1994 · Cited by 477
A review of the immobilization of enzymes in electropolymerized films
Barlett, P. N., & Cooper, J. M. (1993) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)80001-x · Cited by 472
Liu, S., & Ju, H. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00172-6 · Cited by 471
Enzymatic fuel cells: Recent progress
Leech, D., Kavanagh, P., & Schuhmann, W. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.02.087 · Cited by 446
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Electrochemical biosensors and nanobiosensors
Hammond, J. L., Formisano, N., Estrela, P., Carrara, S., & Tkac, J. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150008 · Cited by 425
Ohara, T. J., Rajagopalan, R., & Heller, A. (1994) · Analytical Chemistry · doi:10.1021/ac00087a008 · Cited by 379
Swager, T. M. (2017) · Macromolecules · doi:10.1021/acs.macromol.7b00582 · Cited by 375
Prospects of conducting polymers in biosensors
Malhotra, B. D., Chaubey, A., & Singh, S. P. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.04.055 · Cited by 372
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
Nanomaterials for electrochemical non-enzymatic glucose biosensors
Si, P., Huang, Y., Wang, T., & Ma, J. (2013) · RSC Advances · doi:10.1039/c2ra22360k · Cited by 364
Ricci, F., Amine, A., Palleschi, G., & Moscone, D. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00169-0 · Cited by 349
Electrochemical Sensors, Biosensors and their Biomedical Applications
(2008) · Elsevier eBooks · doi:10.1016/b978-0-12-373738-0.x5001-6 · Cited by 333
Implications of Nanobiosensors in Agriculture
Rai, V., Acharya, S., & Dey, N. (2012) · Journal of Biomaterials and Nanobiotechnology · doi:10.4236/jbnb.2012.322039 · Cited by 332
Malhotra, B. D., & Ali, M. A. (2018) · Nanomaterials for Biosensors · doi:10.1016/b978-0-323-44923-6.00001-7 · Cited by 319
Three-dimensional network films of electrospun copper oxide nanofibers for glucose determination
Wang, W., Zhang, L., Tong, S., Li, X., & Song, W. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.08.013 · Cited by 310
Diagnostic biosensors in medicine – A review
Metkar, S. K., & Girigoswami, K. (2019) · Biocatalysis and Agricultural Biotechnology · doi:10.1016/j.bcab.2018.11.029 · Cited by 304
Current research activity in biosensors
Nakamura, H., & Karube, I. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1947-5 · Cited by 299
Organic Electronics at the Interface with Biology
Owens, R. M., & Malliaras, G. G. (2010) · MRS Bulletin · doi:10.1557/mrs2010.583 · Cited by 294
Direct electron transfer at horseradish peroxidase—colloidal gold modified electrodes
Zhao, J., Henkens, R. W., Stonehuerner, J., O'Daly, J. P., & Crumbliss, A. L. (1992) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(92)80140-y · Cited by 293
Materials and techniques for electrochemical biosensor design and construction
Zhang, S. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00076-2 · Cited by 286
Karyakin, A. A., & Karyakina, E. E. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(99)00154-9 · Cited by 283
Hart, J. P., & Wring, S. A. (1997) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(96)00097-0 · Cited by 280
Castillo, J., Gáspár, S., Leth, S., Niculescu, M., Mortari, A., Bontidean, I., Soukharev, V., Dorneanu, S. A., Ryabov, A. D., & Csöregi, E. (2004) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2004.04.084 · Cited by 272
Leskovac, V., Trivić, S., Wohlfahrt, G., Kandrač, J., & Peričin, D. (2005) · The International Journal of Biochemistry & Cell Biology · doi:10.1016/j.biocel.2004.10.014 · Cited by 271
Electrochemistry in Diabetes Management
Heller, A., & Feldman, B. (2010) · Accounts of Chemical Research · doi:10.1021/ar9002015 · Cited by 255
Cui, H.-F., Ye, J.-S., Zhang, W.-D., Li, C.-M., Luong, J. H. T., & Sheu, F.-S. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.05.047 · Cited by 254
Implanted Electrochemical Glucose Sensors for the Management of Diabetes
Heller, A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.153 · Cited by 215
In-Vivo Electrochemistry: What Can We Learn about Living Systems?
Wilson, G. S., & Johnson, M. A. (2008) · Chemical Reviews · doi:10.1021/cr068082i · Cited by 178
Ngoepe, M., Choonara, Y., Tyagi, C., Tomar, L., Du Toit, L., Kumar, P., Ndesendo, V., & Pillay, V. (2013) · Sensors · doi:10.3390/s130607680 · Cited by 92
Bringing inorganic chemistry to life with inspiration from R. J. P. Williams
Hill, H. A. O., & Sadler, P. J. (2016) · JBIC Journal of Biological Inorganic Chemistry · doi:10.1007/s00775-016-1333-3 · Cited by 17
Self-citation
Metadata
- Authors
- Cass, A. E. G., Davis, G., Francis, G. D., Hill, H. A. O., Aston, W. J., Higgins, I. J., Plotkin, E. V., Scott, L. D. L., & Turner, A. P. F.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1984-04-01
- Volume
- 56
- Issue
- 4
- Pages
- 667-671
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2043324182
- Cited by
- 1,646
- References
- 7
- FWCI
- 43.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.