The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Use of Ionic Liquids for Liquid-Phase Microextraction of Polycyclic Aromatic Hydrocarbons
Open accessAbstract
This paper demonstrates, for the first time, that ionic liquids (IL) such as 1-octyl-3-methylimidazolium hexafluorophosphate ([C(8)MIM][PF(6)]) are excellent extraction solvents in liquid-phase microextraction (LPME). The unique properties of nonvolatility and adequate viscosity allow IL to be conveniently adopted as extraction solvents in both direct-immersion and headspace LPME. Model compounds, polycyclic aromatic hydrocarbons (PAHs), are conveniently and rapidly enriched in a 3-microL drop of [C(8)MIM][PF(6)] suspended on the tip of a microsyringe followed by liquid chromatographic determination. Compared to 1-octanol, a larger volume drop of [C(8)MIM][PF(6)] can be formed and survive for a longer extraction time; therefore, a much higher enrichment factor for PAHs can be reached. For low-volatility PAHs, direct-immersion LPME provides higher enrichment factors than that of headspace LPME. However, the enrichment factor obtained by headspace LPME was almost 3-fold of that by direct-immersion LPME in a 30-min extraction of the most volatile PAH, naphthalene. For 30-min direction-immersion LPME of EPA priority PAHs, the enrichment factor, correlation coefficient (R(2)), and reproducibility (RSD, n = 5) were in the range of 42-166, 0.9169-0.9976, and 2.8-12%, respectively. Considering that IL can be easily prepared from relatively inexpensive materials and tuned by combination of different anions and cations for task-specific extraction of analytes from various solvent media, this proposed method should have great potentiality in sample preparation. Furthermore, the nonvolatility of IL makes it potentially useful for headspace LPME of volatile analytes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Research works printed but not linked: 43
- Welton T., 1999, Chem. Rev., 99, 2083, 10.1021/cr980032t · DOI · Paper page
- Wilkes J. S., 1992, J. Chem. Soc., Chem. Commun., 965, 967
- Huddleston J. G., 1998, Chem. Commun., 1765, 1766
- Fadeev A. G., 2001, Chem. Commun., 295, 296
- Visser A. E., 2001, Chem. Commun., 135, 136
- Blanchard L. A., 1999, Nature, 399, 29, 10.1038/19887 · DOI
- Brown R. A., 2001, J. Am. Chem. Soc., 123, 1255
- Boesmann A., 2001, Angew. Chem., Int. Ed., 40, 2699
- Schafer T., 2001, Chem. Commun., 1622, 1623
- Armstrong D. W., 1999, Anal. Chem., 71, 3876
- Armstrong D. W., 2002, J. Am. Chem. Soc., 124, 14254
- Branco L. C., 2002, Angew. Chem., Int. Ed., 41, 2773, 10.1002/1521-3773(20020802)41:15<2771::AID-ANIE2771>3.0.CO;2-U · DOI
- Visser A. E., 2002, Environ. Sci. Technol., 36, 2529, 10.1021/es0158004 · DOI
- Huddleston J. G., 2001, Green Chem., 3, 164, 10.1039/b103275p · DOI
- Abraham M. H., 2003, Ind. Eng. Chem. Res., 42, 418, 10.1021/ie020520y · DOI
- Carda-Broch S., 2003, Anal. Bioanal. Chem., 375, 199, 10.1007/s00216-002-1684-1 · DOI
- Shetty P. H., 1987, J. Chromatogr., 411, 79, 10.1016/S0021-9673(00)93960-8 · DOI
- Berthod A., 2000, Chromatographia, 53, 68
- Armstrong D. W., 2001, Anal. Chem., 73, 3686
- Yanes E. G., 2001, Anal. Chem., 73, 3844, 10.1021/ac010263r · DOI · Paper page
- Vaher M., 2001, Chromatographia, 53, 306, 10.1007/BF02490346 · DOI
- Vaher M., 2002, Electrophoresis, 23, 430, 10.1002/1522-2683(200202)23:3<426::AID-ELPS426>3.0.CO;2-8 · DOI
- Qin W., 2003, Analyst, 128, 41
- Chun S., 2001, Anal. Chem., 73, 3741, 10.1021/ac010061v · DOI
- Liu S., 1995, Anal. Chem., 67, 2049
- Cardoso A. A., 1995, Anal. Chem., 67, 2566, 10.1021/ac00111a011 · DOI
- Jeannot M. A., 1997, Anal. Chem., 69, 239
- He Y., 1997, Anal. Chem., 69, 4640
- Wang Y., 1998, Anal. Chem., 70, 4614
- Ma M. H., 1998, Anal. Chem., 70, 3919
- Ma M. H., 1999, Anal. Chem., 71, 393
- Genfa Z., 2000, Anal. Chem., 72, 3170, 10.1021/ac000069p · DOI
- Theis A. L., 2001, Anal. Chem., 73, 5654, 10.1021/ac015569c · DOI · Paper page
- Pedersen-Bjergaard S., 1999, Anal. Chem., 71, 2656, 10.1021/ac990055n · DOI · Paper page
- Zhao L., 2002, Anal. Chem., 74, 2486, 10.1021/ac011124c · DOI
- Shen G., 2003, Anal. Chem., 75, 103
- Varma R. S., 2001, Chem. Commun., 643, 644
- Visser A. E., 2000, Ind. Eng. Chem. Res., 39, 3604, 10.1021/ie000426m · DOI · Paper page
- Anthony J. L., 2001, J. Phys. Chem. B, 105, 10949, 10.1021/jp0112368 · DOI · Paper page
- Law G., 2001, Langmuir, 17, 6141
- Seddon K. R., 2000, Pure Appli. Chem., 72, 2287
- Florence T. M., 1971, J. Anal. Chim. Acta, 54, 377, 10.1016/S0003-2670(01)82142-5 · DOI
- Marce R. M., 2000, J. Chromatogr., A, 885, 290, 10.1016/S0021-9673(00)00428-3 · DOI
Cited by
Sarafraz-Yazdi, A., & Amiri, A. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.10.003 · Cited by 779
Ionic liquids in analytical chemistry
Sun, P., & Armstrong, D. W. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.12.007 · Cited by 727
Extraction of organic compounds with room temperature ionic liquids
Poole, C. F., & Poole, S. K. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.011 · Cited by 493
Ionic liquids and deep eutectic mixtures: Sustainable solvents for extraction processes
Pena‐Pereira, F., & Namieśnik, J. (2014) · ChemSusChem · doi:10.1002/cssc.201301192 · Cited by 432
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Chen, Y., Guo, Z., Wang, X., & Qiu, C. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.026 · Cited by 316
Temperature-controlled ionic liquid dispersive liquid phase micro-extraction
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.103 · Cited by 303
Self-citationLiu, Y., Zhao, E., Zhu, W., Gao, H., & Zhou, Z. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.11.076 · Cited by 301
Peng, J.-F., Liu, J.-F., Hu, X.-L., & Jiang, G.-B. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.11.006 · Cited by 276
Self-citationRecent advances and trends in miniaturized sample preparation techniques
Soares da Silva Burato, J., Vargas Medina, D. A., de Toffoli, A. L., Vasconcelos Soares Maciel, E., & Mauro Lanças, F. (2020) · Journal of Separation Science · doi:10.1002/jssc.201900776 · Cited by 254
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.094 · Cited by 248
Self-citationLiquid-phase microextraction techniques within the framework of green chemistry
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.02.016 · Cited by 221
Yao, C., & Anderson, J. L. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3078-0 · Cited by 204
The roles of ionic liquids in sorptive microextraction techniques
Aguilera-Herrador, E., Lucena, R., Cárdenas, S., & Valcárcel, M. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.11.009 · Cited by 171
Yao, C., Pitner, W. R., & Anderson, J. L. (2009) · Analytical Chemistry · doi:10.1021/ac900719m · Cited by 167
Ravelo-Pérez, L. M., Hernández-Borges, J., Asensio-Ramos, M., & Rodríguez-Delgado, M. Á. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.08.012 · Cited by 156
One-step in-syringe ionic liquid-based dispersive liquid–liquid microextraction
Cruz-Vera, M., Lucena, R., Cárdenas, S., & Valcárcel, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.07.040 · Cited by 154
Pena-Pereira, F., Lavilla, I., Bendicho, C., Vidal, L., & Canals, A. (2009) · Talanta · doi:10.1016/j.talanta.2008.12.003 · Cited by 143
López-Darias, J., Germán-Hernández, M., Pino, V., & Afonso, A. M. (2010) · Talanta · doi:10.1016/j.talanta.2009.09.057 · Cited by 142
Ionic liquids in the microextraction techniques: The influence of ILs structure and properties
Yavir, K., Konieczna, K., Marcinkowski, Ł., & Kloskowski, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115994 · Cited by 134
Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems
An, J., Trujillo-Rodríguez, M. J., Pino, V., & Anderson, J. L. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.04.012 · Cited by 128
Stanisz, E., Werner, J., & Zgoła-Grześkowiak, A. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.06.008 · Cited by 116
Chisvert, A., Román, I. P., Vidal, L., & Canals, A. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.12.078 · Cited by 112
Modern solutions in the field of microextraction using liquid as a medium of extraction
Płotka-Wasylka, J., Owczarek, K., & Namieśnik, J. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.08.010 · Cited by 109
Application of ionic liquid in liquid phase microextraction technology
Han, D., Tang, B., Ri Lee, Y., & Ho Row, K. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200486 · Cited by 103
Liu, J., Chi, Y., & Jiang, G. (2005) · Journal of Separation Science · doi:10.1002/jssc.200401805 · Cited by 84
Self-citationIonic liquids in microextraction techniques
Vičkačkaitė, V., & Padarauskas, A. (2012) · Open Chemistry · doi:10.2478/s11532-012-0023-4 · Cited by 84
Opportunities and shortcomings of ionic liquids in single-drop microextraction
Marcinkowski, Ł., Pena-Pereira, F., Kloskowski, A., & Namieśnik, J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.03.024 · Cited by 69
Bai, H., Zhou, Q., Xie, G., & Xiao, J. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.08.011 · Cited by 67
Self-citationLiquid-phase microextraction of polycyclic aromatic hydrocarbons: A review
Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020) · Reviews in Analytical Chemistry · doi:10.1515/revac-2020-0101 · Cited by 50
Application of ionic liquids for liquid–liquid microextraction
Zhang, P., Hu, L., Lu, R., Zhou, W., & Gao, H. (2013) · Analytical Methods · doi:10.1039/c3ay40597d · Cited by 50
A ionic liquid for dispersive liquid-liquid microextraction of phenols
Fan, Y. C., Chen, M. L., Shen-Tu, C., & Zhu, Y. (2009) · Journal of Analytical Chemistry · doi:10.1134/s1061934809100074 · Cited by 43
Single-Drop Microextraction in Bioanalysis
Choi, K., Kim, J., & Chung, D. S. (2011) · Bioanalysis · doi:10.4155/bio.11.3 · Cited by 42
Zhou, Q., Zhang, X., Xie, G., & Xiao, J. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900444 · Cited by 33
Self-citationGreening Sample Preparation: New Solvents, New Sorbents
Ramos, L. (2020) · Challenges in Green Analytical Chemistry · doi:10.1039/9781788016148-00114 · Cited by 6
Olomukoro, A. A., Eitzmann, D. R., Anderson, J. L., & Gionfriddo, E. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c06522 · Cited by 6
Metadata
- Authors
- Liu, J.-F., Jiang, G.-B., Chi, Y.-G., Cai, Y.-Q., Zhou, Q.-X., & Hu, J.-T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-09-04
- Volume
- 75
- Issue
- 21
- Pages
- 5870-5876
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2077704724
- Cited by
- 484
- References
- 1
- FWCI
- 15.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.