The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Abstract
This paper describes a procedure that makes it possible to design and fabricate (including sealing) microfluidic systems in an elastomeric material [Formula: see text] poly(dimethylsiloxane) (PDMS) [Formula: see text] in less than 24 h. A network of microfluidic channels (with width >20 μm) is designed in a CAD program. This design is converted into a transparency by a high-resolution printer; this transparency is used as a mask in photolithography to create a master in positive relief photoresist. PDMS cast against the master yields a polymeric replica containing a network of channels. The surface of this replica, and that of a flat slab of PDMS, are oxidized in an oxygen plasma. These oxidized surfaces seal tightly and irreversibly when brought into conformal contact. Oxidized PDMS also seals irreversibly to other materials used in microfluidic systems, such as glass, silicon, silicon oxide, and oxidized polystyrene; a number of substrates for devices are, therefore, practical options. Oxidation of the PDMS has the additional advantage that it yields channels whose walls are negatively charged when in contact with neutral and basic aqueous solutions; these channels support electroosmotic pumping and can be filled easily with liquids with high surface energies (especially water). The performance of microfluidic systems prepared using this rapid prototyping technique has been evaluated by fabricating a miniaturized capillary electrophoresis system. Amino acids, charge ladders of positively and negatively charged proteins, and DNA fragments were separated in aqueous solutions with this system with resolution comparable to that obtained using fused silica capillaries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaudhury, M. K., & Whitesides, G. M. (1991) · Langmuir · doi:10.1021/la00053a033 · Cited by 658
Self-citation
Cited by
Items 101–142 of 142
Recent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277
DC-Dielectrophoretic separation of biological cells by size
Kang, Y., Li, D., Kalams, S. A., & Eid, J. E. (2008) · Biomedical Microdevices · doi:10.1007/s10544-007-9130-y · Cited by 276
Aptamer-Based Microfluidic Device for Enrichment, Sorting, and Detection of Multiple Cancer Cells
Xu, Y., Phillips, J. A., Yan, J., Li, Q., Fan, Z. H., & Tan, W. (2009) · Analytical Chemistry · doi:10.1021/ac9012072 · Cited by 275
van Midwoud, P. M., Janse, A., Merema, M. T., Groothuis, G. M. M., & Verpoorte, E. (2012) · Analytical Chemistry · doi:10.1021/ac300771z · Cited by 274
Prototyping of Microfluidic Devices in Poly(dimethylsiloxane) Using Solid-Object Printing
McDonald, J. C., Chabinyc, M. L., Metallo, S. J., Anderson, J. R., Stroock, A. D., & Whitesides, G. M. (2002) · Analytical Chemistry · doi:10.1021/ac010938q · Cited by 266
Self-citationBartolo, D., Degré, G., Nghe, P., & Studer, V. (2008) · Lab Chip · doi:10.1039/b712368j · Cited by 265
Single-cell deep phenotyping of IgG-secreting cells for high-resolution immune monitoring
Eyer, K., Doineau, R. C. L., Castrillon, C. E., Briseño-Roa, L., Menrath, V., Mottet, G., England, P., Godina, A., Brient-Litzler, E., Nizak, C., et al. (2017) · Nature Biotechnology · doi:10.1038/nbt.3964 · Cited by 264
Mazutis, L., Araghi, A. F., Miller, O. J., Baret, J.-C., Frenz, L., Janoshazi, A., Taly, V., Miller, B. J., Hutchison, J. B., Link, D., et al. (2009) · Analytical Chemistry · doi:10.1021/ac900403z · Cited by 263
High density 3D printed microfluidic valves, pumps, and multiplexers
Gong, H., Woolley, A. T., & Nordin, G. P. (2016) · Lab on a Chip · doi:10.1039/c6lc00565a · Cited by 263
Chuah, Y. J., Koh, Y. T., Lim, K., Menon, N. V., Wu, Y., & Kang, Y. (2015) · Scientific Reports · doi:10.1038/srep18162 · Cited by 262
Adsorption of Proteins to Hydrophobic Sites on Mixed Self-Assembled Monolayers
Ostuni, E., Grzybowski, B. A., Mrksich, M., Roberts, C. S., & Whitesides, G. M. (2003) · Langmuir · doi:10.1021/la020649c · Cited by 261
Self-citationRapid electrochemical detection on a mobile phone
Lillehoj, P. B., Huang, M.-C., Truong, N., & Ho, C.-M. (2013) · Lab on a Chip · doi:10.1039/c3lc50306b · Cited by 259
Light to Shape the Future: From Photolithography to 4D Printing
del Barrio, J., & Sánchez‐Somolinos, C. (2019) · Advanced Optical Materials · doi:10.1002/adom.201900598 · Cited by 258
Single-Molecule Cut-and-Paste Surface Assembly
Kufer, S. K., Puchner, E. M., Gumpp, H., Liedl, T., & Gaub, H. E. (2008) · Science · doi:10.1126/science.1151424 · Cited by 258
Gérard, A., Woolfe, A., Mottet, G., Reichen, M., Castrillon, C., Menrath, V., Ellouze, S., Poitou, A., Doineau, R., Briseno-Roa, L., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0466-7 · Cited by 256
Optofluidic trapping and transport on solid core waveguides within a microfluidic device
Schmidt, B. S., Yang, A. H. J., Erickson, D., & Lipson, M. (2007) · Optics Express · doi:10.1364/oe.15.014322 · Cited by 250
Yamada, M., Utoh, R., Ohashi, K., Tatsumi, K., Yamato, M., Okano, T., & Seki, M. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.07.068 · Cited by 247
Jain, A., Graveline, A., Waterhouse, A., Vernet, A., Flaumenhaft, R., & Ingber, D. E. (2016) · Nature Communications · doi:10.1038/ncomms10176 · Cited by 182
Imura, Y., Sato, K., & Yoshimura, E. (2010) · Analytical Chemistry · doi:10.1021/ac100806x · Cited by 172
The dynamic behavior of chemically “stiffened” red blood cells in microchannel flows
Forsyth, A. M., Wan, J., Ristenpart, W. D., & Stone, H. A. (2010) · Microvascular Research · doi:10.1016/j.mvr.2010.03.008 · Cited by 172
A microfluidic platform for 3-dimensional cell culture and cell-based assays
Kim, M. S., Yeon, J. H., & Park, J.-K. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9016-4 · Cited by 166
Cardiovascular organ-on-a-chip platforms for drug discovery and development
Ribas, J., Sadeghi, H., Manbachi, A., Leijten, J., Brinegar, K., Zhang, Y. S., Ferreira, L., & Khademhosseini, A. (2016) · Applied In Vitro Toxicology · doi:10.1089/aivt.2016.0002 · Cited by 161
Transient compartmentalization of RNA replicators prevents extinction due to parasites
Matsumura, S., Kun, Á., Ryckelynck, M., Coldren, F., Szilágyi, A., Jossinet, F., Rick, C., Nghe, P., Szathmáry, E., & Griffiths, A. D. (2016) · Science · doi:10.1126/science.aag1582 · Cited by 162
Assessment of whole blood thrombosis in a microfluidic device lined by fixed human endothelium
Jain, A., van der Meer, A. D., Papa, A.-L., Barrile, R., Lai, A., Schlechter, B. L., Otieno, M. A., Louden, C. S., Hamilton, G. A., Michelson, A. D., et al. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0095-6 · Cited by 148
On being the right size: scaling effects in designing a human-on-a-chip
Moraes, C., Labuz, J. M., Leung, B. M., Inoue, M., Chun, T.-H., & Takayama, S. (2013) · Integrative Biology · doi:10.1039/c3ib40040a · Cited by 134
Gomez-Sjoberg, R., Leyrat, A. A., Houseman, B. T., Shokat, K., & Quake, S. R. (2010) · Analytical Chemistry · doi:10.1021/ac101870s · Cited by 104
Organs-on-a-chip: a union of tissue engineering and microfabrication
Zhao, Y., Wang, E. Y., Lai, F. B. L., Cheung, K., & Radisic, M. (2023) · Trends in Biotechnology · doi:10.1016/j.tibtech.2022.12.018 · Cited by 93
The revolution of PDMS microfluidics in cellular biology
Banik, S., Uchil, A., Kalsang, T., Chakrabarty, S., Ali, M. A., Srisungsitthisunti, P., Mahato, K. K., Surdo, S., & Mazumder, N. (2023) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2022.2034733 · Cited by 84
Patterning alginate hydrogels using light-directed release of caged calcium in a microfluidic device
Chueh, B.-H., Zheng, Y., Torisawa, Y.-S., Hsiao, A. Y., Ge, C., Hsiong, S., Huebsch, N., Franceschi, R., Mooney, D. J., & Takayama, S. (2010) · Biomedical Microdevices · doi:10.1007/s10544-009-9369-6 · Cited by 82
Optoelectrothermic Control of Highly Integrated Polymer‐Based MEMS Applied in an Artificial Skin
Richter, A., & Paschew, G. (2009) · Advanced Materials · doi:10.1002/adma.200802737 · Cited by 74
Yu, T., Guo, Z., Fan, H., Song, J., Liu, Y., Gao, Z., & Wang, Q. (2016) · Oncotarget · doi:10.18632/oncotarget.8232 · Cited by 70
Bridging the gap: microfluidic devices for short and long distance cell–cell communication
Vu, T. Q., de Castro, R. M. B., & Qin, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01367h · Cited by 63
Titmarsh, D. M., Glass, N. R., Mills, R. J., Hidalgo, A., Wolvetang, E. J., Porrello, E. R., Hudson, J. E., & Cooper-White, J. J. (2016) · Scientific Reports · doi:10.1038/srep24637 · Cited by 59
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Monitoring in vitro thrombus formation with novel microfluidic devices
Westein, E., de Witt, S., Lamers, M., Cosemans, J. M. E. M., & Heemskerk, J. W. M. (2012) · Platelets · doi:10.3109/09537104.2012.709653 · Cited by 54
Titmarsh, D. M., Hudson, J. E., Hidalgo, A., Elefanty, A. G., Stanley, E. G., Wolvetang, E. J., & Cooper-White, J. J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0052405 · Cited by 48
Pre-patterned ZnO nanoribbons on soft substrates for stretchable energy harvesting applications
Ma, T., Wang, Y., Tang, R., Yu, H., & Jiang, H. (2013) · Journal of Applied Physics · doi:10.1063/1.4807320 · Cited by 43
In vitro micro-physiological models for translational immunology
Ramadan, Q., & Gijs, M. A. M. (2015) · Lab on a Chip · doi:10.1039/c4lc01271b · Cited by 41
Byun, D., Cho, S. J., & Kim, S. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/12/125010 · Cited by 39
Ghasemi Toudeshkchouei, M., Zahedi, P., & Shavandi, A. (2020) · Materials · doi:10.3390/ma13071483 · Cited by 39
Etezadi, F., Le, M. N. T., Shahsavarani, H., Alipour, A., Moazzezy, N., Samani, S., Amanzadeh, A., Pahlavan, S., Bonakdar, S., Shokrgozar, M. A., et al. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.2c00162 · Cited by 33
Regier, M. C., Maccoux, L. J., Weinberger, E. M., Regehr, K. J., Berry, S. M., Beebe, D. J., & Alarid, E. T. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0083-x · Cited by 23
Metadata
- Authors
- Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-10-24
- Volume
- 70
- Issue
- 23
- Pages
- 4974-4984
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2026908430
- Cited by
- 5,288
- References
- 1
- FWCI
- 47.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.