The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Abstract
This paper describes a procedure that makes it possible to design and fabricate (including sealing) microfluidic systems in an elastomeric material [Formula: see text] poly(dimethylsiloxane) (PDMS) [Formula: see text] in less than 24 h. A network of microfluidic channels (with width >20 μm) is designed in a CAD program. This design is converted into a transparency by a high-resolution printer; this transparency is used as a mask in photolithography to create a master in positive relief photoresist. PDMS cast against the master yields a polymeric replica containing a network of channels. The surface of this replica, and that of a flat slab of PDMS, are oxidized in an oxygen plasma. These oxidized surfaces seal tightly and irreversibly when brought into conformal contact. Oxidized PDMS also seals irreversibly to other materials used in microfluidic systems, such as glass, silicon, silicon oxide, and oxidized polystyrene; a number of substrates for devices are, therefore, practical options. Oxidation of the PDMS has the additional advantage that it yields channels whose walls are negatively charged when in contact with neutral and basic aqueous solutions; these channels support electroosmotic pumping and can be filled easily with liquids with high surface energies (especially water). The performance of microfluidic systems prepared using this rapid prototyping technique has been evaluated by fabricating a miniaturized capillary electrophoresis system. Amino acids, charge ladders of positively and negatively charged proteins, and DNA fragments were separated in aqueous solutions with this system with resolution comparable to that obtained using fused silica capillaries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaudhury, M. K., & Whitesides, G. M. (1991) · Langmuir · doi:10.1021/la00053a033 · Cited by 658
Self-citation
Cited by
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Self-citationBhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Self-citationFormation of droplets and bubbles in a microfluidic T-junction—scaling and mechanism of break-up
Garstecki, P., Fuerstman, M. J., Stone, H. A., & Whitesides, G. M. (2006) · Lab on a Chip · doi:10.1039/b510841a · Cited by 2,339
Self-citationDeveloping optofluidic technology through the fusion of microfluidics and optics
Psaltis, D., Quake, S. R., & Yang, C. (2006) · Nature · doi:10.1038/nature05060 · Cited by 1,733
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Self-citationUnconventional Methods for Fabricating and Patterning Nanostructures
Xia, Y., Rogers, J. A., Paul, K. E., & Whitesides, G. M. (1999) · Chemical Reviews · doi:10.1021/cr980002q · Cited by 1,538
Self-citationMicro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
Patterning proteins and cells using soft lithography
Kane, R. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00165-9 · Cited by 1,490
A buckling-based metrology for measuring the elastic moduli of polymeric thin films
Stafford, C. M., Harrison, C., Beers, K. L., Karim, A., Amis, E. J., VanLandingham, M. R., Kim, H.-C., Volksen, W., Miller, R. D., & Simonyi, E. E. (2004) · Nature Materials · doi:10.1038/nmat1175 · Cited by 1,360
The upcoming 3D-printing revolution in microfluidics
Bhattacharjee, N., Urrios, A., Kang, S., & Folch, A. (2016) · Lab on a Chip · doi:10.1039/c6lc00163g · Cited by 1,123
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Generation of Solution and Surface Gradients Using Microfluidic Systems
Jeon, N. L., Dertinger, S. K. W., Chiu, D. T., Choi, I. S., Stroock, A. D., & Whitesides, G. M. (2000) · Langmuir · doi:10.1021/la000600b · Cited by 963
Self-citationBaret, J.-C., Miller, O. J., Taly, V., Ryckelynck, M., El-Harrak, A., Frenz, L., Rick, C., Samuels, M. L., Hutchison, J. B., Agresti, J. J., et al. (2009) · Lab on a Chip · doi:10.1039/b902504a · Cited by 951
Controlled buckling of semiconductor nanoribbons for stretchable electronics
Sun, Y., Choi, W. M., Jiang, H., Huang, Y. Y., & Rogers, J. A. (2006) · Nature Nanotechnology · doi:10.1038/nnano.2006.131 · Cited by 933
Xu, S., Yan, Z., Jang, K.-I., Huang, W., Fu, H., Kim, J., Wei, Z., Flavin, M., McCracken, J., Wang, R., et al. (2015) · Science · doi:10.1126/science.1260960 · Cited by 931
PDMS with designer functionalities—Properties, modifications strategies, and applications
Wolf, M. P., Salieb-Beugelaar, G. B., & Hunziker, P. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.06.001 · Cited by 853
Xu, S., Nie, Z., Seo, M., Lewis, P., Kumacheva, E., Stone, H. A., Garstecki, P., Weibel, D. B., Gitlin, I., & Whitesides, G. M. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200462226 · Cited by 830
Self-citationEngineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Microfabrication meets microbiology
Weibel, D. B., DiLuzio, W. R., & Whitesides, G. M. (2007) · Nature Reviews Microbiology · doi:10.1038/nrmicro1616 · Cited by 788
Self-citationYamada, M., Nakashima, M., & Seki, M. (2004) · Analytical Chemistry · doi:10.1021/ac049863r · Cited by 746
Transition from squeezing to dripping in a microfluidic T-shaped junction
DE MENECH, M., GARSTECKI, P., JOUSSE, F., & STONE, H. A. (2008) · Journal of Fluid Mechanics · doi:10.1017/s002211200700910x · Cited by 728
Anderson, J. R., Chiu, D. T., Jackman, R. J., Cherniavskaya, O., McDonald, J. C., Wu, H., Whitesides, S. H., & Whitesides, G. M. (2000) · Analytical Chemistry · doi:10.1021/ac9912294 · Cited by 698
Self-citationStretchable Hydrogel Electronics and Devices
Lin, S., Yuk, H., Zhang, T., Parada, G. A., Koo, H., Yu, C., & Zhao, X. (2016) · Advanced Materials · doi:10.1002/adma.201504152 · Cited by 682
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Stretchable Supercapacitors Based on Buckled Single‐Walled Carbon‐Nanotube Macrofilms
Yu, C., Masarapu, C., Rong, J., Wei, B., & Jiang, H. (2009) · Advanced Materials · doi:10.1002/adma.200901775 · Cited by 683
Quan, P.-L., Sauzade, M., & Brouzes, E. (2018) · Sensors · doi:10.3390/s18041271 · Cited by 664
Low-Cost Printing of Poly(dimethylsiloxane) Barriers To Define Microchannels in Paper
Bruzewicz, D. A., Reches, M., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac702605a · Cited by 616
Self-citationFlexible and Stretchable Capacitive Sensors with Different Microstructures
Qin, J., Yin, L., Hao, Y., Zhong, S., Zhang, D., Bi, K., Zhang, Y., Zhao, Y., & Dang, Z. (2021) · Advanced Materials · doi:10.1002/adma.202008267 · Cited by 616
Autonomous Movement and Self-Assembly
Ismagilov, R. F., Schwartz, A., Bowden, N., & Whitesides, G. M. (2002) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20020215)41:4<652::aid-anie652>3.0.co;2-u · Cited by 601
Self-citationMicrofluidic fuel cells: A review
Kjeang, E., Djilali, N., & Sinton, D. (2009) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.10.011 · Cited by 578
Determining the optimal PDMS–PDMS bonding technique for microfluidic devices
Eddings, M. A., Johnson, M. A., & Gale, B. K. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/6/067001 · Cited by 567
Abgrall, P., & Gué, A.-M. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/5/r01 · Cited by 561
Liao, Y.-C., Fernandopulle, M. S., Wang, G., Choi, H., Hao, L., Drerup, C. M., Patel, R., Qamar, S., Nixon-Abell, J., Shen, Y., et al. (2019) · Cell · doi:10.1016/j.cell.2019.08.050 · Cited by 550
A soft, bistable valve for autonomous control of soft actuators
Rothemund, P., Ainla, A., Belding, L., Preston, D. J., Kurihara, S., Suo, Z., & Whitesides, G. M. (2018) · Science Robotics · doi:10.1126/scirobotics.aar7986 · Cited by 543
Self-citationWong, I., & Ho, C.-M. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0443-4 · Cited by 531
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
Chiu, D. T., Jeon, N. L., Huang, S., Kane, R. S., Wargo, C. J., Choi, I. S., Ingber, D. E., & Whitesides, G. M. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040562297 · Cited by 526
Self-citationHyperelastic pressure sensing with a liquid-embedded elastomer
Park, Y.-L., Majidi, C., Kramer, R., Bérard, P., & Wood, R. J. (2010) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/12/125029 · Cited by 513
Verpoorte, E., & De Rooij, N. F. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813570 · Cited by 503
High-throughput injection with microfluidics using picoinjectors
Abate, A. R., Hung, T., Mary, P., Agresti, J. J., & Weitz, D. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006888107 · Cited by 502
Fluid forces control endothelial sprouting
Song, J. W., & Munn, L. L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1105316108 · Cited by 498
Size-selective collection of circulating tumor cells using Vortex technology
Sollier, E., Go, D. E., Che, J., Gossett, D. R., O'Byrne, S., Weaver, W. M., Kummer, N., Rettig, M., Goldman, J., Nickols, N., et al. (2014) · Lab Chip · doi:10.1039/c3lc50689d · Cited by 498
Membraneless Vanadium Redox Fuel Cell Using Laminar Flow
Ferrigno, R., Stroock, A. D., Clark, T. D., Mayer, M., & Whitesides, G. M. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020812q · Cited by 481
Self-citationBunimovich, Y. L., Shin, Y. S., Yeo, W.-S., Amori, M., Kwong, G., & Heath, J. R. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065923u · Cited by 480
Microfluidic Synthesis of Nanomaterials
Song, Y., Hormes, J., & Kumar, C. S. S. R. (2008) · Small · doi:10.1002/smll.200701029 · Cited by 468
High-throughput single-cell ChIP-seq identifies heterogeneity of chromatin states in breast cancer
Grosselin, K., Durand, A., Marsolier, J., Poitou, A., Marangoni, E., Nemati, F., Dahmani, A., Lameiras, S., Reyal, F., Frenoy, O., et al. (2019) · Nature Genetics · doi:10.1038/s41588-019-0424-9 · Cited by 466
Trantidou, T., Elani, Y., Parsons, E., & Ces, O. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.91 · Cited by 450
Gradients of substrate-bound laminin orient axonal specification of neurons
Dertinger, S. K. W., Jiang, X., Li, Z., Murthy, V. N., & Whitesides, G. M. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.192457199 · Cited by 446
Self-citationApplications of microfluidics in chemical biology
Weibel, D. B., & Whitesides, G. M. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.10.016 · Cited by 443
Self-citationOxygen plasma treatment for reducing hydrophobicity of a sealed polydimethylsiloxane microchannel
Tan, S. H., Nguyen, N.-T., Chua, Y. C., & Kang, T. G. (2010) · Biomicrofluidics · doi:10.1063/1.3466882 · Cited by 440
Li, Z., Wang, Y., Wang, J., Tang, Z., Pounds, J. G., & Lin, Y. (2010) · Analytical Chemistry · doi:10.1021/ac101405a · Cited by 424
Recent Developments in Polymer MEMS
Liu, C. (2007) · Advanced Materials · doi:10.1002/adma.200701709 · Cited by 422
An Integrated Fluorescence Detection System in Poly(dimethylsiloxane) for Microfluidic Applications
Chabinyc, M. L., Chiu, D. T., McDonald, J. C., Stroock, A. D., Christian, J. F., Karger, A. M., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac010423z · Cited by 419
Self-citationMicrofluidic systems for chemical kinetics that rely on chaotic mixing in droplets
Bringer, M. R., Gerdts, C. J., Song, H., Tice, J. D., & Ismagilov, R. F. (2004) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2003.1364 · Cited by 416
Brown, J. A., Pensabene, V., Markov, D. A., Allwardt, V., Neely, M. D., Shi, M., Britt, C. M., Hoilett, O. S., Yang, Q., Brewer, B. M., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4934713 · Cited by 410
Microfluidic Shear Devices for Quantitative Analysis of Cell Adhesion
Lu, H., Koo, L. Y., Wang, W. M., Lauffenburger, D. A., Griffith, L. G., & Jensen, K. F. (2004) · Analytical Chemistry · doi:10.1021/ac049837t · Cited by 405
Computerized microfluidic cell culture using elastomeric channels and Braille displays
Gu, W., Zhu, X., Futai, N., Cho, B. S., & Takayama, S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404353101 · Cited by 403
Microfluidics for flow cytometric analysis of cells and particles
Huh, D., Gu, W., Kamotani, Y., Grotberg, J. B., & Takayama, S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/3/r02 · Cited by 396
Microfluidic Control Using Colloidal Devices
Terray, A., Oakey, J., & Marr, D. W. M. (2002) · Science · doi:10.1126/science.1072133 · Cited by 383
Point-of-care microfluidic devices for pathogen detection
Nasseri, B., Soleimani, N., Rabiee, N., Kalbasi, A., Karimi, M., & Hamblin, M. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.050 · Cited by 382
Waldbaur, A., Rapp, H., Länge, K., & Rapp, B. E. (2011) · Analytical Methods · doi:10.1039/c1ay05253e · Cited by 381
Active droplet sorting in microfluidics: a review
Xi, H.-D., Zheng, H., Guo, W., Gañán-Calvo, A. M., Ai, Y., Tsao, C.-W., Zhou, J., Li, W., Huang, Y., Nguyen, N.-T., et al. (2017) · Lab on a Chip · doi:10.1039/c6lc01435f · Cited by 369
Kloepper, J., Riedemann, L., Amoozgar, Z., Seano, G., Susek, K., Yu, V., Dalvie, N., Amelung, R. L., Datta, M., Song, J. W., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1525360113 · Cited by 357
Xurography: rapid prototyping of microstructures using a cutting plotter
Bartholomeusz, D. A., Boutte, R. W., & Andrade, J. D. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859087 · Cited by 360
Transfer printing techniques for flexible and stretchable inorganic electronics
Linghu, C., Zhang, S., Wang, C., & Song, J. (2018) · npj Flexible Electronics · doi:10.1038/s41528-018-0037-x · Cited by 357
Du, W., Li, L., Nichols, K. P., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b908978k · Cited by 351
Microfluidics: reframing biological enquiry
Duncombe, T. A., Tentori, A. M., & Herr, A. E. (2015) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm4041 · Cited by 345
Microfluidic high-throughput encapsulation and hydrodynamic self-sorting of single cells
Chabert, M., & Viovy, J.-L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708321105 · Cited by 344
Microfabrication in Biology and Medicine
Voldman, J., Gray, M. L., & Schmidt, M. A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.401 · Cited by 344
A Microfluidic Fuel Cell with Flow-Through Porous Electrodes
Kjeang, E., Michel, R., Harrington, D. A., Djilali, N., & Sinton, D. (2008) · Journal of the American Chemical Society · doi:10.1021/ja078248c · Cited by 342
DNA aptamer–micelle as an efficient detection/delivery vehicle toward cancer cells
Wu, Y., Sefah, K., Liu, H., Wang, R., & Tan, W. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0909611107 · Cited by 330
High-Throughput Quantitative Polymerase Chain Reaction in Picoliter Droplets
Kiss, M. M., Ortoleva-Donnelly, L., Beer, N. R., Warner, J., Bailey, C. G., Colston, B. W., Rothberg, J. M., Link, D. R., & Leamon, J. H. (2008) · Analytical Chemistry · doi:10.1021/ac801276c · Cited by 326
Rowat, A. C., Jaalouk, D. E., Zwerger, M., Ung, W. L., Eydelnant, I. A., Olins, D. E., Olins, A. L., Herrmann, H., Weitz, D. A., & Lammerding, J. (2013) · Journal of Biological Chemistry · doi:10.1074/jbc.m112.441535 · Cited by 320
UV/ozone modification of poly(dimethylsiloxane) microfluidic channels
Berdichevsky, Y., Khandurina, J., Guttman, A., & Lo, Y.-H. (2004) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2003.09.022 · Cited by 318
High-throughput size-based rare cell enrichment using microscale vortices
Hur, S. C., Mach, A. J., & Di Carlo, D. (2011) · Biomicrofluidics · doi:10.1063/1.3576780 · Cited by 317
Aerogels from nanofibrillated cellulose with tunable oleophobicity
Aulin, C., Netrval, J., Wågberg, L., & Lindström, T. (2010) · Soft Matter · doi:10.1039/c001939a · Cited by 306
Active droplet generation in microfluidics
Chong, Z. Z., Tan, S. H., Gañán-Calvo, A. M., Tor, S. B., Loh, N. H., & Nguyen, N.-T. (2016) · Lab on a Chip · doi:10.1039/c5lc01012h · Cited by 297
Xu, Z., Gao, Y., Hao, Y., Li, E., Wang, Y., Zhang, J., Wang, W., Gao, Z., & Wang, Q. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.02.045 · Cited by 295
Microtubules self-repair in response to mechanical stress
Schaedel, L., John, K., Gaillard, J., Nachury, M. V., Blanchoin, L., & Théry, M. (2015) · Nature Materials · doi:10.1038/nmat4396 · Cited by 294
Nanoholes As Nanochannels: Flow-through Plasmonic Sensing
Eftekhari, F., Escobedo, C., Ferreira, J., Duan, X., Girotto, E. M., Brolo, A. G., Gordon, R., & Sinton, D. (2009) · Analytical Chemistry · doi:10.1021/ac900221y · Cited by 290
Antibiotics as a selective driver for conjugation dynamics
Lopatkin, A. J., Huang, S., Smith, R. P., Srimani, J. K., Sysoeva, T. A., Bewick, S., Karig, D. K., & You, L. (2016) · Nature Microbiology · doi:10.1038/nmicrobiol.2016.44 · Cited by 285
Dynamics of shear-induced ATP release from red blood cells
Wan, J., Ristenpart, W. D., & Stone, H. A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805779105 · Cited by 279
Recent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277
DC-Dielectrophoretic separation of biological cells by size
Kang, Y., Li, D., Kalams, S. A., & Eid, J. E. (2008) · Biomedical Microdevices · doi:10.1007/s10544-007-9130-y · Cited by 276
Aptamer-Based Microfluidic Device for Enrichment, Sorting, and Detection of Multiple Cancer Cells
Xu, Y., Phillips, J. A., Yan, J., Li, Q., Fan, Z. H., & Tan, W. (2009) · Analytical Chemistry · doi:10.1021/ac9012072 · Cited by 275
van Midwoud, P. M., Janse, A., Merema, M. T., Groothuis, G. M. M., & Verpoorte, E. (2012) · Analytical Chemistry · doi:10.1021/ac300771z · Cited by 274
Prototyping of Microfluidic Devices in Poly(dimethylsiloxane) Using Solid-Object Printing
McDonald, J. C., Chabinyc, M. L., Metallo, S. J., Anderson, J. R., Stroock, A. D., & Whitesides, G. M. (2002) · Analytical Chemistry · doi:10.1021/ac010938q · Cited by 266
Self-citationBartolo, D., Degré, G., Nghe, P., & Studer, V. (2008) · Lab Chip · doi:10.1039/b712368j · Cited by 265
Single-cell deep phenotyping of IgG-secreting cells for high-resolution immune monitoring
Eyer, K., Doineau, R. C. L., Castrillon, C. E., Briseño-Roa, L., Menrath, V., Mottet, G., England, P., Godina, A., Brient-Litzler, E., Nizak, C., et al. (2017) · Nature Biotechnology · doi:10.1038/nbt.3964 · Cited by 264
Mazutis, L., Araghi, A. F., Miller, O. J., Baret, J.-C., Frenz, L., Janoshazi, A., Taly, V., Miller, B. J., Hutchison, J. B., Link, D., et al. (2009) · Analytical Chemistry · doi:10.1021/ac900403z · Cited by 263
High density 3D printed microfluidic valves, pumps, and multiplexers
Gong, H., Woolley, A. T., & Nordin, G. P. (2016) · Lab on a Chip · doi:10.1039/c6lc00565a · Cited by 263
Chuah, Y. J., Koh, Y. T., Lim, K., Menon, N. V., Wu, Y., & Kang, Y. (2015) · Scientific Reports · doi:10.1038/srep18162 · Cited by 262
Adsorption of Proteins to Hydrophobic Sites on Mixed Self-Assembled Monolayers
Ostuni, E., Grzybowski, B. A., Mrksich, M., Roberts, C. S., & Whitesides, G. M. (2003) · Langmuir · doi:10.1021/la020649c · Cited by 261
Self-citationRapid electrochemical detection on a mobile phone
Lillehoj, P. B., Huang, M.-C., Truong, N., & Ho, C.-M. (2013) · Lab on a Chip · doi:10.1039/c3lc50306b · Cited by 259
Light to Shape the Future: From Photolithography to 4D Printing
del Barrio, J., & Sánchez‐Somolinos, C. (2019) · Advanced Optical Materials · doi:10.1002/adom.201900598 · Cited by 258
Optofluidic trapping and transport on solid core waveguides within a microfluidic device
Schmidt, B. S., Yang, A. H. J., Erickson, D., & Lipson, M. (2007) · Optics Express · doi:10.1364/oe.15.014322 · Cited by 250
Metadata
- Authors
- Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-10-24
- Volume
- 70
- Issue
- 23
- Pages
- 4974-4984
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2026908430
- Cited by
- 5,288
- References
- 1
- FWCI
- 47.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.