The DOI matches its Crossref record; 344 of the 344 references it cites were found in a registry or an index.
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Abstract
Abstract Patient-friendly medical diagnostics and treatments have been receiving a great deal of interest due to their rapid and cost-effective health care applications with minimized risk of infection, which has the potential to replace conventional hospital-based medical procedures. In particular, the integration of recently developed materials into health care devices allows the rapid development of point-of-care (POC) sensing platforms and implantable devices with special functionalities. In this review, the recent advances in biosensors for patient-friendly diagnosis and implantable devices for patient-friendly treatment are discussed. Comprehensive analysis of portable and wearable biosensing platforms for patient-friendly health monitoring and disease diagnosis is provided, including topics such as materials selection, device structure and integration, and biomarker detection strategies. Moreover, specific challenges related to each biological fluid for wearable biosensor-based POC applications are presented. Also, advances in implantable devices, including recent materials development and wireless communication strategies, are discussed. Furthermore, various patient-friendly surgical and treatment approaches are reviewed, such as minimally invasive insertion and mounting, in vivo electrical and optical modulations, and post-operation health monitoring. Finally, the challenges and future perspectives toward the development of the patient-friendly diagnosis and treatment are provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–344 of 344
Nanotechnology-Enhanced No-Wash Biosensors for in Vitro Diagnostics of Cancer
Huang, X., Liu, Y., Yung, B., Xiong, Y., & Chen, X. (2017) · ACS Nano · doi:10.1021/acsnano.7b02618 · Cited by 259
Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles
Miller, P. R., Taylor, R. M., Tran, B. Q., Boyd, G., Glaros, T., Chavez, V. H., Krishnakumar, R., Sinha, A., Poorey, K., Williams, K. P., et al. (2018) · Communications Biology · doi:10.1038/s42003-018-0170-z · Cited by 258
Kim, K., Kim, M.-J., Kim, D. W., Kim, S. Y., Park, S., & Park, C. B. (2020) · Nature Communications · doi:10.1038/s41467-019-13901-z · Cited by 255
Self-citationRecent advances in lab-on-a-chip technologies for viral diagnosis
Zhu, H., Fohlerová, Z., Pekárek, J., Basova, E., & Neužil, P. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112041 · Cited by 251
Gong, H., Chen, F., Huang, Z., Gu, Y., Zhang, Q., Chen, Y., Zhang, Y., Zhuang, J., Cho, Y.-K., Fang, R. H., et al. (2019) · ACS Nano · doi:10.1021/acsnano.9b00911 · Cited by 248
Flexible, sticky, and biodegradable wireless device for drug delivery to brain tumors
Lee, J., Cho, H. R., Cha, G. D., Seo, H., Lee, S., Park, C.-K., Kim, J. W., Qiao, S., Wang, L., Kang, D., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-13198-y · Cited by 246
Self-citationQiu, X., & Hildebrandt, N. (2015) · ACS Nano · doi:10.1021/acsnano.5b03364 · Cited by 244
Liu, Q., Liu, Y., Wu, F., Cao, X., Li, Z., Alharbi, M., Abbas, A. N., Amer, M. R., & Zhou, C. (2018) · ACS Nano · doi:10.1021/acsnano.7b06823 · Cited by 244
Sekine, Y., Kim, S. B., Zhang, Y., Bandodkar, A. J., Xu, S., Choi, J., Irie, M., Ray, T. R., Kohli, P., Kozai, N., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00530c · Cited by 242
Self-citationNetwork cracks-based wearable strain sensors for subtle and large strain detection of human motions
Wang, S., Xiao, P., Liang, Y., Zhang, J., Huang, Y., Wu, S., Kuo, S.-W., & Chen, T. (2018) · Journal of Materials Chemistry C · doi:10.1039/c8tc00433a · Cited by 242
He, Q., Yu, D., Bao, M., Korensky, G., Chen, J., Shin, M., Kim, J., Park, M., Qin, P., & Du, K. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112068 · Cited by 240
Bioresorbable Electronic Stent Integrated with Therapeutic Nanoparticles for Endovascular Diseases
Son, D., Lee, J., Lee, D. J., Ghaffari, R., Yun, S., Kim, S. J., Lee, J. E., Cho, H. R., Yoon, S., Yang, S., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b00651 · Cited by 239
Self-citationDevelopment and evaluation of a rapid CRISPR-based diagnostic for COVID-19
Hou, T., Zeng, W., Yang, M., Chen, W., Ren, L., Ai, J., Wu, J., Liao, Y., Gou, X., Li, Y., et al. (2020) · PLOS Pathogens · doi:10.1371/journal.ppat.1008705 · Cited by 239
Son, J. H., Cho, B., Hong, S., Lee, S. H., Hoxha, O., Haack, A. J., & Lee, L. P. (2015) · Light: Science & Applications · doi:10.1038/lsa.2015.53 · Cited by 234
Liu, J., Chen, X., Wang, Q., Xiao, M., Zhong, D., Sun, W., Zhang, G., & Zhang, Z. (2019) · Nano Letters · doi:10.1021/acs.nanolett.8b03818 · Cited by 233
Sepsis and septic shock: Guideline-based management
Dugar, S., Choudhary, C., & Duggal, A. (2020) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.87a.18143 · Cited by 229
Conducting Nanomaterial Sensor Using Natural Receptors
Kwon, O. S., Song, H. S., Park, T. H., & Jang, J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00159 · Cited by 223
Tseng, P., Napier, B., Garbarini, L., Kaplan, D. L., & Omenetto, F. G. (2018) · Advanced Materials · doi:10.1002/adma.201703257 · Cited by 221
A contact lens with an integrated lactate sensor
Thomas, N., Lähdesmäki, I., & Parviz, B. A. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.12.049 · Cited by 220
Xu, L., Shoaie, N., Jahanpeyma, F., Zhao, J., Azimzadeh, M., & Al−Jamal, K. T. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112222 · Cited by 220
EM-Wave Biosensors: A Review of RF, Microwave, mm-Wave and Optical Sensing
Mehrotra, P., Chatterjee, B., & Sen, S. (2019) · Sensors · doi:10.3390/s19051013 · Cited by 219
Long-term survival of cancer patients compared to heart failure and stroke: A systematic review
Askoxylakis, V., Thieke, C., Pleger, S. T., Most, P., Tanner, J., Lindel, K., Katus, H. A., Debus, J., & Bischof, M. (2010) · BMC Cancer · doi:10.1186/1471-2407-10-105 · Cited by 217
Mahmoudi, T., de la Guardia, M., & Baradaran, B. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115842 · Cited by 217
Recent approaches for optical smartphone sensing in resource-limited settings: a brief review
McCracken, K. E., & Yoon, J.-Y. (2016) · Analytical Methods · doi:10.1039/c6ay01575a · Cited by 216
Zhang, J., Cheng, Y., Tebyetekerwa, M., Meng, S., Zhu, M., & Lu, Y. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201806407 · Cited by 216
Chen, D., Mauk, M., Qiu, X., Liu, C., Kim, J., Ramprasad, S., Ongagna, S., Abrams, W. R., Malamud, D., Corstjens, P. L. A. M., et al. (2010) · Biomedical Microdevices · doi:10.1007/s10544-010-9423-4 · Cited by 213
Advances in Smartphone-Based Point-of-Care Diagnostics
Xu, X., Akay, A., Wei, H., Wang, S., Pingguan-Murphy, B., Erlandsson, B.-E., Li, X., Lee, W., Hu, J., Wang, L., et al. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2378776 · Cited by 213
Organic Transistor-Based Chemical Sensors for Wearable Bioelectronics
Lee, M. Y., Lee, H. R., Park, C. H., Han, S. G., & Oh, J. H. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00465 · Cited by 209
(1991) · Choice Reviews Online · doi:10.5860/choice.28-5105 · Cited by 207
Mechanically transformative electronics, sensors, and implantable devices
Byun, S.-H., Sim, J. Y., Zhou, Z., Lee, J., Qazi, R., Walicki, M. C., Parker, K. E., Haney, M. P., Choi, S. H., Shon, A., et al. (2019) · Science Advances · doi:10.1126/sciadv.aay0418 · Cited by 206
Lu, R., Wu, X., Wan, Z., Li, Y., Jin, X., & Zhang, C. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21082826 · Cited by 204
Tear glucose levels in normal people and in diabetic patients.
Sen, D. K., & Sarin, G. S. (1980) · British Journal of Ophthalmology · doi:10.1136/bjo.64.9.693 · Cited by 203
Single- and Two-Stage, Closed-Tube, Point-of-Care, Molecular Detection of SARS-CoV-2
Song, J., El-Tholoth, M., Li, Y., Graham-Wooten, J., Liang, Y., Li, J., Li, W., Weiss, S. R., Collman, R. G., & Bau, H. H. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c03016 · Cited by 199
Ping, J., Vishnubhotla, R., Vrudhula, A., & Johnson, A. T. C. (2016) · ACS Nano · doi:10.1021/acsnano.6b04110 · Cited by 190
Yang, J., Wang, K., Xu, H., Yan, W., Jin, Q., & Cui, D. (2019) · Talanta · doi:10.1016/j.talanta.2019.04.054 · Cited by 186
Rong, Z., Wang, Q., Sun, N., Jia, X., Wang, K., Xiao, R., & Wang, S. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.12.043 · Cited by 184
Lee, Y., Howe, C., Mishra, S., Lee, D. S., Mahmood, M., Piper, M., Kim, Y., Tieu, K., Byun, H.-S., Coffey, J. P., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1719573115 · Cited by 183
The genetic basis of hyperuricaemia and gout
Merriman, T. R., & Dalbeth, N. (2011) · Joint Bone Spine · doi:10.1016/j.jbspin.2010.02.027 · Cited by 180
Graphene field-effect transistors
Reddy, D., Register, L. F., Carpenter, G. D., & Banerjee, S. K. (2011) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/44/31/313001 · Cited by 177
Assawaworrarit, S., & Fan, S. (2020) · Nature Electronics · doi:10.1038/s41928-020-0399-7 · Cited by 176
Functional biomaterials towards flexible electronics and sensors
Sun, Q., Qian, B., Uto, K., Chen, J., Liu, X., & Minari, T. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.08.018 · Cited by 175
Soft Wearable Systems for Colorimetric and Electrochemical Analysis of Biofluids
Ghaffari, R., Choi, J., Raj, M. S., Chen, S., Lee, S. P., Reeder, J. T., Aranyosi, A. J., Leech, A., Li, W., Schon, S., et al. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201907269 · Cited by 173
Saha, S., Cano-Garcia, H., Sotiriou, I., Lipscombe, O., Gouzouasis, I., Koutsoupidou, M., Palikaras, G., Mackenzie, R., Reeve, T., Kosmas, P., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-06926-1 · Cited by 171
Kang, S., Peng, W., Zhu, Y., Lu, S., Zhou, M., Lin, W., Wu, W., Huang, S., Jiang, L., Luo, X., et al. (2020) · International Journal of Antimicrobial Agents · doi:10.1016/j.ijantimicag.2020.105950 · Cited by 168
Lee, J., Morita, M., Takemura, K., & Park, E. Y. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.11.052 · Cited by 166
Lu, R., Wu, X., Wan, Z., Li, Y., Zuo, L., Qin, J., Jin, X., & Zhang, C. (2020) · Virologica Sinica · doi:10.1007/s12250-020-00218-1 · Cited by 165
CRISPR-based surveillance for COVID-19 using genomically-comprehensive machine learning designPreprint
Metsky, H. C., Freije, C. A., Kosoko-Thoroddsen, T.-S. F., Sabeti, P. C., & Myhrvold, C. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.02.26.967026 · Cited by 162
Assembling Amperometric Biosensors for Clinical Diagnostics
Belluzo, M. S., Ribone, M. E., & Lagier, C. M. (2008) · Sensors · doi:10.3390/s8031366 · Cited by 161
Wireless gas detection with a smartphone via rf communication
Azzarelli, J. M., Mirica, K. A., Ravnsbæk, J. B., & Swager, T. M. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1415403111 · Cited by 160
Smartphone-assisted personalized diagnostic devices and wearable sensors
Purohit, B., Kumar, A., Mahato, K., & Chandra, P. (2020) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2019.08.015 · Cited by 159
Hanna, J., Bteich, M., Tawk, Y., Ramadan, A., Dia, B., Asadallah, F. A., Eid, A., Kanj, R. N., Costantine, J., & Eid, A. A. (2020) · Science Advances · doi:10.1126/sciadv.aba5320 · Cited by 158
Xiao, G., He, J., Chen, X., Qiao, Y., Wang, F., Xia, Q., Yu, L. D., & Lu, Z. (2019) · Cellulose · doi:10.1007/s10570-019-02396-y · Cited by 155
Zheng, C., Huang, L., Zhang, H., Sun, Z. J., Zhang, Z., & Zhang, G. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b03941 · Cited by 154
Integrated Biosensor for Rapid and Point-of-Care Sepsis Diagnosis
Min, J., Nothing, M., Coble, B. W., Zheng, H., Park, J., Im, H., Weber, G. F., Castro, C. M., Świrski, F. K., Weissleder, R., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b08965 · Cited by 154
Novartis signs up for Google smart lens
Senior, M. (2014) · Nature Biotechnology · doi:10.1038/nbt0914-856 · Cited by 152
Soft armor materials constructed with Kevlar fabric and a novel shear thickening fluid
Qin, J., Guo, B., Zhang, L., Wang, T., Zhang, G., & Shi, X. (2019) · Composites Part B Engineering · doi:10.1016/j.compositesb.2019.107686 · Cited by 149
Eersels, K., Lieberzeit, P. A., & Wagner, P. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00572 · Cited by 146
Ultrafast Photonic PCR Based on Photothermal Nanomaterials
You, M., Li, Z., Feng, S., Gao, B., Yao, C., Hu, J., & Xu, F. (2020) · Trends in biotechnology · doi:10.1016/j.tibtech.2019.12.006 · Cited by 144
Welton, J. L., Loveless, S., Stone, T., von Ruhland, C., Robertson, N. P., & Clayton, A. (2017) · Journal of Extracellular Vesicles · doi:10.1080/20013078.2017.1369805 · Cited by 143
Ultrasensitive Field‐Effect Biosensors Enabled by the Unique Electronic Properties of Graphene
Zhang, X., Jing, Q., Shen, A., Schneider, G. F., Kireev, D., Zhang, Z., & Fu, W. (2019) · Small · doi:10.1002/smll.201902820 · Cited by 142
AKOUM, N. W., McGann, C. J., VERGARA, G., Badger, T. J., Ranjan, R., Mahnkopf, C., Kholmovski, E. G., MacLeod, R., & MARROUCHE, N. F. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02140.x · Cited by 138
Nucleocapsid Protein as Early Diagnostic Marker for SARS
Che, X.-Y., Hao, W., Wang, Y., Di, B., Yin, K., Xu, Y.-C., Feng, C.-S., Wan, Z.-Y., Cheng, V. C., & Yuen, K. (2004) · Emerging infectious diseases · doi:10.3201/eid1011.040516 · Cited by 137
Reverse iontophoresis for non-invasive transdermal monitoring
Leboulanger, B., Guy, R. H., & Delgado-Charro, M. B. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/3/r01 · Cited by 136
Extracellular and cerebrospinal fluids
Segal, M. B. (1993) · Journal of Inherited Metabolic Disease · doi:10.1007/bf00711896 · Cited by 136
Revisiting the dangers of the coronavirus in the ophthalmology practice
Seah, I. Y. J., Su, X., & Gopal, L. (2020) · Eye · doi:10.1038/s41433-020-0790-7 · Cited by 134
The recognition of Lesch‐Nyhan syndrome as an inborn error of purine metabolism
Nyhan, W. L. (1997) · Journal of Inherited Metabolic Disease · doi:10.1023/a:1005348504512 · Cited by 133
Wireless optofluidic brain probes for chronic neuropharmacology and photostimulation
Qazi, R., Gomez, A. M., Castro, D. C., Zou, Z., Sim, J. Y., Xiong, Y., Abdo, J., Kim, C. Y., Anderson, A., Lohner, F., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0432-1 · Cited by 133
Lau, S. K. P., Woo, P. C. Y., Wong, B. H. L., Tsoi, H., Woo, G. K. S., Poon, R. W., Chan, K., Wei, W., Peiris, M. J. S., & Yuen, K. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.7.2884-2889.2004 · Cited by 131
Recent advances on application of peptide nucleic acids as a bioreceptor in biosensors development
Saadati, A., Hassanpour, S., de la Guárdia, M., Mosafer, J., Hashemzaei, M., Mokhtarzadeh, A., & Baradaran, B. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.02.030 · Cited by 130
Yang, B., Fang, X., & Kong, J. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202000591 · Cited by 130
An LTCC-based microfluidic system for label-free, electrochemical detection of cortisol
Vasudev, A., Kaushik, A. K., Tomizawa, Y., Norena, N., & Bhansali, S. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.02.096 · Cited by 129
Baehner, F. L., Achacoso, N. S., Maddala, T., Shak, S., Quesenberry, C. P., Goldstein, L. C., Gown, A. M., & Habel, L. A. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.24.8211 · Cited by 128
Concept, design and fabrication of smart orthopedic implants
Burny, F., Donkerwolcke, M., Moulart, F., Bourgois, R., Puers, R., Schuylenbergh, K. V., Barbosa, M. A., Paiva, O. C., Rodes, F., Bégueret, J.-B., et al. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00062-x · Cited by 125
Challenges and perspectives in the development of paper-based lateral flow assays
Kasetsirikul, S., Shiddiky, M. J. A., & Nguyen, N. (2020) · Microfluidics and Nanofluidics · doi:10.1007/s10404-020-2321-z · Cited by 125
Reusable, Robust, and Accurate Laser-Generated Photonic Nanosensor
Yetisen, A. K., Montelongo, Y., da Cruz Vasconcellos, F., Martinez-Hurtado, J. L., Neupane, S., Butt, H., Qasim, M. M., Blyth, J., Burling, K., Carmody, J. B., et al. (2014) · Nano Letters · doi:10.1021/nl5012504 · Cited by 123
Joung, H., Ballard, Z. S., Wu, J., Tseng, D. K., Teshome, H., Zhang, L., Horn, E. J., Arnaboldi, P. M., Dattwyler, R. J., Garner, O. B., et al. (2019) · ACS Nano · doi:10.1021/acsnano.9b08151 · Cited by 123
Organic semiconductors for biological sensing
Borges‐González, J., Kousseff, C. J., & Nielsen, C. B. O. (2019) · Journal of Materials Chemistry C · doi:10.1039/c8tc05900d · Cited by 121
Adaptive self-healing electronic epineurium for chronic bidirectional neural interfaces
Song, K.-I., Seo, H., Seong, D., Kim, S., Yu, K. J., Kim, Y.-C., Kim, J., Kwon, S. J., Han, H.-S., Youn, I., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18025-3 · Cited by 120
Self-citationLü, N., Gao, A., Dai, P., Song, S., Fan, C., Wang, Y., & Li, T. (2014) · Small · doi:10.1002/smll.201302990 · Cited by 120
Conducting polymer-based biosensors
Contractor, A. Q., Sureshkumar, T. N., Narayanan, R., Sukeerthi, S., Lal, R., & Srinivasa, R. S. (1994) · Electrochimica Acta · doi:10.1016/0013-4686(94)e0054-4 · Cited by 120
A novel OFET-based biosensor for the selective and sensitive detection of lactate levels
Minami, T., Sato, T., Minamiki, T., Fukuda, K., Kumaki, D., & Tokito, S. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.002 · Cited by 119
Two-Stage Isothermal Enzymatic Amplification for Concurrent Multiplex Molecular Detection
Song, J., Liu, C., Mauk, M. G., Rankin, S. C., Lok, J. B., Greenberg, R. M., & Bau, H. H. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2016.263665 · Cited by 116
Nanohole array plasmonic biosensors: Emerging point-of-care applications
Prasad, A., Choi, J., Jia, Z., Park, S., & Gartia, M. R. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.037 · Cited by 113
Self-citationSensors for detecting biological agents
Sapsford, K. E., Bradburne, C. E., Delehanty, J. B., & Medintz, I. L. (2008) · Materials Today · doi:10.1016/s1369-7021(08)70018-x · Cited by 112
Chalmers, E., Lee, H., Zhu, C., & Liu, X. (2019) · Chemistry of Materials · doi:10.1021/acs.chemmater.9b03655 · Cited by 112
Jin, Q., Chen, H., Li, X., Huang, X., Wu, Q., He, G., Hang, T., Yang, C., Jiang, Z., Li, E., et al. (2019) · Small · doi:10.1002/smll.201804298 · Cited by 110
Gao, Z., Xia, H., Zauberman, J., Tomaiuolo, M., Ping, J., Zhang, Q., Ducos, P., Ye, H., Wang, S., Yang, X., et al. (2018) · Nano Letters · doi:10.1021/acs.nanolett.8b00572 · Cited by 107
Electrochemical processes and mechanistic aspects of field-effect sensors for biomolecules
Huang, W., Diallo, A. K., Dailey, J., Besar, K., & Katz, H. E. (2015) · Journal of Materials Chemistry C · doi:10.1039/c5tc00755k · Cited by 102
Continuous Monitoring of Wound Healing Using a Wearable Enzymatic Uric Acid Biosensor
RoyChoudhury, S., Umasankar, Y., Jaller, J. A., Herskovitz, I., Mervis, J. S., Darwin, E., Hirt, P. A., Borda, L. J., Lev‐Tov, H. A., Kirsner, R. S., et al. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0231808jes · Cited by 101
DNA Nanotweezers and Graphene Transistor Enable Label‐Free Genotyping
Hwang, M. T., Wang, Z., Ping, J., Ban, D. K., Shiah, Z. C., Antonschmidt, L., Lee, J., Liu, Y., Karkisaval, A. G., Johnson, A. T. C., et al. (2018) · Advanced Materials · doi:10.1002/adma.201802440 · Cited by 101
3D biosensors in advanced medical diagnostics of high mortality diseases
Rebelo, R., Barbosa, A. I., Caballero, D., Kwon, I. K., Oliveira, J. M., Kundu, S. C., Reis, R. L., & Correlo, V. M. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.12.057 · Cited by 101
Analysis of tear glucose concentration with electrospray ionization mass spectrometry
Taormina, C. R., Baca, J. T., Asher, S. A., Grabowski, J. J., & Finegold, D. N. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.10.002 · Cited by 99
Sustained release of targeted cardiac therapy with a replenishable implanted epicardial reservoir
Whyte, W., Roche, E. T., Varela, C. E., Mendez, K. L., Islam, S., O’Neill, H., Weafer, F. M., Shirazi, R. N., Weaver, J. C., Vasilyev, N. V., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0247-5 · Cited by 98
Hoyos‐Nogués, M., Gil, F. J., & Mas‐Moruno, C. (2018) · Molecules · doi:10.3390/molecules23071683 · Cited by 97
Lee, S. J., Yoon, H. S., Xuan, X., Park, J. Y., Paik, S., & Allen, M. G. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.08.013 · Cited by 95
CNT/STF/Kevlar-based wearable electronic textile with excellent anti-impact and sensing performance
Liu, M., Zhang, S., Liu, S., Cao, S., Wang, S., Bai, L., Sang, M., Xuan, S., Jiang, W., & Gong, X. (2019) · Composites Part A Applied Science and Manufacturing · doi:10.1016/j.compositesa.2019.105612 · Cited by 95
Biosensors and Internet of Things in smart healthcare applications: challenges and opportunities
Pateraki, M., Fysarakis, K., Sakkalis, V., Spanoudakis, G., Varlamis, I., Maniadakis, M., Lourakis, M., Ioannidis, S., Cummins, N., Schuller, B. W., et al. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815369-7.00002-1 · Cited by 94
Excretion of Urea, Sodium, Potassium and Chloride in Human Tears
Thaysen, J. H., & Thorn, N. A. (1954) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1954.178.1.160 · Cited by 93
Bertók, T., Šedivá, A., Katrlík, J., Gemeiner, P., Mikula, M., Nosko, M., & Tkáč, J. (2013) · Talanta · doi:10.1016/j.talanta.2013.02.052 · Cited by 93
Garcia-Cordero, E., Bellando, F., Zhang, J., Wildhaber, F., Longo, J., Guérin, H., & Ionescu, A. M. (2018) · ACS Nano · doi:10.1021/acsnano.8b07413 · Cited by 93
Recent advances in cancer early detection and diagnosis: Role of nucleic acid based aptasensors
Hassan, E. M., & DeRosa, M. C. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115806 · Cited by 87
Eccrine Sweat as a Biofluid for Profiling Immune Biomarkers
Katchman, B. A., Zhu, M., Blain Christen, J., & Anderson, K. S. (2018) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201800010 · Cited by 86
Zulkowski, K. M. (2017) · Advances in Skin & Wound Care · doi:10.1097/01.asw.0000521048.64537.6e · Cited by 86
Noninvasive Glucose Monitoring with a Contact Lens and Smartphone
Lin, Y.-R., Hung, C.-C., Chiu, H., Chang, P.-H., Li, B., Cheng, S.-J., Yang, J., Lin, S., & Chen, G. (2018) · Sensors · doi:10.3390/s18103208 · Cited by 86
Recent progress in lab-on-a-chip for pharmaceutical analysis and pharmacological/toxicological test
Ai, Y., Zhang, F., Wang, C., Xie, R., & Liang, Q. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.06.026 · Cited by 86
Intraocular Pressure Monitoring Following Islet Transplantation to the Anterior Chamber of the Eye
Kim, J., Kim, J. J., Ku, M., Cha, E., Ju, S., Park, W. Y., Kim, K. H., Kim, D. W., Berggren, P., & Park, J. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b03605 · Cited by 85
Medical Biosensors for Point of Care (POC) Applications
Narayan, R. J. (2016) · Elsevier eBooks · doi:10.1016/c2014-0-01459-1 · Cited by 82
Initial Clinical Testing of a Holographic Non-Invasive Contact Lens Glucose Sensor
Domschke, A., March, W. F., Kabilan, S., & Lowe, C. (2006) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.8.89 · Cited by 81
Wang, S., Chen, K., Wang, M., Li, H., Chen, G., Liu, J., Xu, L., Yue, J., Meng, C., Zheng, X., et al. (2018) · Journal of Materials Chemistry C · doi:10.1039/c7tc05970a · Cited by 80
Shen, Y. H., Tran, T., Modha, S., Tsutsui, H., & Mulchandani, A. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.09.041 · Cited by 80
Quality of DNA extracted from saliva samples collected with the Oragene™ DNA self-collection kit
Nunes, A. P., Oliveira, I. O., dos Santos, B. R., et al. (2012) · BMC Medical Research Methodology · doi:10.1186/1471-2288-12-65 · Cited by 78
Direct immune-detection of cortisol by chemiresistor graphene oxide sensor
Kim, Y., Lee, K., Jung, H., Kang, H. K., Jo, J., Park, I., & Lee, H. H. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.017 · Cited by 75
Lee, G., Park, J., Byun, J., Yang, J. C., Kwon, S. Y., Kim, C., Jang, C., Sim, J. Y., Yook, J., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201906269 · Cited by 72
Self-citationCavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71
Zhou, X., Gao, X., Song, F., et al. (2017) · Applied Surface Science · doi:10.1016/j.apsusc.2017.06.199 · Cited by 69
Zhang, Y., Chen, Y., Man, T., Huang, D., Li, X., Zhu, H., & Li, Z. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0078-x · Cited by 67
Lab in a Tube: Point-of-Care Detection of Escherichia coli
Amin, N., Sena‐Torralba, A., Álvarez-Diduk, R., Afkhami, A., & Merkoçi, A. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04369 · Cited by 67
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201970337 · Cited by 65
Self-citationA shape-memory and spiral light-emitting device for precise multisite stimulation of nerve bundles
Zheng, H., Zhang, Z., Jiang, S., Yan, B., Shi, X., Xie, Y., Huang, X., Yu, Z., Liu, H., Weng, S., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10418-3 · Cited by 58
Wormser, G. P., Levin, A. E., Soman, S., Adenikinju, O., Longo, M. V., & Branda, J. A. (2013) · Journal of Clinical Microbiology · doi:10.1128/jcm.01853-13 · Cited by 58
Fluorescent Measurement in the Non-Invasive Contact Lens Glucose Sensor
March, W., Lazzaro, D., & Rastogi, S. (2006) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.8.312 · Cited by 58
Lack of Compliance With Home Blood Glucose Monitoring Predicts Hospitalization in Diabetes
Burge, M. R. (2001) · Diabetes Care · doi:10.2337/diacare.24.8.1502 · Cited by 54
Barman, S. C., Zahed, M. A., Sharifuzzaman, M., Ko, S. G., Yoon, H., Nah, J. S., Xuan, X., & Park, J. Y. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201907297 · Cited by 50
Metallic mesh-based terahertz biosensing of single- and double-stranded DNA
Hasebe, T., Kawabe, S., Matsui, H., & Tabata, H. (2012) · Journal of Applied Physics · doi:10.1063/1.4761966 · Cited by 49
Extracellular fluid and its proteins: dehydration, shock, and recovery
Holliday, M. (1999) · Pediatric nephrology (Berlin, West) · doi:10.1007/s004670050741 · Cited by 45
Lee, G., Lee, G. S., Byun, J., Yang, J. C., Jang, C., Kim, S., Kim, H., Park, J., Lee, H. J., Yook, J., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c05105 · Cited by 45
Self-citationMukama, O., Nie, C., Habimana, J. D. D., Meng, X., Ting, Y., Fanuel, S., AL-Farga, A. M., Mugisha, S., Rwibasira, P., Zhang, Y., et al. (2020) · Analytical Biochemistry · doi:10.1016/j.ab.2020.113762 · Cited by 43
Prevention of premature cardiovascular death worldwide
Read, S. H., & Wild, S. H. (2019) · The Lancet · doi:10.1016/s0140-6736(19)32034-3 · Cited by 42
Tear lipocalin is the major endonuclease in tears.
Yusifov, T., Abduragimov, A. R., Narsinh, K. F., Gasymov, O. K., & Glasgow, B. J. (2008) · Europe PMC (PubMed Central) · Cited by 39
(2020) · Nature Medicine · doi:10.1038/s41591-019-0740-8 · Cited by 39
Moran, M. E. (2003) · Frontiers in bioscience · doi:10.2741/1178 · Cited by 37
Adamson, T., Eusebio, F. A., Cook, C. B., & Belle, J. T. L. (2012) · The Analyst · doi:10.1039/c2an35645g · Cited by 37
Nanotechnology-based electrochemical detection strategies for hypertension markers
Madhurantakam, S., Babu, K. J., Rayappan, J. B. B., & Krishnan, U. M. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.034 · Cited by 35
Instrument-free nucleic acid amplification assays for global health settings
LaBarre, P., Boyle, D., Hawkins, K. R., & Weigl, B. H. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.882868 · Cited by 33
Lee, J., Parker, K. E., Kawakami, C., Kim, J. R., Qazi, R., Yea, J., Zhang, S., Kim, C. Y., Bilbily, J., Xiao, J., et al. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202004285 · Cited by 32
Proteomic Characterization of Immunoglobulin Content in Dermal Interstitial Fluid
Arévalo, M. T., Rizzo, G. M., Polsky, R., Glaros, T., & Mach, P. M. (2019) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00155 · Cited by 29
Lee, W., Park, Y., Shrivastava, S., Jung, T., Meeseepong, M., Lee, J., Jeon, B., Yang, S. H., & Lee, N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112007 · Cited by 29
Age‐related changes in male forearm skin‐to‐fat tissue dielectric constant at 300 MH z
MAYROVITZ, H. N., Grammenos, A., Corbitt, K., & Bartos, S. (2015) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12286 · Cited by 28
Flexible substrate sensors for multiplex biomarker monitoring
Brennan, D., & Galvin, P. (2018) · MRS Communications · doi:10.1557/mrc.2018.134 · Cited by 20
Recent Developments in Microfluidic ‐Based Point‐of‐care Testing ( POCT ) Diagnoses
Wang, D., Chan, H. N., Liu, Z., Micheal, S., Li, L., Dehghan‐Baniani, D., Tan, M. J. A., Huang, L., Wang, J., & Wu, H. (2019) · Wiley eBooks · doi:10.1002/9783527818341.ch8 · Cited by 19
Lifetime risk of COPD: what will the future bring?
Mannino, D. M., & Martínez, F. J. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61188-4 · Cited by 15
Keller, T., Brem, S., Tran, V. T., Sritharan, O., Schäfer, D., & Schlücker, S. (2020) · Journal of Biophotonics · doi:10.1002/jbio.201960126 · Cited by 14
A Chronological Review of Potential Disease-Modifying Therapeutic Strategies for Alzheimer’s Disease
Ettcheto, M., Busquets, O., Espinosa-Jiménez, T., Verdaguer, E., Auladell, C., & Camins, A. (2020) · Current Pharmaceutical Design · doi:10.2174/1381612826666200211121416 · Cited by 13
Advancing dementia prevention through effective blood pressure control
Peters, R. K., & Anderson, C. S. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30407-7 · Cited by 10
Cited by
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Biosensors applications in medical field: A brief review
Haleem, A., Javaid, M., Singh, R. P., Suman, R., & Rab, S. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100100 · Cited by 600
Connected healthcare: Improving patient care using digital health technologies
Awad, A., Trenfield, S. J., Pollard, T. D., Ong, J. J., Elbadawi, M., McCoubrey, L. E., Goyanes, A., Gaisford, S., & Basit, A. W. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.113958 · Cited by 405
Wang, C., He, T., Zhou, H., Zhang, Z., & Lee, C. (2023) · Bioelectronic Medicine · doi:10.1186/s42234-023-00118-1 · Cited by 295
Theyagarajan, K., & Kim, Y.-J. (2024) · Biosensors · doi:10.3390/bios14100492 · Cited by 31
Metadata
- Authors
- Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-02-03
- Volume
- 15
- Issue
- 2
- Pages
- 1960-2004
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W3126222058
- Cited by
- 359
- References
- 344
- FWCI
- 17.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.