Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates
Open accessAbstract
The efficacy of implanted biomedical devices is often compromised by host recognition and subsequent foreign body responses. Here, we demonstrate the role of the geometry of implanted materials on their biocompatibility in vivo. In rodent and non-human primate animal models, implanted spheres 1.5 mm and above in diameter across a broad spectrum of materials, including hydrogels, ceramics, metals and plastics, significantly abrogated foreign body reactions and fibrosis when compared with smaller spheres. We also show that for encapsulated rat pancreatic islet cells transplanted into streptozotocin-treated diabetic C57BL/6 mice, islets prepared in 1.5-mm alginate capsules were able to restore blood-glucose control for up to 180 days, a period more than five times longer than for transplanted grafts encapsulated within conventionally sized 0.5-mm alginate capsules. Our findings suggest that the in vivo biocompatibility of biomedical devices can be significantly improved simply by tuning their spherical dimensions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 of 34 cited sources checked · 0 supported · 0 flagged
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“At 7 days post-transplantation a glucose tolerance test (GTT) was used to evaluate the kinetics of blood glucose correction and no significant delays were measured as a function of capsule geometry”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Western blot analysis of α-SMA expression within the cellular overgrowth on spheres showed a significant decrease as sphere size was increased”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“These findings were further validated through a multiplexed inflammatory mouse cytokine profile (Figure 2e).”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In rodent and non-human primate animal models, implanted spheres 1.5 mm and above in diameter across a broad spectrum of materials, including hydrogels, ceramics, metals, and plastics, significantly abrogated foreign body reactions and fibrosis when compared to smaller spheres.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“q-PCR expression analysis of fibrosis markers, collagen 1a1 (Col1a1), collagen 1a2 (Col1a2), and αSMA, verified that increasing sphere size resulted in a significant reduction of fibrosis formation directly on spheres”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“These analyses revealed that across all materials tested (SLG20 alginate, LF10/60 alginate, stainless steel, glass, polycaprolactone, and polystyrene) increasing sphere size led to a significant reduction of innate immune cell accumulation in peripheral tissue.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“q-PCR expression analysis of additional fibrosis markers, namely collagen 1a1 (Col1a1), collagen 1a2 (Col1a2), and αSMA, further indicated reduced cellular deposition as the sphere size was increased”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The difference in both BG normalization (Figure 4b) and fraction cured (Figure 4d) was significantly different (p<0.0001) between the 0.5 mm and 1.5 mm capsule groups following the initial failure in regulating BGs by the 0.5 mm group (~day 25) throughout the remainder of the experiment.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“We observed no significant differences in diffusion kinetics of glucose (Supplemental Figure S10) or insulin (Supplemental Figure S11) as a function of capsule geometry”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“We also show that for encapsulated rat pancreatic islet cells transplanted into streptozotocin-treated diabetic C57BL/6 mice, islets prepared in 1.5 mm alginate capsules were able to restore blood-glucose control for up to 180 days, a period more than 5-fold longer than for transplanted grafts encapsulated within conventionally sized 0.5-mm alginate capsules.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In contrast, expression of macrophage markers associated only with classical and wound-healing phenotypes was enriched on 1.5-mm spheres (Figure 5e and Supplemental Table S1).”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Significantly, alginate microspheres of 1.5 mm in diameter demonstrated an ability to ward off cellular deposition for at least 6 months.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Fibrotic tissue obtained directly from the 0.5 mm-sized s showed increasing expression of markers associated with all three macrophage phenotypes.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“At all time points evaluated, we observed a significant increase in the accumulation of myeloid cells onto 0.5 mm-sized spheres compared to the 1.5 mm-sized spheres (Figure 5a).”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“However, increased expression of markers associated with this macrophage phenotype was observed on days 4 and 7 in cells associated with the 0.5 mm spheres (Figure 5e).”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Confocal images acquired from retrieved 0.5 mm and 1.5 mm capsules showed positive Newport Green (islet viability marker) staining only in the 1.5 mm group”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Regulatory macrophage markers were not significantly up-regulated at any time point or in any compartment tested following implantation of 1.5 mm-sized spheres.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Implantation of both 0.5 mm- and 1.5 mm-sized spheres resulted in an increased expression of markers associated with a wound healing phenotype in the intraperitoneal and peripheral omentum fat compartments (Supplemental Figures S15 and S16, and Supplemental Table S1).”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“while we did not observe significant buildup of fibrosis on the capsules upon retrieval after 180 days”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“PDX1 expression results were further verified using qPCR analysis of RNA isolated from retrieved capsules, and an ~8-fold higher levels of rat Pdx1 was detectable in the 1.5 mm capsules compared to 0.5 mm capsules group”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“the mice in this treatment group lost blood glucose control after approximately 140 days.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesThe paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Combined our results suggest that grafts in 1.5 mm-sized capsules survived ~ 6 fold prolonged duration compared to those prepared in conventionally sized 0.5 mm capsules because the tuned geometry hydrogels were able to resists fibrosis for a longer duration.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Overall, we observed significantly different gene expression patterns for cells associated with these tissues following implantation of 0.5 mm-sized spheres when compared to 1.5 mm-sized spheres (Supplemental Table S1).”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Modulating the spherical dimensions of a broad spectrum of materials encompassing hydrogels, ceramics, metals, and plastics also showed that spheres of 1.5 mm in diameter or greater significantly mitigated foreign reactions and fibrosis.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In vivo Z-stacked intravital images obtained from implanted medium- and large-sized spheres at 1, 4, and 7 days post-implant indicate that macrophage cells extravasate from peripheral fat pad tissue and accumulate onto 0.5 mm spheres over that one week period, while very few macrophages can be observed near the 1.5 mm spheres (Figure 5d).”
- Also stated in: § Abstract · boosted
“Z-stacked and time lapse intravital images of macrophage accumulation onto 0.5 mm and 1.5 mm sized spheres at 1, 4, and 7 days post-implantation confirm both a lack of macrophage activity and numbers surrounding 1.5 mm size spheres, and significant macrophage activity and numbers around 0.5 mm sized spheres (Supplemental Videos V3–V8).”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Also stated in: § Abstract · boosted
None of the sources cited for this claim have been checked yet.
In the paper
“Notably, our evaluation of a spectrum of materials with a range of mechanical stiffness properties varying from soft (Alginate hydrogels, < 100 kPa)34 to hard (Stainless steel, 100s of GPa)35 demonstrates that size and shape rather than stiffness plays a critical role in biocompatibility.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [34] Papajova, E., Bujdos, M., Chorvat, D., Stach, M. & Lacik, I. Method for preparation of planar alginate hydrogels by external gelling using an aerosol of gelling solution. Carbohydr. Polym. 90, 472–482 (2012). source
- Not checked yetcites [35] Fujie, T. et al. Evaluation of substrata effect on cell adhesion properties using freestanding poly(L-lactic acid) nanosheets. Langmuir 27, 13173–13182 (2011). source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Rests on an assumption: Findings in rodents and non-human primates about foreign body response to implanted spheres translate to humans.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“These results suggest our size-dependent fibrotic response observations in C57BL/6 mice also translate to other larger rodent species.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Load-bearingStrength:hedged· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Our findings suggest that the in vivo biocompatibility of biomedical devices can be significantly improved by simply tuning their spherical dimensions.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Rests on an assumption: Findings in rodents and non-human primates about foreign body response to implanted spheres translate to humans.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“because the tuned geometry hydrogels were able to resists fibrosis for a longer duration.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIn the paper
“In this model, a macrophage Fas-induced apoptosis transgene enable inducible/reversible apoptosis of macrophages using the mouse colony stimulating factor 1 receptor promoter (Csf1r) to drive expression of a mutant human FK506 binding protein 1A, 12kDa42.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [42] Burnett, S. H. et al. Conditional macrophage ablation in transgenic mice expressing a Fas-based suicide gene. J. Leukocyte Biol. 75, 612–623 (2004). source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIn the paper
“however there is still no consensus on an ideal geometry21.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [21] Helton, K. L., Ratner, B. D. & Wisniewski, N. A. Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and the foreign body response-part I: Theoretical framework. J. Diabetes Sci. Technol. 5, 632–646 (2011). source
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Spherical materials that are of 1.5 mm in diameter or greater proved to be significantly more biocompatible compared to their smaller-sized or counterparts.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“We believe that these data are consistent with macrophage activation in these compartments, that is reduced when the implanted material are 1.5 mm spheres.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIn the paper
“Salthouse et al. described that implant shape can profoundly affect macrophage behavior at the interface of percutaneous implants and observed that smooth, well contoured implants with no acute angles are more biocompatible20.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [20] Salthouse, T. N. Some aspects of macrophage behavior at the implant interface. J. Biomed. Mater. Res. 18, 395–401 (1984). source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIn the paper
“this strain is known to produce a strong fibrotic and foreign body response similar to observations made in human patients31.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [31] Kolb, M. et al. Differences in the fibrogenic response after transfer of active transforming growth factor-β1 gene to lungs of “fibrosis-prone” and “fibrosis-resistant” mouse strains. Am. J. Respir. Cell Mol. Biol. 27, 141–150 (2002). source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesNone of the sources cited for this claim have been checked yet.
In the paper
“When implanted into the intraperitoneal space of non-human primates or immunocompetent rodents, alginate microspheres elicit foreign body reactions and fibrosis29, 30.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [29] Dang, T. T. et al. Spatiotemporal effects of a controlled-release anti-inflammatory drug on the cellular dynamics of host response. Biomaterials 32, 4464–4470 (2011). source
- Not checked yetcites [30] King, A., Sandler, S. & Andersson, A. The effect of host factors and capsule composition on the cellular overgrowth on implanted alginate capsules. J. Biomed. Mater. Res. 57, 374–383 (2001). source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Combined our observations suggest that a lack of regulatory macrophage cell accumulation on large size spheres correlates with the truncated fibrosis responses.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIn the paper
“To ensure proper biocompatibility assessment in our studies we used an immunocompetent C57BL/6 mouse model for our initial screening”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [31] Kolb, M. et al. Differences in the fibrogenic response after transfer of active transforming growth factor-β1 gene to lungs of “fibrosis-prone” and “fibrosis-resistant” mouse strains. Am. J. Respir. Cell Mol. Biol. 27, 141–150 (2002). source
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesNone of the sources cited for this claim have been checked yet.
In the paper
“Previously, we and others have shown that host recognition and fibrosis via cellular and collagen deposition on the surface of transplanted 0.5 mm sized alginate microcapsules results in encapsulated islet graft cell death and the failure of diabetic correction in STZ-treated C57BL/6 mice28, 37, 38.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [28] Dolgin, E. Encapsulate this. Nature Med. 20, 9–11 (2014). source
- Not checked yetcites [37] Dang, T. T. et al. Enhanced function of immuno-isolated islets in diabetes therapy by co-encapsulation with an anti-inflammatory drug. Biomaterials 34, 5792–5801 (2013). source
- Not checked yetcites [38] de Groot, M., Schuurs, T. A. & van Schilfgaarde, R. Causes of limited survival of microencapsulated pancreatic islet grafts. J. Surg. Res. 121, 141–150 (2004). source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIn the paper
“These results confirm that macrophages are indeed a key driver of the fibrotic responses we have observed in response to our transplanted materials.”
- Also stated in: § Abstract · hedged
“Macrophages have been implicated as key drivers of the foreign-body reaction to implanted materials41.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [41] Shi, C. & Pamer, E. G. Monocyte recruitment during infection and inflammation. Nature Rev. Immunol. 11, 762–774 (2011). source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Also stated in: § Abstract · hedged
None of the sources cited for this claim have been checked yet.
In the paper
“Host recognition and fibrosis of alginate capsules in humans, independent of donor tissue, is the key barrier to the clinical translation of encapsulated donor islets for treatment of type-1 diabetes26, 27, 28.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [26] Lim, F. & Sun, A. M. Microencapsulated islets as bioartificial endocrine pancreas. Science 210, 908–910 (1980). source
- Not checked yetcites [27] Scharp, D. W. & Marchetti, P. Encapsulated islets for diabetes therapy: History, current progress, and critical issues requiring solution. Adv. Drug Deliv. Rev. 67–68, 35–73 (2014). source
- Not checked yetcites [28] Dolgin, E. Encapsulate this. Nature Med. 20, 9–11 (2014). source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“This likely suggests some islet viability loss after transplantation, which could be related to the long-term durability of the rat islets used in this treatment model.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesA conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In summary, we have demonstrated that tuning the geometry of implanted materials we can influence their host recognition and propagation of foreign body reactions.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes
- It may state two separate claims as one. 19
- The quote only partly states this claim. 2
- Probably not a substantial claim. 8
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Z-stacked confocal imaging of the retrieved 1.5 mm spheres confirms minimal cellular deposition, a lack of immune macrophages, and fibrosis-associated activated myofibroblast coverage”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Immunofluorescence stained z-stacked confocal images of retrieved materials showed a significant decrease in macrophage (CD68) and myofibroblast (αSMA) deposition across all materials tested, and significantly, large SLG20 alginate, LF10/60 (endotoxin containing alginate), glass, and stainless steel spheres had negligible cellular deposition”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Dark field phase contrast images from retrieved capsules show that the 1.5 mm spheres are largely devoid of cellular deposition while the 0.3 mm sized spheres are covered with deposited cells and are clumped together in fibrotic tissue”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Bright-field images from retrieved materials 14 days post-implant revealed significant cellular deposition on the medium-sized versions of all materials tested. Interestingly, all materials tested at an increased size led to a marked reduction of the thickness of cellular overgrowth deposition”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Bright field and Z-stacked confocal images obtained from retrieved glass microspheres show that the large spheres are devoid of any cellular deposition while the smaller spheres are significantly clumped together and embedded within a thick fibrotic capsule”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The obtained in situ images reveal that the 1.5 mm-sized spheres remain translucent and are not embedded into host omentum/fat tissue after 14 days; conversely, the 0.5 mm sized spheres are impeded in to the omentum/fat tissue”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“All mice (n = 5) in the 0.5 mm capsule group failed (i.e. BG above 200 mg/dl for 3 consecutive measurements), on average, by 30 days following transplantation, while in the 1.5 mm capsule group (n = 5), stayed cured, on average, even until 175 days (greater than a 5-fold increase) post-transplantation”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Dark field imaging revealed that the 0.5 mm capsules were covered in cellular deposition and clumped but the 1.5 mm capsules were largely clean and void of cellular deposition”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“To ensure that the size-modulated fibrotic response effect is not simply a function of surface area, we implanted spheres of two sizes, 0.5 mm and 1.5 mm, normalized in total surface area.”
- Also stated in: § Abstract · plain
“Dark field phase contrast images of the retrieved spheres revealed only limited cellular deposition on the 1.5 mm-sized spheres and significant cellular deposition on the 0.5 mm sized spheres”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Also stated in: § Abstract · plain
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Dark field phase contrast images from retrieved spheres show a marked reduction in cellular deposition onto spheres as their size is increased”
- Also stated in: § Abstract · plain
“Interestingly, the larger spheres had significantly reduced fibrotic deposition”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesThe quote only partly states this claim.
- Also stated in: § Abstract · plain
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“At both 14 and 28 days post implantation retrieval time points the 1.5 mm-sized SLG20 alginate spheres were not embedded in host tissue and freely dissociated from the implant site upon incision with a biopsy punch”
- Also stated in: § Abstract · plain
“extensive embedding and fibrosis buildup (up to 100 μm thick) is visible enveloping the implanted cylinders and medium sized spheres.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one. The quote only partly states this claim.
- Also stated in: § Abstract · plain
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“4 out of 5 mice in the 0.5 mm capsule group had comparatively diminished PDX-1 expression and all 5 mice showed high levels of alpha smooth muscle expression; conversely, high levels of PDX-1 and minimal alpha smooth muscle actin were detected in capsules retrieved from all 5 mice in the 1.5 mm capsule group”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“This phenotype was elevated at day 4 for both sizes of spheres implanted in mice, and decreased by day 7 for the 1.5 mm-sized spheres.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Notably, on 1.5 mm-sized spheres we observed negligible numbers of neutrophil cells and a limited number of myeloid and macrophage cells at all time points.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Dark field microscope images of the retrieved spheres revealed only limited cellular deposition onto spheres implanted in mice with depleted macrophages and conversely significant cellular deposition onto spheres received from mice with macrophages (Supplemental Figure S13).”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In probing macrophage and neutrophil cells, by four days post-implantation we observed significantly increased accumulation on 0.5 mm-sized spheres, which appears to plateau by day 7 (Figure 5b and c).”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“Macrophage cells have remarkable plasticity that allows them to efficiently respond to environmental signals and change their phenotype to address the implicated stimuli43.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [43] Gordon, S. Alternative activation of macrophages. Nature Rev. Immunol. 3, 23–35 (2003). source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
None of the sources cited for this claim have been checked yet.
In the paper
“The surface roughness of material spheres we evaluated here only included relatively smooth surfaced materials (<1 μm roughness)32, 33.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [32] Lekka, M., Sainz-Serp, D., Kulik, A. J. & Wandrey, C. Hydrogel microspheres: Influence of chemical composition on surface morphology, local elastic properties, and bulk mechanical characteristics. Langmuir 20, 9968–9977 (2004). source
- Not checked yetcites [33] Shellenberger, K. & Logan, B. E. Effect of molecular scale roughness of glass beads on colloidal and bacterial deposition. Environ. Sci. Technol. 36, 184–189 (2002). source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
None of the sources cited for this claim have been checked yet.
In the paper
“At the macro level (>100 μm in size), it is generally held that thicker materials produce a proportionally higher magnitude of foreign body responses and fibrosis3, 21.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [3] Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H. & Schoenfisch, M. H. Biocompatible materials for continuous glucose monitoring devices. Chem. Rev. 113, 2528–2549 (2013). source
- Not checked yetcites [21] Helton, K. L., Ratner, B. D. & Wisniewski, N. A. Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and the foreign body response-part I: Theoretical framework. J. Diabetes Sci. Technol. 5, 632–646 (2011). source
Strength:hedged· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“Among the shapes tested, circular rods produced the least amount of foreign body responses followed by pentagonal, and then triangular.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [19] Matlaga, B. F., Yasenchak, L. P. & Salthouse, T. N. Tissue response to implanted polymers: The significance of sample shape. J. Biomed. Mater. Res. 10, 391–397 (1976). source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
None of the sources cited for this claim have been checked yet.
In the paper
“Meanwhile, a regulatory macrophage phenotype has been characterized to correlate with elevated expression of Interleukin 10 (IL10), TNF superfamily member 14 (Light), and Sphingosine Kinase 1 (Sphk1)44, 45, 46.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [44] Mosser, D. M. & Edwards, J. P. Exploring the full spectrum of macrophage activation. Nature Rev. Immunol. 8, 958–969 (2008). source
- Not checked yetcites [45] Murray, P. J. et al. Macrophage activation and polarization: Nomenclature and experimental guidelines. Immunity 41, 14–20 (2014). source
- Not checked yetcites [46] Gordon, S. & Martinez, F. O. Alternative activation of macrophages: Mechanism and functions. Immunity 32, 593–604 (2010). source
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“They found that increasing the size of implanted materials resulted in larger foreign body reactions, and the formation of a thicker layer of fibrosis around the implant23.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [23] Ward, W. K., Slobodzian, E. P., Tiekotter, K. L. & Wood, M. D. The effect of microgeometry, implant thickness and polyurethane chemistry on the foreign body response to subcutaneous implants. Biomaterials 23, 4185–4192 (2002). source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“Furthermore, an EGFP transgene included in this model enables the in situ fluorescent monitoring of macrophage cells42.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [42] Burnett, S. H. et al. Conditional macrophage ablation in transgenic mice expressing a Fas-based suicide gene. J. Leukocyte Biol. 75, 612–623 (2004). source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“There is a broad spectrum of macrophage activations which can be categorized into three states namely, classical activation (pro-inflammatory, MClassic), alternative activation (pro-healing, MWound), and regulatory activation (MReg)44.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [44] Mosser, D. M. & Edwards, J. P. Exploring the full spectrum of macrophage activation. Nature Rev. Immunol. 8, 958–969 (2008). source
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
None of the sources cited for this claim have been checked yet.
In the paper
“A pro-wound healing phenotype of macrophage correlates with up regulation in expression of Dendritic Cell Immune Receptor (Dcir), Stabilin 1 (Stab1), chemokine (C-C motif) ligand 22 (CCL22), Chitinase-like 3 (YM1), and Arginase 1 (Arg1)44, 45, 46.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [44] Mosser, D. M. & Edwards, J. P. Exploring the full spectrum of macrophage activation. Nature Rev. Immunol. 8, 958–969 (2008). source
- Not checked yetcites [45] Murray, P. J. et al. Macrophage activation and polarization: Nomenclature and experimental guidelines. Immunity 41, 14–20 (2014). source
- Not checked yetcites [46] Gordon, S. & Martinez, F. O. Alternative activation of macrophages: Mechanism and functions. Immunity 32, 593–604 (2010). source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“This effect was demonstrated to be independent of total implanted surface area and visible with all materials tested.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Further, our finding suggests that simply increasing implant size is insufficient to resist foreign body responses and that a spherical shape is also integral for resisting host fibrosis/rejection.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
None of the sources cited for this claim have been checked yet.
In the paper
“A pro-inflammatory macrophage phenotype correlates with elevated expression of Tumor Necrosis Factor α (TNF α), Interleukin 1 (IL1), and Interferon Regulatory Factor 5 (IRF5)44, 45, 46.”
§ Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates > Abstract
What the sources say
- Not checked yetcites [44] Mosser, D. M. & Edwards, J. P. Exploring the full spectrum of macrophage activation. Nature Rev. Immunol. 8, 958–969 (2008). source
- Not checked yetcites [45] Murray, P. J. et al. Macrophage activation and polarization: Nomenclature and experimental guidelines. Immunity 41, 14–20 (2014). source
- Not checked yetcites [46] Gordon, S. & Martinez, F. O. Alternative activation of macrophages: Mechanism and functions. Immunity 32, 593–604 (2010). source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
The paper relies on this without support.
No prior study has examined the effect of sphere diameter on biocompatibility.
“Interestingly, to our knowledge no one has studied the effect of sphere diameter on biocompatibility.”
The paper relies on this without support.
Larger 1.5 mm sized spherical capsules have not previously been evaluated for islet cell encapsulation.
“Thus, to our knowledge larger 1.5 mm sized spherical capsules have previously not been evaluated for islet cell encapsulation.”
The paper relies on this without support.
Findings in rodents and non-human primates about foreign body response to implanted spheres translate to humans.
“Our findings suggest that the in vivo biocompatibility of biomedical devices can be significantly improved by simply tuning their spherical dimensions.”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Smoother implant designs, avoiding sharp corners which can be particularly damaging to tissue when motion between the two occurs, can also be implemented to decrease tissue damage and chronic FBR (Veiseh et al., 2015).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Veiseh et al., 2015
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Interestingly, while decreasing the size of encapsulation devices down to the scale of individual islet microcapsules increases nutrient diffusion shortly after transplantation when compared to macroencapsulation devices, smaller capsule sizes have been shown to also induce a robust foreign body response and subsequent fibrosis.”
From Developments in stem cell-derived islet replacement therapy for treating type 1 diabetes (2023) · cites this paper as [103]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“This extensive study showed observation in size effect to be persistent in in vivo mouse, rat, and monkey models, implanting in both subcutaneous and intraperitoneal space, irrespective to the range of materials used, including alginate, stainless steel, glass, PCL, and polystyrene (PS).”
From Unraveling and Harnessing the Immune Response at the Cell–Biomaterial Interface for Tissue Engineering Purposes (2024) · cites this paper as [122]
The cited source says what the claim attributes to it.
In the citing paper
“However, these size observations are restricted to spherical shapes, as changing the geometry and increasing the biomaterial size provoked in contrast fibrosis or implant rejection.”
From Unraveling and Harnessing the Immune Response at the Cell–Biomaterial Interface for Tissue Engineering Purposes (2024) · cites this paper as [122]
The cited source says what the claim attributes to it.
In the citing paper
“Veiseh et al. supported this dimension effect, as spheres with a small diameter (≤0.5 mm) induced severe FBR, while large spheres (1.5 mm) scarcely provoked FBR.[ 122 ]”
From Unraveling and Harnessing the Immune Response at the Cell–Biomaterial Interface for Tissue Engineering Purposes (2024) · cites this paper as [122]
The cited source says what the claim attributes to it.
In the citing paper
“Spherical implants of 0.5 mm diameter generate higher degrees of FBR than larger 1.5 mm ones, an effect which is consistent for a wide range of materials (Veiseh et al., 2015).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Veiseh et al., 2015
The cited source says what the claim attributes to it.
In the citing paper
“Similarly, shape appears to directly influence FBR, with sharper edges generating more fibrosis than spherical implants (Veiseh et al., 2015).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Veiseh et al., 2015
In the citing paper
“recent evidence suggests that material geometry, or size and shape, may in fact dominate the overall response.5-7”
From Micro- and Nanopatterned Topographical Cues for Regulating Macrophage Cell Shape and Phenotype (2015) · cites this paper as [6]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Conflicting duration of blood-glucose control
MajorThe 1.5-mm capsule group is described as remaining cured on average until day 175, when the experiment stopped. Later, the paper says mice in that treatment group lost blood-glucose control after approximately 140 days.
“while in the 1.5 mm capsule group (n = 5), stayed cured, on average, even until 175 days (greater than a 5-fold increase) post-transplantation, when the experiment was stopped”
“Interestingly, while we did not observe significant buildup of fibrosis on the capsules upon retrieval after 180 days, however the mice in this treatment group lost blood glucose control after approximately 140 days.”
Figure 4c is assigned to two different results
MinorThe text cites Figure 4c for both histology of retrieved primate implants and a glucose-tolerance test of transplanted islets, leaving the panel's identity inconsistent.
“H&E stained sections of retrieved large spheres confirmed negligible cellular deposition and a lack of fibrosis (Figure 4c).”
“At 7 days post-transplantation a glucose tolerance test (GTT) was used to evaluate the kinetics of blood glucose correction and no significant delays were measured as a function of capsule geometry (Figure 4c).”
Citations
Cites
Exploring the full spectrum of macrophage activation
Mosser, D. M., & Edwards, J. P. (2008) · Nature Reviews Immunology · doi:10.1038/nri2448 · Cited by 9,144
Alginate: Properties and biomedical applications
Lee, K. Y., & Mooney, D. J. (2011) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.06.003 · Cited by 8,477
Macrophage activation and polarization: nomenclature and experimental guidelines
Murray, P. J., Allen, J. E., Biswas, S. K., Fisher, E. A., Gilroy, D. W., Goerdt, S., Gordon, S., Hamilton, J. A., Ivashkiv, L. B., Lawrence, T., et al. (2014) · Immunity · doi:10.1016/j.immuni.2014.06.008 · Cited by 6,337
Alternative activation of macrophages
Gordon, S. (2003) · Nature Reviews Immunology · doi:10.1038/nri978 · Cited by 6,189
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138
Alternative activation of macrophages: mechanism and functions
Gordon, S., & Martinez, F. O. (2010) · Immunity · doi:10.1016/j.immuni.2010.05.007 · Cited by 4,197
Monocyte recruitment during infection and inflammation
Shi, C., & Pamer, E. G. (2011) · Nature Reviews Immunology · doi:10.1038/nri3070 · Cited by 3,015
On the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772
Method for the Isolation of Intact Islets of Langerhans from the Rat Pancreas
Lacy, P. E., & Kostianovsky, M. (1967) · Diabetes · doi:10.2337/diab.16.1.35 · Cited by 2,741
Microencapsulated Islets as Bioartificial Endocrine Pancreas
Lim, F., & Sun, A. M. (1980) · Science · doi:10.1126/science.6776628 · Cited by 2,377
Flagged first, then by citations
Cited by
Sorted by citations
Hydrogel microparticles for biomedical applications
Daly, A. C., Riley, L., Segura, T., & Burdick, J. A. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0148-6 · Cited by 1,285
Soft Materials by Design: Unconventional Polymer Networks Give Extreme Properties
Zhao, X., Chen, X., Yuk, H., Lin, S., Liu, X., & Parada, G. A. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01088 · Cited by 1,177
Advances in Biomaterials for Drug Delivery
Fenton, O. S., Olafson, K. N., Pillai, P. S., Mitchell, M. J., & Langer, R. (2018) · Advanced Materials · doi:10.1002/adma.201705328 · Cited by 890
Self-citationFunctional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment
Huang, G., Li, F., Zhao, X., Ma, Y., Li, Y., Lin, M., Jin, G., Lu, T. J., Genin, G. M., & Xu, F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00094 · Cited by 825
Design of biodegradable, implantable devices towards clinical translation
Li, C., Guo, C., Fitzpatrick, V., Ibrahim, A. G. A., Zwierstra, M. J., Hanna, P. C., Lechtig, A., Nazarian, A., Lin, S. J., & Kaplan, D. L. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0150-z · Cited by 828
Metadata
- Authors
- Veiseh, O., Doloff, J. C., Ma, M., Vegas, A. J., Tam, H. H., Bader, A. R., Li, J., Langan, E., Wyckoff, J., Loo, W. S., Jhunjhunwala, S., Chiu, A., Siebert, S., Tang, K., Hollister-Lock, J., Aresta-Dasilva, S., Bochenek, M., Mendoza-Elias, J., Wang, Y., Qi, M., Lavin, D. M., Chen, M., Dholakia, N., Thakrar, R., Lacík, I., Weir, G. C., Oberholzer, J., Greiner, D. L., Langer, R., & Anderson, D. G.
- Affiliations
- Boston Children's Hospital (US)
- Koch Institute for Integrative Cancer Research At MIT (US)
- Massachusetts Institute of Technology (US)
- University of Illinois Chicago (US)
- Joslin Diabetes Center (US)
- University of Massachusetts Chan Medical School (US)
- Corresponding author
- Anderson, Daniel G.
- ORCID
- Venue
- Nature Materials
- Published
- 2015-05-18
- Volume
- 14
- Issue
- 6
- Pages
- 643-651
- ISSN
- 1476-1122 (ISSN-L)
- 1476-4660
- PMC
- PMC4477281
- OpenAlex
- W1482515349
- Cited by
- 897
- References
- 51
- Citations by year
- 2026: 63 · 2025: 71 · 2024: 77 · 2023: 79 · 2022: 72 · 2021: 118 · 2020: 107 · 2019: 98 · 2018: 67 · 2017: 69 · 2016: 65 · 2015: 11
- FWCI
- 71.23
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Nature Materials (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- eScholarship@UMassChan (acceptedVersion)
- Digital Access to Scholarship at Harvard (DASH) (Harvard University) (submittedVersion, cc-by)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc-sa)
- PMC
- Funders
- National Institutes of Health (4r37eb000244-34, 5u54ca119349-05)
- National Cancer Institute (U54CA151884, CA151884, P30CA014051, P30-CA-14051, U54 CA-119349)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK091526)
- National Institute of Biomedical Imaging and Bioengineering (EB-000244, R01EB000244, R37-EB000244, EB 000351, R01EB000351)
- National Institute of Dental and Craniofacial Research (DE013023, R01DE013023)
- Topics
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Keywords
- foreign body reaction, biocompatibility, implant geometry, islet transplantation, alginate capsules, streptozotocin-induced diabetes, fibrosis, hydrogels, ceramics, metals, plastics, non-human primates, rodent models
- MeSH terms
- Animals, Foreign-Body Reaction, Mice, Inbred C57BL, Primates, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-05, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-05 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review