Fabrication of sharp silicon hollow microneedles by deep-reactive ion etching towards minimally invasive diagnostics
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Microneedle technologies have the potential for expanding the capabilities of wearable health monitoring from physiology to biochemistry. This paper presents the fabrication of silicon hollow microneedles by a deep-reactive ion etching (DRIE) process, with the aim of exploring the feasibility of microneedle-based in-vivo monitoring of biomarkers in skin fluid. Such devices shall have the ability to allow the sensing elements to be integrated either within the needle borehole or on the backside of the device, relying on capillary filling of the borehole with dermal interstitial fluid (ISF) for transporting clinically relevant biomarkers to the sensor sites. The modified DRIE process was utilized for the anisotropic etching of circular holes with diameters as small as 30 μm to a depth of >300 μm by enhancing ion bombardment to efficiently remove the fluorocarbon passivation polymer. Afterward, isotropic wet and/or dry etching was utilized to sharpen the needle due to faster etching at the pillar top, achieving tip radii as small as 5 μm. Such sharp microneedles have been demonstrated to be sufficiently robust to penetrate porcine skin without needing any aids such as an impact-insertion applicator, with the needles remaining mechanically intact after repetitive penetrations. The capillary filling of DRIE-etched through-wafer holes with water has also been demonstrated, showing the feasibility of use to transport the analyte to the target sites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Prausnitz, M. R., & Langer, R. (2008) · Nature Biotechnology · doi:10.1038/nbt.1504 · Cited by 3,517
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Bioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998
Davis, S. P., Landis, B. J., Adams, Z. H., Allen, M. G., & Prausnitz, M. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.010 · Cited by 934
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
High aspect ratio silicon etch: A review
Wu, B., Kumar, A., & Pamarthy, S. (2010) · Journal of Applied Physics · doi:10.1063/1.3474652 · Cited by 749
Wiig, H., & Swartz, M. A. (2012) · Physiological Reviews · doi:10.1152/physrev.00037.2011 · Cited by 722
Evaluation of MEMS materials of construction for implantable medical devices
Kotzar, G., Freas, M., Abel, P., Fleischman, A., Roy, S., Zorman, C., Moran, J. M., & Melzak, J. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00007-8 · Cited by 439
Silicon micromachined hollow microneedles for transdermal liquid transport
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820293 · Cited by 413
Mechanisms of sampling interstitial fluid from skin using a microneedle patch
Samant, P. P., & Prausnitz, M. R. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716772115 · Cited by 363
Structure and Distribution of an Unrecognized Interstitium in Human Tissues
Benias, P. C., Wells, R. G., Sackey-Aboagye, B., Klavan, H., Reidy, J., Buonocore, D., Miranda, M., Kornacki, S., Wayne, M., Carr-Locke, D. L., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-23062-6 · Cited by 354
Chemical Etching of Silicon: IV . Etching Technology
Schwartz, B., & Robbins, H. (1976) · Journal of The Electrochemical Society · doi:10.1149/1.2132721 · Cited by 354
Microneedle array for transdermal biological fluid extraction and in situ analysis
Mukerjee, E. V., Collins, S. D., Isseroff, R. R., & Smith, R. L. (2004) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2003.11.008 · Cited by 340
Microneedles for Transdermal Biosensing: Current Picture and Future Direction
Ventrelli, L., Marsilio Strambini, L., & Barillaro, G. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500450 · Cited by 235
Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer
Griss, P., & Stemme, G. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.809959 · Cited by 232
Single-unit neural recording with active microelectrode arrays
Bai, Q., & Wise, K. D. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.936367 · Cited by 215
Hwang, S.-W., Park, G., Edwards, C., Corbin, E. A., Kang, S.-K., Cheng, H., Song, J.-K., Kim, J.-H., Yu, S., Ng, J., et al. (2014) · ACS Nano · doi:10.1021/nn500847g · Cited by 202
Roxhed, N., Gasser, T. C., Griss, P., Holzapfel, G. A., & Stemme, G. (2007) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2007.907461 · Cited by 199
Tran, B. Q., Miller, P. R., Taylor, R. M., Boyd, G., Mach, P. M., Rosenzweig, C. N., Baca, J. T., Polsky, R., & Glaros, T. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00642 · Cited by 198
Ribet, F., Stemme, G., & Roxhed, N. (2018) · Biomedical Microdevices · doi:10.1007/s10544-018-0349-6 · Cited by 181
Wafer-level 3D integration technology
Koester, S. J., Young, A. M., Yu, R. R., Purushothaman, S., Chen, K.-N., La Tulipe, D. C., Rana, N., Shi, L., Wordeman, M. R., & Sprogis, E. J. (2008) · IBM Journal of Research and Development · doi:10.1147/jrd.2008.5388565 · Cited by 178
Arrays of hollow out-of-plane microneedles for drug delivery
Stoeber, B., & Liepmann, D. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.844843 · Cited by 178
Design, Development, and Evaluation of a Novel Microneedle Array-based Continuous Glucose Monitor
Jina, A., Tierney, M. J., Tamada, J. A., McGill, S., Desai, S., Chua, B., Chang, A., & Christiansen, M. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814526191 · Cited by 176
Painless Drug Delivery Through Microneedle-Based Transdermal Patches Featuring Active Infusion
Roxhed, N., Samel, B., Nordquist, L., Griss, P., & Stemme, G. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.906492 · Cited by 151
Bicomponent Microneedle Array Biosensor for Minimally‐Invasive Glutamate Monitoring
Windmiller, J. R., Valdés‐Ramírez, G., Zhou, N., Zhou, M., Miller, P. R., Jin, C., Brozik, S. M., Polsky, R., Katz, E., Narayan, R., et al. (2011) · Electroanalysis · doi:10.1002/elan.201100361 · Cited by 129
Chua, B., Desai, S. P., Tierney, M. J., Tamada, J. A., & Jina, A. N. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.09.026 · Cited by 121
Recruitment and Collection of Dermal Interstitial Fluid Using a Microneedle Patch
Kolluru, C., Williams, M., Chae, J., & Prausnitz, M. R. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801262 · Cited by 117
Elastic modulus and viscoelastic properties of full thickness skin characterised at micro scales
Crichton, M. L., Chen, X., Huang, H., & Kendall, M. A. F. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.11.035 · Cited by 106
Human Suction Blister Fluid Composition Determined Using High-Resolution Metabolomics
Niedzwiecki, M. M., Samant, P., Walker, D. I., Tran, V., Jones, D. P., Prausnitz, M. R., & Miller, G. W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04073 · Cited by 99
Ranamukhaarachchi, S. A., Padeste, C., Dübner, M., Häfeli, U. O., Stoeber, B., & Cadarso, V. J. (2016) · Scientific Reports · doi:10.1038/srep29075 · Cited by 99
Johansson, O., Wang, L., Hilliges, M., & Liang, Y. (1999) · PubMed · Cited by 74
A wafer-scale etching technique for high aspect ratio implantable MEMS structures
Bhandari, R., Negi, S., Rieth, L., & Solzbacher, F. (2010) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2010.06.011 · Cited by 71
Ribet, F., Stemme, G., & Roxhed, N. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.007 · Cited by 69
Hypodermic-Needle-Like Hollow Polymer Microneedle Array: Fabrication and Characterization
Wang, P.-C., Paik, S., Kim, S.-H., & Allen, M. G. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2307320 · Cited by 42
Wang, P.-C., Paik, S., Chen, S., Rajaraman, S., Kim, S.-H., & Allen, M. G. (2013) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2013.2262587 · Cited by 41
A Systematic Study of Plasma Activation of Silicon Surfaces for Self Assembly
Kaya, S., Rajan, P., Dasari, H., Ingram, D. C., Jadwisienczak, W. M., & Rahman, F. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b08358 · Cited by 38
Norman, J. J., Gupta, J., Patel, S. R., Park, S., Jarrahian, C., Zehrung, D., & Prausnitz, M. R. (2013) · Drug Delivery and Translational Research · doi:10.1007/s13346-013-0184-5 · Cited by 24
Song, S., Na, J., Jang, M., Lee, H., Lee, H. L., Lim, Y., Choi, H.-J., & Chae, Y. (2019) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2019.8662522 · Cited by 9
Cited by
Enhancement strategies for transdermal drug delivery systems: current trends and applications
Ramadon, D., McCrudden, M. T. C., Courtenay, A. J., & Donnelly, R. F. (2022) · Drug Delivery and Translational Research · doi:10.1007/s13346-021-00909-6 · Cited by 649
Microneedle for transdermal drug delivery: current trends and fabrication
Jung, J. H., & Jin, S. G. (2021) · Journal of Pharmaceutical Investigation · doi:10.1007/s40005-021-00512-4 · Cited by 416
Hollow microneedles: A perspective in biomedical applications
Cárcamo-Martínez, Á., Mallon, B., Domínguez-Robles, J., Vora, L. K., Anjani, Q. K., & Donnelly, R. F. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.120455 · Cited by 285
Microneedle array systems for long-acting drug delivery
Vora, L. K., Moffatt, K., Tekko, I. A., Paredes, A. J., Volpe-Zanutto, F., Mishra, D., Peng, K., Raj Singh Thakur, R., & Donnelly, R. F. (2021) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2020.12.006 · Cited by 270
Lyu, S., Dong, Z., Xu, X., Bei, H.-P., Yuen, H.-Y., James Cheung, C.-W., Wong, M.-S., He, Y., & Zhao, X. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.04.003 · Cited by 266
Metadata
- Authors
- Li, Y., Zhang, H., Yang, R., Laffitte, Y., Schmill, U., Hu, W., Kaddoura, M., Blondeel, E. J. M., & Cui, B.
- Venue
- Microsystems & Nanoengineering
- Published
- 2019-08-26
- Volume
- 5
- Issue
- 1
- Pages
- 41-41
- ISSN
- 2055-7434 (ISSN-L)
- OpenAlex
- W2969303812
- Cited by
- 210
- References
- 41
- FWCI
- 7.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.