CoChat

Tissue clearing and its applications in neuroscience

Open access
Ueda, Hiroki R., Ertürk, Ali, Chung, Kwanghun, Gradinaru, Viviana, Chédotal, Alain, Tomancak, Pavel, Keller, Philipp J. · 2020 · Nature Reviews Neuroscience
Cited by 609

The DOI matches its Crossref record; 165 of the 165 references it cites were found in a registry or an index.

Abstract

State-of-the-art tissue-clearing methods provide subcellular-level optical access to intact tissues from individual organs and even to some entire mammals. When combined with light-sheet microscopy and automated approaches to image analysis, existing tissue-clearing methods can speed up and may reduce the cost of conventional histology by several orders of magnitude. In addition, tissue-clearing chemistry allows whole-organ antibody labelling, which can be applied even to thick human tissues. By combining the most powerful labelling, clearing, imaging and data-analysis tools, scientists are extracting structural and functional cellular and subcellular information on complex mammalian bodies and large human specimens at an accelerated pace. The rapid generation of terabyte-scale imaging data furthermore creates a high demand for efficient computational approaches that tackle challenges in large-scale data analysis and management. In this Review, we discuss how tissue-clearing methods could provide an unbiased, system-level view of mammalian bodies and human specimens and discuss future opportunities for the use of these methods in human neuroscience. Tissue-clearing methods are now allowing 3D imaging of intact tissues and some entire mammals. In this Review, Ueda and colleagues discuss the various tissue-clearing methods, related techniques and data analysis and management, as well as the application of these methods in neuroscience.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41583-019-0250-1

Cites

165 of 165 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 17

  1. Amiya, T. & Tanaka, T. Phase transitions in crosslinked gels of natural polymers. Macromolecules 20, 1162–1164 (1987). · doi:10.1021/ma00171a050
  2. Chance, B., Liu, H., Kitai, T. & Zhang, Y. Effects of solutes on optical properties of biological materials: models, cells, and tissues. Anal. Biochem. 227, 351–362 (1995). · doi:10.1006/abio.1995.1291
  3. Swoger, J., Verveer, P., Greger, K., Huisken, J. & Stelzer, E. H. Multi-view image fusion improves resolution in three-dimensional microscopy. Opt. Express 15, 8029–8042 (2007). · DOI
  4. Royer, L. A., Lemon, W. C., Chhetri, R. K. & Keller, P. J. A practical guide to adaptive light-sheet microscopy. Nat. Protoc. 13, 2462–2500 (2018). · DOI
  5. Cheeseman, B. L., Günther, U., Susik, M., Gonciarz, K. & Sbalzarini, I. F. Forget pixels: adaptive particle representation of fluorescence microscopy images. Nat. Commun. 9, 5160 (2018). · doi:10.1038/s41467-018-07390-9
  6. Bogovic, J. A., Hanslovsky, P., Wong, A. & Saalfeld, S. in 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI) 1123–1126 (IEEE, 2016).
  7. Sommer, C. S., Kothe C., Hamprecht U. & Ilastik F. A. in 2011 IEEE International Symposium on Biomedical Imaging: From Nano to Macro 230–233 (IEEE, 2011).
  8. Tuchin, V. V. et al. Optics of living tissues with controlled scattering properties. Proc. SPIE 3863, 10–21 (1999).
  9. Xu, X., Wang, R. K., Elder, J. B. & Tuchin, V. V. Effect of dextran-induced changes in refractive index and aggregation on optical properties of whole blood. Phys. Med. Biol. 48, 1205–1221 (2003). · DOI
  10. Liu, H., Beauvoit, B., Kimura, M. & Chance, B. Dependence of tissue optical properties on solute-induced changes in refractive index and osmolarity. J. Biomed. Opt. 1, 200–211 (1996). · DOI
  11. Vargas, G., Chan, K. F., Thomsen, S. L. & Welch, A. J. Use of osmotically active agents to alter optical properties of tissue: effects on the detected fluorescence signal measured through skin. Lasers Surg. Med. 29, 213–220 (2001). · doi:10.1002/lsm.1110
  12. Wang, R. K., Xu, X., Tuchin, V. V. & Elder, J. B. Concurrent enhancement of imaging depth and contrast for optical coherence tomography by hyperosmotic agents. JOSA B 18, 948–953 (2001). · doi:10.1364/josab.18.000948
  13. Xu, X. & Wang, R. K. The role of water desorption on optical clearing of biotissue: studied with near infrared reflectance spectroscopy. Med. Phys. 30, 1246–1253 (2003). · doi:10.1118/1.1576228
  14. Choi, B. et al. Determination of chemical agent optical clearing potential using in vitro human skin. Lasers Surg. Med. 36, 72–75 (2005). · doi:10.1002/lsm.20116
  15. Diogo, R., Siomava, N. & Gitton, Y. Development of human limb muscles based on whole-mount immunostaining and the links between ontogeny and evolution. Development 146, dev180349 (2019). · doi:10.1242/dev.180349
  16. Engelbrecht, C. J. & Stelzer, E. H. Resolution enhancement in a light-sheet-based microscope (SPIM). Opt. Lett. 31, 1477–1479 (2006). · doi:10.1364/ol.31.001477
  17. Hasegawa, J. et al. Three-dimensional imaging of plant organs using a simple and rapid transparency technique. Plant Cell Physiol. 57, 462–472 (2016). · DOI

Cited by

See all 609

Metadata

Authors
Ueda, H. R., Ertürk, A., Chung, K., Gradinaru, V., Chédotal, A., Tomancak, P., & Keller, P. J.
Venue
Nature Reviews Neuroscience
Published
2020-01-02
Volume
21
Issue
2
Pages
61-79
ISSN
  • 1471-003X (ISSN-L)
  • 1471-0048
OpenAlex
W2998583117
Cited by
609
References
165
FWCI
9.21
Type
journal article
Language
en
Open access
green
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.