A somatotopic bidirectional hand prosthesis with transcutaneous electrical nerve stimulation based sensory feedback
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
According to amputees, sensory feedback is amongst the most important features lacking from commercial prostheses. Although restoration of touch by means of implantable neural interfaces has been achieved, these approaches require surgical interventions, and their long-term usability still needs to be fully investigated. Here, we developed a non-invasive alternative which maintains some of the advantages of invasive approaches, such as a somatotopic sensory restitution scheme. We used transcutaneous electrical nerve stimulation (TENS) to induce referred sensations to the phantom hand of amputees. These sensations were characterized in four amputees over two weeks. Although the induced sensation was often paresthesia, the location corresponded to parts of the innervation regions of the median and ulnar nerves, and electroencephalographic (EEG) recordings confirmed the presence of appropriate responses in relevant cortical areas. Using these sensations as feedback during bidirectional prosthesis control, the patients were able to perform several functional tasks that would not be possible otherwise, such as applying one of three levels of force on an external sensor. Performance during these tasks was high, suggesting that this approach could be a viable alternative to the more invasive solutions, offering a trade-off between the quality of the sensation, and the invasiveness of the intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Advances in neural information processing systems 7
Cios, K., & Shields, M. (1997) · Neurocomputing · doi:10.1016/s0925-2312(97)90018-7 · Cited by 22,059
Nonparametric statistical testing of EEG- and MEG-data
Maris, E., & Oostenveld, R. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.024 · Cited by 8,496
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
The five percent electrode system for high-resolution EEG and ERP measurements
Oostenveld, R., & Praamstra, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00527-7 · Cited by 1,909
Upper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111
The perception of phantom limbs. The D. O. Hebb lecture
Ramachandran, V. (1998) · Brain · doi:10.1093/brain/121.9.1603 · Cited by 1,064
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Self-citationAnalysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Transcutaneous electrical nerve stimulation: Basic science mechanisms and clinical effectiveness
Sluka, K. A., & Walsh, D. (2003) · The Journal of Pain · doi:10.1054/jpai.2003.434 · Cited by 809
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Kaas, J. H., Merzenich, M. M., & Killackey, H. P. (1983) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.06.030183.001545 · Cited by 661
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
Ortiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Scheeringa, R., Fries, P., Petersson, K.-M., Oostenveld, R., Grothe, I., Norris, D. G., Hagoort, P., & Bastiaansen, M. C. M. (2011) · Neuron · doi:10.1016/j.neuron.2010.11.044 · Cited by 446
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Electroencephalographic Brain Dynamics Following Manually Responded Visual Targets
Makeig, S., Delorme, A., Westerfield, M., Jung, T.-P., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2004) · PLoS Biology · doi:10.1371/journal.pbio.0020176 · Cited by 357
Upper limb amputees can be induced to experience a rubber hand as their own
Ehrsson, H. H., Rosen, B., Stockselius, A., Ragno, C., Kohler, P., & Lundborg, G. (2008) · Brain · doi:10.1093/brain/awn297 · Cited by 343
Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335
Oddo, C. M., Raspopovic, S., Artoni, F., Mazzoni, A., Spigler, G., Petrini, F., Giambattistelli, F., Vecchio, F., Miraglia, F., Zollo, L., et al. (2016) · eLife · doi:10.7554/elife.09148 · Cited by 332
Self-citationDavis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314
Allison, T., McCarthy, G., & Wood, C. C. (1992) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(92)90082-m · Cited by 278
Muniak, M. A., Ray, S., Hsiao, S. S., Dammann, J. F., & Bensmaia, S. J. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.1486-07.2007 · Cited by 235
Electrocutaneous Stimulation for Sensory Communication in Rehabilitation Engineering
Szeto, A. Y. J., & Saunders, F. A. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324948 · Cited by 223
Antfolk, C., D'Alonzo, M., Controzzi, M., Lundborg, G., Rosen, B., Sebelius, F., & Cipriani, C. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2217989 · Cited by 194
Surveying the interest of individuals with upper limb loss in novel prosthetic control techniques
Engdahl, S. M., Christie, B. P., Kelly, B., Davis, A., Chestek, C. A., & Gates, D. H. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0044-2 · Cited by 179
Bionic Limbs: Clinical Reality and Academic Promises
Farina, D., & Aszmann, O. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3010453 · Cited by 157
Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156
Medical progress through technology
Publishers, K. A. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513298 · Cited by 146
Chai, G., Sui, X., Li, S., He, L., & Lan, N. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066002 · Cited by 131
Dosen, S., Markovic, M., Strbac, M., Belic, M., Kojic, V., Bijelic, G., Keller, T., & Farina, D. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2550864 · Cited by 121
A model for transcutaneous current stimulation: simulations and experiments
Kühn, A., Keller, T., Lawrence, M., & Morari, M. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0422-z · Cited by 117
Bilateral representations of touch in the primary somatosensory cortex
Tamè, L., Braun, C., Holmes, N. P., Farnè, A., & Pavani, F. (2016) · Cognitive Neuropsychology · doi:10.1080/02643294.2016.1159547 · Cited by 113
RELICA: A method for estimating the reliability of independent components
Artoni, F., Menicucci, D., Delorme, A., Makeig, S., & Micera, S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.09.010 · Cited by 107
Self-citationGonzalez, J., Soma, H., Sekine, M., & Yu, W. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-33 · Cited by 87
Hearing as substitution for sensation: A new principle for artificial sensibility
Lundborg, G., Rosén, B., & Lindberg, S. (1999) · The Journal Of Hand Surgery · doi:10.1053/jhsu.1999.0219 · Cited by 78
Stiffness Feedback for Myoelectric Forearm Prostheses Using Vibrotactile Stimulation
Witteveen, H. J. B., Luft, F., Rietman, J. S., & Veltink, P. H. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2267394 · Cited by 76
Anani, A. B., Ikeda, K., & Körner, L. M. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457988 · Cited by 74
Zhang, D., Xu, H., Shull, P. B., Liu, J., & Zhu, X. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0037-1 · Cited by 69
Chai, G., Zhang, D., & Zhu, X. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2580905 · Cited by 67
Hartmann, C., Dosen, S., Amsuess, S., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2357175 · Cited by 64
Time-division multiplexing for myoelectric closed-loop control using electrotactile feedback
Dosen, S., Schaeffer, M.-C., & Farina, D. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-138 · Cited by 55
Zhang, D., Xu, F., Xu, H., Shull, P. B., & Zhu, X. (2016) · International Journal of Neural Systems · doi:10.1142/s0129065716500064 · Cited by 50
Genna, C., Oddo, C. M., Fanciullacci, C., Chisari, C., Jörntell, H., Artoni, F., & Micera, S. (2017) · Brain Topography · doi:10.1007/s10548-017-0569-8 · Cited by 40
Self-citationAnani, A., & Körner, L. K. (1979) · PubMed · Cited by 33
Menicucci, D., Artoni, F., Bedini, R., Pingitore, A., Passera, M., Landi, A., L’Abbate, A., Sebastiani, L., & Gemignani, A. (2013) · Brain Topography · doi:10.1007/s10548-013-0349-z · Cited by 32
Self-citationUnderstanding body representations
Medina, J., & Coslett, H. B. (2016) · Cognitive Neuropsychology · doi:10.1080/02643294.2016.1197195 · Cited by 30
No somatotopy of sensorimotor alpha-oscillation responses to differential finger stimulation
Nierula, B., Hohlefeld, F. U., Curio, G., & Nikulin, V. V. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.025 · Cited by 29
A Novel Method to Generate Amplitude-Frequency Modulated Vibrotactile Stimulation
Dosen, S. S., Ninu, A., Yakimovich, T., Dietl, H., & Farina, D. (2015) · IEEE Transactions on Haptics · doi:10.1109/toh.2015.2497229 · Cited by 28
ErpICASSO: A tool for reliability estimates of independent components in EEG event-related analysis
Artoni, F., Gemignani, A., Sebastiani, L., Bedini, R., Landi, A., & Menicucci, D. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6345945 · Cited by 27
Self-citationREMOV: EEG artifacts removal methods during Lokomat lower-limb rehabilitation
Artoni, F., Chisari, C., Menicucci, D., Fanciullacci, C., & Micera, S. (2012) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290835 · Cited by 26
Self-citationSebastiani, L., Castellani, E., Gemignani, A., Artoni, F., & Menicucci, D. (2015) · Brain Research · doi:10.1016/j.brainres.2015.06.042 · Cited by 13
Self-citation
Research works printed but not linked: 1
- Ehrsson, H. H. et al. Upper limb amputees can be induced to experience a rubber hand as their own. Brain 131(no. 12), 3443–3452 (2008). · DOI · Paper page
Cited by
A soft neuroprosthetic hand providing simultaneous myoelectric control and tactile feedback
Gu, G., Zhang, N., Xu, H., Lin, S., Yu, Y., Chai, G., Ge, L., Yang, H., Shao, Q., Sheng, X., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00767-0 · Cited by 431
George, J. A., Kluger, D. T., Davis, T. S., Wendelken, S. M., Okorokova, E. V., He, Q., Duncan, C. C., Hutchinson, D. T., Thumser, Z. C., Beckler, D. T., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aax2352 · Cited by 388
A closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback
D’Anna, E., Valle, G., Mazzoni, A., Strauss, I., Iberite, F., Patton, J., Petrini, F. M., Raspopovic, S., Granata, G., Di Iorio, R., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aau8892 · Cited by 321
Self-citationToward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationRestoration of sensory information via bionic hands
Bensmaia, S. J., Tyler, D. J., & Micera, S. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00630-8 · Cited by 257
Self-citation
Metadata
- Authors
- D’Anna, E., Petrini, F. M., Artoni, F., Popovic, I., Simanić, I., Raspopovic, S., & Micera, S.
- Venue
- Scientific Reports
- Published
- 2017-09-07
- Volume
- 7
- Issue
- 1
- Pages
- 10930-10930
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2751515399
- Cited by
- 215
- References
- 56
- FWCI
- 6.17
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.