Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 411

The DOI matches its Crossref record.

Reduction to Normal of Plasma Glucose in Juvenile Diabetes by Subcutaneous Administration of Insulin with a Portable Infusion Pump

Tamborlane, William V., Sherwin, Robert S., Genel, Myron, Felig, Philip·1979·New England Journal of Medicine

Abstract

To improve plasma glucose control, we administered insulin via the subcutaneous route in seven ambulatory patients with juvenile diabetes (12 to 17 years of age), using a portable infusion pump at a basal rate with pulse-dose increments before meals. After two to four days, the mean plasma glucose (+/- 1 S.E.) of 94 +/- 5 mg per deciliter was markedly lower than when insulin was given by conventional methods in the patients' usual dose (243 +/- 28, P less than 0.01) or in a total dose equivalent to that administered with the pump (150 +/- 15, P less than 0.01). Maximal fluctuations in plasma glucose were also 50 to 150 mg per deciliter below those observed with conventional treatment (P less than 0.001). Glycosuria was eliminated in six of seven patients during pump treatment. None of the subjects had hypoglycemia. These results demonstrate that plasma glucose can be lowered to normal in ambulatory patients with brittle juvenile diabetes using a portable, subcutaneous insulin infusion system for two to four days. The feasibility and value of the long-term application of this technic need exploration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm197903153001101

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 23

  1. 10.1056/NEJM197604292941811 · DOI · Paper page
  2. 10.1056/NEJM197705052961812 · DOI
  3. 10.1056/NEJM197705262962111 · DOI
  4. Service, 1970, Diabetes, 19, 644, 10.2337/diab.19.9.644 · DOI · Paper page
  5. Molnar, 1972, Mayo Clin Proc, 47, 709
  6. 10.1055/s-0028-1093738 · DOI
  7. Albisser, 1974, Diabetes, 23, 397, 10.2337/diab.23.5.397 · DOI · Paper page
  8. 10.1055/s-0028-1093841 · DOI
  9. 10.1007/BF01219712 · DOI
  10. 10.2337/diabetes.26.6.571 · DOI
  11. 10.1007/BF01220633 · DOI
  12. Hepp, 1977, Horm Metab Res [Suppl], 7, 72
  13. Service, 1978, J Lab Clin Med, 91, 480
  14. 10.1136/bmj.1.6107.204 · DOI · Paper page
  15. 10.1016/S0140-6736(57)92595-3 · DOI · Paper page
  16. 10.1007/BF01218495 · DOI · Paper page
  17. 10.1111/j.0954-6820.1965.tb01810.x · DOI · Paper page
  18. Snedecor GW, Cochran WG: Statistical Methods. Sixth edition. Ames, Iowa State University Press, 1967
  19. Shima, 1977, Diabetes, 26, 717, 10.2337/diab.26.8.717 · DOI
  20. 10.1210/jcem-47-5-1160 · DOI
  21. 10.1172/JCI106989 · DOI · Paper page
  22. 10.1007/BF00425888 · DOI · Paper page
  23. 10.7326/0003-4819-79-6-812 · DOI

Cited by

Metadata

Authors
Tamborlane, W. V., Sherwin, R. S., Genel, M., & Felig, P.
Venue
New England Journal of Medicine
Published
1979-03-15
Volume
300
Issue
11
Pages
573-578
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2327215697
Cited by
411
References
0
FWCI
31.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.