The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Novel optical approach to atomic force microscopy
Abstract
A sensitive and simple optical method for detecting the cantilever deflection in atomic force microscopy is described. The method was incorporated in an atomic force microscope, and imaging and force measurements, in ultrahigh vacuum, were successfully performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Atomic force microscope–force mapping and profiling on a sub 100-Å scale
Martin, Y., Williams, C. C., & Wickramasinghe, H. K. (1987) · Journal of Applied Physics · doi:10.1063/1.338807 · Cited by 1,428
The measurement of van der Waals dispersion forces in the range 1.5 to 130 nm
Israelachvili, J. N., & Tabor, D. (1972) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1972.0162 · Cited by 672
Cited by
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Direct measurement of colloidal forces using an atomic force microscope
Ducker, W. A., Senden, T. J., & Pashley, R. M. (1991) · Nature · doi:10.1038/353239a0 · Cited by 2,075
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Cantilever transducers as a platform for chemical and biological sensors
Lavrik, N. V., Sepaniak, M. J., & Datskos, P. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1763252 · Cited by 1,117
Imaging Crystals, Polymers, and Processes in Water with the Atomic Force Microscope
Drake, B., Prater, C. B., Weisenhorn, A. L., Gould, S. A. C., Albrecht, T. R., Quate, C. F., Cannell, D. S., Hansma, H. G., & Hansma, P. K. (1989) · Science · doi:10.1126/science.2928794 · Cited by 1,033
Direct Measurement of the Forces Between Complementary Strands of DNA
Lee, G. U., Chrisey, L. A., & Colton, R. J. (1994) · Science · doi:10.1126/science.7973628 · Cited by 764
(1996) · Handbook of Microscopy · doi:10.1002/9783527620524.ch13 · Cited by 726
Scanning Tunneling Microscopy and Atomic Force Microscopy: Application to Biology and Technology
Hansma, P. K., Elings, V. B., Marti, O., & Bracker, C. E. (1988) · Science · doi:10.1126/science.3051380 · Cited by 716
Velocity Dependence of Atomic Friction
Gnecco, E., Bennewitz, R., Gyalog, T., Loppacher, C., Bammerlin, M., Meyer, E., & Güntherodt, H.-J. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.1172 · Cited by 649
Forces in atomic force microscopy in air and water
Weisenhorn, A. L., Hansma, P. K., Albrecht, T. R., & Quate, C. F. (1989) · Applied Physics Letters · doi:10.1063/1.101024 · Cited by 632
Improved fiber-optic interferometer for atomic force microscopy
Rugar, D., Mamin, H. J., & Guethner, P. (1989) · Applied Physics Letters · doi:10.1063/1.101987 · Cited by 629
Rugar, D., & Hansma, P. (1990) · Physics Today · doi:10.1063/1.881238 · Cited by 589
Attogram detection using nanoelectromechanical oscillators
Ilic, B., Craighead, H. G., Krylov, S., Senaratne, W., Ober, C., & Neuzil, P. (2004) · Journal of Applied Physics · doi:10.1063/1.1650542 · Cited by 585
The emergence of multifrequency force microscopy
Garcia, R., & Herruzo, E. T. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.38 · Cited by 577
High-speed atomic force microscopy for nano-visualization of dynamic biomolecular processes
Ando, T., Uchihashi, T., & Fukuma, T. (2008) · Progress in Surface Science · doi:10.1016/j.progsurf.2008.09.001 · Cited by 558
Using force modulation to image surface elasticities with the atomic force microscope
Maivald, P., Butt, H. J., Gould, S. A. C., Prater, C. B., Drake, B., Gurley, J. A., Elings, V. B., & Hansma, P. K. (1991) · Nanotechnology · doi:10.1088/0957-4484/2/2/004 · Cited by 525
Noy, A., Vezenov, D. V., & Lieber, C. M. (1997) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.27.1.381 · Cited by 478
Single cell detection with micromechanical oscillators
Ilic, B., Czaplewski, D., Zalalutdinov, M., Craighead, H. G., Neuzil, P., Campagnolo, C., & Batt, C. (2001) · Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena · doi:10.1116/1.1421572 · Cited by 443
Ziegler, C. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2694-y · Cited by 414
Atomic-Resolution Electrochemistry with the Atomic Force Microscope: Copper Deposition on Gold
Manne, S., Hansma, P. K., Massie, J., Elings, V. B., & Gewirth, A. A. (1991) · Science · doi:10.1126/science.251.4990.183 · Cited by 411
Biological applications of atomic force microscopy
Lal, R., & John, S. A. (1994) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1994.266.1.c1 · Cited by 402
Imaging and manipulation of biological structures with the AFM
Fotiadis, D. (2002) · Micron · doi:10.1016/s0968-4328(01)00026-9 · Cited by 390
Fukuma, T., Kimura, M., Kobayashi, K., Matsushige, K., & Yamada, H. (2005) · Review of Scientific Instruments · doi:10.1063/1.1896938 · Cited by 387
AFM: a versatile tool in biophysics
Alessandrini, A., & Facci, P. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/6/r01 · Cited by 384
Scanning Tunneling Microscopy and Atomic Force Microscopy in Organic Chemistry
Frommer, J. (1992) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199212981 · Cited by 383
Combined Scanning Electrochemical−Atomic Force Microscopy
Macpherson, J. V., & Unwin, P. R. (2000) · Analytical Chemistry · doi:10.1021/ac990921w · Cited by 383
The qPlus sensor, a powerful core for the atomic force microscope
Giessibl, F. J. (2019) · Review of Scientific Instruments · doi:10.1063/1.5052264 · Cited by 358
High-speed atomic force microscopy coming of age
Ando, T. (2012) · Nanotechnology · doi:10.1088/0957-4484/23/6/062001 · Cited by 355
Stimulated Emission Depletion Microscopy
Blom, H., & Widengren, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00653 · Cited by 339
Lateral, normal, and longitudinal spring constants of atomic force microscopy cantilevers
Neumeister, J. M., & Ducker, W. A. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144646 · Cited by 334
Photothermal spectroscopy with femtojoule sensitivity using a micromechanical device
Barnes, J. R., Stephenson, R. J., Welland, M. E., Gerber, C., & Gimzewski, J. K. (1994) · Nature · doi:10.1038/372079a0 · Cited by 327
Biological atomic force microscopy: what is achieved and what is needed
Shao, Z., Mou, J., Czajkowsky, D. M., Yang, J., & Yuan, J.-Y. (1996) · Advances in Physics · doi:10.1080/00018739600101467 · Cited by 325
Bian, K., Gerber, C., Heinrich, A. J., Müller, D. J., Scheuring, S., & Jiang, Y. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00033-2 · Cited by 314
Introduction to Scanning Tunneling Microscopy
Chen, C. J. (2007) · doi:10.1093/acprof:oso/9780199211500.001.0001 · Cited by 276
Techniques for measuring surface forces
Claesson, P. M., Ederth, T., Bergeron, V., & Rutland, M. W. (1996) · Advances in Colloid and Interface Science · doi:10.1016/0001-8686(96)00302-8 · Cited by 260
Thermal imaging using the atomic force microscope
Majumdar, A., Carrejo, J. P., & Lai, J. (1993) · Applied Physics Letters · doi:10.1063/1.109335 · Cited by 254
Fritz, J. (2008) · The Analyst · doi:10.1039/b718174d · Cited by 254
Mullin, N., & Hobbs, J. K. (2014) · Review of Scientific Instruments · doi:10.1063/1.4901221 · Cited by 58
Metadata
- Authors
- Meyer, G., & Amer, N. M.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1988-09-19
- Volume
- 53
- Issue
- 12
- Pages
- 1045-1047
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1992984362
- Cited by
- 1,290
- References
- 3
- FWCI
- 10.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.