The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Short cantilevers for atomic force microscopy
Abstract
We have designed and tested a family of silicon nitride cantilevers ranging in length from 23 to 203 μm. For each, we measured the frequency spectrum of thermal motion in air and water. Spring constants derived from thermal motion data agreed fairly well with the added mass method; these and the resonant frequencies showed the expected increase with decreasing cantilever length. The effective cantilever density (calculated from the resonant frequencies) was 5.0 g/cm3, substantially affected by the mass of the reflective gold coating. In water, resonant frequencies were 2 to 5 times lower and damping was 9 to 24 times higher than in air. Thermal motion at the resonant frequency, a measure of noise in tapping mode atomic force microscopy, decreased about two orders of magnitude from the longest to the shortest cantilever. The advantages of the high resonant frequency and low noise of a short (30 μm) cantilever were demonstrated in tapping mode imaging of a protein sample in buffer. Low-noise images were taken with feedback at a rate of about 0.5 frames/s. Given proper setpoint adjustment, the sample was not damaged, despite this cantilever’s high spring constant of 1.3 N/m. Without feedback, images were taken at 1.5 frames/s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Self-citationCalculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Method for the calibration of atomic force microscope cantilevers
Sader, J. E., Larson, I., Mulvaney, P., & White, L. R. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145439 · Cited by 1,000
Tapping mode atomic force microscopy in liquids
Hansma, P. K., Cleveland, J. P., Radmacher, M., Walters, D. A., Hillner, P. E., Bezanilla, M., Fritz, M., Vie, D., Hansma, H. G., Prater, C. B., et al. (1994) · Applied Physics Letters · doi:10.1063/1.111795 · Cited by 875
Self-citationMicrofabrication of cantilever styli for the atomic force microscope
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F. (1990) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576520 · Cited by 747
(1996) · Handbook of Microscopy · doi:10.1002/9783527620524.ch13 · Cited by 726
Fractured polymer/silica fiber surface studied by tapping mode atomic force microscopy
Zhong, Q., Inniss, D., Kjoller, K., & Elings, V. B. (1993) · Surface Science Letters · doi:10.1016/0167-2584(93)90906-y · Cited by 628
Self-citationScanning force microscopy - With Applications to Electric, Magnetic and Atomic Forces
Sarid, D., Coratger, R., Ajustron, F., & Beauvillain, J. (1991) · Microscopy Microanalysis Microstructures · doi:10.1051/mmm:0199100206064900 · Cited by 563
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Sader, J. E. (1998) · Journal of Applied Physics · doi:10.1063/1.368002 · Cited by 1,410
Cantilever transducers as a platform for chemical and biological sensors
Lavrik, N. V., Sepaniak, M. J., & Datskos, P. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1763252 · Cited by 1,117
Energy dissipation in tapping-mode atomic force microscopy
Cleveland, J. P., Anczykowski, B., Schmid, A. E., & Elings, V. B. (1998) · Applied Physics Letters · doi:10.1063/1.121434 · Cited by 881
Self-citationMajumdar, A. (1999) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.29.1.505 · Cited by 576
High-speed atomic force microscopy for nano-visualization of dynamic biomolecular processes
Ando, T., Uchihashi, T., & Fukuma, T. (2008) · Progress in Surface Science · doi:10.1016/j.progsurf.2008.09.001 · Cited by 558
Single virus particle mass detection using microresonators with nanoscale thickness
Gupta, A., Akin, D., & Bashir, R. (2004) · Applied Physics Letters · doi:10.1063/1.1667011 · Cited by 543
Comparison of calibration methods for atomic-force microscopy cantilevers
Burnham, N. A., Chen, X., Hodges, C. S., Matei, G. A., Thoreson, E. J., Roberts, C. J., Davies, M. C., & Tendler, S. J. B. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/1/301 · Cited by 458
Imaging and manipulation of biological structures with the AFM
Fotiadis, D. (2002) · Micron · doi:10.1016/s0968-4328(01)00026-9 · Cited by 390
AFM: a versatile tool in biophysics
Alessandrini, A., & Facci, P. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/6/r01 · Cited by 384
High-speed atomic force microscopy coming of age
Ando, T. (2012) · Nanotechnology · doi:10.1088/0957-4484/23/6/062001 · Cited by 355
Scanning Probe Evolution in Biology
Hörber, J. K. H., & Miles, M. J. (2003) · Science · doi:10.1126/science.1067410 · Cited by 353
Vasudevan, R. K., Balke, N., Maksymovych, P., Jesse, S., & Kalinin, S. V. (2017) · Applied Physics Reviews · doi:10.1063/1.4979015 · Cited by 344
Chon, J. W. M., Mulvaney, P., & Sader, J. E. (2000) · Journal of Applied Physics · doi:10.1063/1.372455 · Cited by 338
A mechanical microscope: High-speed atomic force microscopy
Humphris, A. D. L., Miles, M. J., & Hobbs, J. K. (2005) · Applied Physics Letters · doi:10.1063/1.1855407 · Cited by 308
Hydrodynamics of oscillating atomic force microscopy cantilevers in viscous fluids
Maali, A., Hurth, C., Boisgard, R., Jai, C., Cohen-Bouhacina, T., & Aimé, J.-P. (2005) · Journal of Applied Physics · doi:10.1063/1.1873060 · Cited by 270
Studying the Mechanics of Cellular Processes by Atomic Force Microscopy
Radmacher, M. (2007) · Methods in Cell Biology · doi:10.1016/s0091-679x(07)83015-9 · Cited by 263
Chemical and Biochemical Analysis Using Scanning Force Microscopy
Takano, H., Kenseth, J. R., Wong, S.-S., O'Brie, J. C., & Porter, M. D. (1999) · Chemical Reviews · doi:10.1021/cr9801317 · Cited by 259
Control of myocyte remodeling in vitro with engineered substrates
Geisse, N. A., Sheehy, S. P., & Parker, K. K. (2009) · In Vitro Cellular & Developmental Biology - Animal · doi:10.1007/s11626-009-9182-9 · Cited by 82
Metadata
- Authors
- Walters, D. A., Cleveland, J. P., Thomson, N. H., Hansma, P. K., Wendman, M. A., Gurley, G., & Elings, V.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1996-10-01
- Volume
- 67
- Issue
- 10
- Pages
- 3583-3590
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2040671013
- Cited by
- 494
- References
- 16
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.