The DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Cantilever transducers as a platform for chemical and biological sensors
Abstract
Since the late 1980s there have been spectacular developments in micromechanical or microelectro-mechanical (MEMS) systems which have enabled the exploration of transduction modes that involve mechanical energy and are based primarily on mechanical phenomena. As a result an innovative family of chemical and biological sensors has emerged. In this article, we discuss sensors with transducers in a form of cantilevers. While MEMS represents a diverse family of designs, devices with simple cantilever configurations are especially attractive as transducers for chemical and biological sensors. The review deals with four important aspects of cantilever transducers: (i) operation principles and models; (ii) microfabrication; (iii) figures of merit; and (iv) applications of cantilever sensors. We also provide a brief analysis of historical predecessors of the modern cantilever sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intermolecular and Surface Forces
(2011) · Intermolecular and Surface Forces · doi:10.1016/b978-0-12-391927-4.10024-6 · Cited by 16,923
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Timoshenko, S. P., & Woinowsky-Krieger, S. (1959) · UCLA Biblioteca de Ingenieria Civil · Cited by 12,112
The tension of metallic films deposited by electrolysis
Stoney, G. G. (1909) · Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character · doi:10.1098/rspa.1909.0021 · Cited by 4,872
Baughman, R. H., Cui, C., Zakhidov, A. A., Iqbal, Z., Barisci, J. N., Spinks, G. M., Wallace, G. G., Mazzoldi, A., De Rossi, D., Rinzler, A. G., et al. (1999) · Science · doi:10.1126/science.284.5418.1340 · Cited by 2,490
Frequency modulation detection using high-Q cantilevers for enhanced force microscope sensitivity
Albrecht, T. R., Grütter, P., Horne, D., & Rugar, D. (1991) · Journal of Applied Physics · doi:10.1063/1.347347 · Cited by 2,434
Analysis of Bi-Metal Thermostats
Timoshenko, S. (1925) · Journal of the Optical Society of America · doi:10.1364/josa.11.000233 · Cited by 2,426
Fundamentals of Microfabrication
(2016) · Micromechatronics · doi:10.1201/b15830-17 · Cited by 2,109
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Craighead, H. G. (2000) · Science · doi:10.1126/science.290.5496.1532 · Cited by 1,437
Atomic force microscope–force mapping and profiling on a sub 100-Å scale
Martin, Y., Williams, C. C., & Wickramasinghe, H. K. (1987) · Journal of Applied Physics · doi:10.1063/1.338807 · Cited by 1,428
Novel optical approach to atomic force microscopy
Meyer, G., & Amer, N. M. (1988) · Applied Physics Letters · doi:10.1063/1.100061 · Cited by 1,290
Thermoelastic damping in micro- and nanomechanical systems
Lifshitz, R., & Roukes, M. L. (2000) · Physical review. B, Condensed matter · doi:10.1103/physrevb.61.5600 · Cited by 1,231
Shuttleworth, R. (1950) · Proceedings of the Physical Society. Section A · doi:10.1088/0370-1298/63/5/302 · Cited by 1,115
Bioassay of prostate-specific antigen (PSA) using microcantilevers
Wu, G., Datar, R. H., Hansen, K. M., Thundat, T., Cote, R. J., & Majumdar, A. (2001) · Nature Biotechnology · doi:10.1038/nbt0901-856 · Cited by 1,013
Thermal noise in mechanical experiments
Saulson, P. R. (1990) · Physical Review D · doi:10.1103/physrevd.42.2437 · Cited by 852
Micromechanical cantilever-based biosensors
Raiteri, R., Grattarola, M., Butt, H.-J., & Skládal, P. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00856-5 · Cited by 734
(1996) · Handbook of Microscopy · doi:10.1002/9783527620524.ch13 · Cited by 726
Quality factors in micron- and submicron-thick cantilevers
Yasumura, K. Y., Stowe, T. D., Chow, E. M., Pfafman, T. E., Kenny, T. W., Stipe, B. C., & Rugar, D. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.825786 · Cited by 688
Improved fiber-optic interferometer for atomic force microscopy
Rugar, D., Mamin, H. J., & Guethner, P. (1989) · Applied Physics Letters · doi:10.1063/1.101987 · Cited by 629
Smart single-chip gas sensor microsystem
Hagleitner, C., Hierlemann, A., Lange, D., Kummer, A., Kerness, N., Brand, O., & Baltes, H. (2001) · Nature · doi:10.1038/35104535 · Cited by 619
Nanometre-scale displacement sensing using a single electron transistor
Knobel, R. G., & Cleland, A. N. (2003) · Nature · doi:10.1038/nature01773 · Cited by 599
The “Millipede”—More than thousand tips for future AFM storage
Vettiger, P., Despont, M., Drechsler, U., Durig, U., Haberle, W., Lutwyche, M. I., Rothuizen, H. E., Stutz, R., Widmer, R., & Binnig, G. K. (2000) · IBM Journal of Research and Development · doi:10.1147/rd.443.0323 · Cited by 566
Adsorption-induced surface stress and its effects on resonance frequency of microcantilevers
Chen, G. Y., Thundat, T., Wachter, E. A., & Warmack, R. J. (1995) · Journal of Applied Physics · doi:10.1063/1.359562 · Cited by 539
Fabrication of high frequency nanometer scale mechanical resonators from bulk Si crystals
Cleland, A. N., & Roukes, M. L. (1996) · Applied Physics Letters · doi:10.1063/1.117548 · Cited by 538
In Situ Interfacial Mass Detection with Piezoelectric Transducers
Ward, M. D., & Buttry, D. A. (1990) · Science · doi:10.1126/science.249.4972.1000 · Cited by 525
A nanometre-scale mechanical electrometer
Cleland, A. N., & Roukes, M. L. (1998) · Nature · doi:10.1038/32373 · Cited by 512
Short cantilevers for atomic force microscopy
Walters, D. A., Cleveland, J. P., Thomson, N. H., Hansma, P. K., Wendman, M. A., Gurley, G., & Elings, V. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147177 · Cited by 494
KUHN, W., HARGITAY, B., KATCHALSKY, A., & EISENBERG, H. (1950) · Nature · doi:10.1038/165514a0 · Cited by 490
Noise processes in nanomechanical resonators
Cleland, A. N., & Roukes, M. L. (2002) · Journal of Applied Physics · doi:10.1063/1.1499745 · Cited by 461
The intrinsic stress of polycrystalline and epitaxial thin metal films
Koch, R. (1994) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/6/45/005 · Cited by 451
Single cell detection with micromechanical oscillators
Ilic, B., Czaplewski, D., Zalalutdinov, M., Craighead, H. G., Neuzil, P., Campagnolo, C., & Batt, C. (2001) · Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena · doi:10.1116/1.1421572 · Cited by 443
Sub-attonewton force detection at millikelvin temperatures
Mamin, H. J., & Rugar, D. (2001) · Applied Physics Letters · doi:10.1063/1.1418256 · Cited by 439
Detection of mercury vapor using resonating microcantilevers
Thundat, T., Wachter, E. A., Sharp, S. L., & Warmack, R. J. (1995) · Applied Physics Letters · doi:10.1063/1.113896 · Cited by 436
Thermal and ambient-induced deflections of scanning force microscope cantilevers
Thundat, T., Warmack, R. J., Chen, G. Y., & Allison, D. P. (1994) · Applied Physics Letters · doi:10.1063/1.111407 · Cited by 419
Origin of nanomechanical cantilever motion generated from biomolecular interactions
Wu, G., Ji, H., Hansen, K., Thundat, T., Datar, R., Cote, R., Hagan, M. F., Chakraborty, A. K., & Majumdar, A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.4.1560 · Cited by 415
Mechanical detection of magnetic resonance
Rugar, D., Yannoni, C. S., & Sidles, J. A. (1992) · Nature · doi:10.1038/360563a0 · Cited by 395
Modeling and optimal design of piezoelectric cantilever microactuators
DeVoe, D. L., & Pisano, A. P. (1997) · Journal of Microelectromechanical Systems · doi:10.1109/84.623116 · Cited by 352
Cantilever-Based Optical Deflection Assay for Discrimination of DNA Single-Nucleotide Mismatches
Hansen, K. M., Ji, H.-F., Wu, G., Datar, R., Cote, R., Majumdar, A., & Thundat, T. (2001) · Analytical Chemistry · doi:10.1021/ac0012748 · Cited by 337
Photothermal spectroscopy with femtojoule sensitivity using a micromechanical device
Barnes, J. R., Stephenson, R. J., Welland, M. E., Gerber, C., & Gimzewski, J. K. (1994) · Nature · doi:10.1038/372079a0 · Cited by 327
Femtogram mass detection using photothermally actuated nanomechanical resonators
Lavrik, N. V., & Datskos, P. G. (2003) · Applied Physics Letters · doi:10.1063/1.1569050 · Cited by 308
Self-citationMeasuring surface forces in aqueous electrolyte solution with the atomic force microscope
Butt, H.-J., Jaschke, M., & Ducker, W. (1995) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(95)01800-t · Cited by 273
Environmental sensors based on micromachined cantilevers with integrated read-out
Boisen, A., Thaysen, J., Jensenius, H., & Hansen, O. P. (2000) · Ultramicroscopy · doi:10.1016/s0304-3991(99)00148-5 · Cited by 269
Grate, J. W., Snow, A., Ballantine, D. S., Wohltjen, H., Abraham, M. H., McGill, R. A., & Sasson, P. (1988) · Analytical Chemistry · doi:10.1021/ac00160a010 · Cited by 246
Microcantilever-based biosensors
Moulin, A. M., O'Shea, S. J., & Welland, M. E. (2000) · Ultramicroscopy · doi:10.1016/s0304-3991(99)00145-x · Cited by 232
A Sensitive Method to Measure Changes in the Surface Stress of Solids
Butt, H.-J. (1996) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1996.0297 · Cited by 218
Optomechanical uncooled infrared imaging system: design, microfabrication, and performance
Zhao, Y., Mao, M., Horowitz, R., Majumdar, A., Varesi, J., Norton, P., & Kitching, J. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/84.993448 · Cited by 214
Sensitive detection of plastic explosives with self-assembled monolayer-coated microcantilevers
Pinnaduwage, L. A., Boiadjiev, V., Hawk, J. E., & Thundat, T. (2003) · Applied Physics Letters · doi:10.1063/1.1602156 · Cited by 200
STEINBERG, I. Z., OPLATKA, A., & KATCHALSKY, A. (1966) · Nature · doi:10.1038/210568a0 · Cited by 192
A microsensor for trinitrotoluene vapour
Pinnaduwage, L. A., Gehl, A., Hedden, D. L., Muralidharan, G., Thundat, T., Lareau, R. T., Sulchek, T., Manning, L., Rogers, B., Jones, M., et al. (2003) · Nature · doi:10.1038/425474a · Cited by 189
Direct measurement of crystal surface stress
Martinez, R., Augustyniak, W., & Golovchenko, J. (1990) · Physical Review Letters · doi:10.1103/physrevlett.64.1035 · Cited by 164
Measuring Surface-Induced Conformational Changes in Proteins
Moulin, A. M., O’Shea, S. J., BADLEY, R. A., Doyle, P., & Welland, M. E. (1999) · Langmuir · doi:10.1021/la990416u · Cited by 147
Biosensor based on force microscope technology
Baselt, D. R., Lee, G. U., & Colton, R. J. (1996) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.588714 · Cited by 142
The future of MEMS in telecommunications networks
Walker, J. A. (2000) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/10/3/201 · Cited by 111
Micromechanical thermogravimetry
Berger, R., Lang, H. P., Gerber, C., Gimzewski, J. K., Fabian, J.-H., Scandella, L., Meyer, E., & Güntherodt, H. ‐. (1998) · Chemical Physics Letters · doi:10.1016/s0009-2614(98)00817-3 · Cited by 110
Gold Nano-Structures for Transduction of Biomolecular Interactions into Micrometer Scale Movements
Lavrik, N. V., Tipple, C. A., Sepaniak, M. J., & Datskos, P. G. (2001) · Biomedical Microdevices · doi:10.1023/a:1011473203133 · Cited by 107
Self-citationDetection of Hg2+ Using Microcantilever Sensors
Xu, X., Thundat, T. G., Brown, G. M., & Ji, H. (2002) · Analytical Chemistry · doi:10.1021/ac0255781 · Cited by 100
Mechanisms of noise sources in microelectromechanical systems
Djuric, Z. G. (2000) · Microelectronics Reliability · doi:10.1016/s0026-2714(00)00004-4 · Cited by 96
Detection of pH variation using modified microcantilever sensors
Ji, H., Hansen, K. M., Hu, Z., & Thundat, T. G. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(00)00678-x · Cited by 92
High-sensitivity optical measurement of mechanical Brownian motion
Hadjar, Y., Cohadon, P.-F., Aminoff, C. G., Pinard, M., & Heidmann, A. (1999) · Europhysics Letters (EPL) · doi:10.1209/epl/i1999-00422-6 · Cited by 86
Self-excited piezoelectric cantilever oscillators
Lee, S. S., & White, R. M. (1996) · Sensors and Actuators A Physical · doi:10.1016/0924-4247(96)80123-3 · Cited by 66
Janata, J. (1990) · Analytical Chemistry · doi:10.1021/ac00211a003 · Cited by 61
Datskos, P. G., Rajic, S., Sepaniak, M. J., Lavrik, N. V., Tipple, C. A., Senesac, L. R., & Datskou, I. (2001) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.1387082 · Cited by 60
Self-citationHigh-sensitivity optical measurement of mechanical Brownian motion
Hadjar, Y., Cohadon, P.-F., Aminoff, C. G., Pinard, M., & Heidmann, A. (1999) · HAL (Le Centre pour la Communication Scientifique Directe) · Cited by 57
Pereira, R. D. S. (2001) · Biochemical Pharmacology · doi:10.1016/s0006-2952(01)00746-8 · Cited by 56
Photomechanical chemical microsensors
Datskos, P. G., Sepaniak, M. J., Tipple, C. A., & Lavrik, N. V. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00647-5 · Cited by 55
Self-citationFundamental Noise Limits for Miniature Acoustic and Vibration Sensors
Gabrielson, T. B. (1995) · Journal of vibration and acoustics · doi:10.1115/1.2874471 · Cited by 52
Detection of Explosive Compounds with the Use of Microcantilevers with Nanoporous Coatings
Datskos, P. G., Lavrik, N. V., & Sepaniak, M. J. (2003) · Sensor Letters · doi:10.1166/sl.2003.016 · Cited by 46
Self-citationMEMS technology in analytical chemistry
Deisingh, A. K. (2002) · The Analyst · doi:10.1039/b211229a · Cited by 14
Cited by
Recent Progress in Materials and Devices toward Printable and Flexible Sensors
Rim, Y. S., Bae, S., Chen, H., De Marco, N., & Yang, Y. (2016) · Advanced Materials · doi:10.1002/adma.201505118 · Cited by 771
Micro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
Cantilever-like micromechanical sensors
Boisen, A., Dohn, S., Keller, S. S., Schmid, S., & Tenje, M. (2011) · Reports on Progress in Physics · doi:10.1088/0034-4885/74/3/036101 · Cited by 566
Probing Liquid/Solid Interfaces at the Molecular Level
Zaera, F. (2012) · Chemical Reviews · doi:10.1021/cr2002068 · Cited by 458
Freestanding Nanostructures via Layer‐by‐Layer Assembly
Jiang, C., & Tsukruk, V. V. (2006) · Advanced Materials · doi:10.1002/adma.200502444 · Cited by 402
Metadata
- Authors
- Lavrik, N. V., Sepaniak, M. J., & Datskos, P. G.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2004-07-01
- Volume
- 75
- Issue
- 7
- Pages
- 2229-2253
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2061543408
- Cited by
- 1,117
- References
- 70
- FWCI
- 54.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.