The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Spring constant calibration of atomic force microscope cantilevers of arbitrary shape
Open accessAbstract
The spring constant of an atomic force microscope cantilever is often needed for quantitative measurements. The calibration method of Sader et al. [Rev. Sci. Instrum. 70, 3967 (1999)]10.1063/1.1150021 for a rectangular cantilever requires measurement of the resonant frequency and quality factor in fluid (typically air), and knowledge of its plan view dimensions. This intrinsically uses the hydrodynamic function for a cantilever of rectangular plan view geometry. Here, we present hydrodynamic functions for a series of irregular and non-rectangular atomic force microscope cantilevers that are commonly used in practice. Cantilever geometries of arrow shape, small aspect ratio rectangular, quasi-rectangular, irregular rectangular, non-ideal trapezoidal cross sections, and V-shape are all studied. This enables the spring constants of all these cantilevers to be accurately and routinely determined through measurement of their resonant frequency and quality factor in fluid (such as air). An approximate formulation of the hydrodynamic function for microcantilevers of arbitrary geometry is also proposed. Implementation of the method and its performance in the presence of uncertainties and non-idealities is discussed, together with conversion factors for the static and dynamic spring constants of these cantilevers. These results are expected to be of particular value to the design and application of micro- and nanomechanical systems in general.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Advances in atomic force microscopy
Giessibl, F. J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.949 · Cited by 2,278
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Self-citationDynamic atomic force microscopy methods
García, R. (2002) · Surface Science Reports · doi:10.1016/s0167-5729(02)00077-8 · Cited by 2,076
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Sader, J. E. (1998) · Journal of Applied Physics · doi:10.1063/1.368002 · Cited by 1,410
Self-citationMethod for the calibration of atomic force microscope cantilevers
Sader, J. E., Larson, I., Mulvaney, P., & White, L. R. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145439 · Cited by 1,000
Self-citationNormal and torsional spring constants of atomic force microscope cantilevers
Green, C. P., Lioe, H., Cleveland, J. P., Proksch, R., Mulvaney, P., & Sader, J. E. (2004) · Review of Scientific Instruments · doi:10.1063/1.1753100 · Cited by 551
Self-citationLévy, R., & Maaloum, M. (2002) · Nanotechnology · doi:10.1088/0957-4484/13/1/307 · Cited by 366
Roark's formulas for stress and strain; seventh edition
Budynas, R. G., & Sadegh, A. M. (1989) · McGraw-Hill Education eBooks · Cited by 338
Chon, J. W. M., Mulvaney, P., & Sader, J. E. (2000) · Journal of Applied Physics · doi:10.1063/1.372455 · Cited by 338
Self-citationLateral, normal, and longitudinal spring constants of atomic force microscopy cantilevers
Neumeister, J. M., & Ducker, W. A. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144646 · Cited by 334
Studies of vibrating atomic force microscope cantilevers in liquid
Schäffer, T. E., Cleveland, J. P., Ohnesorge, F., Walters, D. A., & Hansma, P. K. (1996) · Journal of Applied Physics · doi:10.1063/1.363308 · Cited by 311
A method for determining the spring constant of cantilevers for atomic force microscopy
Torii, A., Sasaki, M., Hane, K., & Okuma, S. (1996) · Measurement Science and Technology · doi:10.1088/0957-0233/7/2/010 · Cited by 282
Theoretical analysis of the static deflection of plates for atomic force microscope applications
Sader, J. E., & White, L. (1993) · Journal of Applied Physics · doi:10.1063/1.354137 · Cited by 268
Self-citationParallel beam approximation for V-shaped atomic force microscope cantilevers
Sader, J. E. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145292 · Cited by 260
Self-citationNoninvasive determination of optical lever sensitivity in atomic force microscopy
Higgins, M. J., Proksch, R., Sader, J. E., Polcik, M., Mc Endoo, S., Cleveland, J. P., & Jarvis, S. P. (2006) · Review of Scientific Instruments · doi:10.1063/1.2162455 · Cited by 239
Self-citationDetermination of the spring constants of probes for force microscopy/spectroscopy
Gibson, C. T., Watson, G. S., & Myhra, S. (1996) · Nanotechnology · doi:10.1088/0957-4484/7/3/014 · Cited by 237
Finite optical spot size and position corrections in thermal spring constant calibration
Proksch, R., Schäffer, T. E., Cleveland, J. P., Callahan, R. C., & Viani, M. B. (2004) · Nanotechnology · doi:10.1088/0957-4484/15/9/039 · Cited by 237
Scan speed limit in atomic force microscopy
BUTT, H. ‐., SIEDLE, P., SEIFERT, K., FENDLER, K., SEEGER, T., BAMBERG, E., WEISENHORN, A. L., GOLDIE, K., & ENGEL, A. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03280.x · Cited by 233
Experimental Determination of Spring Constants in Atomic Force Microscopy
Senden, T., & Ducker, W. (1994) · Langmuir · doi:10.1021/la00016a600 · Cited by 205
Cook, S. M., Lang, K. M., Chynoweth, K. M., Wigton, M., Simmonds, R. W., & Schäffer, T. E. (2006) · Nanotechnology · doi:10.1088/0957-4484/17/9/010 · Cited by 186
Characterization of application-specific probes for SPMs:
Tortonese, M., & Kirk, M. (1997) · SPIE Proceedings · doi:10.1117/12.271229 · Cited by 181
Clifford, C. A., & Seah, M. P. (2005) · Nanotechnology · doi:10.1088/0957-4484/16/9/044 · Cited by 181
Cantilever spring constant calibration using laser Doppler vibrometry
Ohler, B. (2007) · Review of Scientific Instruments · doi:10.1063/1.2743272 · Cited by 156
Interlaboratory round robin on cantilever calibration for AFM force spectroscopy
Riet, J. T., Katan, A. J., Rankl, C., Ståhl, S., van Buul, A. M., Phang, I. Y., Gómez-Casado, A., Schön, P. M., Gerritsen, J. W., Cambi, A., et al. (2011) · Ultramicroscopy · doi:10.1016/j.ultramic.2011.09.012 · Cited by 132
Pettersson, T., Nordgren, N., Rutland, M. W., & Feiler, A. A. (2007) · Review of Scientific Instruments · doi:10.1063/1.2779215 · Cited by 114
Small amplitude oscillations of a thin beam immersed in a viscous fluid near a solid surface
Green, C. P., & Sader, J. E. (2005) · Physics of Fluids · doi:10.1063/1.1995467 · Cited by 106
Self-citationNormal and Lateral Force Calibration Techniques for AFM Cantilevers
Palacio, M. L. B., & Bhushan, B. (2010) · Critical reviews in solid state and materials sciences/CRC critical reviews in solid state and materials sciences · doi:10.1080/10408430903546691 · Cited by 99
Sader, J. E., Pacifico, J., Green, C. P., & Mulvaney, P. A. (2005) · Journal of Applied Physics · doi:10.1063/1.1935133 · Cited by 81
Self-citationOscillation of cylinders of rectangular cross section immersed in fluid
Brumley, D. R., Willcox, M., & Sader, J. E. (2010) · Physics of Fluids · doi:10.1063/1.3397926 · Cited by 74
Self-citationCalibration of higher eigenmode spring constants of atomic force microscope cantilevers
Lozano, J. R., Kiracofe, D. R., Melcher, J. T., Garcia, R. A., & Raman, A. (2010) · Nanotechnology · doi:10.1088/0957-4484/21/46/465502 · Cited by 66
Stiernstedt, J., Rutland, M. W., & Attard, P. (2005) · Review of Scientific Instruments · doi:10.1063/1.2006407 · Cited by 55
Energy dissipation measurements in frequency-modulated scanning probe microscopy
Proksch, R. B., & Kalinin, S. V. (2010) · Nanotechnology · doi:10.1088/0957-4484/21/45/455705 · Cited by 34
Precise determination of force microscopy cantilever stiffness from dimensions and eigenfrequencies
Lübbe, J., Doering, L., & Reichling, M. (2012) · Measurement Science and Technology · doi:10.1088/0957-0233/23/4/045401 · Cited by 27
High-resolution cantilever biosensor resonating at air–liquid in a microchannel
Park, J., Nishida, S., Lambert, P., Kawakatsu, H., & Fujita, H. (2011) · Lab on a Chip · doi:10.1039/c1lc20608g · Cited by 24
Sader, J. E., Sanelli, J. A., Hughes, B. D., Monty, J., & Bieske, E. J. (2011) · Review of Scientific Instruments · doi:10.1063/1.3632122 · Cited by 18
Self-citationChung, K., Scholz, S., Shaw, G. A., Kramar, J. A., & Pratt, J. R. (2008) · Review of Scientific Instruments · doi:10.1063/1.2987695 · Cited by 17
Cited by
Quantum-size-tuned heterostructures enable efficient and stable inverted perovskite solar cells
Chen, H., Teale, S., Chen, B., Hou, Y., Grater, L., Zhu, T., Bertens, K., Park, S. M., Atapattu, H. R., Gao, Y., et al. (2022) · Nature Photonics · doi:10.1038/s41566-022-00985-1 · Cited by 588
Accurate thickness measurement of graphene
Shearer, C. J., Slattery, A. D., Stapleton, A. J., Shapter, J. G., & Gibson, C. T. (2016) · Nanotechnology · doi:10.1088/0957-4484/27/12/125704 · Cited by 496
Schillers, H., Rianna, C., Schäpe, J., Luque, T., Doschke, H., Wälte, M., Uriarte, J. J., Campillo, N., Michanetzis, G. P. A., Bobrowska, J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-05383-0 · Cited by 268
Mullin, N., & Hobbs, J. K. (2014) · Review of Scientific Instruments · doi:10.1063/1.4901221 · Cited by 58
Metadata
- Authors
- Sader, J. E., Sanelli, J. A., Adamson, B. D., Monty, J. P., Wei, X., Crawford, S. A., Friend, J. R., Marusic, I., Mulvaney, P., & Bieske, E. J.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2012-10-01
- Volume
- 83
- Issue
- 10
- Pages
- 103705-103705
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2069430847
- Cited by
- 283
- References
- 40
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.