The absolute frequency of the87Sr optical clock transition
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The absolute frequency of the 1S0-3P0 clock transition of 87Sr has been measured to be 429 228 004 229 873.65 (37) Hz using lattice-confined atoms, where the fractional uncertainty of 8.6x10-16 represents one of the most accurate measurements of an atomic transition frequency to date. After a detailed study of systematic effects, which reduced the total systematic uncertainty of the Sr lattice clock to 1.5x10-16, the clock frequency is measured against a hydrogen maser which is simultaneously calibrated to the US primary frequency standard, the NIST Cs fountain clock, NIST-F1. The comparison is made possible using a femtosecond laser based optical frequency comb to phase coherently connect the optical and microwave spectral regions and by a 3.5 km fiber transfer scheme to compare the remotely located clock signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum dynamics of single trapped ions
Leibfried, D., Blatt, R., Monroe, C., & Wineland, D. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.281 · Cited by 2,739
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Self-citationTakamoto, M., Hong, F.-L., Higashi, R., & Katori, H. (2005) · Nature · doi:10.1038/nature03541 · Cited by 853
New Limits on the Drift of Fundamental Constants from Laboratory Measurements
Fischer, M., Kolachevsky, N., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., Abgrall, M., Grünert, J., Maksimovic, I., Bize, S., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.230802 · Cited by 431
Remote transfer of ultrastable frequency references via fiber networks
Foreman, S. M., Holman, K. W., Hudson, D. D., Jones, D. J., & Ye, J. (2007) · Review of Scientific Instruments · doi:10.1063/1.2437069 · Cited by 403
Self-citationNIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Self-citationSantarelli, G., Audoin, C., Makdissi, A., Laurent, P., Dick, G. J., & Clairon, A. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.710548 · Cited by 314
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
Porsev, S. G., & Derevianko, A. (2006) · Physical Review A · doi:10.1103/physreva.74.020502 · Cited by 279
Fortier, T. M., Ashby, N., Bergquist, J. C., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.070801 · Cited by 226
Self-citation
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Self-citationFrequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Theory and applications of atomic and ionic polarizabilities
Mitroy, J., Safronova, M. S., & Clark, C. W. (2010) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/43/20/202001 · Cited by 489
Frequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
Self-citationJILA SrI optical lattice clock with uncertainty of 2.0 × 10 − 18
Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J. (2019) · Metrologia · doi:10.1088/1681-7575/ab4089 · Cited by 324
“A history of evaluations of the Sr second order Zeeman coefficient completed by the PTB [8], SYRTE [29], and JILA [1, 2, 30] Sr OLCs.”
MethodInfluentialSelf-citationThe CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Optical lattice clocks and quantum metrology
Katori, H. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.45 · Cited by 281
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“Such measurements are typically limited by the accuracy of the Cs fountain clocks to a few parts in 10 16 (Oskay et al 2006, Campbell et links as discussed in section 6.2 is achieved by stabilizing the output of a laser operating near the target wavelength with one of the stabilized comb teeth.”
InfluentialColloquium: Physics of optical lattice clocks
Derevianko, A., & Katori, H. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.331 · Cited by 253
Comparison of Two Independent Sr Optical Clocks with1×10−17Stability at103 s
Nicholson, T. L., Martin, M. J., Williams, J. R., Bloom, B. J., Bishof, M., Swallows, M. D., Campbell, S. L., & Ye, J. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.230801 · Cited by 205
Self-citationA strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Suppression of Collisional Shifts in a Strongly Interacting Lattice Clock
Swallows, M. D., Bishof, M., Lin, Y., Blatt, S., Martin, M. J., Rey, A. M., & Ye, J. (2011) · Science · doi:10.1126/science.1196442 · Cited by 181
Self-citationTowards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
Rabi spectroscopy and excitation inhomogeneity in a one-dimensional optical lattice clock
Blatt, S., Thomsen, J. W., Campbell, G. K., Ludlow, A. D., Swallows, M. D., Martin, M. J., Boyd, M. M., & Ye, J. (2009) · Physical Review A · doi:10.1103/physreva.80.052703 · Cited by 167
Self-citationHigh Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.263004 · Cited by 154
Differential clock comparisons with a multiplexed optical lattice clock
Zheng, X., Dolde, J., Lochab, V., Merriman, B. N., Li, H., & Kolkowitz, S. (2022) · Nature · doi:10.1038/s41586-021-04344-y · Cited by 150
Realization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
The87Sr optical frequency standard at PTB
Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., et al. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/022 · Cited by 129
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102
“eported in [8]. Right: the points for Cs of the left gure with the smallest statistical uncertainty are compared with similar measurement worldwide since 2006 (green : LNE-SYRTE [24, 8], red : JILA [25, 26], light blue : Tokyo University [27], orange : PTB [28, 10, 6], pink : NICT [27, 29, 30, 5], purple : NMIJ [31, 3…”
BackgroundLong term measurement of theSr87clock frequency at the limit of primary Cs clocks
Schwarz, R., Dörscher, S., Al-Masoudi, A., Benkler, E., Legero, T., Sterr, U., Weyers, S., Rahm, J., Lipphardt, B., & Lisdat, C. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033242 · Cited by 64
Intermittent optical frequency measurements to reduce the dead time uncertainty of frequency link
Hachisu, H., & Ido, T. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.112401 · Cited by 48
International timescales with optical clocks (ITOC)
Margolis, H. S., Godun, R. M., Gill, P., Johnson, L. A. M., Shemar, S. L., Whibberley, P. B., Calonico, D., Levi, F., Lorini, L., Pizzocaro, M., et al. (2013) · 2013 Joint European Frequency and Time Forum & International Frequency Control Symposium (EFTF/IFC) · doi:10.1109/eftf-ifc.2013.6702183 · Cited by 15
Metadata
- Authors
- Campbell, G. K., Ludlow, A. D., Blatt, S., Thomsen, J. W., Martin, M. J., de Miranda, M. H. G., Zelevinsky, T., Boyd, M. M., Ye, J., Diddams, S. A., Heavner, T. P., Parker, T. E., & Jefferts, S. R.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2008-09-24
- Volume
- 45
- Issue
- 5
- Pages
- 539-548
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2121832766
- Cited by
- 151
- References
- 14
- FWCI
- 9.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.